Manualios.com

Topaz TZ-12AB Owner's Manual

Topaz TZ-12AB Manual Online:

4.85, 550 votes
Topaz TZ-12AB User Manual
Topaz TZ-12AB User Guide
Topaz TZ-12AB Online Manual

Text of Topaz TZ-12AB User Guide:

  • Topaz TZ-12AB, Owner’s Manual Models: TZ-12AB - TZ-60AB4 1-800-836-7432 Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Rating Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 General Requirements . . . . . . . . . . . . . . . .

  • Topaz TZ-12AB, 3 Portable Air Conditioners Unit Specifications Rating Information SPECIFICATIONS TZ-12AB TZ-18AB TZ-24AB TZ-36AB TZ-60AB TZ-60AB4 Cooling Capacity, BTU/hr 1 11,900 17,200 28,300 41,000 76,500 77,500 Power Supply 2 Volts/Ph/Hz/Amps 115/1/60/15 115/1/60/15 208-230/1/60/20 208-230/1/60/30 208-230/1/60/60 460/3/60/20 Thermostat Control Mechanical Mechanical Mechanical 3 Mechanical 3 Mechanical 3 Mechanical 3 Metering Device TX Valve TX Valve TX Valve TX Valve TX Valve TX Valve Total Power Consumption, kW 1.4 1.4 3.0 4.5 8.9 11.1 Current Consumption, amps 11.9 12 13.2 19.7 38.7 14.0 Recommended Circuit Amps 15.0 15.0 20.0 30.0 60.0 20.0 NEMA Plug Type 5-15P 5-15P 6-20P 6-30P

  • Topaz TZ-12AB, TOPAZ ® Owner’s Manual Inspection 1. Inspect unit on delivery. 2. Report any damage to the delivery carrier. 3. Request a written inspection report from the Claims Inspector to substantiate claim. 4. File claims with the delivery carrier. 5. Compare unit received with description of product ordered. General Description Topaz Portable Air Conditioners are designed to spot cool industrial, commercial, institutional, and construction sites. Six models provide 11,900 to 77,500 BTU/hr. Options include d

  • Topaz TZ-12AB, Manual Temperature-Control System The manual temperature control system allows you to set the desired temperature by simply rotating the WARMER/COOLER dial either left or right. The supply air fan can be set to run continuously whether the cooling circuit cycle is on and off, or can be set to cycle on and off with the cooling circuit. Filter All units are equipped with removable, washable, aluminum-mesh air filters. Located behind the return-air and discharge-air grilles, these can be removed and easily cleaned. Condensate Tank A five-gallon, polyethylene tank in the lower-

  • Topaz TZ-12AB, TOPAZ ® Owner’s Manual Installation Instructions Before Installing Check unit for damage. Air conditioners are inspected at the factory. If any damage has occurred, save the packaging and file a claim with the delivering carrier within fifteen working days. TOPAZ requires minimal installation. Plug unit in proper NEMA receptacle, and it begins to cool immediately. Electrical Supply Determine the proper power by checking unit’s rating plate. Refer to the Specifications section on page 3 for voltage an

  • 7 Portable Air Conditioners Condensate Pump 1. Disconnect unit from power source before attempting to service or remove any component. 2. Be sure floats move freely. Clean as necessary. 3. Remove floats and check for obstructions. Clean as needed. 4. Clean tank with warm water and mild soap when mineral deposits are visible. 5. Check inlet and outlet piping. Clean as nec

  • Topaz TZ-12AB, Troubleshooting Guide S ervice, other than routine maintenance, should be performed by a qualified electrical and refrigeration professional. P roblem Cause Remedy Unit does not run Power interruption Check external power supply. Look for blown fuses or tripped circuit breakers. Reset or replace. Thermostat inoperable Setting may be too high. Check and reset. Thermostat may be out of calibration or defective. Replace. Electrical Panel Check output of transformer. -24-Volt transformer defective (TZ-12AB, 18AB, If not supplying 24 volts, replace. 24AB, 36AB and 60AB only) -Contactor coil defective Replace. -Contacts stuck o

  • Topaz TZ-12AB, 9 Portable Air Conditioners Problem Cause Remedy Insufficient cooling Insufficient airflow through evaporator See Preventive Maintenance section of this manual. coil due to: -Dirty air filter in unit -Clean filter. -Dirty evaporator coil -Clean filter with a vacuum cleaner and hose. -Ice on evaporator coil -Defrost. Run on fan only. -Obstructed air intake -Remove obstruction. -Low refrigerant -Repair leak in system. -Improper Motor Rotation (TZ-60AB4 only) Reverse two of the three power supply leads (See TZ-60AB4. Phase wiring instructions pg. 6) Unit improperly sized C

  • Topaz TZ-12AB, TOPAZ ® Owner’s Manual Installing Replacement Parts Ceiling-Panel Duct Kit 1. Secure one end of the duct to the ceiling-panel adapter and the other end over the unit’s duct collar. 2. Place the ceiling-panel adapter under suspended ceiling panel’s framework directly above unit. Condensate Pump 1. Unplug unit from power source. Remove condensate tank and hose from drain pan. 2. Place condensate pump on condensate-tank shelf. Align holes in shelf with mount ing slots in molded tank. Secure pump to con den sate-tank shelf using

  • 11 Portable Air Conditioners NK-1 two, 4-in nozzles with attachment kit, TZ-12AB NK-2 two, 6-in nozzles with attachment kit, TZ-18AB, TZ-24AB and TZ-36AB NK-3 two, 8-in nozzles with attachment kit, TZ-60AB and TZ-60AB4 CK-1 10-in ceiling discharge kit, TZ-12AB CK-3 14-in ceiling discharge kit, TZ-18AB, TZ-24AB and TZ-36AB CK-4 20-in ceiling discharge kit, TZ-60AB and TZ-60AB

  • Topaz TZ-12AB, TOPAZ ® Owner’s Manual Description Part Number TZ-12AB TZ-18AB TZ-24AB TZ-36AB TZ-60AB TZ-60AB4 service valve, 5/16-in 88400.284 • • service valve, 3/8-in 88400.249 • service valve, 1/2-in 88400.250 • • • • • • service valve, 5/8-in 88400.251 service valve, 3/4-in 88400.252 • service valve, 7/8-in 88400.256 • • lter drier 83201.043 • • • 83201.044 • 83200.169 • • expansion valve 88400.477 • 88400.478 • 88400.479 • • 88400.480 • • evaporator blower & motor assembly 83100.102 • 83100.159

  • Topaz TZ-12AB, 13 Description Part Number TZ-12AB TZ-18AB TZ-24AB TZ-36AB TZ-60AB TZ-60AB4 door handle 83800.004 • • condensate-pan switch 87500.128 • • • • • • evaporator lter 83200.171 • 83200.172 • • 83200.173 • 83200.174 • • condenser lter 83200.160 • 83200.161 •• 83200.162 • 83200.175 • • evaporator coil 81400.301 • 81400.303 • • 81400.305 • 81400.298 • • condenser coil 81400.302 • 81400.304 • • 81400.306 • 81400.299 • • 2-in caster, (2) per unit 81000.031 • 2-in swivel caster, (2) per

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Canon T70 Instructions manual canon/t70-76R.pdf 08 Jun 2023 76
2 Maxon S5E PMR446 Operation & user’s manual maxon/s5e-pmr446-47I.pdf 03 May 2023 18
3 D-Link Storage Operation & user’s manual d-link/storage-W83.pdf 03 Sep 2022 46 5.17 Mb
4 EnGenius M5000 Datasheet engenius/m5000-389.pdf 22 Jan 2024 6 0.62 Mb
5 HP Compaq Presario,Presario CQ5110F Operation & user’s manual hp/compaq-presario-presario-cq5110f-31C.pdf 24 Sep 2023 126
6 Mitsubishi Electric PUMY-P112VKM1 Service manual mitsubishi-electric/pumy-p112vkm1-1R2.pdf 15 Nov 2023 156

Similar Resources:

  • Mitsubishi Electric

    PLFY-P-VAM-E

    (36 pages)
    EnglishPortuguêsINSTALLATION MANUALFor safe and correct use, please read this installation manual thoroughly before installing the air-conditionerunit.MANUAL DE INSTALAÇÃOPara segurança e utilização correctas, leia atentamente este manual de instalação antes de instalar a unidadede ar condicionado.FOR INSTALLERPARA O INSTALADORAir-Conditioners For Bu …
  • Thermal Zone

    420-0030

    (14 pages)
    Page 1 of 14 WINDOW AIR CONDITIONER INSTALLATION AND OPERATION 950-0129-revA 03-03-09 CATALOG NO. PRODUCT CODE WAC6115RB 420-0030 WAC8115RB 420-0031 …
  • Amana

    RCE Prestige

    (12 pages)
    www.amana-hac.comSpecifi cation Sheet14 SEERRCE Prestige™Split System Air ConditionerHigh-effi ciency Copeland Scroll Compressor with Factory-installed Sound Blanket. Compressor is hermetically sealed and features safeguards to protect it from excessive temperatures, pressure and abnormal electrical currents. In addition, energy-saving design reduces int …
  • Mitsubishi Electric

    PUHZ-FRP71VHA

    (104 pages)
    SERVICE MANUALNo.OCH544SPLIT-TYPE, HEAT PUMP AIR CONDITIONERSR410AAugust 2013Outdoor unit[Model name]PUHZ-FRP71VHA[Service Ref.]PUHZ-FRP71VHAPUHZ-FRP71VHAPARTS CATALOG (OCB544)CONTENTS1. REFERENCE MANUAL ·································22. SAFETY PRECAUTION ·································3 …
  • Mitsubishi Electric

    MSC-GA25VB- E1

    (24 pages)
    SERVICE MANUALCONTENTS1. TECHNICAL CHANGES ····································32. PART NAMES AND FUNCTIONS······················33. SPECIFICATION·················································54. NOISE CRITERIA CURVES················� …
  • Mitsubishi Electric

    par-u02meda

    (272 pages)
    CITY MULTI Control SystemSmart ME Controller PAR-U02MEDAInstallation ManualPrior to use, thoroughly read the instructions in this manual to use the product correctly. Retain this manual for future reference.Make sure that the CD-ROM, this manual, and Simple Operation Manual are passed on to any future users.To ensure safety and proper operation of the remote …

Comments, Questions and Opinions: