Manualios.com

Greenflame 15W Pellet Boiler Kw In Door & Outdoor Wood Pellet Boiler Installation, Operation And Servicing Instructions

  • 15W Pellet Boiler Boiler
  • mapuEpHQhZwIs
  • Kw In Door & Outdoor Wood Pellet Boiler Installation, Operation And Servicing Instructions
  • PDF / Adobe Acrobat Reader
  • 26

Greenflame 15W Pellet Boiler Manual Online:

3.8, 1369 votes
Greenflame 15W Pellet Boiler User Manual
Greenflame 15W Pellet Boiler User Guide
Greenflame 15W Pellet Boiler Online Manual

Text of Greenflame 15W Pellet Boiler User Guide:

  • ELECTRICAL CONNECTIONS Electrical installations should only be carried out by suitably qualified and certified electricians. If in doubt on any issue relating to the electrical connections on the appliance contact TR Engineering Technical Support or your local dealer for guidance before carrying out any connections. The Greenflame boiler must be supplied with a 2

  • Greenflame 15W Pellet Boiler, ERROR CODES In the unlikely event that the appliance fails to start or shuts down unexpectedly, then the Error code show on the display will give an indication as to the potential cause of the problem. Some of the errors can be cleared by the house holder and they are. Er01 - Water Safety Thermostat – Press the reset button A and then hold button B for three seconds to clear the error from the controller. Er03 - Accidental Extinguishing for Low Exhaust Temperature – Empty any un-burnt pellets from the burner pot and hold button B for three seconds. Er04

  • Greenflame 15W Pellet Boiler, Pre-Installation Considerations Pellets Wood pellets are manufactured by hot-extruding compressed sawdust which is produced during the working of natural dried wood. The compactness of the material comes from the lignin which is contained in the wood itself, and allows the production of pellets without the use of glues or binders. The market offers different types of pellet with characteristics which vary depending on what mixture of woods is used. The diameter varies between 6 mm and 8 mm, with a standard length in the range 5 mm to 30 mm.

  • Greenflame 15W Pellet Boiler, BOILER OPERATION & MAINTAINANCE The Greenflame has been developed to ensure that the user is able to carry out the most basic functions in a safe and convenient manner. Once the installation has been successfully carried out the user interaction is quiet simple from a regular inspection on the combustion chamber to remove ash to filling the hopper with pellets. Turning ON and OFF the boiler It is recommended that your boiler is controller by an external time clock. The time programs should be set to the times that heat is required at different periods throughout the day. You should al

  • Greenflame 15W Pellet Boiler, Besides the direction and force of the wind, the position of the flue and the cowl with respect to the roof of the building and the surrounding landscape is important. The wind also influences the operation of the chimney indirectly by creating high-pressure and low-pressure zones, not only outside the building but inside as well. In rooms directly exposed to the wind (2), an indoor high- pressure area can be created which can augment the draught in boilers, stoves and fireplaces, but it can be counteracted by the external high pressure if the cowl is situated on the side exposed to t

  • Greenflame 15W Pellet Boiler, PREPARING THE BASE Careful planning at an early stage will greatly help the installation process and make sure that all the required clearances are adhered to for servicing and that any potential issues with the routing of the flue can be resolved. The Greenflame pellet boiler should be positioned on a concrete plinth at least 50mm high and should project a minimum 100mm beyond the sides and the rear of the appliance and at least 600mm to the front. The plinth must be capable of supporting the weight of the appliance when full with fuel and the plumbing system has been filled wi

  • Greenflame 15W Pellet Boiler, WARNINGS AND GUARANTEE / WARRANTY INFORMATION. SAFETY INSTRUCTIONS Installation of the boiler, making the electrical connections, checking its operation, and maintenance are all tasks which should be carried out by qualified and authorised personnel. Install the boiler in accordance with the regulations in force in your local area, region and country. For the correct use of the appliance and to prevent accidents, the instructions given in this booklet must always be followed. Use, adjustment and programming

  • Greenflame 15W Pellet Boiler, TECHNICAL DATA Technical data GREENFLAME Nominal output kW 4.8 – 16.1 Nominal Fuel Input Kg/hr 1 – 3.5 Efficiency nominal Output (EN 303-5) % 90.7 Smoke Temperature at Nominal Power °C 130 - 150 Smoke Temperature at Reduced Power °C 70 - 90 Minimum Required Draft Pa 10 Exhaust Gas Mass Flow g/s 6 - 11 CO 2 at Reduced and Nominal Power % 6 - 12 Water Operating Temperature Range °C 50 - 85 Maximum Operating Pressure Bar/kPa 3 / 269 Recomm

  • Greenflame 15W Pellet Boiler, BOILER CONTROL PANEL SCHEMATIC Only authorised TR Engineering personnel may open the control board. Any tampering with the PCB will immediately invalidate the warranty.

  • Greenflame 15W Pellet Boiler, Where the appliance is to be installed indoors it is not permissible to install the appliance where another heating appliance is installed (fireplace, stove etc.) which does not have its own independent air intake. Locating the appliance in a room with an explosive atmosphere, e.g. workshop or tool shed, is prohibited. The floor of the room where the appliance is to be installed must be strong enough to take its weight. If the walls are not flammable, position the appliance with a clearance to the rear of at least 45 cm. For flammable

  • Greenflame 15W Pellet Boiler, WATER CONNECTIONS The diagram below indicates the plumbing connections at the rear of the boiler. The return connection is factory fitted with a 25/6 Standard pump Incorrectly sized expansion vessel will invalidate the warranty. A minimum 18 litre vessels is recommended for the boiler plus additional expansion for the heating and domestic hot water system. The boiler can be plumbed into either an open vented system (the maximum static hea

  • Greenflame 15W Pellet Boiler, SERVICE LOG DATE SERVICE PROVIDED SERVICE ENGINEER DATE SERVICE PROVIDED SERVICE ENGINEER DATE SERVICE PROVIDED SERVICE ENGINEER DATE SERVICE PROVIDED SERVICE ENGINEER DATE SERVICE PROVIDED SERVICE ENGINEER DATE SERVICE PROVIDED SERVICE ENGINEER DATE SERVICE PROVIDED SERVICE ENGINEER

  • OPERATING WARNINGS Shut the appliance down in the event of a breakdown or bad running. Pellets must not be fed manually into the burner. Accumulated un-burnt pellets in the burner after repeated failed ignitions must be removed before re-lighting. Do not wash the inside of the heat exchanger with water. Do not wash the appliance with water. The water could get

  • Greenflame 15W Pellet Boiler, BOILER HANDLING One of the key features of the E-Compact 15 is its size and ability to be transported to and located in confined spaces. Care should also be exercised when manoeuvring the appliance into position. The illustration below indicates the weight distribution of the appliance. Always protect the appliance when transporting on trollies or hand carts. Only persons who have been trained in manual handling techniques should attempt to move the appliance. Incorrect lifting techniques can cause serious injury.

  • Greenflame 15W Pellet Boiler, BOILER OPERATION AND MAINTENANCE Flue height to be determined on site as per building regulations.

  • Greenflame 15W Pellet Boiler, TR ENGINEERING LTD UNIT 7, NEWTON CHAMBERS WAY THORNCLIFFE INDUSTRIAL ESTATE CHAPELTOWN SHEFFIELD S35 2PH Tel: (0114) 2572300 Fax: (0114) 2571419 www.trianco.co.uk © TR Engineering Limited Copyright in this brochure and the drawings and illustrations contained in it is vested in TR Engineering Limited and neither the brochure or any part thereof may be reproduced without prior written consent. TR Engineering Limited's policy is one of continuous research and development. This may necessitate alterations to this s

  • Greenflame 15W Pellet Boiler, The secondary ash pan is located under the main combustion chamber. This needs to be emptied less frequently. Emptying the Ash Pan The boiler contains two areas where ash needs to be removed at regular intervals. The primary ash pan is located in the main combustion chamber. The frequency of emptying the ash pan is determined by the length of time the boiler has been running and under what load conditions. Once the ash in the ash pan has reached the top t

  • Greenflame 15W Pellet Boiler, CONTENTS PAGE INTRODUCTION 3 WARNINGS AND GAURANTEE / WARRANTY INFORMATION 4 SAFETY INSTRUCTIONS 4 OPERATING WARNINGS 5 GAURANTEE / WARRANTY INFORMATION 6 LIMITATIONS 6 EXCLUSIONS 6 PRE-INSTALLATION CONSIDERATIONS 7 PELLETS 7 CONSIDERATIONS FOR INSTALLATION 7 OPERATING AREA 7 CONNECTION TO THE FLUE 8 OPERATING PROBLEMS CAUSED BY DRAFT DEFECTS IN THE FLUE 8 - 9 PLUMBING PROBLEMS 10 INSTALLATION AND ASSEMBLY 10 UNPACKING 10

  • INTRODUCTION Dear Customer, We wish to thank you for choosing this Greenflame pellet boiler product from TR Engineering Ltd. In order to get the best performance from your appliance we recommend that you read this booklet carefully before lighting the appliance for the first time. While thanking you again, may we remind you that the appliance MUST NOT be used by childr

  • Greenflame 15W Pellet Boiler, CONTROL SYSTEM FUNCTION DESCIPTION BUTTON ON / OFF Function: Ignition, Extinguishing by pushing the button for 3 seconds until the acoustic signal. P2 UNBLOCK Function: Unblock. When the system is in Block by pushing the button for 3 seconds until the acoustic signal. MODIFY VALUES INTO MENU In modify mode change menus and submenus values. P4 P6 RUN ON MENU AND SUBMENU In menu run on submenu and menu. ESC Function: Exit managed pushing the button if in a menu or a submenu. Out of menu “Pump Test”. P1 MENU Function: Enter in menu or in a submenu. P3

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 GE PSIC3RGX Datasheet ge/psic3rgx-6N2.pdf 19 Apr 2023 5
2 Holmes HAPF624R Owner's manual holmes/hapf624r-W85.pdf 10 Sep 2023 2 0.89 Mb
3 Hitachi CP-S220W Operation & user’s manual hitachi/cp-s220w-3BT.pdf 02 Aug 2023 26 1.28 Mb
4 Topcon RL-200 2S Instruction manual topcon/rl-200-2s-1A5.pdf 01 Jan 2024 70 4.81 Mb
5 Moxa Technologies EDS-G509 Hardware installation manual moxa-technologies/eds-g509-12W.pdf 07 Sep 2023 15
6 Brookstone Wi-Fi Scanner Wand Operation & user’s manual brookstone/wi-fi-scanner-wand-85Y.pdf 09 Nov 2022 24 0.29 Mb

Similar Resources:

  • NTI

    Tft60 - 399

    (88 pages)
    Visit us online Trinity Tft Model Numbers: Tft60 - 399 Version Date: 2015-06-24 INSTALLATION AND OPERATION INSTRUCTIONS FOR TRINITY Tft BOILER TABLE OF CONTENTS 1.0 INTRODUCTION ................................................................................................................ 3 2.0 SPECIFICATIONS ...................... …
  • Bosch

    Singular 4000

    (20 pages)
    User ManualGas Condensing Combi BoilersSingularSingular 4000 | Singular 5200BTC 439003302 A / 03.2021 WARNING:If the information in these instructions are not followed exactly, a fi re or explo-sion may result causing property damage, personal injury or death. WARNING:Do not store or use gasoline or other fl ammable vapors and liquids in the vicinity of t …
  • Ferroli

    ATLAS D

    (120 pages)
    3540G651cod. 3540G651 — 05/2008 (Rev. 00)ATLAS DISTRUZIONE PER L’USO L'INSTALLAZIONE E LA MANUTENZIONEINSTRUCCIONES DE USO, INSTALACIÓN Y MANTENIMIENTOINSTRUÇÕES DE INSTALAÇÃO, UTILIZAÇÃO E MANUTENÇÃOINSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCEINSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIENAANWIJZINGEN VOOR G …
  • Viessmann

    VITODENS 050-W

    (4 pages)
    5513827 GB 8/2014Dispose after installation.Installation instructionsfor contractorsVIESMANNReplacing the gas trainfor Vitodens 050-WSafety instructionsPlease follow these safety instructions closely to prevent accidentsand material losses.Safety instructions explainedDangerThis symbol warns against therisk of injury.!Please noteThis symbol warns against the …
  • Gledhill Response

    BoilerMate OVR Series

    (44 pages)
    An open vented central heating and mains pressure hot water supply system incorporating a thermal storeDesign, Installation& Servicing InstructionsModel NumbersBMAS 150 OVRBMAS 180 OVRBMAS 220 OVRAll models comply with the Hot Water Associationspecication for integrated thermal stores …
  • Immergas

    EOLO Maior

    (40 pages)
    MAIOR EOLO 24 - 28 - 32Manual de instrucciones y advertenciasES*1.038763SPA*RU      Котел настенный газовый:MAIOR EOLO 32Тепловая мощность:мин: 12,2/14,8 kW макс.: 34,2 kWТип камеры …

Comments, Questions and Opinions: