GRE PSR-200U Owner's Manual
|
GRE PSR-200U, 8 PREPARATION POWER SOURCES USING AC POWER You can power the scanner using a supplied AC adaptor. Cautions: ! You must use a supplied AC adaptor. • Always connect the AC adaptor to the scanner before you connect it to AC power. When you finish, disconnect the adaptor from AC power before you disconnect it from the scanner. • The correct orientation for the enclosed power adaptor is in a vertical or floor-mount position. • Plug the adaptor into an easily accessible power outlet located near the equipment. To pow
GRE PSR-200U, 34 Cloning the Programmed Data You can transfer the programmed data to and from a PSR-200U scanner using an optional connecting cable with 3.5mm stereo phone plugs on both ends (not supplied). 1. Turn on both scanner. 2. Connect the connecting cable to each scanner’s PC/IF jack. CLOnE and UP to SEnd appears. 3. Press 5 on the host scanner. 4. SEndInG appears at the host scanner. To exit clone mode after the data transfer is complete, remove the cable. No ConnEct appears if you try to connect to another model scanner. The PSR-200U does not clone with other scanner models. INITIALIZING
GRE PSR-200U, 6 THE FCC WANT YOU TO KNOW This equipment has been tested and found to comply with the limits for a scanning receiver, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particul
GRE PSR-200U, 26 LISTENING TO THE WEATHER BAND Your scanner incorporates weather alert as one of its features and is an extremely sensitive high quality receiver on the weather frequencies. However, the included telescopic antenna is optimized for general purpose scanning. If you use this scanner as your only means for receiving weather alerts, please check to be sure you are receiving a clear signal on the telescopic antenna or switch to an external antenna that gives you clear reception of a local NOAA weather broadcast. The FCC (Federal Communications Commi
GRE PSR-200U, 22 2. If desired, you can change the start frequency. To change the start frequency, enter frequency with numeral keys, then press ENT. 3. Press PSE/CLEAR to start tune. -t- appears on the display. 4. To change the tuning direction, press 5 or 6 . The scanner displays 5 or 6 and start tune. Note: To pause the tune, press PSE. To resume tune, press PSE again. 5. To tune for another active frequency, press 5 or 6 . Copying a Frequency into a Vacant Channel in a Specified Bank 1. To store the displayed frequency in the desired bank’s l
GRE PSR-200U, 15 WEAthEr — Appears about 2 seconds when you select weather band. Lo VHF — Appears when you turn on the low VHF sub-bank while fire/police bank searching. Hi VHF — Appears when you turn on the high VHF sub-bank while fire/ police bank searching. UHF — Appears when you turn on the UHF sub-bank while fire/police bank searching. 10 M — Appears when you turn on the 10m sub-bank 1 while HAM bank searching. 6 M — Appears when you turn on the 6m sub-bank 2 while HAM bank searching. 2 M — Appears when you turn on the 2m sub-bank 3
GRE PSR-200U, 3 Special Features ..........................................................................................................29 Using CTCSS and DCS ...............................................................................................29 Searching CTCSS/DCS Code .....................................................................................29 Programming CTCSS/DCS Code Search Setting into Channel Memory...................29 Programming CTCSS/DCS Code into Channel Memory....................
GRE PSR-200U, 19 OPERATION UNDERSTANDING 3 MODES Your PSR-200U has three kinds of modes, and changes the mode by pressing an orange key. • Scan/Manual mode • FM Radio mode • Service Search mode If you press SCAN (Orange) key, your PSR-200U scanner enters SCAN/ MANUAL mode. The SCAN/MANUAL mode is a mode to which the programmed channel memory is scanned. Or you can manually tuning the channel memory. If you press FM RADIO (Orange) key, the scanner enters FM RADIO mode. FM RADIO mode is a mode to receive FM broadcast. You can use tune operation or manually FM-
GRE PSR-200U, 31 • If the scanner is searching, or tuning, press DELAY/•. DLY appears and the scanner automatically adds a 2-second delay to every transmission it stops on in that band. To turn off the 2-second delay in a channel or for all frequency, press DELAY/• while the scanner is monitoring that channel or frequency. DLY disappears. LOCKING OUT CHANNELS OR FREQUENCIES You can increase the effective scanning or search speed by locking out individual channels or frequencies that have a con
GRE PSR-200U, 1 PSR-200U 200-Channel plus 20 FM Channel VHF/Air/UHF Desktop Scanner Please read this user's guide before installing, setting up and using your new product. Owner’s Manual PSR200U-OM.indd 1 2010/02/22 16:24:41
36 FAQs (Frequently Asked Questions) The scanner is not working at all. What’s wrong? • The AC or DC adaptor might not be connected. Be sure the adaptor’s barrel plug is fully inserted into the DC 9V jack. The center tip of the adaptor’s barrel plug must be set to positive. The scanner does not receive any stations or reception is poor. Wh
GRE PSR-200U, 40 Limited Warranty General GRE America, Inc. warranty all parts of each new product to be of sound design, good material and workmanship, and will repair or exchange any parts proven to be defective under normal use at no charge for a period of 12 months from the date of sale to the end user. GRE America will correct defects. There will be no charge for labor for a period of 12 months from the date of original sale, except as provided below. Overtime premiums and/or expedited handling and shipping costs must be paid by the owner. An enclosed Warranty Card is included with each unit of purchase. We request the Warranty card be filled and return back t
28 Skywarn Many areas of the country have amateur radio repeaters that have been designated as “Skywarn” repeaters. During times of severe weather, these repeaters are used to relay reports of severe weather directly to meteorologists at a local National Weather Service (NWS) forecast office. Using the Skywarn feature in your scanne
GRE PSR-200U, 5 Supplied Telescoping Antenna — provides good reception of strong local signals. External Antenna Connector — lets you connect an external antenna (not supplied) with a BNC connector to the scanner for improved reception of distant/weaker signals. Your PSR-200U scanner can receive these bands: Frequency Range Types of Transmissions 29–54 MHz 10-Meter Ham Band, VHF Lo, 6-Meter Ham Band 87.3–107.9 MHz FM broadcast 108–136.99166 MHz Aircraft 137–174 MHz Military Land Mobile, 2-Meter Ham Band, VHF Hi 380–512 MHz UHF Aircraft, Federal Government, 70-cm Ham Band, UHF Standard Band, UHF “T” Band Note: See “
GRE PSR-200U, 2 CONTENTS Features .........................................................................................................................4 Preparation .....................................................................................................................8 Power Sources ...............................................................................................................8 Using AC Power ........................................................................................
13 A LOOK AT THE DISPLAY The display has indicators that show the scanner’s current operating status. This quick look at the display will help you understand how your scanner operates. — Appears when you hear the skywarn channel. FD/PD — Indicates that the scanner is active for fire/police bank. BANK — Appears with numbers (1–10) to indicate the sc
GRE PSR-200U, 27 SAME Standby Mode The National Weather Service precedes each weather alert with a digitally encoded SAME (Specific Area Message Encoding) signal, then a 1050 Hz tone. The SAME signal includes a FIPS (Federal Information Processing Standard) area code, and an event code that corresponds with the type of alert being sent. You can configure your scanner to operate in SAME Standby mode, where it monitors a selected weather radio station for SA
GRE PSR-200U, 18 Fire/Police Group Frequency Range (MHz) Step (kHz) 1 33.420-33.980 20 37.020-37.420 20 39.020-39.980 20 42.020-42.940 20 44.620-45.860 40 45.880 - 45.900-46.060 40 46.080-46.500 20 2 153.770-154.130 60 154.145-154.445 15 154.650-154.950 15 155.010-155.370 60 155.415-155.700 15 155.730-156.210 60 158.730-159.210 60 166.250 - 170.150 - 3 453.0375-453.9625 12.5 458.0375-458.9625 12.5 460.0125-460.6375 12.5 465.0125-465.6375 12.5 Air Group Frequency Range (MHz) Step (kHz) 1 108.000-118.000 8.33 2 118.00833-136.99166 8.33 Amateur Radio Group Frequency R
GRE PSR-200U, 35 Birdie Frequencies Every scanner has birdie frequencies. Birdies are signals created inside the scanner’s receiver. These operating frequencies might interfere with transmissions on the same frequencies. If you program one of these frequencies, you hear only noise on that frequency. If the interference is not severe, you might be able to turn SQUELCH clockwise to cut out the birdie. To find the birdies in your individual scanner, begin by disconnecting the antenna and moving it away from the scanner. M
GRE PSR-200U, 14 S — Appears with 8-digit bar that shows receiving signal strength. PGM — Appears when you program frequencies into the scanner’s channels. DLY — Appears when you program a 2-second delay. ALL CH L-out — Appears when you lock out the all marine channels. -b- — Appears during service search (Fire/Police, Aircraft and Ham band) b X Ch-FULL — Appears when you try to enter a frequency during a search when all displayed bank’s channels are full. b X StorE — Appears when you
Minolta MS 6000 Scanner Operator's manual
MS 6000 |
Hand Held Products 5700 Scanner Operation & user’s manual
5700 |
Kodak I1210 - Document Scanner Scanner Operation & user’s manual
I1210 - Document Scanner |
Ricoh 480W Scanner Network manual
480W |
GRE PSR-100 Scanner Owner's manual
PSR-100 |
GRE PSR-282 Scanner Owner's manual
PSR-282 |
Epson Stylus CX9475 Scanner Supplementary manual
Stylus CX9475 |
Uniden BC346XT Scanner Owner's manual
BC346XT |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Honeywell | HCM-530 Series | Important safety instructions manual | honeywell/hcm-530-series-971.pdf | 29 Dec 2022 | 6 | 1.05 Mb |
2 | Valcom | VIP-432-DF | Operation & user’s manual | valcom/vip-432-df-VI8.pdf | 06 Oct 2022 | 3 | 0.11 Mb |
3 | HP | D5300 | Basic manual | hp/d5300-VYB.pdf | 22 Nov 2022 | 29 | |
4 | Panasonic | CS-A120K Series | Operating instructions manual | panasonic/cs-a120k-series-2H5.pdf | 18 Jun 2023 | 24 | 1.12 Mb |
5 | Scientific Atlanta | DPX2203 | Operation & user’s manual | scientific-atlanta/dpx2203-26S.pdf | 26 Jul 2022 | 52 | 7.08 Mb |
6 | Delta Electronics | 92 x 92 x 15 MM Series | Specification sheet | delta-electronics/92-x-92-x-15-mm-series-4V2.pdf | 03 Oct 2022 | 1 | 0.27 Mb |
RIOTEC
1 Programming Quick Guide -iLS6300FBU/iLS6300FB Connecting the Scanner Be sure that PC is turned OFF, before Connect scanner cable to the PC USB port on the PC as below described, Ensure that all connections are ready, and turn on your PC. 1. Please switch ON and charge scanner for 4~5 hours at first time before use. Scanner switch shown on Fig. 2. 2. …
iLS6300FBU(4 pages) |
Kodak
If you want high-quality and ecient scanning right by your side, you’ve come to the right place. Packed with professional-grade scanning features, this entry-level scanner bundle is the perfect solution for small oces or departments that need convenient, high-quality scanning solutions. And the best part? Sidekick Scanners can boost productivity and …
Sidekick 1400U(2 pages) |
Ricoh
FAX Option Type C4500Operating InstructionsFacsimile ReferenceRead this manual carefully before you use this machine and keep it handy for future reference. For safe and correct use, be sure to read theSafety Information in "About This Machine" before using the machine.TransmissionOther Transmission FeaturesReceptionChanging/Confirming Communicatio …
Aficio MP C4500(298 pages) |
Intermec
SE 1223 Integrated VLD ScannerUSER’S GUIDE" " " " " " " " " " " " " " " " " " " " " " " " " " " "PN: 961-032-042Revision BSeptember 1999
…
SE1223(130 pages) |
Epson
Color Ink Jet PrinterColor Ink Jet PrinterDaily UsePrinted in Japan99.XX-XX4011290XXX-00Daily Use4011290 Rev.0 cover-F 4011290 Rev.0 cover-F PMS2654011290 Rev.0 cover-F DIC24254011290 Rev.0 cover-F DICF43 BK
…
Perfection 1270(83 pages) |
Fujitsu
Fujitsu Video Scanner Installation Procedures Windows 98SE\ME\2000\XP Rev051806A Page 1 of 3 If you are installing the following models by means of the Video interface then use this document. M3093E M3096E M3097DE M3099EH M3093EX M3096EX M3099A M4097D M3093DE M3097E+ M3099EX M4099D Hardware requirements. You will need a PC system that meets …
M3093DE(3 pages) |
Energy Power Tools Lawn and Garden Equipment HT6625#NH77J3: HT6625 Lawn and Garden Equipment Operation & user’s manual HT6625, 9 |
Gigabyte Motherboard GA-8IEXMotherboard #2J6G2N GA-8IEX, 80 |
Yamaha Motorcycle X MAX CZD300-AYamaha X MAX CZD300-A User Guide (Owner's manual), @GN9IRT X MAX CZD300-A, 114 |
Sony Amplifier XM-444WXM-444W Operating instructions - 7M6888 XM-444W, 4 |
Pentax Laser Level AL-M SeriesPentax AL-M Series Guide (Instruction manual), @54HWSG AL-M Series, 40 |
GE Microwave Oven JES2251SJJES2251SJ (Microwave Oven ePDF User Guide, #47STX5) JES2251SJ, 27 |
Craftsman Pressure Washer 580.752070580.752070 (Pressure Washer ePDF Manual, #N27V75) 580.752070, 60 |
Hitachi Drill DV14DL - 1/2" 14.4V HXP Li-Ion 3.0 Ah Hammer DrillHitachi DV14DL - 1/2" 14.4V HXP Li-Ion 3.0 Ah Hammer Drill User Manual (Doc Type: Drill Safety & instruction manual) DV14DL - 1/2" 14.4V HXP Li-Ion 3.0 Ah Hammer Drill, 88 |
In Phase Car Receiver IPS 520MPPDF User Guide (@I26245), In Phase IPS 520MP Car Receiver (Sun 11.2023) IPS 520MP, 22 |
JANE Stroller MUUMStroller Operation & user’s manual (JANE MUUM) MUUM, 168 |
Baxton Studio Indoor Furnishing Jennifer BD-02Indoor Furnishing #HE338P Jennifer BD-02, 2 |
Gemini Karaoke System GSYS-4000Gemini Product Guide: GSYS-4000 PDF Operation & user’s manual - 35466D GSYS-4000, 7 |