Technoware ECO 0.50 Operation & User’s Manual
|
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 1 User’s manual Index Safety Warnings ................................................................................ 2 1 Introduction ................................................................................. 3 2 General Characteristics ................................................................... 3 3 Receipt and site selection ................................................................ 4 4 EXTERNAL DESCRIPTION .............
Technoware ECO 0.50, User’s manual 2 UPS ECO 0.50 – 0.70 – 0.90 – 1.1 – 1.3 Safety Warnings Read this manual carefully and completely before installing and using the TECNOWARE ECO Uninterruptible Power Supply, which, from here after, will also be referred to as UPS. This manual should be kept close to the UPS and read before the UPS is installed and used. The UPS must be used only by properly trained personnel. To ensure correct and safe operations, it is necessary that operators and maintenance personnel observe the general safety Standards as well a
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 3 User’s manual 1 Introduction ECO is an UPS (Uninterruptible Power Supply) specifically designed to protect your computer from any type of irregularities in the AC line (such as black-outs, under or over voltages, micro-interruptions), which often cause damage to your Hardware and Software. Under normal AC line condition, ECO filters frequently occurring electrical disturbances (such as transients, spikes, interferences, etc.), thus protecting all devices connected to the outlets, and recharging the batteries in an
Technoware ECO 0.50, User’s manual 4 UPS ECO 0.50 – 0.70 – 0.90 – 1.1 – 1.3 • Visual and acoustic signals indicating operating mode and alarm/fault conditions. • High efficiency • Maximum reliability • Smart design and easy to use 3 Receipt and site selection Carefully remove the UPS from its packaging, and carry out a meticulous inspection. We recommend keeping the original packaging in a secure place, in case you need to send the UPS for maintenance purposes. In case of t
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 5 User’s manual 4 EXTERNAL DESCRIPTION 4.1 Front Panel The front panel informs the user about operating status, alarm conditions through 2 leds. On the front panel there are (see figure 1): 1. The ON/OFF button: enables the user to turn ON/OFF the UPS. 2. The LINE/BATTERY led: this led (blue color) is always on during the functioning in Normal Mode, it flashes one time every 4 seconds in Battery mode and it flashes one time every second in Low Battery condition. 3. The ALARM led: this led (red color) is on to indicate Alarm/Fault condition. Fi
Technoware ECO 0.50, User’s manual 6 UPS ECO 0.50 – 0.70 – 0.90 – 1.1 – 1.3 4.2 Rear Side Figure 2 – Rear Side On ECO rear side there are (see figure 2): 1. Grounded AC Input power socket: IEC C14 type; to connect the UPS to the AC utility line. 2. Input fuse: electrical specification: max current 5 A, voltage 250 V. 3. Grounded UPS Output receptacles: IEC C13 type. 5 Electrical Installation and First Start Up We advise you to follow the steps below explained for greater safety
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 7 User’s manual 4. Switch the UPS off (by pressing again the ON/OFF button for about 2 seconds). 5. Connect the devices to be supplied to the UPS outputs, by using only the included cables. Be sure all the devices have the main switch in ON position. 6. Turn on the UPS again. Check that it starts working correctly and it doesn’t signal any sort of anomaly. Moreover be sure that all the devices connected to the UPS outputs are working correctly. 7. Simulate a black-out by removing the AC Input line. The UPS starts working in Battery mode: the UPS
Technoware ECO 0.50, User’s manual 8 UPS ECO 0.50 – 0.70 – 0.90 – 1.1 – 1.3 6.2 Battery Mode The UPS automatically runs in Battery mode if the AC Input Line voltage amplitude gets out of security limits (in case of a black-out or over-voltage/low-voltage): in this case, the UPS supplies the required output power by its internal battery and by the Inverter block. The UPS automatically returns in Normal mode a few seconds after the AC Input Line is recovered. In Battery mode the UPS emits an acoustic alarm signal every 4 seconds and simultaneously the LINE/BATTERY led flashes. 6.3 Low Battery and Automatic Restart In Battery mode, ECO indicates the Low Battery co
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 9 User’s manual 7 Technical Characteristics UPS ECO Model 0.50 0.70 0.90 1.1 1.3 Power 500 VA (300 W) 700 VA (420 W) 900 VA (540 W) 1100 VA (660 W) 1300 VA (780 W) Recommended for: Personal Computer with 350W PSU (250W real power) + LCD Monitor (40W) Personal Computer with 450W PSU (350W real power) + LCD Monitor (40W) Personal Computer with 550W PSU (450W real power) + LCD Monitor (60W) Personal Computer with 600W PSU (500W real power) + LCD Monitor (60W) Personal Computer with 650W PSU (550W real power) + LC
Technoware ECO 0.50, User’s manual 10 UPS ECO 0.50 – 0.70 – 0.90 – 1.1 – 1.3 8 Maintenance 8.1 UPS Cleaning Before starting any cleaning operation, be sure that: 1. The AC Input Voltage for the UPS has been removed. 2. The UPS is OFF. Use only a cloth dampened with water to clean the unit. If UPS works in an environmental unusually dusty or dirty, remove the dirty from the ventilation holes. Before restarting the UPS be sure it is completely dry. If any liquid gets inside the UPS, do not start the unit and contact Technical Service immediately. 8.
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 11 User’s manual Battery replacement must be performed exclusively by qualified technical personnel authorized by TECNOWARE. TECNOWARE declines any responsibility if this warning is disregarded. When replacing batteries, replace with the same type and number. CAUTION: A battery can present a risk of electrical shock and high short circuit current. The following precautions should be observed when working on batter
Technoware ECO 0.50, User’s manual 12 UPS ECO 0.50 – 0.70 – 0.90 – 1.1 – 1.3 9 Troubleshooting Alarms and problems you may encounter during operating the UPS are given in the table below. Apply the suggestions corresponding to each anomaly as described into the table. If your anomaly is excluded or the suggested actions do not solve your problem, consult the Technical Service. Please give the following information to the Technical Service: Model and serial number of the UPS, which can be found on the nameplate on the rear of the UPS. Description of anomaly. Risk of electric shock: do not remove the c
Technoware ECO 0.50, UPS ECO 0.50 – 0.70 – 0.90 – 1.1 - 1.3 13 User’s manual Conformity to the European Directives TECNOWARE S.r.l. confirms that ECO models comply with the requirements set out in: the Low Voltage Directive (Safety) 2006/95/EC and following amendments, the EMC (Electro-Magnetic Compatibility) Directive 2004/108/EC and following amendments. The following standards were applied: Low Voltage Directive (Safety): CEI EN 62040-1: 2009 EMC Directiv
Tripp Lite SMART3000RMXL2U UPS Owner's manual
SMART3000RMXL2U |
Mustek PowerMust 1000 On Line(1K) UPS Operation & user’s manual
PowerMust 1000 On Line(1K) |
Effekta RMH 700 UPS Instruction manual
RMH 700 |
Delta ups302R2002N035 UPS Installation & operation manual
ups302R2002N035 |
GE LP 31 UPS Operating manual
LP 31 |
Sola 750 VA UPS Operation & user’s manual
750 VA |
PowerShield defender PSD 650 UPS Operation & user’s manual
defender PSD 650 |
Technoware ERA LED 1.5 UPS Operation & user’s manual
ERA LED 1.5 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | HP | D5970A - NetServer - LCII | Installation manual | hp/d5970a-netserver-lcii-R7X.pdf | 14 Aug 2023 | 203 | 1.78 Mb |
2 | JVC | GZ-HM1SEK | Instructions manual | jvc/gz-hm1sek-SD3.pdf | 10 Jan 2024 | 44 | |
3 | Shaw | ATLAS PVR Universal Remote Control | Operation & user’s manual | shaw/atlas-pvr-universal-remote-control-L6O.pdf | 13 Jul 2023 | 44 | 3.22 Mb |
4 | Remington | H365 | Operation & user’s manual | remington/h365-GPD.pdf | 01 Jan 2024 | 10 | |
5 | Vector | Start-IT VECO21 ST | Owner's manual | vector/start-it-veco21-st-YP9.pdf | 26 Aug 2023 | 14 | |
6 | Emerson | EDVC860F | Owner's manual | emerson/edvc860f-PY2.pdf | 19 Jun 2023 | 28 | 1.17 Mb |
Tripp Lite
Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART750USBSmart USB 750VA Tower Line-Interactive 120V UPS with USB port Highlights750VA tower 120V line interactive UPS Corrects brownouts as low as 89V without using battery power3 UPS battery supported outlets, 3 surge-only outletsUSB por …
Line-Interactive UPS System SMART750USB(5 pages) |
EMC2
1This document describes how to replace an Uninterruptible Power Supply (UPS) that is connected to an AX100 (dual-SP) storage system. Topics include◆ Before You Start .....................................................................................2◆ To Replace the UPS................................................................................2� …
AX100 Series(4 pages) |
Xtreme
P90L Online UPSP90L-1500, 2000, 3000 ModelsUser & Installaon Manual © 2015 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 4/08/15)For more information, visit www.247technology.com/single-phaserackmounttower-ups/xtreme-power-conversion-p90
…
P90L-1500(50 pages) |
PowerWalker
ENGLISH PowerWalker VI 500-1500 THID Quick Guide I. Front Panel: 1. ON/OFF button 2. Scroll down button 3. Mute button 4. LCD display 1. UPS ON 2. AVR mode 3. Battery mode 4. Internal fault 5. Output load level 6. Battery level 7. Input measurements 8. Output measurements 9. Measuring unit II. Rear Panel: VI 500T/750T VI 1000T/1500T …
VI THID Series(4 pages) |
Trust
Türkçe 中文 Български Česky Dansk DeutschΕλληνικά EnglishEspañol Français Italiano MagyarNederlands Norsk Polski Română Русский Slovenčina Suomi Português Svenska User’s manual Version 1.0 PW-5040S 400VA UPS / PW-5060S 600VA UPS 15833 / 15899
…
PW-5060S 600VA UPS(87 pages) |
Salicru
NOTA:ES OBLIGATIORIO CONSERVAR ESTE MANUAL TÉCNICO A MANO Y ACCESIBLE POR TODO ELPERSONAL RELACIONADO CON EL SAI.IT IS MANDATORY THIS TECHNICAL HANDBOOK IS HOUSED IN A PLACE KNOWN TO THEPERSONNEL OPERATING ON THE UPS, SO THAT THEY CAN FIND AND USE IT ANY MOMENT .Manual de Instalación y OperaciónInstallation and Operation ManualSISTEMA DE ALIMENTACIÓN INI …
SLC ELITE MAX Series(80 pages) |
Franklin Wireless Wireless Router U301U301 Quick start installation manual - OFN244 U301, 5 |
Tascam DJ Equipment XS-3Owner's manual for Tascam XS-3 DJ Equipment XS-3, 32 |
Panasonic Fax Machine KX-FC228FXFax Machine #8T467A KX-FC228FX, 76 |
Whirlpool Washer 3951059CUser Manual: Whirlpool 3951059C (22SM8E, Upd.02/10/2023) 3951059C, 39 |
Hakko Electronics Touchscreen Monitouch S8 SeriesHakko Electronics Monitouch S8 Series User Manual (Hardware specification), @FOU89D Monitouch S8 Series, 79 |
Electrolux Oven EOB 395Instruction booklet for Electrolux EOB 395 Oven EOB 395, 12 |
Samsung Cell Phone GT-E2232Cell Phone PDF Operation & user’s manual GT-E2232, 2 |
Roland Security Sensors udk20#S9P7DZ: udk20 Security Sensors Manual udk20, 112 |
Korenix Network Router 7850G-2XGNetwork Router PDF Operation & user’s manual 7850G-2XG, 1246 |
Craftsman Lawn and Garden Equipment EZ 917.273111Lawn and Garden Equipment #7H7UGM EZ 917.273111, 64 |
D-Link Modem DSL-300GUser Guide: D-Link DSL-300G (JLMY1W, Upd.Tuesday 19-12-2023) DSL-300G, 42 |
Quartet Whiteboard IdeaShare#UG1X64 IdeaShare: Quartet Whiteboard Owner Documentation IdeaShare, 29 |