  • Panasonic KX-TD612CE, Installation Installation Manual 41 2.4.4 EXtra Device Port (XDP)/Parallelled Telephone Connection A Panasonic digital proprietary telephone and a single line telephone, including a facsimile, cordless telephone, etc., can be connected to 1 extension jack in parallel. There are 2 types of parallel connections. • EXtra Device Port (XDP) A digital proprietary telephone and a single line telephone can be connected to the same extension jack yet have different extension numbers. System programming is required. • Parallelled Telephone Connectio

  • Panasonic KX-TD612CE, Installation 36 Installation Manual 2.4.2 Lightning Protector Installation A lightning protector is a device to be installed on a CO line to prevent a dangerous surge from entering the building and damaging equipment. A dangerous surge can occur if a telephone line comes in contact with a power line. Trouble due to lightning surges have been showing a steady increase with the development of electronic equipment. In many countries, there are regulations requiring the installation of a lightning protector. A lightning strike to a telephone cable which is 10 m above ground can be as

  • Panasonic KX-TD612CE, Installation Installation Manual 77 2.11 System Data Clear 2.11.1 System Data Default Set When the system does not operate properly after restarting, you can clear the programming data stored in the system. The system will restart with the default setting. First, try the operation by following step 4 in section 2.7.1 Starting the System for the First Time. If the system still does not operate properly, please follow the procedure below. 1. Slide the system clear switch to the "CLEAR" position. 2. Press the reset button (with a pointed tool, if necessary). 3. While the power indicator starts flashing (within about 10 seconds), return the system clear switch to the "NO

  • Installation 42 Installation Manual Method 1: Using a DPT Jack 2-conductor wiring cord Connect pins "T" and "R". Digital Proprietary Telephone Single Line Telephone 4-conductor wiring cord Connect pins "T", "R", "H" and "L". <Back of the KX-T7200 Series DPTs> Connectors of the DPT outlets (RJ11) To system T

  • Panasonic KX-TD612CE, Installation Installation Manual 55 2.5 Optional Cards and Units Installation 2.5.1 Location of Optional Cards The location of the optional cards is shown below. Precaution To protect the printed circuit boards (P-boards) from static electricity, do not touch parts on the P-boards in the main unit and on the optional cards. If accessing the parts is required, wear a grounding strap. CAUTION • Power off the system, and unplug the AC cord before installing an optional card. 1 BRI Expansio n (KX-TD61280) Connector The front covers are open. Optional Card Connector Voice Message Card (KX-TD61291) Connector Optional Doorphone/Door Opener Card (KX-TD61260

  • Panasonic KX-TD612CE, Table of Contents Installation Manual 9 2.10.1 System Restart...........................................................................................................76 2.11 System Data Clear......................................................................................................77 2.11.1 System Data Default Set............................................................................................77 3 Troubleshooting 3.1 Troubleshooting ..................................................................................................

  • Panasonic KX-TD612CE, Installation 58 Installation Manual 2.5.3 Optional BRI Expansion Card and Voice Message Card Installation An optional BRI Expansion Card (KX-TD61280) and Voice Message Card (KX-TD61291) can be installed in the system. 4. When an BRI expansion card is installed, set the jumper cover on the card to the appropriate position, as shown below. 1. Remove the 2 screws. 2. Open the front cover. 3. Attach the card holders to the optional card connectors. Screws Front Cover

  • Panasonic KX-TD612CE, Installation Installation Manual 75 6. Enter the your subscriber number for each port, and then click OK. 7. After assigning the following ISDN data automatically, the information will be displayed. Port Type ([422] ISDN Port Type) Layer 1 Active Mode ([423] ISDN Layer 1 Active Mode) Access Mode ([424] ISDN Configuration) Data Link Mode (L2) ([425] ISDN Data Link Mode) TEI Assign ([426] ISDN TEI Mode) • If you entered unavailable number and failed in ISDN automatic configuration, the assignments should be done manually. • For further information, refer to "Help" of PC programming software.

  • Installation 52 Installation Manual 2.4.9 Printer and PC Connection A user-supplied printer or personal computer (PC) can be connected to the Serial Interface (RS-232C)(9-pin) on the system. The printer is used to print out the SMDR call records and system programming data. The PC is used for system programming. Connect the Serial Interface (RS-232C) connector of the printer or the PC

  • Panasonic KX-TD612CE, System Outline Installation Manual 17 1.3 Specifications 1.3.1 Specifications General Description Item Description System Capacity Initial Maximum Connections* Outside lines Extension lines DSS Console Doorphone Door Opener External Relay External Pager External Music Second Ringer Relay RS-232C Port 2 ISDN (BRI) (1 ISDN CO + 1 ISDN CO/Extension, 4B Channel) 12 (4 DPT+8 SLT) 4 1 (KX-T30865) 1 1 1 1 1 1 3 ISDN (BRI) (1 ISDN CO + 2 ISDN CO/Extension, 6B Channel) +1 Analogue CO line 12 (4 DPT+8 SLT) 4 3 3 1 1 1 1 1 Control Method Stored Prog

  • Panasonic KX-TD612CE, Installation 38 Installation Manual 2.4.3 Extension Connection Wire Specifications The required wire specifications are as follows: 2 or 4-conductor wiring is required for each extension as listed below. There are 4 connection pins: "T" (Tip), "R" (Ring), "L" (Low) and "H" (High). Maximum length of cable The maximum length of the extension line cord (twisted cable) that connects the system and the extension is as follows: Wire Diameter of conductor Solid wire 0.4 — 0.6 mm Telephone Wiring Single line telephones 1 pair wire (T, R) Digital propriet

  • Panasonic KX-TD612CE, Installation 70 Installation Manual 5. Click Ye s , after reading and accepting the license agreement. If you choose No, you cannot install the TD612 PC programming software. 6. Select a folder to save the installed files. (Normally you do not need to change.) Click Next.

  • Panasonic KX-TD612CE, Installation Installation Manual 43 Method 2: Connection through the Modular Socket Modular Socket 2-conductor wiring cord Connect pins "T" and "R". Digital Proprietary Telephone Single Line Telephone 4-conductor wiring cord Connect pins "H" and "L" only. ("T" and "R" are not required.) Modular Socket

  • Panasonic KX-TD612CE, Installation 44 Installation Manual Method 3: Using a Modular T-Adaptor Double Modular Socket 2-conductor wiring cord Connect pins "T" and "R". Digital Proprietary Telephone Single Line Telephone 4-conductor wiring cord For a digital proprietary telephone: Connect pins "H" and "L" only. ("T" and "R" are not required.) Distribution Frame

  • Panasonic KX-TD612CE, Installation Installation Manual 25 2.2.2 Names and Locations AC Inlet Power Switch Power Indicator Extension Connectors External Music Jack ISDN (BRI) Line Modular Jacks Serial Interface (RS-232C) Paging Jack Battery Interface Ground Terminal External Equipment Connector Serial Number KX-TD612XX ABC1234567

  • Panasonic KX-TD612CE, Installation Installation Manual 71 7. Choose a model, a country and a language, and then click Next. 8. Select a programme folder where the software will be held. (Normally, you do not need to change.) Click Next to start installing.

  • Panasonic KX-TD612CE, Installation 62 Installation Manual 2.5.5 Optional Doorphone/Door Opener Card Installation There are 2 types of Doorphone/Door Opener Card (KX-TD61260, KX-TD61261). Maximum number of the connectable equipment is shown below. 1. Remove the 2 screws. 2. Open the front cover. 3. Attach the optional doorphone/door opener card (KX-TD61260, KX-TD61261) to the system and connect the cord to the connector, then secure the screw as shown below. Note Be sure to connect the cord, that the length from the ferrite core is shorter than another side, to the optional doorphone/door opener card. 4. Close the cover. Doorphone/ Door Opener Card Doorpho

  • Panasonic KX-TD612CE, Installation 22 Installation Manual 2.1 Before Installation 2.1.1 Before Installation Please read the following notes concerning installation and connection before installing the system. Safety Installation Instructions When installing telephone wiring, basic safety precautions should always be followed to reduce the risk of fire, electric shock and injury to persons, including the following: 1. Never install telephone wiring during a lightning storm. 2. Never install telephone jacks in wet locations unless the jack is specifically designed for wet locations. 3. Never touch uninsulated telephone wires or terminals unless the telephone line has been disconnected at the net

  • Panasonic KX-TD612CE, Installation Installation Manual 63 Connection Unpack the box and confirm the items below. 1. While pressing down on the hole at the top of the terminal block using a screw driver, insert the required wire into the side hole as shown below. 2. Attach the terminal blocks to each doorphone/door opener connector. a) KX-TD61260 (Two 5-pin Connectors) KX-TD61260 Two 5-pin terminal blocks (No pin in the center) KX-TD61261 Two 8-pin terminal blocks Door Opener 2 (Pin 4 and 5) Door Opener 3 (Pin 4 and 5) Doorphone 2 (Pin 1 and 2) Doorphone

  • Panasonic KX-TD612CE, Installation 48 Installation Manual 2.4.6 External Relay and Second Ringer Relay Connection This PBX has 1 internal relay (with normally-closed and normally-open contacts) to control external equipment which is user-supplied ; in all KX-TD612 documentation, the external equipment is called "External Relay". This PBX also has 1 internal relay to control a second ringer which is user-supplied ; in all KX- TD612 documentation, this second ringer is called "Second Ringer Relay". Never excee

  • Installation Installation Manual 35 3. Connect the line cord from the ISDN (BRI) port 1 to the terminal board or the modular jack from the Central Office. Connect the line cord from the ISDN (BRI) port 2 to the ISDN extensions. • System Programming is required for ISDN (BRI) port 2. • [422] ISDN Port Type (Default: Port 1,2 — CO/Port 3 — Extension) • [423] ISDN

  • Panasonic KX-TD612CE, Installation 24 Installation Manual 2.2 Installation of the Main Unit 2.2.1 Unpacking Unpack the box and confirm the items below. Main Unit 1 AC Cord 1 Screws (for wall mounting) 3 Washers (for wall mounting) 3 Pin Plug 2 8-pin Terminal Block (for extensions) 3 10-pin Terminal Block (for external equipment) 1

  • Troubleshooting 80 Installation Manual 3.1 Troubleshooting 3.1.1 Installation PROBLEM PROBABLE CAUSE POSSIBLE SOLUTION Extension does not operate. Bad printed circuit board. Exchange printed circuit board for another printed circuit board. Bad connection between the system and extension. Take that extension and plug it into the same extension port using a short telephone cord. If

Related Products and Documents (Conference Phone):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sonus 5200 Hardware installation manual sonus/5200-E2V.pdf 08 Aug 2023 60
2 Blomberg TSM 1541 Instruction manual blomberg/tsm-1541-V8V.pdf 16 Oct 2022 22 0.29 Mb
3 Sony VGN-CR510E/N Specifications sony/vgn-cr510e-n-FSE.pdf 28 May 2023 2
4 Honda 2014 Accord EX Technology reference manual honda/2014-accord-ex-V8E.pdf 13 Mar 2024 15 1.51 Mb
5 Philips CD 210 Operation & user’s manual philips/cd-210-J3E.pdf 10 Sep 2022 16
6 ASROCK B75M-GL R2.0 Operation & user’s manual asrock/b75m-gl-r2-0-939.pdf 20 Jan 2023 69 3.97 Mb

Similar Resources:

  • NEC

    Conference Max Plus

    (2 pages)
    TToo CCoonnnneecctt aanndd CChhaarrggee BBaatttteerriieess1. Slide the cover off the battery compartment on the bottom of the pod.2. Connect the battery pack plug into the port in the compartment and insert the battery pack. Slide the cover back into place.3. Connect the power supply/charger to the conferencing pod and plug it into an electrical outlet. …
  • ClearOne

    Converge Pro 840T

    (2 pages)
    LEADING AUDIOCONFERENCINGSOLUTION FORPROFESSIONALINSTALLATIONSCONVERGE PRO 840TAPPLICATIONSConference RoomsBoardroomsCourtroomsDistance Learning FacilitiesConvention Centers and HotelsTraining RoomsTelemedicine FacilitiesHouses of WorshipCONVERGE PRO 840T ADVANTAGESAdvanced Conferencing Feature Set+ Next-generation Acoustical Echo Cancellation> Full bandw …
  • Polycom

    SoundPoint IP 550

    (3 pages)
    SoundPoint IP 550/560 Quick User Guide for 8x8 Virtual Office Service. PM354/1010 03/2011 For more details, see the Polycom SoundPoint IP 550/560 User Guide available at: http://www.8x8.com/Support/BusinessSupport/Documentation.aspx Page | 1 SoundPoint® IP 550/560 Quick User Guide for 8x8 Virtual Office Applies to …
  • SBC

    SBC-125

    (20 pages)
    Users ManualMulti-Function Caller ID SpeakerphoneSBC-125For problems with installation or operation, visit our web site atwww.sbctelephones.com or call 800-400-5156© 2006 Grace Digital Inc., All rights Reserved SBC is a trademark of AT&T Knowledge Ventures, L.P, Licensed to Grace Digital Inc. …
  • Mitel

    6867i

    (2 pages)
    To Place a Call:• Lift the handset, dial the extension orphone number, and then press the dialkey or wait for the call to connect.Dial the extension or phone number and then lift the handset.• Press the button, dial the extension or phone number and then press the dial key or wait for the call to connect. Dial the extension or phone number and then p …
  • Yealink

    CP860

    (2 pages)
    Quick Reference GuideYealink CP860 Conference PhoneGreen Platform 2700 Oregon Road • Northwood, OH 43619 | 1645 West Chester Pike • West Chester, PA 19382 • 1.888.808.6111 | www.telesystem.us5.15.18Available features may vary. Particular feature set is based on the original order and the system administrator’s req …

Comments, Questions and Opinions: