Topaz TZ-12B Owner's Manual
|
Topaz TZ-12B, 1-800-836-7432 Unit Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Rating Information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 General Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4 General Requirements . . . . . . . . . . . . . . . . . . . . . . . . . .
Topaz TZ-12B, 3 Portable Air Conditioners Unit Specifications Rating Information SPECIFICATIONS TZ-12B TZ-18B Cooling Capacity, BTU/hr 1 11,900 17,300 power supply 2 Volts/ph/Hz/amps 115/1/60/15 115/1/60/15 Thermostat control Mechanical 3 Mechanical 3 Metering device TX Valve TX Valve Total power consumption, kW 1.4 1.4 Current consumption, amps 11.9 12.0 Recommended circuit amps 15.0 15.0 NEMA plug type 5-15P 5-15P Evaporator CFM, free discharge 350 500 Condenser CFM 500 1,000 Maximum esp, in wc 0.10 0.10 Maximum duct length, ft 40 40 Condensate-pump head, ft 15
Topaz TZ-12B, TOPAZ ™ Owner’s Manual Inspection 1. Inspect unit on delivery. 2. Report any damage to the delivery carrier. 3. Request a written inspection report from the Claims Inspector to substantiate claim. 4. File claims with the delivery carrier. 5. Compare unit received with description of product ordered. General Description Topaz Portable Air Conditioners are designed to spot cool industrial, commercial, institutional, and construction sites. These Two models provide 11,900 to 17,300 BTU/hr. Options include discharge nozzles to direct conditioned air
Short Cycle Protection Timer The TZ-12B and 18B models are equipped with a short cycle protection timer. The timer provides a five-minute delay before the refrigerant compressor restarts. Under normal conditions, no adjustments are necessary. Manual Temperature-Control System The manual temperature control system allows you to set the desired temperature by simply rotating the COOL/COOLER
Topaz TZ-12B, Installation Instructions Before Installing Check unit for damage. Air conditioners are inspected at the factory. If any damage has occurred, save the packaging and file a claim with the delivering carrier within fifteen working days. TOPAZ requires minimal installation. Plug unit in proper NEMA receptacle, and it begins to cool immediately. Electrical Supply Determine the proper power by checking unit’s rating plate. Refer to the Specifications section on page 3 for voltage and fuse requirements. Use wall outlets and receptacles found in the table below. Operating unit on improper voltages voids the warranty. Note: Extension cords may be used if rated at a min
Topaz TZ-12B, 7 Portable Air Conditioners 5. Check inlet and outlet piping. Clean as necessary. Be sure there are no kinks in the lines that can inhibit flow. 6. Exterior of the unit can be cleaned with a damp cloth. Do not allow water to enter condenser fan outlet or the thermostat.
Topaz TZ-12B, Troubleshooting Guide S ervice, other than routine maintenance, should be performed by a qualified electrical and refrigeration professional. P roblem Cause Remedy Unit does not run Power interruption Check external power supply. Look for blown fuses or tripped circuit breakers. Reset or replace. Thermostat inoperable Setting may be too high. Check and reset. Thermostat may be out of calibration or defective. Replace. Electrical Panel Check output of transformer. -24-Volt transformer defective If not supplying 24 volts, replace. -Contactor coil defective Replace. -Contacts stuck open, burned or dirty Correct or change. -Wires loose Tighten connections. Eva
Topaz TZ-12B, 9 Portable Air Conditioners Problem Cause Remedy Insufficient cooling Insufficient airflow through evaporator See Preventive Maintenance section of this manual. coil due to: -Dirty air filter in unit -Replace filter. -Dirty evaporator coil -Clean coil with a vacuum cleaner and hose. -Ice on evaporator coil -Defrost. Run on fan only. -Obstructed air intake -Remove obstruction. -Low refrigerant -Repair leak in system. Unit improperly sized Check to assure unit is sized for load. Add supplemental unit if required. Noisy operation Copper tubing vibrating Adjust by be
Topaz TZ-12B, TOPAZ ™ Owner’s Manual Installing Replacement Parts Ceiling-Panel Duct Kit 1. Secure one end of the duct to the ceiling-panel adapter and the other end over the unit’s duct collar. 2. Place the ceiling-panel adapter under suspended ceiling panel’s framework directly above unit. Condensate Pump 1. Unplug unit from power source. Remove condensate tank and hose from drain pan. 2. Place condensate pump on condensate-tank shelf. Align holes in shelf with mounting slots in molded tank. Secure pump to condensate-tank shelf using two supplied sheet metal screws. 3. Remove electrical plug and jumper wire from recep- tacle located on bulkhead next to the service fittings. 4. C
11 Portable Air Conditioners Accessories Part Description NK-1 two, 4-in nozzles with attachment kit, TZ-12B NK-2 two, 6-in nozzles with attachment kit, TZ-18B CK-1 10-in ceiling discharge kit, TZ-12B CK-3 14-in ceiling discharge kit, TZ-18B PC-1 condensate pump, 115 volt, TZ-12B and TZ-18B CP-1B 10-in condenser return-air plenum, TZ-12B CP-2B 14-in condenser return-
Topaz TZ-12B, TOPAZ ™ Owner’s Manual D escription Part Number TZ-12B TZ-18B service valve, 5/16-in 88400.284 • • service valve, 1/2-in 88400.250 • • lter drier 83201.043 • • expansion valve 88400.477 • 88400.478 • evaporator blower & motor assembly 83100.102 • 83100.159 • condenser blower & motor assembly 83100.116 • 83100.205 • compressor 82200.023 • 82200.028 • evaporator-motor capacitor 85601.713 • 85601.724 • condenser-motor capacitor 85601.724 • 85601.733 • compressor-motor capacitor 85
DOWNLOAD |
Topaz TZ-12A Air Conditioner Owner's manual
TZ-12A |
Spheros CC335SL Air Conditioner Operation manual
CC335SL |
Topaz PWC1211 Air Conditioner Installation and service manual
PWC1211 |
Trotec PAC 2300 X Air Conditioner Operating manual
PAC 2300 X |
LG ARNU123TNC2 Air Conditioner Manual
ARNU123TNC2 |
Daewoo DSB-F154LH Air Conditioner Owner's manual
DSB-F154LH |
Samsung SCD180 Air Conditioner Service manual
SCD180 |
Sanyo KS2432A Air Conditioner Service manual
KS2432A |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Roland | JC-60 | Instructions manual | roland/jc-60-9Y2.pdf | 10 Jul 2023 | 10 | 1.32 Mb |
2 | Summit | SEH3630 | Instruction manual | summit/seh3630-M26.pdf | 26 Dec 2022 | 12 | 2.07 Mb |
3 | Fervi | 0759 | Operation and service manual | fervi/0759-34H.pdf | 01 May 2023 | 29 | |
4 | Epson | WF-8090 | Operation & user’s manual | epson/wf-8090-L7Y.pdf | 17 Oct 2023 | 312 | |
5 | 3DR | Solo | Operation manual | 3dr/solo-WH2.pdf | 29 Dec 2023 | 24 | |
6 | Lombardini | 9 LD 561-2 | Use and maintenance | lombardini/9-ld-561-2-JD4.pdf | 07 Aug 2022 | 109 |
Fujitsu
EnglishINSTALLATION MANUAL РУКОВОДСТВО ПО УСТАНОВКЕOUTDOOR UNIT ВНЕШНИЙ МОДУЛЬFor authorized service personnel only. Только для авторизованного обслуживающего персонала.PART No. 9380545248-02AJY126LELAHAJY144LELAHAJH126LELAHAJH144LELAH[Original instructions]9380545248-02_ …
AIRSTAGE AJY126LELAH(19 pages) |
SCE
B1SAGINAW CONTROL & ENGINEERING • A/C USER MANUAL 1. User Manual ............................................................................................ p. 2 2. Legal Regulations ................................................................................... p. 2 3. Safety Instructions .................................................... …
Enviro-Therm SCE-TE510B24VSS(15 pages) |
Wilfa
Ugit officia porem et ent, inctorem resent volorumqui bearum corestota et ut am quo magnihitae. Air onditionerBruksanvisning BruksanvisningBrugsanvisningKäyttöohjeInstruction manualAC-7W, AC-9WSval 7w, Sval 9wc
…
AC-7W(36 pages) |
Fujitsu
EnglishFrançaisEspañolINSTALLATION MANUALINDOOR UNIT (Duct Type)For authorized service personnel only.PART NO. 9373870135-03ARUH36TLAV ARUH48TLAVARUH60TLAVMANUEL D’INSTALLATIONMANUAL DE INSTALACIÓNAPPAREIL INTÉRIEUR (type conduit)UNIDAD INTERIOR (Tipo conducto)Pour le personnel agréé uniquement.Únicamente para personal de servicio autorizado.9373870 …
Airstage VR-II ARUH36TLAV(15 pages) |
Panasonic
EcoVent Ventilation FansFV-07VBA1 – Fan Housing FV-07VBB1 – Motor/Grille AssemblyFV-07VBA1 + FV-07VBB1 Universal-Can (U-Can) Contractor Packn Ideal for new residential constructionn 70 CFM, cost effective ENERGY STAR solution – 1.1 sones at 0.1" w.g. (56 CFM/1.4 sones @ 0.25" w.g.) n Unique Veri-Boost™ integral switch ensures the fan meets …
FV-07VBA1(2 pages) |
Perfect Aire
Split System Air ConditionerUSER’S MANUALIMPORTANT SAFETY INFORMATION WARNING:To avoid possible equipment damage, fire, or death, the following instructions must be observed regarding unit maintenance and operational procedures.Please read all information in this manual thoroughly and become familiar with the capabilities and use of your appliance before …
JS4BD Series(4 pages) |
Toro Lawn Mower Z Master 74925TEOperator's manual for Toro Z Master 74925TE Lawn Mower Z Master 74925TE, 72 |
Xuum Media Player Dual CoreMedia Player PDF Operation & user’s manual Dual Core, 24 |
Match Speaker System MS 62C-VW.1Manual for Match MS 62C-VW.1 Speaker System MS 62C-VW.1, 12 |
Samsung Camcorder VP-L800Samsung Camcorder Owner's instruction manual (File: samsung-vp-l800-camcorder-71, 15th Jan 2024) VP-L800, 71 |
Ingersoll-Rand Water Pump 670003-XWater Pump Description (Ingersoll-Rand 670003-X) 670003-X, 1 |
Philips Recording Equipment CDR 765Philips Recording Equipment CDR 765 Bedienungsanleitung CDR 765, 24 |
Life Fitness Treadmill Arctic Silver T9Life Fitness Treadmill Arctic Silver T9 Parts manual Arctic Silver T9, 20 |
Lionel Toy AEC - 57 SwitcherToy PDF Owner's manual AEC - 57 Switcher, 12 |
Chamberlain Remote Starter LiftMaster 466LMPDF User Guide (@72Y96J), Chamberlain LiftMaster 466LM Remote Starter (02/01/2024) LiftMaster 466LM, 1 |
Zanussi Microwave Oven ZM17MLZanussi ZM17ML Guide (Doc Type: Microwave Oven Operation & user’s manual) ZM17ML, 120 |
Intel Processor Pentium II XeonPentium II Xeon (Processor ePDF User Manual, #798Z4K) Pentium II Xeon, 4 |
Toshiba Laptop Tecra A7-S712Toshiba Tecra A7-S712 User Guide (Doc Type: Laptop Specifications) Tecra A7-S712, 8 |