  • GB - 10 - 4.4 Installing the diffuser After securing the air conditioner to the roof of the vehicle, connect the power supply cable to the con- nection terminal board [Fig. 10 ref. 3], located on the diffuser, complying with the positions shown on the adhesive label: blue wire: neutral brown wire: positive yellow-green wire: earthing ( ) Fit the multi-pole cable conn

  • Telair Iceberg 3500, - 7 - GB In order to install the air conditioner, you must first make sure the roof of the vehicle is able to hold its weight. If not, reinforce it. Choose a central, level and flat area on the roof. Make sure that no obstacle inside the vehicle can hinder fastening of the diffuser [Fig.1 ref. 4] and the exit of the cooled air from the adjustable outlets [Fig. 1 ref. 5]. To install the air conditioners, you can choose ei- ther of two solutions: Remuve existing rooflight and use aperture Cut new aperture. 4.2.1 Using rooflight aperture You can do so on condition that the aperture of the rooflight measure of 400 x 400 mm. For the dimensions of the air conditioners and o

  • Telair Iceberg 3500, GB - 8 - 1 5 4 1 4.2.3 Power supply cable To set up the power supply for the air conditioner, lay a three-pole (positive-neutral-earth), power sup- ply cable with a cross section of at least 2.5 mm 2 . This cable must be connected at one end to the differential cut-off switch previously placed inside the distribution board of the vehicle, while the other end must reach the opening on the roof. Let the cable come out from the reinforcing frame by about 50 cm to allow easier connection to the air condi- tioner [Fig. 6]. 6 Before performing any kind of connection, always make sure that there is no power inside the distribution board or at the cable end. The air

  • Telair Iceberg 3500, GB - 6 - 3 SHIPPING, HANDLING, STORAGE 3.1 Storage The air conditioner is protected during shipping by suitable packaging. The air conditioner must be stored horizontally, in a covered, dry and ventilated area. The packaging is designed so as to allow stacking of a maximum of 5 (five) air conditioners. Do not turn the unit upside down. The right position is the one shown by the symbol printed on the package ( ) . Stacking more than 5 air con- ditioners will not only compromise the integ- rity of the equipment, but will also be a risk to personel. 3.2 Weight Weight

  • - 11 - GB 5. USER INSTRUCTIONS 5.1 Foreword The Manufacturer shall not be held liable for any damage due to the air condi- tioner not working. The air conditioner consists of a compressor run- ning at 230 VAC 50 Hz. The compressor com- presses the coolant gas inside a coil pipe which, when ventilated, gives off the heat developed dur- ing compression. The coolant gas is then conveyed int

  • Telair Iceberg 3500, GB - 2 - Via E. Majorana , 49 48022 Lugo (RA) ITALY “CE” COMPLIANCE STATEMENT Under Machine Directive 89/392/EEC, attachment II A We hereby represent that the air conditioner, the data concerning which appear below, has been designed and built to correspond to the essential safety and health requirements laid down by the European Directive on Machine Safety. This statement shall not be valid any longer if any changes are made on the machine without our written approval. Machine: AIR CONDITIONER Model: ICEBERG ………………… Serial number: ……�

  • Telair Iceberg 3500, GB - 12 - The minimum cooling value is marked by the small- est dot, the maximum cooling value is marked by the largest [Fig. 15 ref. 2]. The thermostat controls the temperature automati- cally, but the speed of the fan must be set manu- ally by the user. Set the fan speed required on the relevant selector switch [Fig. 15 ref. 1]. To use the air conditioner in the most effective manner, we suggest the following settings: Minimum speed - Minimum cool (night-time) Medium speed - Maximum cool Maximum speed - Medium cool To use the conditioner more efficiently, we suggest you perform the following operations: First choose Maximum Cool and the second v

  • - 23 - GB GENERAL TERMS OF WARRANTY Telair guarantees that its products are without faults or defects in their material and/or construction. The effects of the warranty are understood to be limited to the right to obtain replacement or repair free of cost of any part which should turn out to be defective, within 12 months from the date of purchase of the product and in Telair’s opinion.

  • Telair Iceberg 3500, - 17 - GB 5) PROBLEM The fan of the evaporator does not work CHECK Make sure that there is 12 VDC between the green ventilation speed selector switch wire [Fig. 16 ref. 8] and the black relay selector wire [Fig. 16 ref. 2]. OPERATION Replace the fan speed selector switch. CHECK Make sure that there is 12 VDC between the black and the green wire of the evaporator ventilator [Fig. 16 ref. 9]. OPERATION Check the harness and the multi-wire connector. 6) PROBLEM The heating resistance does not work CHECK Make sure that there is 12 VDC on t

  • Telair Iceberg 3500, - 13 - GB 5.8 Turning off To turn the air conditioner off, position the switch [Fig. 15 ref. 4] on the position. After having turned the air con- ditioner off, either using the thermostat knob or the ON-OFF switch, wait at least three min- utes before turning it back on again, so the cool- ant can stabilise its pressure. Lack of compli- ance with this rule may damage the compres- sor irreparably. 5.9 Safety rules Always use earthed power sources protected by differential switches. Never use the air conditioner near flammable liq- uids. Never use the air conditioner for any purpose other than that designed for by the Manufacturer. Never modify

  • Telair Iceberg 3500, - 9 - GB 4.3 Positioning the air conditioner Before positioning the air conditioner on the roof of the vehicle, spread a sufficient of quantity slow- drying sealant around the edges of the opening. Take the air conditioner on to the roof of the vehi- cle [Fig. 7 ref. 2] and position it over the opening (previously treated with sealant). Remember that the side with the ventilation grid must face the rear end of the vehicle. The arrow on Figure 7 shows the driving direction of the vehicle. The support gasket must be placed flush with the edge of

  • Telair Iceberg 3500, GB - 16 - 2) PROBLEM The compressor does not work CHECK Make sure that there is 12 VDC between the black wire of the relay [Fig. 16 ref. 2] and the red wire of the fan speed selector [Fig. 16 ref. 8]. OPERATION Check the harness and the multi-wire connector [Fig. 16 ref. 7]. CHECK Make sure that there is 12 VDC on the fan speed selector [Fig. 16 ref. 8] between the orange and the black wire of the relay. OPERATION Replace fan speed selector. CHECK Make sure there is 230 VAC between the white wire of the relay [Fig. 16 ref. 2] and the blue wire of the feeder input terminal [Fig. 16 ref. 4]. OPERATION Replace the relay. CHECK Make sure that when the h

  • Telair Iceberg 3500, - 3 - GB CONTENTS 1 FOREWORD ....................................................................................................................pag. 4 1.1 Purpose and scope of this manual ............................................................................ pag. 4 1.2 Symbols and Definitions ............................................................................................ pag. 4 1.3 General Information ...........................................................................................pag. 4 2 AIR CONDITIONER IDENTIFICATION DATA .................................................................pag. 5 2.1 Components ....................

  • Telair Iceberg 3500, Foto e disegni non contrattuali - Les photos et les dessins ne sont donnés qu’à titre indicatif. We reserve the right to make technical changes without prior notice - Fotos und Zeichnungen nicht vertraglich. Fotos y planos no indicados en contrato AIR CONDITIONER IN EUROPE: GREAT BRITAIN - SCAN TERIEUR LTD 30, The Metro Centre, Tolpits Lane - Watford, Herts - England - WD18 9XG Tel. 01923 800353 - Fax 01923 220358 HOLLAND - KARMAN AGENTUREN Emmastraat, 31 1213 AJ Hilversum - Holland Tel. 035 6240156 - Fax 035 6242141 FRANCE - GERARD DURAND Lieu dit Borde Rouge 31590

  • Telair Iceberg 3500, - 15 - GB 8. TROUBLESHOOTING (for technical staff only) Before performing the checks listed below, make sure that the ON/OFF switch is in the ON position [Fig. 15 ref. 4], the thermostat is in the all-cold position [Fig. 15 ref. 2], and the fan speed selector switch is in position 1 [Fig. 15 ref. 1]. 1) PROBLEM The air conditioner does not start up CHECK Make sure that the infeed terminal of the air conditioner between the blue and the yellow wire is powered at 230 VAC [Fig. 16 ref. 4]. OPERATION Check the differential switch, the fuse protection on the power supply line, the wholeness of the power supply line

  • Telair Iceberg 3500, - 5 - GB 2. AIR CONDITIONER IDENTIFICATION DATA 2.1 Components (fig. 1) 1 Ventilation grid 2 Top hood 3 Identification label 4 Diffuser 5 Adjustable air outlets 6 Ambient air suction grid 7 Fan speed selector switch 8 Hot-cold air selector switch 9 Thermostat control 10 ON/OFF switch 2.2 Identification label 1 Model 2 Machine code 3 Serial number 4 Compressor and fans consumption 5 Heater power 6 Coolant gas type and quantity 2.3 Technical features 3.500 3.500R Cooling power 3500 BTU 3500 BTU Fan speed number 3 3 Power supply 230 V 50 Hz

  • GB - 14 - 6. MAINTENANCE Accurate inside cleaning of the air conditioner is important to keep it efficient. Before accessing the air con- ditioner, you must disconnect the 230V power supply and wait for all parts to cool off. Take off the outside cover and spray the proper detergent on the heat exchangers (evaporator and condenser), and then rinse to remove all deb

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP 2200 - LaserJet B/W Laser Printer Service manual hp/2200-laserjet-b-w-laser-printer-RRX.pdf 29 Nov 2023 324 7.27 Mb
2 Targus Bluetooth Numeric Keypad Operation & user’s manual targus/bluetooth-numeric-keypad-7I8.pdf 22 Sep 2023 30 3.14 Mb
3 JUKI AMS-210D Instruction manual juki/ams-210d-4R8.pdf 10 Dec 2023 108
4 Sony XBA-NC85D Operating instructions sony/xba-nc85d-PLQ.pdf 20 Jan 2023 2 1.27 Mb
5 SMC Networks EZ Switch SMC-EZ1016DT Features smc-networks/ez-switch-smc-ez1016dt-JJ3.pdf 01 Dec 2023 2 2.07 Mb
6 GE DSKS433EB Dimensions and installation information ge/dsks433eb-F7O.pdf 17 Jan 2023 4 0.27 Mb

Similar Resources:

  • Electrolux

    EXP09CKEWI

    (160 pages)
    EN AIR CONDITIONERFR CLIMATISEURIT CONDIZIONATORENL AIR CONDITIONERDE KLIMAGERÄTPL KLIMATYZACJACZ KLIMATIZAČNÍ ZAŘÍZENÍEXP09CKEWIEXP11CKEWIUSER MANUAL MODE D'EMPLOI MANUALE DELL’UTENTEGEBRUIKSAANWIJZINGBEDIENUNGSANLEITUNGINSTRUKCJA OBSŁUGI UŽIVATELSKÁ PŘÍRUČKA 224466890112134 …
  • Samsung

    DVD-P721M

    (26 pages)
    USUSDDVD PLAVD PLAYERYERDVD-P721MSERVICE DIVISION400 Valley Road, Suite 201Mt. Arlington, NJ 07856FOR YOUR NEAREST SAMSUNGSERVICE CENTERDIAL 1-800-SAMSUNGAK68-00015WDownloaded From DvDPlayer-Manual.com Samsung Manuals …
  • Price

    DFE Series

    (6 pages)
    Revision: v001 – Issue Date: 06/03/19© 2019 Price Industries Limited. All rights reserved.MANUAL – INSTALLATION + SERVICEExposed Displacement DiffuserDFE Series …
  • Samsung

    SC07ZK8

    (24 pages)
    E§§HNIKAENGLISHOWNER’S INSTRUCTIONSMANUAL DE INSTRUCCIONESMANUEL D’UTILISATIONISTRUZIONI PER L’USOMANUAL DE INSTRUÇÕESGEBRAUCHSANWEISUNG√¢∏°π∂™ Ã∏™∆∏Split-type Room Air Conditioner (Cool)Aire acondicionado doméstico sistema Split (Refrigeración)Climatiseur de type Séparé (Refroidissement)Condizionatore d’aria per ambient …
  • Livington

    CHILLTOWER

    (24 pages)
    Gebrauchsanleitung ......................... 05Instructions for Use .......................... 07Mode d’emploi .................................. 09Manuale di utilizzazione ................... 11Gebruiksaanwijzing ......................... 13Használati utasítás ........................... 15Návod k použití ................................. 17Návod n …
  • Toshiba

    RAS-10N3KV Series

    (5 pages)
    1113950109OWNER’S MANUALAIR CONDITIONER (SPLIT TYPE)For general public useIndoor unitRAS-10N3KV SeriesOutdoor unitRAS-10N3AV SeriesENGLISHFRANÇAISPORTUGUÊSPУCСКИЙTÜRKÇEESPAÑOL1113950109_EN.indd 11113950109_EN.indd 1 8/8/12 11:08 AM8/8/12 11:08 AM …

Air Conditioner Instructions:

Comments, Questions and Opinions: