Manualios.com

REMKO RKL 290 Operation Manual

REMKO RKL 290 Manual Online:

3.6, 2709 votes
REMKO RKL 290 User Manual
REMKO RKL 290 User Guide
REMKO RKL 290 Online Manual

Text of REMKO RKL 290 User Guide:

  • REMKO RKL 290, Always keep these operating instructions near or on the unit. Read these instructions carefully before setting up/operating the unit!! Our guarantee becomes null and void if the unit is used, set up or maintained improperly, or if modifications are made to the supplied unit without our prior consent. Subject to alterations! Portable Air Conditioner REMKO RKL 290 / REMKO RKL 350 Operating Instructions Contents Page Safety Instructions 4 Transport and Packaging 4 Description of Device 5 Operation 5 Prior t

  • REMKO RKL 290, 4 Safety Instructions Extensive tests have been conducted on the material, functionality and quality of the REMKO portable air conditioner to ensure that it is a high-performance unit with a long service life. Hazards may nevertheless arise if the unit is used by persons not familiar with its operation or if the unit is not used for its intended purpose. Please make sure to follow these instructions: The unit is not suitable for outdoor operation. Do not set up or operate the unit in rooms suscepti- ble to explosions. Ensure that the u

  • REMKO RKL 290, 5 The unit’s primary function is to air-condition rooms. It also filters and dehumidifies the air, thus creating a comfortable climate in the room. In “Fan” mode, the unit can also be used to circulate air with no cooling effect. The units operates fully-automatically and offers a range of other options thanks to its microprocessor con- trol. For example, it can be automatically switched off and on at a preset time via the timer function. The unit is comfortably operated via the control panel on the indoor unit

  • REMKO RKL 290, 6 1 “I / 0” button The unit is switched on or off with button 1. 2 “MODE” button Button 2 is used to switch between “Cooling” mode and “Ventilation” mode. Each time the button is pressed, the speed of the fan changes. The LEDs of display 8 indicate the selected speed. In “Cooling” mode, the unit cools the room to a set value as long as the LED 7 “COMP ON” is lit up. The temperature can be set in a range be- tween 18 and 30°C. The fan speed can be freely selected as follows. Adjusted fan sped: LED �

  • REMKO RKL 290, 7 Infrared Remote Control Inserting the batteries into the remote control Prior to initial operation, the batteries supplied with the unit (2 type AAA batteries) must be inserted into the re- mote control. 1. Slide off the cover of the battery slot on the back of the remote control. 2. Place the batteries in the slot making sure that the polarity is correct. Use the labelling in the slot. 3. Close the cover. General Information The infrared remote control must be protected from moisture. When the unit is switched on, each change in

  • 8 Prior to Initial Operation The unit is set up in the desired location with the air out- let side facing the room. Follow the safety instructions when setting up the unit. Keep doors and windows closed during operation. In case of direct sunlight, make sure to close all curtains and blinds. Recommendations for optimum unit operation. 5 MIN. There must be a mi

  • REMKO RKL 290, 9 Timer Operation The timer can be preset to switch the unit on or off for a maximum of 12 hours. Pressing the “SET” button in- creases the time until the unit is switched on or off by one hour. The number of hours is shown on the display. Timer switches unit off automatically: 1. W hen the un i t i s on, pres s the “SET” button; the “OFF” LED lights up. 2. Set the desired amount of time until the unit is switched off with “SET” button. Keep in mind that after the setting has been made, the display changes to s

  • 10 Cleaning the plastic housing: For cleaning, use only a clean, soft and slightly moist towel to carefully wipe the housing. Please observe the following: Never use chemical cleaners or polish to clean the unit. They can damage the surface. Only use lukewarm water. Maximum 40°C . Make sure that no moisture gets into the unit. This can damage the internal

  • REMKO RKL 290, 11 Troubleshooting This unit has been designed using state-of-the-art manufacturing processes and it has been tested repeatedly to ensure that it is working properly. However, should problems occur, refer to the following list. Unplug the unit from the power supply before performing any work on it! Problem Possible cause Check Remedy The unit does not start or switches itself off automati- cally. Power failure. Are all other electrical compo- nents working? Check current and wait for the device to start again. Defective power

  • REMKO RKL 290, 12 1) Room temperature WB 35°C/DB 24°C 2) Distance 1m Customer Service and Guarantee For the guarantee to be valid, the purchaser or his cus- tomer must completely fill out the “guarantee certificate” enclosed with all units and send it back to REMKO GmbH & Co. KG . The units are repeatedly tested at the production site to ensure that they are working properly. If a malfunction occurs that cannot be eliminated by the operating per- sonnel, please contact your dealer or contact person. Only autho

  • 13 No. Description RKL 290 S-Line RKL 350 S-Line 19 Microswitch 2 (tank) 1107019 1107019 1107019 1107019 20 Evaporator 1107020 1107020 1107020 1107020 21 Compressor cpl. 1107021 1107021 1107022 1107022 22 Control panel foil 1107023 1107023 1107023 1107023 23 Control panel circuit board 1107024 1107024 1107024 1107024 24 Contr

  • REMKO RKL 290, 14 Installation Diagram of the Wall-Lead Through Installation instructions 1. Create a core hole in the outer wall (maximum wall thickness 480 mm) with a diameter of at least 135 mm. Keep an eye out for possible supply lines in this area! 2. Insert the telescope pipe in the wall lead-through that you created so that the outer pipe (100 mm di- ameter) is on the inner side of the wall. To prevent cold bridges, insulate the telescope pipe with a suitable insulation material. 3. Place bricks around the telescope pipe in the core hole so that it is aligned w

  • REMKO RKL 290, REMKO GmbH & Co. KG Air-conditioning and heating technology D-32791 Lage • Im Seelenkamp 12 D-32777 Lage • P.O. Box 1827 Phone +49 5232 606-0 Fax +49 5232 606-260 E-mail [email protected] Internet www.remko.de

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Electrolux FAVORIT 40860 Operation & user’s manual electrolux/favorit-40860-O9E.pdf 27 Sep 2022 48 0.95 Mb
2 Honeywell ADEMCO 4208U Installation and setup manual honeywell/ademco-4208u-A1L.pdf 28 Apr 2023 4
3 Ryobi RTS20 Operator's manual ryobi/rts20-VRZ.pdf 09 Aug 2023 42 7.08 Mb
4 Smeg ST115S Instruction manual smeg/st115s-O3Y.pdf 25 Jan 2023 36
5 LG MU-60PZ90V Specifications lg/mu-60pz90v-XOY.pdf 06 Jun 2023 1
6 Panasonic KX-TCD505E Operating instructions manual panasonic/kx-tcd505e-GUQ.pdf 20 Oct 2022 80 3.3 Mb

Similar Resources:

  • GE

    ANM12

    (8 pages)
    How to getthebestfrom OurAirConditi%nerContenEAdapter Plug3Use and Care ofAir Direction5Air Filter6windowAppliance Registration2cool onlyCare and Cleaning6Condenser Coils6modelsControl Settings4,5NM12Electrical Requirements3Energy Saver Switch4APM15Energy-Saving Tips2IProblem Solver7Repair Service7Safety Instructions2Warranty Back CoverYour Direct Line to Ge …
  • LG

    LP1415WXRSM

    (58 pages)
    www.lg.comWi-Fi MANUALPlease read this manual carefully before operating your set and retain it for future reference.TYPE : PORTABLE AIR CONDITIONERMODEL : LP1415WXRSMAIRCONDITIONERENGLISHESPAÑOL …
  • Samsung

    AST12P4GB/UMG

    (26 pages)
    ENGLISHESPAÑOLFRANÇAISESFADB98-16557A(1)Split-type Room Air Conditioner (Cool)Aire acondicionado doméstico sistema Split (Refrigeración)Climatiseur de type Séparé (Refroidissement)AST12P4GBAST12P4GEAST18P0GBAAST18P0GEAAST24P6GBAAST24P6GEAIndoor unitUST12P4GBUST12P4GEUST18P0GBAUST18P0GEAUST24P6GBAUST24P6GEAOutdoor unitOWNER’S INSTRUCTIONSMANUAL DE INS …
  • Johnson Controls

    JX Series

    (249 pages)
    MINI 2-WAYVARIABLE REFRIGERANT FLOW (VRF) SYSTEMMINI 2-WAYVARIABLE REFRIGERANT FLOW (VRF) SYSTEMENGINEERING GUIDE New Release Form 121.00-EG1 (512)Issue Date: May 25, 2012 …
  • mundoclima

    MVD DC2 Series

    (20 pages)
    EnglishCL23570 to CL23573www.mundoclima.comMVDInstallation and owner's manualConsole MVD DC2ES: "Manual de instalación y usuario" ver:www.mundoclima.com/gama/industrial/caudal-variable/mvd-dc2/z/FR: "Manual d'installation et d'utilisation" voir: www.mundoclima.com/fr/equipements-pour-climatisation/climatisation-gamme-ind …
  • Hitachi

    RAC-D10EX

    (2 pages)
    < S655 : B >261345INDOOR UNIT32mmRemovingAttaching3 Installation of Drain Hose— 1 — — 2 — — 5 — — 6 —— 3 — — 4 — — 8 —20mmOutdoor790mm398mm390mm 200mm200mm24mm26mm297mm130mm130mm304mm210mm530mm48mm45mm52.5mm113mm 113mm16mm52mm60mmø80mm80mm450mmø8060mm50mm3 Cut the heat insulation sheet refrigerating pipe aligning to the7 i …

Comments, Questions and Opinions: