Orvaldi MSII RT 6-10KVA Operation & User’s Manual

Orvaldi MSII RT 6-10KVA Manual Online:

3.7, 2608 votes
Orvaldi MSII RT 6-10KVA User Manual
Orvaldi MSII RT 6-10KVA User Guide
Orvaldi MSII RT 6-10KVA Online Manual

Text of Orvaldi MSII RT 6-10KVA User Guide:

  • Orvaldi MSII RT 6-10KVA, Parallel Redundancy On-Line UPS User’s Manual 6-10KVA 1 Table of Contents 1. Important Safety Instruction.............................................................................2 1.1. An Important Notice.........................................................................................2 1.2. Storage Instruction............................................................................................4 2. Product Introduction.........

  • Orvaldi MSII RT 6-10KVA, 2 1. Important Safety Instruction 1.1. An Important Notice 1.1.1. For Parallel System installation, please refer to “MSII 6KVA Parallel System Installation Guide” 1.1.2. Because of “LITTLE LEAKAGE CURRENTS” generated by the EMI filter of the UPS, it is necessary to double ensure if the earth of the UPS is properly grounded before AC Mains is connected with. 1.1.3. To ensure safety in all applications where a UPS is hard wired to the Electrical Supply, ensure that the system is installed by a Qualified Electrical Contractor. 1.1.4. The UPS has its own internal energy source (battery). Should the batte

  • Orvaldi MSII RT 6-10KVA, 4 1.1.25. SAVE THESE INSTRUCTIONS - This Manual Contains Important Instructions that should be Followed during Installation and Maintenance of the UPS and Batteries. 1.1.26. Intended for Installation in a Controlled Environment. 1.1.27. Disconnection Device-CAUTION - A disconnect switch shall be provided by others for ac output circuit. To reduce the risk of fire, connect only to a circuit provided with branch circuit over-current protection for 30 amperes for 6Kva and 40 amperes for 8Kva (10Kva See below details) rating in accordance with the National Electric Code, ANSI/NFPA 7

  • Orvaldi MSII RT 6-10KVA, 6 2.1.12. Revolutionary battery management circuit analyzes battery discharging status to adjust battery cut-off point and extend the life of batteries. 2.1.13. Intelligent temperature-controlled fan may not only extend the life of the fan, but also reduce annoying noise because of sudden fan spin. It remains your office quiet and comfortable as usual. 2.1.14. When UPS is out of order, you may read out the possible fault reason from the LCD screen directly, which may reduce down unnecessary repair task a lot. 2.1.15. In case the UPS is

  • 8 17 Next Page 18 Special Function Log in /out 19 Enter or Reconfirmed 20 Utility Input Normal LED 21 Bypass Input Normal LED 22 UPS under Redundancy Mode 23 UPS under ECO Mode 24 UPS Fault or Abnormal Warning LED 25 EPO Emergency Power Off 26 Er05 Battery Weak or Dead 27 Er06 Output Short Circuit 28 Er10 Inverter Over-current

  • Orvaldi MSII RT 6-10KVA, 10 2.3. Panel explanation 2.3.1. Front Panel Function Explanations LCD Display Green LED lights up to indicate the UPS has the capability to run under redundancy mode. Green LED steadily lights up to indicate that the Utility input voltage is within the window; the LED flashes flickeringly to indicate that the Utility input voltage is within the acceptable window. Green LED lights up to indicate Bypass Input is normal. UPS ON/Alarm Silence Go to previous page or change the setting of the UPS. To re-confirm the change of UPS Setting Go to next page UPS OFF Switch Special functions log in/ou

  • Orvaldi MSII RT 6-10KVA, 12 A RS232 Port B Terminal Resistor for Parallel function C CAN Bus Connection Port for Parallel System D Customer Options Slot 1 E Customer Options Slot 2 F Cooling Fan G External Battery Connector H External Charger Connector I Utility Input Breaker CB1 J Bypass Input Breaker CB2 (for Dual Input Model Only) K CAM Switch(Maintenance Bypass Switch) L Input/Output Terminal Block M Fixing Holes for External Charger Cabinet N EPO(Emergency Power Off): Short to enable the function O Thermal breaker for the p

  • Orvaldi MSII RT 6-10KVA, 14 3. Installation and Operation The packing condition and the external outlook of the unit should be inspected carefully before installation. Retain the packing material for future use. 3.1. Unpacking 3.1.1. Take the UPS out of the PE foam. 3.1.2. Unwrap the UPS. 3.1.3. Standard Package includes: ¾ 1 set of Quick Start Manual ¾ 1 set of User's Manual ¾ 1 set of UPS communication software with RS232 cable ¾ 1 set of Metal Accessories Kit for Tower model or RT model as below: 3.1.4. Package for the UPS with Isolation transformer

  • Orvaldi MSII RT 6-10KVA, 16 3.4. Terminal Block Explanation L11L12N1G1L21L23N21L22N22G2 OUTPUT INPUT BYPASS INPUT UTILITY INPUT L11-N1: BYPASS INPUT L12-N1: UTILITY INPUT G1 : INPUT EARTH GROUND N22, L22, N21, L23, L21: UPS OUTPUT G2 : OUT PUT EARTH GROUN D (DIM TYPE ONLY) (DIM TYPE ONLY) 6000C or RT6K model TB1 TB2 RT10K model Tower model 192408SN0000400 TB1 TB2 17 N21 L23 240Vac 120Vac 120Vac 208Vac L21 6KVA (Max) 6KVA (Max) 3KVA (Max) 3KVA (Max) N22 L22 ● L11-N1、B-N1: the terminal for Bypass Input to provide the power source when the UPS is working under bypass mode. ● L12-N1、R-S-T-N1: th

  • Orvaldi MSII RT 6-10KVA, 18 ● Use Mounting Cable Tie to fix cables. 6. Please refer to the specs of input current, output current and recommended conductors listed as below : a. AC input and output (75°C minimum copper wire) b. Battery input Model Maximum Current Conductor Section Torque force 4.5KVA 25A AWG #10 6KVA 33A AWG #9 8KVA 43.4A AWG #8 23 lb-in 10KVA 54.3A AWG #6 23 lb-in Model Maximum Current Conductor Section 4.5KVA 19A AWG #10 6KVA 25A AWG #10 8KVA 33A AWG #10 10KVA 41A AWG #10 External Battery Ext

  • 20 3.5.1.5. Then, the UPS is on Bypass Mode now and it will proceed self- test automatically. If there is no abnormal message occurred, it means the pre-startup of the UPS is successful and the charger starts to charge the batteries. 3.5.1.6. Press the UPS On Switch for approx. 3 seconds, then the Buzzer sounds twice and the LCD display changes from drawing

  • Orvaldi MSII RT 6-10KVA, 22 H * It shows Utility input is “0” and Utility Abnormal. I 3.5.3. Check Measured Values & Figures detected by UPS 3.5.3.1. If you would like to check the measured values & figures detected by the UPS, please use scroll up and scroll down key pads. When you use scroll down key pad, the LCD display will illustrate as Drawing C(Voltage from Utility Input) ÆDrawing I1(Voltage from Bypass Input) Æ Drawing J(Frequency from Utility Input) ÆDrawing K(Frequency from Bypass Input) ÆDrawing L(

  • Orvaldi MSII RT 6-10KVA, 24 O * It shows Battery Voltage. P * It shows UPS Inner Temperature 3.5.4. UPS Default Data and Special Function Execution 3.5.4.1. After UPS completely starts up, press key pad to change the LCD display screen to drawing Q1. Q1 * It shows buzzer “On”. Q2 * It shows buzzer “Off”. 25 3.5.4.2. Press key pad to scroll down the screen and check the UPS settings. The LCD display will show in consequence between Drawing Q1(buzzer) Æ Drawing R1(Self-test) ÆDrawing S1(Bypass Voltage Windows) Æ

  • Orvaldi MSII RT 6-10KVA, 26 T * It shows Frequency Window is +/-3Hz. U * It shows inverter output voltage. V1 * It shows the UPS is operated in “normal mode”. V2 * It shows the UPS is operated in “Eco mode”. V3 * It shows the UPS is operated in “CVCF 50Hz mode”. 27 V4 * It shows the UPS is operated in “CVCF 60Hz mode”. W * It shows Output Voltage Adjustment % from 0% to 3% or -0% to -3%. X * It shows UPS Identification Number. Y * It sh

  • Orvaldi MSII RT 6-10KVA, 28 3.5.4.4. 3.5.5. UPS Default Settings and their alternatives 3.5.5.1. Make sure the UPS is not “On” yet. Press On Switch and scroll down key pads simultaneously for approx. 3 seconds, the buzzer will sound twice, the LCD display screen shows as drawing Q1, then the UPS is under setting mode now. 3.5.5.2. To scroll down the LCD screen, you may refer to Chapter 3.5.4.2 3.5.5.3. Except Buzzer(as drawing Q1 & Q2) and Self-test(as drawings R1 & R2), all the rest default settings may be changed by pressing scroll up key pad. 3.5.5

  • 30 3.5.8.1. It is for UPS maintenance only. A Non-authorized technician is not allowed to operate the following procedures. If there is any damage under unauthorized condition, your warranty will be void immediately. 3.5.8.1.1. Press the Off key pad for approx. 5 seconds, the LCD screen shows as drawing B and the UPS output is on bypass mode. 3.5.8.1.2. Release the cover o

  • Orvaldi MSII RT 6-10KVA, 32 Situation Check Items Solution UPS Red Fault LED lights up Check the error code shown on the LCD screen 1. Er05, & 2. Er06, Er10, Er12 Er28 & 3. EPO 4. Er11, Er33 5. Er14 6. Er15 7. Er16, Er27 8. Er21 9. Er24 10. other error code 1. Check to see if the battery connection is properly done, then re-charge the batteries for 8 hours to see whether the UPS may backup normally; otherwise, consult your local distributor right away. 2. If the CB3 is tripped, please

  • Orvaldi MSII RT 6-10KVA, 34 6. Customer Options Slots 6.1. R2E(2nd RS-232 ) card 6.1.1. CN1 is for RS232 DB9. 6.1.2. For communication protocol, please refer to Chapter 2.4.1 6.1.3. Installation Position: slot1(CHA-CN4) or slot 2(CHB-CN5). 6.2. RSE(RS-485) card 6.2.1. CN1 is for the function of the terminal resistor. Short pin1-2 to enable the function and short pin2-3 to disable it. 6.2.2. CN2 for RS485 and CN3 for remote power. 6.2.3. Definition 6.2.4. Installation Position: slot1. 6.3. USE(USB) card 6.3.1. CN1 for USB. 6.3.2. Definition 6.3.2.1. Comply with USB version 1.0,1.5Mbps 6.3.2.2. Comply w

  • Orvaldi MSII RT 6-10KVA, 36 6.5. SNMP Cards 6.5.1. SNMP/WEB card 6.5.1.1. For installation, please refer to the user’s manual attached with the card. . 6.5.1.2. Installation 6.5.1.3. Position: slot 2(CHB). 6.5.2. Net Agent II Internal Card 6.5.2.1. For installation, please refer to the user’s manual attached with the card. 6.5.2.2. Installation 6.5.2.3. Position: slot 2(CHB). 37 6.6. The Installation of those Interface Cards 1 2 3

  • Orvaldi MSII RT 6-10KVA, 38 7. Replacing Battery Qualified personnel allowed only. 1. Unscrew the bottom of the front panel as indicated in Step. 1 as below. 2. Remove the front panel as indicated in Step 2. 3. Remove the screw of the battery pack fastener as shown in Step 3. 4. Remove the fastener as shown in Step 4. 5. Unplug the hot swappable battery connectors as shown in Step 5. 39 6. Turn the battery pack handle at 90 degree as shown in Step 6. 7. Remove the battery packs from the UPS as shown in Step 7.

  • 40 8. Specifications Model 4500 / 6000 8000 / 8000P 10000 / 10000P INPUT Voltage Window 160~280Vac (1Φ) / 277 – 485Vac (3Φ) * Frequency 45 ~ 65 Hz Phase/Wire Single, Line + Neutral + Ground Power Factor Up to 0.99 at 100% Linear Load Current THD (100% linear load) <6% ** OUTPUT Voltage Window 220/230/240Vac Selectable(208/1

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Airlink101 AWLL3026 Operation & user’s manual airlink101/awll3026-OBA.pdf 26 Aug 2022 27 1.28 Mb
2 NuTone WA6500 Architectural & engineering specifications nutone/wa6500-4WK.pdf 07 Sep 2022 1
3 Hyundai H-1550 Instruction manual hyundai/h-1550-9EK.pdf 21 Jan 2024 15
4 Kenmore 795.78542800 Service manual kenmore/795-78542800-N53.pdf 26 Sep 2023 54
5 Schenker M506 Operation & user’s manual schenker/m506-913.pdf 28 Oct 2022 163
6 Eizo EIZO FlexScan L 551 L551 L551 Specification sheet eizo/eizo-flexscan-l-551-l551-l551-7XW.pdf 08 Oct 2022 2 0.49 Mb

Similar Resources:

  • Salicru

    UPS SLC TWIN PRO series

    (32 pages)
    UNINTERRUPTIBLE POWER SUPPLY (UPS) + LIGHTING FLOW DIMMER STABILIZERS (ILUEST) + SWITCH MODE POWER SUPPLY + STATIC INVERTERS + PHOTOVOLTAIC INVERTERS + VOLTAGE STABILIZERS AND POWER LINE CONDITIONERSUPS SLC TWIN PRO series0.7 to 3 kVAUSER’S MANUALUNINTERRUPTIBLE POWER SUPPLY …
  • Ever

    SINLINE RT XL 1250

    (2 pages)
    >10cm>10cm+5 ÷ +35 °Cmax. 1,8mb. Rear panel:5 61 24 735 61 24 735. DESCRIPTION OF LCD DISPLAY ICONSv3 20150917Type 01SINLINE RT XL 650 SINLINE RT XL 1250SINLINE RT XL 1650SINLINE RT XL 2250SINLINE RT XL 3000SINLINE RT XL 8501. Output sockets PN-E-93201 (10 A)2. Output sockets IEC 320 C13 (10 A): white - controlled black - non-c …
  • HP

    3 Phase UPS

    (115 pages)
    HP 3 Phase UPS User Guide Abstract This document includes installation, configuration, and operation information for the HP 3 Phase UPS. This document is for the person who installs and maintains power products. HP assumes you are qualified in the servicing of high-voltage equipment and trained in recognizing hazards in products with hazardous energy level …
  • Staco Energy

    FirstLine

    (43 pages)
    The FIRSTLINE UPS 25KVA, 30KVA, AND 37.5KVA Form No.003-2323 Rev B 09/04/2009 301 Gaddis Boulevard • Dayton, Ohio 45403 U.S. Toll Free 866-261-1191 (937) 253-1191 • Fax: (937) 253-1723 Web site: www.stacoenergy.com User’s Manual …
  • Tripp Lite

    SmartOnline SU80K

    (6 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: SU80KSmartOnline 80kVA Modular 3-Phase UPS System, On-line Double-Conversion UPS for North America Highlights80,000 VA (80kVA) tower UPS with 4 hot-swappable power modulesN+1 redundant modular architecture helps ensure 100% availability1+1 p …
  • Eaton

    Powerware 3105 UPS

    (2 pages)
    Powerware 3105 UPSUSER'S MANUALFeatures:SAFETY INSTRUCTIONS11 2233 44INSTALLATION AND OPERATION:The Powerware 3105 uninterruptible power system (UPS) protects your sensitive electronic equipment from basic power problems such as power failures, power sags, power surges, and line noise. Eight outlets -Four with surge and battery backup protection-Four wi …

Comments, Questions and Opinions: