Manualios.com

Argos Challenge Instruction Manual

Argos Challenge Manual Online:

3.95, 664 votes
Argos Challenge User Manual
Argos Challenge User Guide
Argos Challenge Online Manual

Text of Argos Challenge User Guide:

  • Argos Challenge,   SAFETYinSTRucTionS Thank you for choosing this innovative Challenge air conditioner. We suggest that you keep this manual in a safe place for future reference. It describes the many benefits and advanced features this unique product has to offer. Before you use your air conditioner you should carefully read these instructions to maximise this product s performance. Challenge has specialised in complete indoor environmental control, manufacturing portable air conditioners

  • Argos Challenge, 3 Close to a heat source Inside unit exposed to the weather outdoors In a permanent very humid environment If the power cable wires are frayed or cut When small children may be left unattended If an extension lead may become overloaded Where the power cable may be damaged On a slope or uneven surface Where it may be damaged by chemicals Where there is a risk of interference by foreign objects This products is not made for DIY repair If there is a risk of liquid falling on the unit Do not use your air conditioner:

  • Argos Challenge, BEFORE USE GENERAL SAFETY • Only use in the upright position on a flat level surface and at least 36 cm from any objects (fig 1 & 4). • Do not place objects on the unit or block the air inlet / outlet (fig. 2). • Closely supervise any children and pets when unit is in use. ELECTRICAL SAFETY • For indoor use only. • Switch off and unplug when not in use. • Do not use in humid or wet environments (fig 3) • Do not pull the UNIT by the cord. •

  • Argos Challenge, PARTS Front Back FIG.5 FIG.6 1. 2. Control panel 3. Air outlet 4. Carrying handle 5. Caster 6. Cord storage 7. Air filter 8. Air inlet 9. Exhaust air outlet 10. Air inlet 11. Wate r stopper/drainage Accessories 12. Exhaust hose 13. Outward adapter - for insertion over ho se and into foam strip (or into hole in the wall/window). 14. Round cap for filling the hole in wall/wi ndow. Active carbon filter Drain tube for continuous drain age FIG.7 Remote control

  • Argos Challenge, INSTALLATION Installation of the exhaust pipe The unit is a portable air conditioner that may be moved from room to room. Using the adaptor FIG.9 • Cut a 137mm diameter hole in the wall or window. • Feed exhaust hose through the window or wall and attach the threaded adaptor from the outside as shown. • When not in use, plug the hole with the cover provided. FIG.10 Wall or Window Outward adaptor 6

  • Argos Challenge, Mounting of the exhaust pipe • Use only the hose provided and clip exhaust hose to the back of the air conditioner • Avoid kinks and bends in the exhaust hose as this will cause expelled mo ist air to build up causing the unit to overheat and shut down. Fig 11 & 12 show correct position • The hose may be extended from 300mm to 1 500mm but for maximum efficiency use the shortest length possible. FIG.11 FIG.12 FIG.13 WARNING! The length of the exhaust pipe is special

  • Argos Challenge, Installation of the carbon filter 1. Remove the filter frame from the unit. 2. Remove the active carbon filter from its plastic bag. 3. Insert the active carbon filter into the back of t he unit. 4. Re-fit the filter frame inside the unit. 1 6 FIG.15 8

  • Argos Challenge, OPERATION Control panel FIG.16 1. 2. Timer button 3. 4. Sleep button 5. 6. Low ventilation indicator 7. High ventilation indicator 8. Receiver for remote control 9. Sleep operation indicator 10. 11. 12. 13. Timer operation indicator 14. Compressor operation indicator 17. Auto mode in dicator COMP AUTO COOL FAN FULL WATER HI LOW SPEEDSLEEP TIMER MODE Mode button Fan speed Decrease temperature button ON/OFF button Fan mode indicator Increase temperature button Air-conditioning mode BUTTONS Mode button - It is for selecting Fan mode, Air-conditioning mode or auto mode. Timer button - It is to switch on / off the tim

  • Argos Challenge, INDICATORS Water Full indicator Low ventilation indicator - This light will be illuminated when the appliance is operating with low speed fan. High ventilation indicator - This light will be illuminated when the appliance is operating with high speed fan. Sleep operation indicator - This light will be illuminated when the appliance is operating under the sleeping mode. Timer operation indicator - This light will be illuminated when the timer mode is ON. Compressor operation indicator - This light will be illuminated when t

  • AUTO MODE temperature. SETTING THE TIMER finished setting, the display will revert to the room temperature. 11 Once the de sired room temperature is reached, the compressor will turn on and off automatically maintaining the room temperature that you have set. After finished setting, the display will revert to room is illuminated. The only thing you need to do is

  • Argos Challenge, REMOTE CONTROL AIR FLOW Adjust the air flow up and down by turning the outlet grill around at its horizontal axis. IMPORTANT cooling will resume. 12 batteries are required to will flash whenever a button is pressed. use the remote control. Point the remote control hand the control panel of the unit and press the switching the unit off, Ventilation will temp erature rises above the chosen value, the set towards The air conditioner responds to all signals that are sent by the remote control. Two AAA relevant button, the red LED on the hand set please wait at least 3

  • Argos Challenge, During the process of cooling, some water will be extracted from the air into the unit. If the reservoir is full, both of the compressor and mot or will stop and the units would buzz (you To make the cooling work again, please empty the water by one of the following ways: 1. Turn off the air conditioner and avoid moving it when full. 2. Position a container (a water tray for example ) underneath the drain hole. 3. Remove the drain knob & rubber plug from the drain h ole and allow the water to drain out. 4. Whe n the container is almost full, replace the rubber plug in the drain hole and empty the water tray. 5. Rep eat until the unit i

  • Argos Challenge, • The drain tube may be extended by adding an extension tube and using a suitable connector. FIG.21 Drain tube Please note The drain mu st be at or below the outlet level. Originally s upplied tube Flashi ng ‘full water’ indicator will not function in this mode of drainage. If you want to extend the water tube, you can connect it with another tube Extension tube (OD: 18 mm) FIG.22 • • • ( 18mm) -Make sure the tube has no sharp bends and slopes dowm all the way to let the water flow freely. Note: When the unit is relocated or permanent drainage is not wanted any more, simply disconnect t

  • MAINTENANCE Always unplug the air conditioner from the mains before cleaning. To maximize the efficiency of the air conditioner clean regularly. Cleaning the housing Use a soft, damp cloth to wipe the body clean. Never use aggressive chemicals, gasoline, detergents, chemically treated cloths, or other clea nsing solutions. These all could possibly hurt the cabinet.

  • Argos Challenge, Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property. Problem Solution The air conditioner does not function. No power supply. Connect to a functioning outlet and switch on. Is the power light flashing? Empty the drain pan. Timer function is active. Deactivate the TIMER function. The air conditioner does not seem to perform. The unit is in direct sunlight. Close curtains. Windows or doors open, many people or a heat source in the room. Close doors and windows, place an extra air conditioner.

  • Argos Challenge, SPECIFICATION Model no. TC-8061 Cooling capacity Power/Ampere consumption for cooling* Air volume (max. speed) 3 Humidity removal capacity Power supply Compressor rotary Refrigerant R410A Fan speed 2 Timer Working temperature o C Exhaust pipe Net Weight Dimension WASTE ELECTRICAL PRODUCTS SHOULD NOT BE DISPOSED OF WITH HOUSEHOLD WASTE. PLEASE RECYCLE WHERE FACILITIES EXIST. CHECK WITH YOUR LOCAL AUTHORITY FOR RECYCLING ADVICE. BTU/hr 9000 3 5 m /h ~ 220~2

  • Before Switching on make sure that the voltage of your electricity supply is the same as that indicated on the rating plate. MAIN CORD Wiring Instructions: Should it be necessary to change the plug please note the wires in the mains lead are coloured in accordance with the following code : BLUE - NEUTRAL BROWN - LIVE GREEN AND YELLOW - EARTH As the colours of the wires in the mains lead of

  • PRODUCT GUARANTEE This product is guaranteed against manufacturing defects for a period of This product is guaranteed for twelve months from the date of original purchase. Any defect that arises due to faulty materials or workmanship will wither be replaced, refunded or repaired free of charge where possible during this period by the dealer from whom you purchased th

More Instructions:

DOWNLOAD

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 BenQ MS512H Operation & user’s manual benq/ms512h-H51.pdf 03 Mar 2023 58
2 Blodgett BG3240 Installation, operation and maintenance manual blodgett/bg3240-BH6.pdf 12 Sep 2022 80 4.11 Mb
3 Electrolux EW24ID70QT Installation instructions electrolux/ew24id70qt-469.pdf 07 Dec 2023 2
4 Technics SL-B210 - SERVICE Service manual technics/sl-b210-service-3D4.pdf 02 Feb 2024 15 1.81 Mb
5 Samsung DIGIMAX 350SE Operation & user’s manual harman-kardon/digimax-350se-T99.pdf 07 Nov 2022 118
6 SPX Cooling Technologies MARLEY AV 98-1514E Operation & user’s manual spx-cooling-technologies/marley-av-98-1514e-H23.pdf 16 Aug 2023 32 0.53 Mb

Similar Resources:

  • Sanyo

    SPW-CR1503GDYH8

    (377 pages)
    FILE NO.TECHNICAL DATA&SERVICE MANUAL85464869177001 REFERENCE NO. TD831077OUTDOOR MODEL No. PRODUCT CODE No. APPLICABLE INDOOR MODEL No. V / ø / HzSPW-CR1503GDYH8 85401575SPW - K(R) · AS(R) · S(R)· UR · F(R)· FM(R) · SLR93GH56OUTDOORSPW-CR1903GDYH8 85401576SPW - X(R) · K(R) · AS(R) · S(R)· UR · F(R)· FM(R) · SLR123GH56380 - 415 / 3 ø / 50S …
  • LG

    Multi V

    (25 pages)
    INSTALLATION MANUALAIR CONDITIONER • Please read this installation manual completely before installing the product.• Installation work must be performed in accordance with the national wiring standards by authorized personnel only.• Please retain this installation manual for future reference after reading it thoroughly.P/NO : MFL67798106www.lg.com …
  • ECG

    MK 124

    (76 pages)
     Před uvedením výrobku do provozu si důkladně pročtěte tento návod a bezpečnostní pokyny, které jsou vtomto návodu obsaženy. Návod musí být vždy přiložen kpřístroji.  Pred uvedením výrobku do prevádzky si dôkladne prečítajte tento návod abezpečnostné pokyny, ktoré sú v tomto návode obsiahnuté. Návod …
  • Samsung

    AVMDH(C)

    (16 pages)
    USER’S MANUALSystem Air ConditionerE S F I P D G R DB98-05146A(6)Silhouette duct : AVMDH(C)✴✴High static pressure duct : AVMHH(C)✴✴E§§HNIKAENGLISHESPAÑOLFRANÇAISITALIANODEUTSCHPORTUGUÊSRUSSIANDuct Type Series AVMDH052CA0 IB_E_05146 2006.5.12 3:43 PM Page 17 …
  • Midea

    MSMBB-12CRDN1-MP0W

    (70 pages)
    Revision A: 1502250001, Content updated. National Electrical Code NFPA70/ANSI C1-1993 or current edition and Canadian Electrical Code Part1 CSA C.22.1. • The information contained in the manual is intended for use by a qualified service technician familiar with safety procedures and equipped with the proper tools and test instruments • Installatio …
  • Airwell

    DLS series

    (14 pages)
    FRANÇAISCLIMATISEUR CENTRALISÉ - SYSTÈME SPLIT AVEC CONTRÔLE ÉLECTRONIQUE - SÉRIE DNG ENGLISHCENTRAL AIR CONDITIONER WITH ELECTRONIC CONTROL SPLIT SYSTEM: SERIES DNG DEUTSCHZENTRALKLIMAANLAGE - SPLITSYSTEM MIT ELEKTRONISCHER KONTROLLE - SERIE DNG E S P A Ñ O L ACONDICIONADOR DE AIRE CENTRAL DEL TIPO “SPLIT”CONTROL ELECTRÓNICO - SERIE DNG I T A L …

Comments, Questions and Opinions: