Manualios.com

Ariterm Biomatic+ 20 Installation And Operating Instructions Manual

  • Biomatic+ 20 Boiler
  • mabT.mMjuEzcA
  • Installation And Operating Instructions Manual
  • PDF / Adobe Acrobat Reader
  • 32

Ariterm Biomatic+ 20 Manual Online:

4.9, 2841 votes
Ariterm Biomatic+ 20 User Manual
Ariterm Biomatic+ 20 User Guide
Ariterm Biomatic+ 20 Online Manual

Text of Ariterm Biomatic+ 20 User Guide:

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 23/32 ARITERM-VTT-S-07229-11.1 1. Open the outer and intermediate star knobs and lift off the soot hatch. 2. Lift the lift lever up. 4. Lift the lift lever up, remove the hatch for the convection channel. 3. Lift the rocker switch to the side. 6. Lift off the holder and the springs from the convec- tion. 7. Sweep the convection pipe surface with a brush, remove any ash. Push the brush up and down again. 8. Reinstall all the springs and lifting levers illustrated.

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 7/32 VV KV TV ARITERM-VTT-S-07229-11.1 1. ARITERM BIOMATIC+ 2. 4-WAY VALVE, FLOOR HEATING (RADIATOR HEATING) 3. CONNECTION SET OF THE ADDITIONAL HEATING CIRCUIT (RADIATOR HEATING) 4. HEAT PIPE PUMP, FLOOR HEATING 5. HEAT PIPE PUMP, RADIATOR HEATING 6. FLOOR HEATING NETWORK MANIFOLDS 7. RADIATOR HEATING NETW

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 27/32 ARITERM-VTT-S-07229-11.1 Flue gas temperature - Max CO O 2 CO 2 Combustion efciency Draught mm Blower % Auger % Flue gas temperature - Mean CO O 2 CO 2 Combustion efciency Draught mm Blower % Auger % Flue gas temperature - Min CO O 2 CO 2 Combustion efciency Draught mm Blower % Auger % Dealer / Installer Installer Date After installation, the burner must

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 12/32 ARITERM-VTT-S-07229-11.1 MENU STRUCTURE e following tables give an overview of the messages that may appear on the display of the control unit. ey also indicate which parameters the user is allowed to change freely and which parameters he/she is allowed to change only if instructed to do so by an authorised in- staller. NOTE! Part of the menu options are displayed only when they are active. Menu Setting Description Temperature Boiler xx (80) °C 5-95°C Boiler temperature, set temperature in brackets. Fluegas

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 11/32 ARITERM-VTT-S-07229-11.1 MENU STRUCTURE ABM+20 - v110311 Temperature • Boiler • Flue gas Burner off (on) Residual oxygen Fuel Adjust Outdoor/Heat/Room Menues Auger external • Manual Operating time Adjustment Pellets store Heating circuit Power settings Heating circuit 2 Maintenance Ash removal Cleaning Main menu Menues Maintenance Max Total Low El 1 Min El 2 Operating time Pellets store Estimated time left Feeding factor Comsumtion total Consumtion average Auger external total Alarm pellets min Pellets st

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 24/32 ARITERM-VTT-S-07229-11.1 Wood pellets are renewable bioenergy and provide fuel in a compact and uniform form, which is easy to handle. e moisture content is less than 10%, which means that the pellets do not freeze or become mouldy. No chemical substances are used in the manufacturing process. In- stead, the binding agent is the tree’s own lignin. e pellet diameter is 6 to 12 mm and the length is 10 to 3

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 21/32 ARITERM-VTT-S-07229-11.1 Check every 1-2 years Unfasten the burner primary air ring, which is fastened by means of four screws and nuts. Clean the air vents of the primary ring and remove all ash. At the same time, check the primary air pipe and clean it of ash. The burn cup should be sealed with fireproof sealant. Detach the protective casing of the burner. Check the chain wheels and chains for wear or whether the chain has loosened. Adjust and change as needed. Lubricate the chain with thin oil.

  • ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 16/32 ARITERM-VTT-S-07229-11.1 Menu Setting Description Drop Off, 1-5, 1-7, 6-7 Days when drops are to be carried out. 1-5 = Mon-Fri, 1-7 = Mon-Sun and 6-7 = Sat-Sun Start 00.00 - 24.00 Time at which the drop starts Stop 00.00 - 2

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 17/32 ARITERM-VTT-S-07229-11.1 ROOM TEMPERATURE UNIT, INSTALLATION AND USE - accessories The set room temperature can be changed with the OK button. The value is changed by pressing Plus and Minus. Hold OK pressed 7 seconds, the Service menu comes up, and the following settings can be changed: • Background lighting power (Backlight) • Room temperature sensor calibration (Calib.Room): + 3 °C • The information at the bottom of the display (Info) With the control unit (accessory) one can replace the room t

  • ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 22/32 ARITERM-VTT-S-07229-11.1 Automatic convection cleaning system The boiler is equipped with automatic convection cleaning system that automatically carries out the sweeping at certain intervals. In any case, the convection

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 19/32 ARITERM-VTT-S-07229-11.1 Alarm message / Cause Check that Procedure Alarm control level monitor The level switches have not detected pellets in the burner upper connection even if the external auger has run for four times its operating time. 1. there are pellets in the store. 2. pellets have not accumulated in the drop pipe. 3. the level switches function well. 4. the inclination of the drop pipe is not too steep (over 45º) or too gentle. 5. the motor shaft rotates the auger

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 5/32 1 5 2 4 7 6 3 ARITERM-VTT-S-07229-11.1 Dispening auger Blocking feeder Upper connection Primary air pipe Ignition pipe Auger Burner Fan Pellets are fed to the burner head from below (underfeeding principle) Safety zone against fire in the back Ignition resistance BURNER OPERATING PRINCIPLE Green: The burner is on Red: Alarm (the burner is off) Blinking light: Warning light (do not turn the burner off) Arrow keys: browsing menus / changing setting C but

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 20/32 ARITERM-VTT-S-07229-11.1 GUARANTEE AND DECOMMISSIONING MOST COMMON SPARE PARTS Guarantee For Warranty Issues Ariterm Sweden AB refers to our local Distributor. Decommissioning An end-of-life boiler is suitable for scrapping. Its plastic parts are landfill waste. Product no. Description 5936 Overheat protection EGO 55.33412.010 5356 Gasket 2x183x200, burner 5787 Grundfos UPS 25-40 pump 1544 Boiler tempera

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 9/32 ARITERM-VTT-S-07229-11.1 Burner start-up and stop Turn the burner and the internal pump on from the operating switch. If the flow switch that controls the internal pump is on, set the operating switch to Off mode. The main menu, which shows the temperatures of boiler water and flue gases, will appear on the display. The main menu also shows the S

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 2/32 ARITERM-VTT-S-07229-11.1 Ariterm Biomatic+ is a cost-effective, resistant and environmentally friendly combination of a central heating boiler and a pellet burner intended for use for the heating of single-family detached houses and the production of hot domestic water using pellets. Additional/back- up heat is produced by an incorporated electrical resistance (9 kW). Standard equipment includes an automatic convection cleaning system and an automatic heating circuit regulation system. Detailed technical data can

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 3/32 ARITERM-VTT-S-07229-11.1 TECHNICAL DATA Performance Power with pellets Power with oil (different burner) Combustion efficiency 8-20 kW 20 kW 91% Dimensions Dimensions (width x depth x height) Empty weight Water volume 601 x 944 x 1,509 mm 245 kg 140 l Design and adjustment values Working pressure: boiler Working pressure: heat exchanger Working temperature Recommended underpressure in the combusti- on chamber Production of hot tap water 0.5-1.5 bar m

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 26/32 ARITERM-VTT-S-07229-11.1 DECLARATION OF CONFORMITY The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or part of the district of the authority to be a smoke control area. It is an offence to emit smoke from a chimney of a build- ing, from a furnace or from any fixed boiler if located in a designated smoke control area.

  • Ariterm Biomatic+ 20, ARITERM SWEDEN AB • ARITERM OY • Asennus ja käyttöohje • Installation och driftanvisning • Installation and operating instruction • UK 25.05.2012 • 25/32 ARITERM-VTT-S-07229-11.1 FEEDING SYSTEM Weekly silo PF300 e lightweight silo is an alternative to the self-built silo. e practical PF300 may also be used as intermediate store for pellets. e capacity of the pellet silo is 300 litres and its filling is facilitated by the intermediate grid in the silo. Contrary to the figure, the silo is delivered with a lid. NOTE! More information on the installation of PS300/Feedo can be found in s

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony HS75 Service manual sony/hs75-2DA.pdf 20 Aug 2023 64 1.64 Mb
2 D.T.Systems H20 1810 PLUS Owner's manual d-t-systems/h20-1810-plus-8OH.pdf 17 Mar 2024 24
3 TRENDnet TEW-435BRM - 54MBPS 802.11G Adsl Firewall M Quick installation manual trendnet/tew-435brm-54mbps-802-11g-adsl-firewall-m-79W.pdf 17 Oct 2022 11
4 GeneralAire E1 Owner's manual generalaire/e1-938.pdf 04 Apr 2024 2
5 Yamaha RS90NL Owner's manual yamaha/rs90nl-FGA.pdf 24 Nov 2023 104 7.65 Mb
6 Russound Decora 858 Instruction manual russound/decora-858-78C.pdf 12 Jul 2023 2

Similar Resources:

  • Viessmann

    Vitorond 100

    (48 pages)
    VITOROND 100Installation andService Instructionsfor use by heating contractorVitorond 100VR1 SeriesOil-Fired BoilerHeating input 91 to 140 MBH27 to 41 kWRead and save these in struction sfor fu tu re reference.IMPORTANT5346 537 v1.0 10/2006 …
  • Fleck

    IF 80

    (18 pages)
    BALLON RECHAUFFEURHEATING TANKBOLLITORECV BOILERCALENTADOR ACUMULADORACUMULADOR DE ÁGUA QUENTE IF 80 - 120 - 160 - 200LFRNotice Technique d’Installation et Guide d’UtilisationTechnical Installation Instructions and User GuideManuale tecnico d'installazione e istruzioni per l'usoTechnische handleiding en installatiegidsManual técnico de instal …
  • ferolli

    DIVA HF24

    (80 pages)
    DIVA HFUA - ȱɇɋɌɊɍɄɐȱə Ɂ ȿɄɋɉɅɍȺɌȺɐȱȲ, ɆɈɇɌȺɀɍ ɌȺ ɈȻɋɅɍȽɈȼɍȼȺɇɇəEN - INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCEFR - INSTRUCTIONS D'UTILISATION, D'INSTALLATION ET D'ENTRETIENPL - INSTRUKCJA OBSáUGI, INSTALACJI I KONSERWACJIRO - INSTRUCğIUNI DE UTILIZARE, INSTALARE ùI ÎNTRETINERE TR - KUL …
  • Viessmann

    Vitodens 100-W WB1B Series

    (100 pages)
    Installation and ServiceInstructionsVITODENSd 100-W5600 332 v1.3 08/2012for use by heating contractorVitodens 100-W WB1B Series Wall-Mounted, gas-fired condensing boilerwith optional on demand hot water CombiPLUS KitRead and save these instructionsfor future reference.IMPORTANTPlease file in Service BinderHeating input 37 to 118 MBH 10.8 to 34.5 kWV …
  • Royal Catering

    RC-WBDW9

    (13 pages)
     RC-WBDW9 RC-WBDW6 RC-WBDW21 RC-WBDW14 RC-WBDWC6G RC-WBDW14CG RC-WBDWC6R RC-WBDWC6O RC-WBDW14CR RC-WBDW14COWATERBOILERBEDIENUNGSANLEITUNGUser manual | Instrukcja | Návod k použití | Manuel d´utilisation | Istruzioni per l‘uso | Manual de instrucciones | Használati útmutat | Brugsanvisningexpondo.co …
  • Worcester

    GREENSTAR CDi CLASSIC 29CDi GC

    (20 pages)
    UK/IEUSER INSTRUCTIONSWALL HUNG RSF GAS FIRED CONDENSING COMBINATION BOILERGREENSTAR CDi CLASSICFOR SEALED CENTRAL HEATING SYSTEMS AND MAINS FED DOMESTIC HOT WATER6 720 803 600 (2012/06)The appliances are for use with:Natural Gas or L.P.G. (Catt II type C13 & C33)Natural Gas: 29CDi GC number 47-406-3434CDi GC number 47-406-3638CDi GC number 47-406-3842CD …

Comments, Questions and Opinions: