Convia Type 3 Operating Instructions Manual
|
Convia Type 3, Wireless Smoke Detector (Type 3) Operating Instructions Version 1.0 For Marmitek alarm installations of the types: Homeguard MS8000, Security System MS9470, Security System MS9770, Protector28 Security System Base Station SC2700, SC2800
Convia Type 3, Page 2 of 12 Please read these instructions fully and completely before initial commissioning; they contain information for the correct installation of this innovative radio smoke alarm. © 2003 Convia GmbH, Germany All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical or chemical procedures without written permission of the publisher. This handbook may co
Page 3 of 12 Table of contents: Chapter: Page: 1. General and function......................................................................4 2. Intended use ................................................................................4 3. Safety- and maintenance- references................................................5 4. Installation pla
Convia Type 3, Page 4 of 12 1. General and function The optical smoke alarm is available as an optional extra for the Marmitek security systems of the types: Homeguard MS8000, security system MS9470, security system MS9770, Marmitek security system base station SC2700 and SC2800. It can detect incipient low temperature fires and open fires with smoke development and should be in installed every room. The smoke detector operates according to the dispersed light principle. For this a light transmitter and receiver are arranged in a measuring chamber in such a way that the transmitter light does not fall directly on the re
Convia Type 3, Page 5 of 12 3. Safety- and maintenance- references • Never open the equipment. It contains no parts to be waited. In the event of an error please give the smoke detector to your dealer. • Operate the equipment only in interiors and avoid the influence of dust, strong draft of air and direct sun light. • Clean the equipment with a dry linen cloth, which can be easily dampened. • Never use any kind of cleaning agents. • The system may not be kept / operated within the access range by children. It is not a toy! 4. Installation places Smoke detectors should be installed in accordance with the NFPA Standard 74 (National
Convia Type 3, Page 8 of 12 The smoke detector should be installed in the centre of the room, on the ceiling, or for a sloping roof at the highest point, as smoke rises and gathers in this area. This guarantees the earliest possible alarm warning. Smoke alarms should be installed in all rooms, but not directly above the cooking area in the kitchen or the bath, where dust concentrates. Ensure that the smoke detector is not installed directly on or in the vicinity of large metal objects as they can affect the radio range. 5. Installation Please follow these steps to install the Convia smoke detector: • At the place where yo
Convia Type 3, Page 9 of 12 • Using the two screws and plastic wall plugs (all supplied), attach the bracket to the wall. • Line up the slot of the backet and the detector. Push the detector onto the mounting bracked and turn it clockwise to fix it into place. Pull outward on the detector to make sure it is securely attached to the mounting bracket. • Do not insert the battery at this stage (9V). Please follow the steps of the next chapter before you insert the battery. • How to install the battery: • The smoke detector
Convia Type 3, Page 10 of 12 6. Registering the smoke detector with the base stations of the types „MS9470“, „MS9770“, „SC2700“, „SC2800“ Carry out the following steps: (Every time you press a key you hear a short confirmation beep) 1. Open the lid on the right side of the base station. 2. Set the mode switch to the INSTALL position. All indicators of occupied zones come on. 3. Place the battery (9V) in the correct polarity in the battery holder of the smoke detector. The smoke alarm sends a radio signal to the base station: The LED
Convia Type 3, Page 11 of 12 7. Registering the smoke detector with the base station of the type „Homeguard MS8000“ Carry out the following steps: (Every time you press a key you hear a short confirmation beep) 1. Open the lid of the Homeguard. 2. Key in your PIN-code (factory default: 0000). If the code is correct you will hear a longer confirmation beep. The green LED should start to flash. (Otherwise you did not key in the correct PIN-code.) 3. Press the 1 key to set the Homeguard to learning-mode. 4. Place the battery (9V) in the correct polarity in the battery holder
Convia Type 3, Page 12 of 12 8. Final assembly The lower section of the smoke detector is attached to the bracket already mounted on the ceiling and turned clockwise to the stop. 9. Convia smoke detector - technical data Frequency: 433,92 MHz Modulation: AM Range: 30 to 50 meters (free field) Alarm: 85 dB Power supply: 9V-Blockbattery, Alkaline-Type Operating temperature: 10 to 45 degrees (Celsius) Air moisture: < 95% rel. air moisture © 2003 Convia GmbH
Omega Engineering Four Zone Temperature OMA-VM520 Smoke Alarm Manual and installation instructions
Four Zone Temperature OMA-VM520 |
Visonic MCT-425 Smoke Alarm Brochure
MCT-425 |
Panasonic EBL128 Smoke Alarm Operating instructions manual
EBL128 |
Marmitek SD90 Smoke Alarm Owner's manual
SD90 |
Watchguard SMODETI240 Smoke Alarm Operation & user’s manual
SMODETI240 |
Kidde 0916E Smoke Alarm Brochure & specs
0916E |
First Alert SA320CN Smoke Alarm Specifications
SA320CN |
Ei Electronics Ei100L Smoke Alarm Product manual
Ei100L |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Wincor Nixdorf | BEETLE iDOT | Operating manual | wincor-nixdorf/beetle-idot-1OX.pdf | 07 Jul 2022 | 28 | |
2 | ClearSounds | A1600BT | Setup manual | clearsounds/a1600bt-5CE.pdf | 13 Sep 2023 | 2 | 1.48 Mb |
3 | PCE Instruments | PCE-PFM 2 | Operation & user’s manual | pce-instruments/pce-pfm-2-85N.pdf | 29 Apr 2023 | 16 | |
4 | VeriFone | MX850 | Brochure | verifone/mx850-237.pdf | 18 Oct 2023 | 2 | 0.48 Mb |
5 | Fanimation | FP1620 | Owner's manual | fanimation/fp1620-J3H.pdf | 08 Dec 2022 | 14 | 1.39 Mb |
6 | ProForm | PRO 4500 | Operation & user’s manual | proform/pro-4500-HG1.pdf | 18 Oct 2022 | 40 |
Wheelock
Technical Manual for theStrobe – XB15ULPlease note that every care has been taken to ensure the accuracy of our technical manual. We do not, however, accept responsibility for damage, loss or expense resulting from any error or omission. We reserve the rightto make alterations in line with technical advances and i …
MEDC XB15UL(4 pages) |
NTI
E-NLS Noise Level Sensor Installation Instruction The E-NLS noise level sensor that can be used to detect sounds and report occurrences through the user interface of an E-2D,-5D or -16D Enterprise Environment Monitoring System (SYSTEM). Connect the sensor to an available RJ45 Sensor port on a SYSTEM and configure the SYSTEM to report and send alerts …
ENVIROMUX Series(2 pages) |
no-flame
…
83284(17 pages) |
Ei Electronics
Open unit by sliding cover up as shown in figure 1. Thenremove the terminal block cover screw.What to do when the Alarm sounds:(1) Open the doors and windows to ventilate.(2) Turn off the appliance where possible and stop usingthe appliance.(The alarm can be silenced immediately bypushing the test/hush button if the level is below 150ppm CO).(3) Evacuate the …
Ei 225E(6 pages) |
Kidde
9 Volt Battery Operated Photo Electric/ Ionization Smoke Alarm with“HUSH” Control to temporarily silence nuisance alarms, and alarmmemory.Thank you for purchasing this smoke alarm. It is an important part ofyour family’s home safety plan. You can trust KIDDE Safety to providethe highest quality safety products. We know you expect nothing lesswhen th …
PI 9000(2 pages) |
LST
© LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVEDFWI016-1_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.Fire Brigade InterfaceFWI016-1DescriptionThe Fire Brigade Interface FWI016 allows for the con-nection of two …
FWI016-1(1 pages) |
Pioneer Receiver VSX-1015-SPioneer Receiver Service manual (File: pioneer-vsx-1015-s-service-manual-140, 24th Nov 2023) VSX-1015-S, 140 |
Sony Laptop PCG-808PDF Guide (@6354BY), Sony PCG-808 Laptop (07/09/2023) PCG-808, 144 |
Sunbeam Iron 3016Sunbeam Iron 3016 Instruction manual 3016, 13 |
Sony Switch MVS-8000X SystemMVS-8000X System (Switch ePDF User Guide, #DKT7DB) MVS-8000X System, 566 |
ProForm Other 1095 Zlt TreadmillProForm 1095 Zlt Treadmill User Guide (Manual ), @24ORKI 1095 Zlt Treadmill, 28 |
Robin Engine EH09DRobin EH09D Guide (Service manual), @XK3VWO EH09D, 84 |
Sangean Portable Radio PR-D9CLSangean Product Guide: PR-D9CL PDF Operation & user’s manual - 324Y8Z PR-D9CL, 18 |
Smeg Blender BLF01BLF01 Operation & user’s manual - 2MIWS2 BLF01, 24 |
ITRON Handhelds FC300FC300 Operation & user’s manual - 58465O FC300, 40 |
Sylvania VCR 2960LVVCR Owner's manual (Sylvania 2960LV) 2960LV, 52 |
Lenovo Desktop ThinkCentre M81Desktop PDF Operation & user’s manual ThinkCentre M81, 140 |
Vivint Wireless Router WR01Vivint Product User Manual: WR01 PDF Quick start manual - 8VG5C8 WR01, 10 |