Manualios.com

Argo AGW52RH U.I. Owner's Manual

Argo AGW52RH U.I. Manual Online:

4.4, 1635 votes
Argo AGW52RH U.I. User Manual
Argo AGW52RH U.I. User Guide
Argo AGW52RH U.I. Online Manual

Text of Argo AGW52RH U.I. User Guide:

  • Argo AGW52RH U.I., OPERATION OF AIR CONDITIONER 1.If power sets off, time must be set again, otherwise, timer operation is not right. 2.If the air conditioner has been in time on or time off, but you want change the time, you must cancel the primary condition then can set new time condition, otherwise, error will occur. 3.After having chosen the time mode, if you press the once incautiously, the setting time will count time anew automatically as primary setting time, and the display time will not change. So if you want air conditioner operate as primary setting time, you must set time anew . NOTICE Timer operation Press button ¡± ¡± Contr

  • Argo AGW52RH U.I., Discharge the air procedure 13 3 Connect assembly pipe to the appropriate valve on the indoor unit and outdoor unit and tighten the flare nut(as fig.1). 1.The number of bent position of the pipe in the indoor unit should not exceed 10. 2.The number of bent position of the pipe in the indoor unit and the outdoor unit should not exceed 15. 3. The radius of bent position should more than 10cm. NOTICE Connect charging hose(low pressure) of manifold gauge to the service port of gas shut-off valve. Screw down the nut of connecting pipr with wrench(the torque as follow diagram ) (Fig.1) gas sh

  • Argo AGW52RH U.I., Air inlet Connecting pipe Drain hose Drain opening Air outlet OUTDOOR UNIT NAME OF PARTS Filter Front panel Display Remote controller Air inlet Manual operation (open the Front panel) INDOOR UNIT Time indicator Sleep indicator Run indicator Power supply cord Deflector Left / Right deflector SWINGSWING MANUALMANUAL OFFOFF ONON CANCELCANCEL SETSET SLEEPSLEEP FAN SPEEDFAN SPEED OPERATIONOPERATION MODEMODE I/OI/O TIMETIME Emergency operation switch Check switch

  • Argo AGW52RH U.I., WARNING Clean the air conditioner with a soft and dry cloth. Do not use chemical solvent,insecticide, Inflammable-spraying material or which da- mage the appearance of air conditioner for c- leaning. Do not put burning appliances at the place where can be blown directly by the air, insufficient burning may occur. Do not install the air conditioner in where leak flammable gas. If there is electrical leakage accidentally from air conditioner, it is easy to cause fire or explosio

  • Argo AGW52RH U.I., CONTENTS .................................................................22 ......................................................................4 ........................6 .................................. 7 .....................1212 ...........................................1414 ....................................................1616 ......................................................1717 PP ................................................................... 11 Contents Name or Parts Safety Awareness Operation procedure Remote Controller&ap

  • Argo AGW52RH U.I., REMOTE CONTROLLER PREPARATION REMOTE CONTROLLER PREPARATION 6 Open back cover, put in batteries. Short RESET piece with forceps. (Short two RESET piece after changing the batteries.) • If the remote controller can't be operated normally, short two RESET piece, it will operate normally. • Remove batteries if Remote controller has not been used for a long time. • When the button is pressed, indoor unit will beep once or twice, indicating the receiving of the signal. If no beep is heard, press again. • Handle remote controller carefully. Do not drop, throw and get wetted. Avoid malfunction. • The signal can be reached within six metres directly in

  • Argo AGW52RH U.I., NAME OF PARTS NAME OF PARTS 5 OPERATION DISPLAY TEMPERATURE ADJUSTMNT BUTTON RUN/STOP BUTTON FAN SPEED BUTTON SLEEP BUTTON RESET PIECE TIME SET BUTTON TIME CANCEL BUTTON TIME ON BUTTON TIME OFF BUTTON OPERATION MODE BUTTON MANUAL SWING BUTTON SWING BUTTON NOTICE REMOTE CONTROLLER Signal ejecting window cool only type hasn't HEAT mode

  • Burr Oblique INSTALLATION Seal of wall hole and fasten of pipe Use putty to seal the wall hole. Use clamp ( pipe fa- stener ) to secure the pipe at specified position. indoor unit clamp screw get rid of unwanted part airproof with putty clip the connecting pipe with clamp OUTDOOR UNIT WARNING Special cable must be used to connect indoor unit and ou

  • Argo AGW52RH U.I., 1 ADVICE HEAT mode: Healthy warmness lies in the difference with outside temperature! The setting temperature for heating shall not be too different from outside temperature. Though it varies with area, set temperature to between 20 - 24 , Heating effect becomes inferior when ambient temperature is below 5 . C C C OPERATION OF AIR CONDITIONER Cool only type has not HEAT mode . 116 6 1 2 3 4 5 Operation mode adjustment AUTO mode When started, operation mode wil

  • Argo AGW52RH U.I., OPERATION OF AIR CONDITIONER (1) (2) (3) (4) (5) Change right/left air flow direction Manually swing ,to change right/left air flow direction.Complete ad- justment before operation, if adjusted during operation,the auto swinging deflector may pinch your fingers.(Fig. 1) Left/Right deflector ADVICE In DRY or COOL mode, advise to make the Fan speed with (auto), air blows downward in (1). In HEAT mode, advise to make the Fan speed with (auto), air blows downw- ard in (4). Control with remote controller to adjust up/d- own air flow direction, avoid turning deflector with hand to avoid injury. ( Fig.2 ) COOL mode DRY mode HEAT mode

  • Argo AGW52RH U.I., 1 1 2 2 5 5 3 3 4 4 INDOOR UNIT Open the front panel; Remove the screw from electrical box cover, pull the electrical box cover away from the unit and set aside. Remove the screw from fastener, pull the fastener away from the unit and set aside. Connect the cable. Replace the fastener and electrical box cover. Indoor unit terminal Screw Connecting cable Diagram 11 1 2 2 INSTALLATION Secure the mounting plate The mounting plate should be attached to the structural part of wall (post etc.). fasten string at the central hole 1 7 5 m m or m or e fr o m s id e wa ll 245 mm or m o re at least 60mm from sid e wall mounting plate plumb NOTICE The holes at s

  • PERFORMANCE PARAMETERS 230V , 50Hz ~ 3 1 4 2 5 6 7 The indicated noise value is from laboratories test before leaving factory. The rated cooling capacity and rated heating capacity value is tested under below conditions All above should be changed without notice.There are latest and accurate specifications on the name plate of your air conditioner. NOTICE

  • Argo AGW52RH U.I., 11 1 4 4 1 2 2 OPERATION OF AIR CONDITIONER Operation procedure-Control under the Remote controller Run/Stop Press I/O button, start operation, and stop when repressed. Temperature adjustment Press TEMPERATURE ADJUSTMENT button, decreases 1 by press button once, and increase 1 C C by press button once. Temperature change will display in the remote controller's display. Sleep selection Press SLEEP button, set sleep operation, and cancel when repressed. 3 3 Fan speed adjustment Press FAN SPEED button,chang

  • Argo AGW52RH U.I., If problems can not be corrected after doing below items, please stop the air conditioner, contact our air conditioner specially eng- aged service centre nearest to you to get help. Is there a fault ? Fault analysis Air conditioner does not operate at all. Does power fail ? Is plug out ? Does power fuse or switch off ? Is voltage higher than 253 V or lower than 207V? Is time set suitable? Remote controller is not available and does not display. It is not running after I/O button is pressed. Cooling and heating efficiency is not good. Air will not immediately

  • Argo AGW52RH U.I., Indoor unit fan stops for about 10 minutes during heating. It is defrosting of the outdoor unit coil.It should complete this process in about 10 minutes at most.( It freezes when outdoor temperature is low and humidity is high. ) Issues cracking sounds The friction sounds caused by expansion and contraction of front panel resulting from temp- erature changes. You can hear the sound of running water It is the sound of expanding refrigerant inside the air conditioner. Sound of accumulated water dropping on the heat-exchanger. Melting sounds of frost on heat-exchanger. Indoor unit issue pooosh sound and click sound. Click so

  • Argo AGW52RH U.I., Thank you for choosing an Air Conditioner.Please read this OWNER'S MA- NUAL carefully prior to using, keep it for further reference. OWNER'S MANUAL SPLIT AIR CONDITIONER WALL MOUNTED TYPE AGW52RH U.I./AGE52RH U.E.

  • Argo AGW52RH U.I., The drain hose must be arranged beneath the copper pipe. The drain hose must not be hunched or bended. Do not wrap the drain hose by pulling it. When the drain hose must be through the house, it should be wrapped by the special heat insulated materials. The copper pipe and the drain hose must be wrapped by felt strip. Heat insulated pad should be used in the place that the pipe contact the wall. NOTE: 1 1 2 2 3 3 INSTALLATION ROUTE OF PIPE If pipe came out of the right side of the indoor unit, cut part 1 on the unit; If pipe came out of the lower-right side

  • 1 2 Before installation, inspect the following accessories: Installation Instructions Location of indoor unit Airflow can not be blocked. Good ventilation, low dust,avoids rain or direct sunshine. Operation noise or air blowing out will not affect neighbors' comfort. Firmly mounted on rack,which will red- uce noise and vibration. Avoid places close to inflammable gas lea

  • Argo AGW52RH U.I., INSTALLATION SKETCH 1 E A 9 5 6 7 G H F C D B 2 3 4 Installation sketch abov e 50 0mm above 155mm above 24mm above 105 mm abo ve 100m m abo ve 3 50mm above 100m m above 100mm Confirm installation place with the marker of indoor unit inst- allation board. Notice:do not put the drain hose high. front right back underside left-back left back Configuring pipe can be installed to back, right, underside, or left-back side. Cover connecting pipe with heat-isolating material. the thickness of heat- isolating material is 8mm. Put the wood

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Canon dp-v3010 Instruction manual canon/dp-v3010-RGX.pdf 23 Mar 2023 102
2 Daewoo DWF-216SP Service manual daewoo/dwf-216sp-776.pdf 31 Oct 2023 38 2.68 Mb
3 Robin America EH41 Parts manual robin-america/eh41-746.pdf 24 Jan 2023 28 0.56 Mb
4 Sony NAS-SC500PK Operating instructions manual sony/nas-sc500pk-76J.pdf 16 Aug 2022 203
5 KD PL 001 – B Maintenance manual kd/pl-001-b-2FS.pdf 01 Oct 2022 14
6 Meade 2120 Instruction manual meade/2120-13T.pdf 03 Oct 2022 80

Similar Resources:

  • Haier

    H2SM- - annexe 10

    (16 pages)
    Drawing for the installation of indoor and outdoor unitsNecessary Tools for InstallationDriverƽTorque wrenchƽ(17mm,22mm,26mm)NipperƽReamerƽHacksawƽ Pipe cutterƽGas leakage detector orƽsoap-and-water solutionHole core drillƽ Flaring toolƽSpanner(17,19 and 26mm)ƽ KnifeƽMeasuring tapeƽIndoor UnitPlace, robust not causing vibration, where the body ca …
  • Idylis

    0416711

    (33 pages)
    1PORTABLE AIR CONDITIONERITEM #0416711Français p. 22Español p. 43Serial NumberPurchase DateIdylis® is a registered trademark of LF, LLC. All Rights Reserved.Questions, problems, missing parts? Before returning to your retailer, call our customer service department at 1-800-643-0067, Monday - Thursday, 8 a.m. - 6 p.m., EST, Friday, 8 a.m. - 5 p.m., EST.ATT …
  • Payne

    PY3G

    (10 pages)
    1PY3GOwner’s Manual13 SEERSINGLE PACKAGED AIR CONDITIONER ANDGAS FURNACE SYSTEMWITH R---410A REFRIGERANTSIZES 024---060A06079Fig. 1 -- Unit PY3GNOTE TO EQUIPMENT OWNER:For your convenience, please record the model and serial numbers of your new equipment in the spacesprovided. This information, along with the installation data and dealer contact informatio …
  • Mitsubishi Electric

    SLZ-KA25

    (152 pages)
    ДЛЯ УСТАНОВИТЕЛЯFÖR INSTALLATÖRENPARA O INSTALADORΓΙΑ ΑΥΤΟΝ ΠΟΥ ΚΑΝΕΙ ΤΗΝ ΕΓΚΑΤΑΣΤΑΣΗPER L’INSTALLATOREPARA EL INSTALADORVOOR DE INSTALLATEURPOUR L’INSTALLATEURFÜR INSTALLATEUREFOR INSTALLERAir-ConditionersSLZ-KA25, KA35, KA50VAQ3 KA25, KA35, KA50VAL3INSTALLATION MANUALFor safe and correct use, please read …
  • Mitsubishi Electric

    PAC-MK53BC

    (30 pages)
    March 2018SPLIT-TYPE, HEAT PUMP AIR CONDITIONERSTECHNICAL & SERVICE MANUALCONTENTS1. SAFETY PRECAUTION ······································· 22. OVERVIEW OF UNIT ··········································· 53. SPECIFICATIONS ·······················� …
  • ZALMAN

    CNPS9500 AT

    (7 pages)
    * Please read before installation.http://www.zalman.co.kr http://www.zalmanusa.comIntel Socket LGA775 CPUDual Core PentiumPentium 4Celeron D(English version)CNPS9500 AT(English version) …

Comments, Questions and Opinions: