MORLEY ZX1Se Operation & User’s Manual

MORLEY ZX1Se Manual Online:

4.2, 1804 votes
MORLEY ZX1Se User Manual
MORLEY ZX1Se User Guide
MORLEY ZX1Se Online Manual

Text of MORLEY ZX1Se User Guide:

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS Table of Contents 1 INTRODUCTION..........................................................................................................................1 1.1 NOTICE ...................................................................................................................................1 1.2 WARNINGS AND CAUTIONS.......................................................................................................1 1.3 NATIONAL APP

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page ii Document No.996-182-000-1, Revision: 01 User Manual 7 LEVEL 3 PROGRAMMER FUNCTIONS.................................................................................. 21 8 LOG BOOK............................................................................................................................... 22 Table of Figures FIGURE 1 - ZX1SE & ZX2SE CONTROLS AND DISPLAYS.......................................................................... 3 FIGURE 2 - ZX5SE & ZX10SE CONTROLS AND D

  • ZX Fire Alarm Control Panel MORLEY-IAS 1 Introduction 1.1 Notice • The material and instructions covered in this manual have been carefully checked for accuracy and are presumed to be correct. However, the manufacturer assumes no responsibility for inaccuracies and reserves the right to modify and revise this document without notice. • These instructions cover the use and opera

  • MORLEY-IAS ZX Fire Alarm Control Panel Page 2 Document No.996-182-000-1, Revision: 01 User Manual EN54 ! EN54-2 13.7 Maximum of 512 sensors / manual call points per ZX1/2/5Se panel; max of 1024 for the ZX10Se. • The ZX1Se, ZX2Se, ZX5Se and ZX10Se range of panels has many features, which if used inappropriately, may contravene the requirements of EN54.

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS 3 Controls and Displays 3.1 Control keys • The control panel has two groups of control keys. • A bank of five keys contains the four system control keys: Sound Alarms, Silence / Resound, Mute, Accept and System Reset. • A bank of 17 keys contains interactive and alphanumeric keys. A 0 3 6 9> N Q T W P S V Y Z O R U X D H K G J B 1 4 7 E C 2 5 8 F I L M < 1 2 3 4 5 6 7 8 9 1011121314151617 181920 A 0 3 6 9> N Q T W P S V Y Z O R U X D H K G J B 1 4 7 E C 2 5 8 F I L

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 4 Document No.996-182-000-1, Revision: 01 User Manual Key Legend Symbol Function 0 to 9 Press to enter numbers 0-9 or letters A-J (N-W with Shift) > Press to scroll through fire alarms or faults manually on the display or letter K (X with Shift) < Press to scroll back through fire alarms or faults manually on the display or letter L (Y with Shift) Change ZM Press to change a display option (where allowed) or letter M (Z with Shift) Enter Press to confirm entry of a multiple digit number No Press to answer No, or terminate a display option

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS Indicator Colour Function What to do FIRE Red The panel has detected a fire alarm condition, or the ‘Sound Alarms’ key has been pressed. Once a false alarm has been confirmed correct the condition causing the alarm and then perform a panel reset. Fault Yellow The panel has detected a fault. This condition latches even if intermittent. Correct the condition causing the fault and then perform a panel reset. Call service engineer. Acknowledged Yellow A fault or alarm has been accepted and the internal buzzer silenced. Correct the condition causing alarm or fault and then perform a manual res

  • MORLEY-IAS ZX Fire Alarm Control Panel Page 6 Document No.996-182-000-1, Revision: 01 User Manual 3.3 Alphanumeric Display Indications • The alphanumeric liquid crystal display gives 160 characters of information on a 4-line display. The display is illuminated to assist viewing under dim ambient light conditions. • When the numeric keypad is not in use, the display

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS 4 Level 1 Display / Control Functions • At Level 1, the panel operates in a display only mode with the control keys disabled. • If fire alarm or fault conditions exist, the LED Indicators will show these. Detailed information will be scrolled on the alphanumeric display. Note that the first 4 events will, in turn, be automatically scrolled on the display – other events can be reached using the manual scroll keys ‘<’ & ‘>’. • The information on the alphanumeric display can be scrolled

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 8 Document No.996-182-000-1, Revision: 01 User Manual 5 Level 2 Control Functions • All of the functions and operational features described for Level 1 user are available and are the same for a Level 2 user. • To enable Level 2 operation, press the SHIFT key. The display will then show: 03-Mar-2007 11.38 All devices are within working limits [Panel ACTIVE Control Keys INHIBITED] [1] Do you want to enable the control keys ? • Press the Y

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS 5.1.2 Battery Low / Charger Failure • If the battery becomes disconnected the panel shows a ‘Battery Missing’ message. If the battery voltage is less than 21V DC or if there is a failure in the circuitry that charges the battery, then the panel shows a ‘Battery Low / Charger Fail’ message. Note: Be aware, however, that the ‘battery fail’ message indication when displayed as a result of a confirmed battery charger failure should not be assumed to be correct. • To silence the panel buzzer, press the MUTE

  • MORLEY-IAS ZX Fire Alarm Control Panel Page 10 Document No.996-182-000-1, Revision: 01 User Manual 5.4 User Option Functions 03-Mar-2007 11.38 All devices are within working limits [ACTIVE] 1)Commission 2)Test 3)Time [1] 4)Enable 5)Disable 6)Print 7)View • The optional functions available to the user at Level 2 are as follows: Function Descrip

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS 5.4.1.1 LED Test • To select the option, press ‘1’. • To terminate the test, press No. • The panel will flash all of the indicators on the LED Display and will step through all of the Zone FIRE and FAULT indicators and then return to the menu after a period of approximately 45 secs. 5.4.1.2 LCD Test • To select the option, press ‘2’. • To terminate the test, press No. • The alphanumeric display will flash all displayable characters in all positions of the display and then return to the menu. 5.4.1.3 Zones Test 5

  • MORLEY-IAS ZX Fire Alarm Control Panel Page 12 Document No.996-182-000-1, Revision: 01 User Manual • The Walk Test is then entered and the display will show a scrolling ‘W’ alternating with a ‘Press No to Exit’ on the bottom line: Walk Test 12 - 15 Test from zone 12 to zone 15 -----W-------------------------------------- When panel

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS Walk Test 12 - 15 [ACTIVE] 1)Commission 2)Test 3)Time [1] 4)Enable 5)Disable 6)Print 7)View • To cancel the walk test, re-select the Test / Zones option. The display will then return to the normal walk test view, showing the current walk test in operation. For example: Walk Test 12 - 15 Test from zone 12 to zone 15 -----W--------------------------------------- • Then press the ‘NO’ key to cancel the test. 5.4.1.4 Output Test Access to this test option is only available using the Level 3 password. • To select the option, press ‘4’ and then enter the Level 3 password ‘####’.

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 14 Document No.996-182-000-1, Revision: 01 User Manual 03-Mar-2007 11.38 All devices are within working limits RELAY OPERATED 2 The onboard sounder circuits are constantly monitored for correct end-of-line termination. A sounder error will be reported if one of the sounders is left in the operated test state for more than 5 seconds. 5.4.1.5 Audible Indicator Test • To select the option, press ‘5’. • The buzzer will beep once. 5.4.2 Time • To change the date and time shown

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS 5.4.3.1 Enable or Disable Zones • To enable or disable input devices by zone, select option 1. Any loop driven output devices such as sounders or relay modules will still activate as programmed even if disabled. Only the input signal from these devices will be ignored. • Press ‘1’ and the display will prompt for the required zone number. 03-Mar-2007 11.38 All devices are within working limits Disable Zone ? ( Enter number or use ">" to scroll ) �

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 16 Document No.996-182-000-1, Revision: 01 User Manual 03-Mar-2007 11.38 All devices are within working limits Loop 2 Address _ _ _ • Enter the address of the device required. If the address is less than 3-digits long (for example address 34), this can be entered as either 034 or 34 followed by ENTER. • The display will then ask for confirmation (OK?). 03-Mar-2007 11.38 All devices are within working limits Loop 2 Address 034 OK ? • Press the Yes key to confirm. • When an individual point is disabled, the DISABLEMENT LED will be illuminated. • The corresponding Zone

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS • The user may enable or disable the operation of the Delayed Day Mode through the Enable or Disable Menu. • To select Delayed Day Mode, press ‘4’ from the Enable or Disable Menus. The display now presents two options: Disable: 1 of 1 [n] Output Delays Disabled 1)Disable the day mode delay period 2)Temporary override - Turn off delays Enable: 1 of 1 [n] Output Delays Disabled 1)Configure the day mode delay period 2)Temporary override - Turn on delays 5.4.3.4.1 Configure Day Mode Delay Period / Disable Operation • To select configure or disable options, press ‘1’. • When enabling t

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 18 Document No.996-182-000-1, Revision: 01 User Manual 03-Mar-2007 11.38 All devices are within working limits 1)Sounders 2)Relays ENABLED ENABLED • The DISABLEMENT and either the SOUNDERS DISABLED or RELAYS DISABLED LED indicators will be illuminated when the outputs are disabled. A warning message will also be shown on the alphanumeric display. • The sounders can only be disabled after confirmation by re-entering the Level 2 password. 5.4.3.6 Enable or Disable Delays • If the panel has been configured to operate with (pattern) phased evacuation or delays to specific outputs it is pos

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS • This menu controls the operation of the optional front panel printer on the ZX5Se and ZX10Se panels only. The user options are as follows: 1. Devices: Prints out the present status and text assigned to all devices on a loop. 2. Events: Prints out the contents of the event log. 3. Mode: Sets the printing mode. The current mode of operation is shown on the display. The possible modes are: Manual - Prints on demand only Auto - Automatically prints faults and fire alarms as

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 20 Document No.996-182-000-1, Revision: 01 User Manual 6 Delayed Day Mode Operation • The panel can be configured to operate in a delayed day mode during the daytime for any specified zone. • During this time, high sensor signals received from a detector will generate a fire alarm message on the panel but delay the ringing of the sounders. The panel will initiate a full fire alarm condition if no action is taken on this warning within a specified period. • The use of delayed day mode mu

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS 7 Level 3 Programmer Functions • Level 3 functions are for service engineer or installation company use only and, therefore, are not covered by this manual. User Manual Document No. 996-182-000-1, Revision 01 Page 21

  • MORLEY ZX1Se, MORLEY-IAS ZX Fire Alarm Control Panel Page 22 Document No.996-182-000-1, Revision: 01 User Manual 8 Log Book • In accordance with best practice, the user should maintain a logbook to record all events resulting from or affecting the system. The logbook should be kept in a place accessible to authorized persons (preferably near the main panel. • One or more identifiable individuals should be appointed to oversee or carry out all entries in the logbook. The names of the persons (and any changes

  • MORLEY ZX1Se, ZX Fire Alarm Control Panel MORLEY-IAS EVENT DATA Date Time Counter Reading Event Action Required Date Completed Initials Table 7 - Logbook Event Data User Manual Document No. 996-182-000-1, Revision 01 Page 23

  • MORLEY ZX1Se, © MORLEY-IAS. All rights reserved. ® The MORLEY-IAS Logo is a registered trademark. MORLEY-IAS Fire Systems, Charles Avenue, Burgess Hill. West Sussex. RH15 9UF. England . Web site: www.morleyias.co.uk

Related Products and Documents (Fire Alarms):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Metra Electronics 99-5819 Installation instructions manual metra-electronics/99-5819-PIF.pdf 26 Dec 2022 8
2 EZYmount SLT-800 Installation instructions manual ezymount/slt-800-9QE.pdf 19 Jan 2023 8
3 ZyXEL Communications WAP7205 Quick start manuals zyxel-communications/wap7205-997.pdf 20 Dec 2022 2
4 Sony CPJ-200 - Color Lcd Projector Operating instructions manual sony/cpj-200-color-lcd-projector-LTD.pdf 08 Feb 2023 15 0.83 Mb
5 Samsung DA99-00275B Owner's manual and installation samsung/da99-00275b-F5A.pdf 27 Nov 2023 36 2.82 Mb
6 HP 8100C Operation & user’s manual hp/8100c-49Y.pdf 15 Sep 2022 80 2.69 Mb

Similar Resources:

  • Notifier

    FS-WST

    (2 pages)
    1 I56-5921-000 INSTALLATION AND MAINTENANCE INSTRUCTIONS Model FS-WST Addressable Wall Mount Strobe Notifier by Honeywell9 Columbia Way Baulkham Hills,NSW 2153 Australiawww.notifier.com.auSPECIFICATION Item Parameter Description Note Operating Voltage DC24V( DC15V~ DC32V) …
  • Global Fire

    ORION 4

    (23 pages)
    Manufacturers of Fire Detection Equipmentwww.globalfire.ptINSTALLATION, OPERATION AND MAINTENANCE MANUAL - 10/2011ORION - 2, 4, 8 ZONE FIRE ALARM CONTROL PANELINSTALLATION, OPERATION AND MAINTENANCE MANUALVersion - 10/2011ORION2, 4, 8 Zone Fire Alarm Control Panel …
  • Simplex

    4010ES

    (26 pages)
    Cautions, Warnings, and Regulatory InformationREAD AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual. These instructions must be followed to avoid damage tothis product and associated equipment. Product operation and reliability depend upon proper installation.DO NOT INSTALL ANY SIMPLEX™ PRODUCT THAT APPEARS DAMAGED Upon unpac …
  • FireClass

    FC421CP-I

    (2 pages)
    120.515.224_FC-D-421CPI-F, doc. version 4.0, 9. November 2018© 2018 Johnson Controls. All rights reserved. All specifications and other information shown were current as of document revision date and are subject to change without notice.www.fireclass.netTyco Fire & Security GmbH, Victor von Bruns-Strasse 21, 8212 Neuhausen am Rheinfall, SwitzerlandFC42 …
  • Honeywell

    NOTIFIER NFS-320C

    (6 pages)
    DN-60085:J • 12/20/2013 — Page 1 of 6NFS-320CIntelligent AddressableFire Alarm SystemIntelligent Fire Alarm Control PanelsCanadian DN-60085:J • A-15GeneralThe NFS-320C intelligent Fire Alarm Control Panel is part ofthe ONYX® Series of Fire Alarm Controls from NOTIFIER.In stand-alone or network configurations, ONYX Series prod-ucts meet virtually every …
  • Ziton

    ASWP-RF

    (2 pages)
    Ziton Weatherproong Kit Installation GuideGeneralThe Ziton Weatherproong Kit for Wireless Notication Products is available under the following part number:PART NO VARIANT TYPEASWP-RF Ziton Weatherproong Kit for Wireless Notication Products Supplied PartsEnsure that you have all of the parts listed in Figure 1. SpecicationIP rati …

Comments, Questions and Opinions: