  • ONEAC ON Series, Features and Specifications 18 ON Series e UPS User Instruction Manual Table 2. ON Series e 200 Wall-mount Extendable Runtimes Typical Runtime by System Load ONe200X Two 12 V, 7 AH Batteries Plus1 External Battery Plus2 External Batteries Plus 3 External Batteries Plus 4 External Batteries Plus 5 External Batteries VA LOAD RUNTIME (HOURS:MINUTES) 75 VA 1:32 6:32 12:25 — — — 100 VA 1:09 5:10 9:55 — — — 150 VA 0:40 3:33 6:49 10:19 — — 200 VA 0:30 2:35 4:53 7:37 9:49 — NOTE: Due to application specifi

  • Battery Considerations 22 ON Series e UPS User Instruction Manual fig. 9: ON Series e Wall-mount UPS Battery Replacement Replacing External Battery Enclosure(s) For additional runtime, some ON Series e UPSs supportsextra batteries housed in a separate enclosure. The UPS power module and battery enclosure(s) are shipped separately. NOTE:The UPS and attached loads may remain powered ON during

  • ONEAC ON Series, Warranty 26 ON Series e UPS User Instruction Manual Warranty ONEAC products are warranted free from defects in materials and workmanship for five years. This warranty is limited to repairing or replacing, at ONEAC’s option, any defective component, circuit board, or module contained within the product only when it is returned with an ONEAC Return Material Authorization (RMA) number to ONEAC or to an ONEAC-designated repair facility. In all cases, the customer is responsible for shipping charges to and from ONEAC or the ONEAC-designated repair facility. Batteries Certain modules or peripherals included with the product, but not manufactur

  • Set-up and Installation 4 ON Series e UPS User Instruction Manual Set-up and Installation When selecting a location for your UPS, be sure that the unit is near a properly wired AC electrical outlet and is easily accessible for all other connections: equipment to UPS, optional battery enclosure(s) and/or optional communications cable. NOTE: Whe

  • ONEAC ON Series, Set-up and Installation ON Series e UPS User Instruction Manual 11 power switch to the “OFF” position, remove the load and push the breaker back into its housing (see fig. 6). If the electronic overload has tripped, the UPS will have to be reset by toggling the power switch “OFF”, then “ON” to restore output power. fig. 6: ON Series e UPS Circuit Breakers Battery Replacement If the UPS has determined that the battery is no longer functional, the green and red LEDs will be on continuously and the yellow LED will flash. The audible alarm will sound every five minutes. Indicator Lights

  • Features and Specifications ON Series e UPS User Instruction Manual 19 Safety & Approvals Table 3. Emissions Test Regulations Emissions Test Regulations United States 47 CFR Part 15 Subpart A Canada Interference-Causing Equipment Standard (ICES-003 Issue 2, Rev.1) Table 4. Safety Regulations Safety Regulations United States UL1778 (Uninterruptible Power Supply Equipment) Cana

  • ONEAC ON Series, Set-up and Installation ON Series e UPS User Instruction Manual 13 The shell of the interface connector is connected to the UPS chassis ground reference. fig. 7: ON Series e Interface Port Pin No. Signal 1 Low Battery - normally open 5 Line Fail - RS-232 static levels 7 Signal Ground 8 Low Battery - RS-232 static levels 10 Line Fail - normally open 18 Line Fail - normally closed 20 Shutdown (to UPS) 25 Low Battery - normally closed Interface Port Interface PortInterface Port ON Series e 400 - 600 ON Series e 200 -300 ON Series e Wall-Mount

  • ONEAC ON Series, Features and Specifications 14 ON Series e UPS User Instruction Manual Features and Specifications Your ONEAC ON Series UPS features full output isolation and power conditioning with Virtual Kelvin Ground ® output filtering. This provides the highest level of protection from power line disturbances available. Intelligent battery management system includes: • Five-year warranty on power control systems • Two-year warranty on batteries • Battery condition monitoring and status alerts • Low battery indication • Hot

  • ONEAC ON Series, Set-up and Installation ON Series e UPS User Instruction Manual 5 CAUTION: Interruption of the protective grounding conductor or disconnection of the protective earth terminal presents a potential shock hazard that could result in personal injury and damage to the equipment. Set-up Mounting Wall-mount Extended Runtime Units and Battery Enclosure(s) Mount the power unit and battery enclosure(s) on a 3/4 inch plywood (minimum) backboard. Use the enclosed four (4) 1/4 inch x 1 inch slotted-hex, washer-head wood screws. (See fig. 1) NO

  • ONEAC ON Series, Features and Specifications ON Series e UPS User Instruction Manual 17 Typical Runtime Table 2. Runtime for the ON Series e 200, 300, and 400 VA Desktop UPS Typical Runtime by System Load ONe200 One12 V, 7 AH Battery ONe200D Two 6 V, 10 AH Batteries One300 One 12 V, 7 AH Battery ONe300D Two 12 V, 7 AH Batteries ONe400D Two 12 V, 7 AH Batteries VA LOAD RUNTIME (HOURS:MINUTES) 75 VA 0:28 0:53 0:41 1:32 1:15 100 VA 0:18 0:37 0:21 1:09 1:05 150 VA 0:12 0:25 0:16 0:40 0:50 200 VA 0:08 0:16 0:10 0:30 0:35 250 VA NA NA 0:07 0:20 0:25

  • ONEAC ON Series, Set-up and Installation ON Series e UPS User Instruction Manual 7 3. Repeat step 2 to connect additional external battery enclosures. fig. 2: ON Series e Wall-mount UPS and External Battery Connections Desk-top External Battery Enclosure(s) For additional runtime, some ON Series e UPSs can use extra batteries housed in a separate enclosure. Use only ONEAC model ONEXBC-217. The UPS power module and battery enclosure(s) are shipped separately. 1. Connect the battery cable from the closest battery enclosure to the external battery receptacle on the UPS, see fig. 3. 2. Connect the

  • ONEAC ON Series, Set-up and Installation ON Series e UPS User Instruction Manual 9 2. Insert the connector(s) from the equipment to be protected into the 5-15R receptacles on the back of the UPS. NOTE: ALL AC power supply cords from each component in the system to be protected must be connected to the UPS or complete protection will not be achieved. 3. Insert the UPS’s 5-15P plug into a properly grounded and wired AC receptacle. 4. With the UPS connected to a properly wired AC input power source, toggle the power switch to the ( | ) “ON” position. Power is immediately supplied to the output connectors. The ON Series e will perform a self-test when turne

  • ONEAC ON Series, Set-up and Installation 12 ON Series e UPS User Instruction Manual Communications (Factory Installed Options) The Basic Interface Port Option (see fig. 7) will send On Battery and Low Battery signals to the host computer. It will also accept a shutdown inverter signal to conserve battery life. Pins 5 and 8 are RS-232 static levels. Less than five (5) volts indicates a normal or not true condition. Greater than five (5) volts indicates an alarm or true condition. Pins 1, 10, 18, and 25 (simulated relay closures) are open drain FET transistor outputs which must have a pull-up resistor to

  • ONEAC ON Series, Features and Specifications ON Series e UPS User Instruction Manual 15 Specifications and Characteristics Specification and Characteristics ONe200A ONe300A ONe400A ONe600A Part Numbers (single battery) (double battery) (wall-mount) ONE200A-SB ONE300A-SB NA NA ONE200DA-SB ONE300DASB ONE400DA-SB ONE600XA-SB ONE200XA-W-SB ONE300XA-SB NA NA Maximum Load VA/W 200/135300/200 400/265 600/400 Load Power Factor Range UPS .65 to 1.0 - will support loads rated 0.5 to 1.0 Crest Factor <3 Nominal Input Voltage 120 VAC Low Limit for On-line Operation 85 VAC High Limit for On-line Operation 135 VAC

  • ONEAC ON Series, Set-up and Installation 8 ON Series e UPS User Instruction Manual Repeat step 2 to connect additional external battery enclosures. fig. 3: ON Series UPS and External Battery Connections Connecting Equipment to the UPS Before beginning, shut down and unplug the equipment to be protected. DO NOT make any connections or attempt to use any of the equipment until all the following connection instructions have been reviewed and completed. The UPS is equipped with a six foot attached line cord with a 5-15P plug. The 200 and 300

  • ONEAC ON Series, Troubleshooting ON Series e UPS User Instruction Manual 25 If you have questions or problems regarding you ON Series e UPS, refer to the troubleshooting table below. Table 5. Troubleshooting Problem Possible Cause Solution UPS will not turn ON Front Panel Switch not “ON”. Switch the Power Switch to (I) UPS’s input circuit breaker tripped. Reduce the load on the UPS by unplugging the load and press the circuit breaker in on the rear panel. Unit not plugged in. Plug unit into wall outlet. UPS operates on battery even with line voltage present. UPS’s input circuit breaker tripped. Reduce the load on the UPS by unplug

  • ONEAC ON Series, Features and Specifications 16 ON Series e UPS User Instruction Manual Output Type open drain “N” channel FET 2N7000 or equivalent Operating Temperature 0 to +40° C (32 to 104° F) Storage Temperature -15 to 45° C (+5 to 113° F) Relative Humidity 0 to 95%, non-condensing Operating Elevation 0 to 3,000 m (0 to 10,000 ft.) Storage Elevation 0 to 15,000 m (0 to 50,000 ft.) Desk-top UPS (HxWxL) in. 7.4 x 6 x 15 7.4 x 6 x 15 7.8 x 7 x 16 7.8 x 7 x 16 (19 x 15 x 38) (19 x 15 x 38) (20 x 18 x 41) (20 x 18 x 41) Desk-top UPS Shipping Weights lbs. (kg)

  • ONEAC ON Series, UPS Disposal 24 ON Series e UPS User Instruction Manual UPS Disposal Once your UPS has reached the end of its useful life and it is necessary to dispose of the unit: 1. Remove the batteries as instructed in Replacing Battery(ies): Standard and Wall-mount Units on page 20. 2. Dispose of the batteries as instructed in Battery Disposal on page 23. 3. Dispose of the unit in accordance with local/ national recycling or disposal ordinances. Troubleshooting ONEAC offers 24-hour technical support. If you ha

  • ONEAC ON Series, ON Series ® e UPS For use with ON Series e 200 - 600 VA, 60 Hz model ONEAC Corporation, a wholly owned subsidiary of Chloride Group, PLC was founded in 1979. ONEAC designs and manufactures products that provide the highest level of protection against power and data line disturbances, regardless of conditions. ONEAC's comprehensive product lines include power conditioners, uninterruptible power supplies, DC power solutions and voice & data line protection devices. With ISO9001 certified manufacturing plants in the U.S. and U.K., ONEAC is dedicated to demand-flow manufacturing and the highest quality standards. Organizations whose productivity goals allow n

  • ONEAC ON Series, Battery Disposal ON Series e UPS User Instruction Manual 23 For wall mounted batteries, after disconnecting ALL battery cables, remove the two lower mounting screws under the battery cabinet. Then lift the cabinet straight up to disengage from the upper two mounting screws (see fig. 11). fig. 11: ON Series e Wall-mount UPS Battery Replacement Battery Disposal UPS batteries contain toxic and acidic materials. Disposal method must adhere to local/national recycling laws. Dispose of the battery in one of three ways: 1. Return batteries prepaid to ONEAC for proper recyclin

  • ONEAC ON Series, Safety ON Series e UPS User Instruction Manual 3 Safety WARNING: This equipment services power from more than one source. The output receptacles may have voltages present even when the unit is unplugged. UPSs present a different safety issue than most electrical equipment because unplugging the UPS puts it into backup mode. Unplugging the UPS does not remove the electrical charge. To ensure that the UPS is off, turn the power switch “OFF” before unplugging the UPS from the wall outlet. CAUTION: This unit is intended to be used in a system that has a grounded neutral conductor. CAUTION: Operating this equipment without proper grounding may present a

  • ONEAC ON Series, ON Series e UPS User Instruction Manual i Introduction .......................................................................................1 Registering Your ONEAC UPS .............................................................1 Technical Support ...............................................................................1 FCC Compliance ................................................................................2 Safety .................................................................................................3 Set-up and Installation ..........................................

  • ONEAC ON Series, ON Series e UPS ON Series e UPS User Instruction Manual ON Series e UPS User Instruction Manual IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS. Please read and save these instructions. This manual contains important instructions for the ON Series e UPS. Follow these instructions during the unpacking, installation and maintenance of the ON Series e UPS. If you have a problem with the unit, please refer to Troubleshooting on page 24 before calling ONEAC Technical Services. Licenses and Trademarks ONEAC, ON Series, ONBoost, and Virtual Kelvin Ground are all registered trademarks of ONEAC Corporation. All other trade

  • Set-up and Installation 6 ON Series e UPS User Instruction Manual 3. Drill a 3/16 inch diameter hole at each screw location. 4. Drive the screws into the backboard at the screw locations. Allow a 1/8 inch gap between the screw head and the backboard. 5. Mount the unit by sliding the keyhole slots, located on the back of the enclosure, over the screws. 6. C

  • ONEAC ON Series, FCC Compliance 2 ON Series e UPS User Instruction Manual FCC Compliance ATTENTION: Changes or modifications to this unit not expressly approved by the party responsible or in FCC compliance could void the user’s authority to operate the equipment. This equipment was tested and complies with the limits for a Class A digital device, pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the UPS is operating in a commercial envi

  • ONEAC ON Series, Introduction ON Series e UPS User Instruction Manual 1 Introduction Thank you for selecting this uninterruptible power supply (UPS). ONEAC’s ON Series offers the most reliable protection from the harmful effects of electrical line disturbances for your computing and communications equipment. ONEAC’s ISO 9001 certification represents our commitment to building world-class products. We take pride in every unit that leaves our manufacturing facility Registering Your ONEAC UPS To ensure that your ON Series e UPS model and serial number are registered, complete and m

  • ONEAC ON Series, Battery Considerations 20 ON Series e UPS User Instruction Manual Battery Considerations Replacing Battery(ies): Standard and Wall-mount Units NOTE:To obtain new battery(ies), contact ONEAC Technical Services at (847) 816-6000, or toll free at (800)-327-8801, opt. 3. In Europe, dial +44 (0) 2380 610311 Battery replacement is a safe procedure that is isolated from electrical hazards. You can leave the UPS and attached loads powered “ON” during the procedure. If the unit is “ON,” the audible alarm will sound when the battery is disconnected and the yellow and red LEDs will blink

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Devolo Dlan Manual  devolo/dlan-89O.pdf 16 Sep 2022 49 0.82 Mb
2 Mercedes-Benz MBU-1000 Installation and operation manual mercedes-benz/mbu-1000-9U4.pdf 22 Feb 2024 11
3 Yamaha VK540EK Owner's manual yamaha/vk540ek-X95.pdf 04 May 2023 76 4.25 Mb
4 Zte Blade S6 Quick start manual zte/blade-s6-48Q.pdf 13 Dec 2023 184
5 Asus MAXIMUS VII IMPACT Operation & user’s manual asus/maximus-vii-impact-BL7.pdf 29 Dec 2023 238
6 Whirlpool LE5780XM Use and care manual whirlpool/le5780xm-M3J.pdf 07 Mar 2023 12 0.7 Mb

Similar Resources:

  • CyberPower

    OLS1000ERT2U

    (18 pages)
    User’s Manual OLS1000ERT(XL)2U OLS1500ERT(XL)2U OLS2000ERT(XL)2U OLS3000ERT(XL)2U CyberPower Systems Inc. www.cpsww.com K01-C000045-00 …
  • Dale Power Solutions

    E200 Series

    (36 pages)
    Dale Power Solutions Ltd Salter Road, Eastfield Industrial Estate, Scarborough, North Yorkshire, YO11 3DU, UK [email protected] | www.dalepowersolutions.com | +44 (0) 1723 583511 S5264FU02 Rev 3 Dale Power Solutions Ltd User Manual E200 Series UPS E206(E) E2010(E) …
  • Phasak

    6000

    (68 pages)
    Sistema de Alimentación IninterrumpidaSistema de Alimentação IninterruptaUninterruptible Power SupplyManual de uso | Manual de utilização | User ManualESPTENSeguridad y armoníaININTERRUMPIDASAI ONLINE6000VA© 2013. PHASAKUPS ONLINEONLINE UPS10000PH 9360 | PH 9301 …
  • Integra

    EPRO-Rack1K-3K

    (21 pages)
    ____________________________________________________________________________________________ (091214_Sp) Integra EPRO 1K-3K - 1 USER MANUAL ONLINE DOUBLE CONVERSION UPS User Manual: 220V (Europe: «Schuko» Zone) 110V (America: «NEMA» Zone) …
  • Toshiba

    G9000 SERIES

    (17 pages)
    CORPORATE OFFICE 13131 WEST LITTLE YORK ROAD HOUSTON, TX 77041 PHONE: (713) 466-0277 (800) 231-1412 FACSIMILE: (713) 896-5226 1 TOSHIBA G9000 80/100/160/225 kVA GUIDE SPECIFICATION THREE PHASE UNINTERRUPTIBLE POWER SUPPLY …
  • Tripp Lite

    SMART2200RM2UN

    (6 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SMART2200RM2UNSmartPro 2.2kVA 1.92kW Line Interactive Sine Wave UPS, Pre-installed SNMPWEBCARD, 2U, LCD, USB,Serial, EPO, 120V Highlights2.2kVA / 2200VA / 1920W line interactive 2U rack/tower UPS; 0.87 powerfactor120V nominal output during b …

Comments, Questions and Opinions: