Topaz PWC1211 Installation And Service Manual

  • PWC1211 Air Conditioner
  • maZcZeBtRTi5E
  • Installation And Service Manual
  • PDF / Adobe Acrobat Reader
  • 24

Topaz PWC1211 Manual Online:

3.7, 2365 votes
Topaz PWC1211 User Manual
Topaz PWC1211 User Guide
Topaz PWC1211 Online Manual

Text of Topaz PWC1211 User Guide:

  • GENERAL DESCRIPTION TOPAZ Air Conditioners are designed for applications where outside air is not available and spot cooling or air conditioning is needed. The cord connected Polaris Models range from 10500 BTU/HR to 60100 BTU/HR floor mount configuration to satisfy any space requirements. All models are provided with casters for portability. These model

  • NOMENCLATURE P WC 24 1 2 PORTABLE VOLTAGE WATER-COOLED SINGLE PHASE

  • Topaz PWC1211, 3 2 CFM with free discharge. 3 Sound Pressure, dB at 5 feet, commercial configuration. 1 Nominal Capacity is total BTU/HR at 80°DB/67°WB return air or 85° EWT to 95° LWT(3GPM/Ton) high fan speed. C A 1 f Size 3/8 valve used on models 10, 12, 18, 24 (with 3/8 M flare fitting) 3/4 valve used on model 36, 60 (with 5/8 M flare fitting) gAmps & Watts at 208 volts .... MODEL PWC1011 12 PWC1211 12 PWC1811 12 PWC2412 PWC3612 PWC3632 PWC6012 PWC6032 PWC6034 Nominal Cooling Capacity 1 10,500 13,780 18,840 23,950 36

  • STANDARD FEATURES SERVICEABILITY All Polaris Series units are designed with removable panels to provide full service accessibility. Turn to page 11 “Part Replacement Procedure” for removal of the correct panel when replacing a part. AUTOMATIC WATER VALVE All units are equipped with a direct-acting, re

  • Topaz PWC1211, STATE-OF-THE-ART CONTROLS The electronic thermostat displays room temperature if the cooling system is on. Select the temperature you want by pressing the ▲ or ▼ buttons. (The word COOL and the temperature setting is displayed for 5 seconds). The FAN button controls the evaporator fan motor. In the ON selection, the fan runs continu- ously. In the AUTO selection, the fan cycles with the compressor. The OUTDOOR button is not used in portable air conditioning. The MODE button controls the cooling function by selecting COOL or OFF. The DAY/NIGHT allows

  • Topaz PWC1211, UNIT/MODEL PLUG CONFIGURATION RECEPTACLE 115 VOLT PWC1011, PWC1211, PWC1811 PAC1011, PAC1211, OWC1211, OWC1811, OAC1211, OACH1211 NEMA-5-15R 115 VOLT PAC18, OAC18, OACH18 NEMA 5-20R 208/230 VOLT SINGLE PHASE PAC1012,1212,1812,2412 OAC1212,1812,2412 OACH1212,1812,2412 PWC1012,1212,1812,2412,3612 OWC1212,1812,2412,3612 NEMA 6-20R 208/230 VOLT SINGLE PHASE PAC3612, OAC3612, OACH3612 PWC6012, OWC6012 NEMA 6-30R 208/230 VOLT SINGLE PHASE PAC6012, OAC6012, OACH6012 NEMA 6-50R 208/230 3 PHASE OAC/PAC3632 OACH363

  • Topaz PWC1211, OPTIONAL FEATURES HOSE KIT 10, 25, and 40 foot hose kits with flare connectors to match fittings on units, banded 3-in-one design for easy and convenient installation, are available. When using these hoses in applications with water pres- sures exceeding 50 PSIG, a water pressure reducing valve must be installed in the water supply line prior to the hose kit; otherwise warranty on the hose kits will be void. The water out and condensate of t

  • Topaz PWC1211, UNIT CONSTRUCTION 8 Evaporator blower Evaporator blower motor Thermostat Evaporator coil Fan motor capacitor Evaporator drain pan Drain hose Condensate pump Compressor Dry Base pan Casters Water valve High Pressure Switch Condenser Water Outlet Condenser Condenser Water Inlet Condensate Outlet Electrical Box

  • Topaz PWC1211, INSTALLATION INSTRUCTIONS ELECTRICAL REQUIREMENTS Adhere to the data plate on the back of the unit and make certain that the proper power is used. Refer to the "Specifications" section for voltage and fuse requirements. Make sure that proper wall outlets and re- ceptacles are used as described in "Standard Features" section of this manual. Operating the unit on im- proper voltage will void the warranty. CAUTION: the use of an extension cord must meet amperage requirement and have grounding-type attachment plug and grounding-type connector (load fitting).

  • Topaz PWC1211, PRACTICAL INSTALLATION Proper installation can be achieved by following these simple steps: 1. Turn off cold water supply. 2. Install “T” between faucet of cold water line and supply valve. 3. Connect shut-off valve to “T” branch. 4. Insert a 3/8 pipe nipple in discharge end of water shut-off valve. 5. Thread coupling onto 3/8 pipe nipple and secure. An alternate installation method: Drill a 5/16 diameter hole in the cold water line and attach a saddle valve to the line. Complete installation by following above steps. 10

  • Topaz PWC1211, Evaporator plenum at- taches to unit in place of standard evaporator grille. ACCESSORIES Model Evaporator Plenum Round Duct Size Fits PWC 10 Fits PWC 12 Fits PWC 18 Fits PWC 24 Fits PWC 36 Fits PWC 60 EP-10 10 inch Yes Yes No No No No EP-12 12 inch No No Yes Yes No No EP-16 16 Inch No No No No Yes Yes Maximum Equivalent Feet (ESP) 25 (.15) 25 (.15) 50 (.25) 50 (.25) 50 (.25) 100 (.50) Duct Adaptor Model Round Duct Size PWC 10 PWC 12 PWC 18 PWC 24 PWC 36 PWC 60 DDA-6 6 inch Yes Yes No No No No DDA-10 10 inch

  • Topaz PWC1211, Plug unit in and push FAN button once. This turns the evaporator fan blower on. To turn the blower off, push the FAN button once again. This turns the fan blower off. To change fan speeds, push the fan speed rocker switch up for high speed or down for low speed. FAN ONLY MODE FAN OUTDOOR DAY/NIGHT Robertshaw 72 WAIT 4 MINUTES BEFORE RE-STARTING 12 COOLING CYCLE To operate unit for cooling, push MODE button to dis- play COOL in the window. Push down arrow button multiple times to lower set poin

  • REPLACEMENT PROCEDURE FOR PARTS A. FAN MOTOR 1. Remove cabinet's left-hand (when looking at the front of the unit) side panel. 2. Disconnect motor wires from evaporator contactor and fan speed rocker switch. 3. Remove screws securing motor and O-ring to blower housing. All screws are external and visible. 4. Loose

  • Topaz PWC1211, 4. Disconnect valve from "water in" line. 5. Install new valve, reversing the procedure. F. HIGH PRESSURE CONTROL 1. Follow the first two steps in "E". 2. Remove two screws that retain switch to right side panel. 3. Disconnect wire leads from compressor contactor and condensate pump safety switch. 4. Install new High Pressure Control, reversing the procedure. To gain access to compressor and compressor run capacitor, remove left hand side panel. TROUBLESHOOTING GUIDE The following steps and procedures are recommended for correcting the problems indi

  • Topaz PWC1211, 2. (CAUSE) Thermostat (REMEDY) Examine the control unit for loose wires. Tighten any loose connections. Wait 4-minutes before re-start. 3. (REASON) High Pressure Control cutting turning unit off (FIXING) Check for loose wire connections, broken or burned contacts. If switch is defective, replace. Not enough water flow to unit or water is too warm. 4. (CAUSE) Compressor contactor open or burned. (CURE) Replace 5. (REASON) Refrigerant leak no freon. (REMEDY) Locate leak and repair. Evacuate unit and recharge

  • Topaz PWC1211, PROBLEM: INSUFFICIENT COOLING 1. (CAUSE) Insufficient air flow through evaporator coil due to: A. Dirty air filter in unit B. Dirty evaporator coil C. Ice on evaporator coil D. Obstructed air intake (REMEDY) Correct as noted: A. Clean filter (see "Preventive Maintenance" section of this manual) B. Clean filter with a vacuum cleaner & hose. C. Defrost; turn on fan only. D. Remove obstruction 2. (REASON) IMPROPER SIZING OF UNIT (FIXING) Check to make sure unit is properly sized for load. Add supplemental uni

  • Topaz PWC1211, PROBLEM: WATER LEAKING FROM PAN 1. (CAUSE) Leaky drain pan (REMEDY) Locate leak and repair pan. 2. (CAUSE) Loose evaporator, drain or condensate pump hose (REMEDY) Tighten connections. 3. (CAUSE) Defective condensate pump or excessive lift on pump (REMEDY) Examine to see if elevation exceeds 20 ft. (if it does, a larger pump will be required). Otherwise, change pump if defective. Pump will operate properly against 20 ft. of water total head pressure on pump. If combination of vertical height and horizontal drain line exceeds 20 ft. of water pressure drop, problems will occur. PROBLEM: THERMOSTAT (LCD) LIQUID CRYSTAL DISPLAY WIND

  • Topaz PWC1211, 2. FILTER A clogged filter will cause the unit to operate at greatly reduced efficiencies. We recommend that the filter be inspected on a regular bases every six weeks or more often depending on the environment. The foam filter is located behind the return air grille and can be easily removed by pulling the grille out. The filter must be washed periodically as needed by placing it in a dishwasher or soaking it in a solution of warm water and detergent for 10 minutes. Then rinsing it clean with hot water and shaking excess moisture from filter. 3. CONDENSATE PUMP When servicing pump follow these steps; 1. M

  • Topaz PWC1211, HIGH PRESSURE SWITCH L2 FOR 208/230 L1 G MODELS PWC10, 12, 18, 24, 36, 60 120/1/60 208/230/1/60 May 1, 2002 HIGH RUN CAP NC NO COM R S C COMPRESSOR SAFETY SWITCH RUN CAP L1 L2 T1 T2 01pwcwiredia G Y W RH B O RC C Y G R TERMINAL BLOCK THERMOSTAT COOLING ONLY EVAPORATOR FAN MOTOR HIGH-LO EVAPORATOR FAN SWITCH LOW TERMINAL BLOCK COMPRESSOR CONTACTOR EVAPORATOR MOTOR CONTACTOR N R 24 Volt Coil 24 Volt Coil CONDENSATE PUMP 120 or 230 VOLT TRANSFORMER 24 Volt 120 or 230 Volt 120/1/60 208/230/1/60 POWER CORD RED LIGHT ON CONTROL PANEL LINE VOLTAGE 24 VOLT L1 L2 T1 T2 HARD START KIT STANDARD ON ONLY PWC1811 Hard Start Kit is factory installed only on the PWC1811. 20

  • Topaz PWC1211, G Y W RH B O RC C Y G R MODEL PWC6034 460 VOLT 3 PHASE May 1, 2002 T1 T2 T3 COMPRESSOR COOLING THERMOSTAT TERMINAL BLOCK T1 T2 T3 L1 L2 L3 COMPRESSOR CONTACTOR 24 Volt Coil EVAP FAN MOTOR 230 VOLT L1 L2 T1 T2 EVAP MOTOR CONTACTOR 24 Volt Coil CONDENSATE PUMP 230 Volt TERMINAL BLOCK HI-LO FAN SWITCH HIGH LOW COM HIGH PRESSURE SWITCH RUN CAP R TANK FULL LIGHT JUMPER 460 VOLT 230 VOLT 230v POWER TRANSFORMER 24v CONTROL TRANSFORMER 230 VOLT 24 VOLT L1 L2 L3 G 24 VOLT LINE VOLTAGE N.C. N.O. C 21

  • Topaz PWC1211, HIGH PRESSURE SWITCH L2 L1 MODEL PWC6032 and PWC3632 208/230/3/60 May 1, 2002 HIGH RUN CAP NC NO COM COMPRESSOR SAFETY SWITCH L1 L2 T1 T2 G Y W RH B O RC C Y G R TERMINAL BLOCK THERMOSTAT COOLING ONLY EVAPORATOR FAN MOTOR HIGH-LO EVAPORATOR FAN SWITCH LOW COMPRESSOR CONTACTOR EVAPORATOR MOTOR CONTACTOR L3 R 24 Volt Coil 24 Volt Coil CONDENSATE PUMP 230 VOLT TRANSFORMER 24 Volt 230 Volt 208/230/3/60 POWER CORD RED LIGHT ON CONTROL PANEL LINE VOLTAGE 24 VOLT L1 L2 T1 T2 L3 T3 T1 T2 T3 22

  • Topaz PWC1211, The Manufacturer (OceanAire, Inc.) warrants to the original owner that the Product will be free from defects in material or workmanship for a period not to exceed one (1) year from date of installation. If upon examination by the Manufacturer the Product is shown to have a defect in material or workmanship during the warranty period, the Manufacturer will repair or replace, at its option, that part of the Product which is shown to be defective. The Manufacturer further warrants that the product's compressor-motor will be free from defects in materials

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Austin SEVEN Handbook austin/seven-711.pdf 01 Mar 2023 38
2 Bose Acoustimass HT Owner's manual bose/acoustimass-ht-F57.pdf 31 Oct 2023 16 2.84 Mb
3 Murata M-900 Operation & user’s manual muratec/m-900-WPI.pdf 23 Sep 2022 16
4 Oregon Scientific WMR100NA Quick start manual oregon-scientific/wmr100na-CN6.pdf 16 Nov 2022 1
5 Makita DHP343 Instruction manual makita/dhp343-RW6.pdf 14 Oct 2023 8
6 Blaupunkt MS30BT Owner's manual blaupunkt/ms30bt-72Z.pdf 13 Feb 2024 82

Similar Resources:

  • Daikin

    EWAD TZ

    (20 pages)
    D–EIMAC00907–16EN - 1/20 Inverter Installation, Operation and Maintenance Manual Air cooled chiller with inverter driven screw compressor EWAD~TZ Refrigerant: R-134a Original Instructions Installation, Operation and Maintenance Manual D–EIMAC00907-16EN …
  • LG

    LW8012ER

    (2 pages)
    IT’S ALL ABOUT ANTICIPATION Cool a little while you save a lot. With 8,000 BTUs this unit will save you energy and money while cooling a room up to 350 square feet. Plus, we’ve got you covered with Auto Restart, so when storms, high wind or heat waves cause a power outage, your unit automatically turns back on when power returns.Three powerful cooling an …
  • SCE

    Enviro-Therm SCE-AC10200B460V3

    (17 pages)
    B1SAGINAW CONTROL & ENGINEERING • A/C USER MANUAL 1. User Manual ............................................................................................ p. 2 2. Legal Regulations ................................................................................... p. 2 3. Safety Instructions .................................................... …
  • Bryant

    Preferred Series

    (44 pages)
    Manufacturer reserves the right to discontinue, or change at any time, specifications or designs without notice and without incurring obligations.Catalog No. 04-53551016-01 Printed in U.S.A. Form II551J-4-6-02 Pg 1 1-2020 Replaces: II551J-4-6-01Installation InstructionsCONTENTSSAFETY CONSIDERATIONS . . . . . . . . . . . . . . . . . . . . . 1MODEL NUMBER …
  • Mitsubishi Electric

    PCFY-P-VKM-E

    (64 pages)
    INSTALLATION MANUALFor safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.INSTALLATIONSHANDBUCHAus Sicherheitsgründen und zur richtigen Anwendung vor Installation der Klimaanlage die vorliegende Bedie-nungsanleitung und das Installationshandbuch gründlich durchlesen.MANUEL D …
  • Tectro

    TS 825

    (126 pages)
    TS(CS) 825 - TS(CS) 832 - TS 848TSCS 1025 - TSCS 1032534>19yINSTRUCCIONES DE USOMANUEL D’UTILISATIONOPERATING MANUALISTRUZIONI D’USOGEBRUIKSAANWIJZINGMANUAL DE INSTRUÇÕESNAVODILA ZA UPORABO22036547290108 …

Comments, Questions and Opinions: