Manualios.com

Xtreme 1000VA User & Installation Manual

Xtreme 1000VA Manual Online:

3.95, 602 votes
Xtreme 1000VA User Manual
Xtreme 1000VA User Guide
Xtreme 1000VA Online Manual

Text of Xtreme 1000VA User Guide:

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 14 Uninterrupble Power Supply Determining The Power Requirements Of Your Equipment 1. Make sure the total Volt-Amp (VA) requirements of your connected equipment does not exceed the maxi- mum VA rang for the UPS. The maximum VA rangs are shown in the Specicaons secon of this docu- ment. 2. Ensure that the equipment plugged into the baery-powered outlets does not exceed the UPS rated ca- pacity. If UPS rated capacies are exceeded, an overload condion may occur and cause the UPS to shut down and trip the circuit breaker. 3. If the powe

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 29 Uninterrupble Power Supply Troubleshoong Issue Audible Alarm Alarm Descripon What You Should Do The “Input” leers in the second row of the LCD are ashing Two Beeps per second at startup for 8 total seconds The Input Voltage or frequency may be beyond the normal acceptable range. Verify that ulity voltage and frequency is within acceptable range. If so, contact support. The “Input” leers in the second row of the LCD are ashing One beep per 2 minutes Possible m

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 36 Uninterrupble Power Supply product. Only those devices registered in that manner will be covered. 2. All Connected Equipment must be UL or CSA approved. 3. The Product must be plugged into a properly wired and grounded outlet. Use of input surge devices, ex- tension cords, adapters, ground wires, or electrical connecons not manufactured by XPC voids the XPC Load Protecon Policy. No other surge protecon device may be connected to the output sockets of the Product. The installaon must comply with all applicable electrical and safety codes set forth pursuant to the NEC. 4. The

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 43 Uninterrupble Power Supply NOTE: If the EBP is going to be out of service or stored for six months or longer, the baeries must be re- charged for at least 36 hours every six months. Extended Baery Pack Q & A 1. Which EBP’s do I connect to an AC input source? • It is recommended that every third EBP be connected to incoming AC ulity to properly charge the bat- teries in a complete system. Leaving too many chargers connected may cause an over charge situaon which could damage the baeries and void the warranty. 2. Which LED’s are supposed to be lit on the front of each EBP? •

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 23 Uninterrupble Power Supply INITIAL CONNECTION AND STARTUP Ensure that the UPS and oponal baery packs are mounted correctly, and the UPS is disconnected from input power before proceeding. 1. Connect external baery packs (opon) CAUTION: CONNECT ONLY BATTERY PACKS PROVIDING THE SAME DC VOLTAGE AS THE UPS – PLEASE DOUBLE CHECK LABELING ON THE UPS AND BATTERY PACKS TO ASSURE PROPER VOLTAGES ARE CON- NECTED. CONNECTING THE INCORECT BATTERY PACK TO THE UPS MAY RESULT IN DAMAGE TO THE UPS AND/OR BATTERY PACK THAT WILL VOID THE WARR

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 8 Uninterrupble Power Supply Introducon The informaon provided in this manual covers single phase 1000-3000 VA uninterrupble power systems, their basic funcons, operang procedures, opons available and emergency situaons. It also includes informaon on how to ship, store, handle, and install the equipment. Only detailed requirements of the UPS units are described herein, and installaon must be carried out in accordance with this manual. Electrical installaon must also

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 20 Uninterrupble Power Supply Rack-Mount Installaon Steps UPS Rail Installaon Instrucons to 19” Cabinet Step 1 Step 2 Step 3

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 25 Uninterrupble Power Supply User’s Operaons The only operaons that users are permied to do are: • Turning the UPS unit ON or OFF • Operang the user interfaces • Connecng data interface cables • Changing the baeries All such operaons are to be performed exactly as instructed in this manual. The greatest care possible must be taken for any of these operaons, and any change thereof may prove very hazardous to the operator. On/O Buon Funcon Buon Inquiry Buon Turning O the UPS when connected to an AC source •

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 26 Uninterrupble Power Supply Audible Alarm silence in DC Mode or Fault Mode • When the UPS is in DC Mode, the audible alarm will sound every four (4) seconds. Press and hold the “Funcon” Buon for a minimum of two (2) seconds to disable the audible alarm. • When the UPS is in Fault Mode, the audible alarm will connuously sound. Press and hold the “Funcon” Buon for a minimum of two (2) seconds to disable the audible alarm.

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 34 Uninterrupble Power Supply Xtreme Power Conversion Limited Warranty Xtreme Power Conversion (XPC) Corporaon warrants Xtreme Power Conversion equipment, when properly ap- plied and operated within specied condions, against faulty materials or workmanship for a period of three years for NXRT-Series products from the date of purchase. XPC Corporaon warrants internal baeries for a period of three years from the date of purchase. For equipment sites within the

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 15 Uninterrupble Power Supply WARNING! It is strongly recommended that the UPS cabinet not be opened as components have very high voltage and touching those components may be fatal. Only a qualied technician or authorized agent may service the unit. The UPS unit’s output receptacles carry live voltage even when not connected to an input voltage source. The UPS has its own internal energy source. Environment Ensure that all environmental concerns and requirements are met according to specicaons l

  • Xtreme Power Conversion Corporaon NXRT User’s Manual Page 37 Uninterrupble Power Supply must be completed and led with XPC within 30 days. • Mark the Load Protecon Policy RMA number on the Product the Purchaser is returning. • Pack the Product in its original packaging or similar packing materials if the original packaging has been discarded

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 41 Uninterrupble Power Supply EBP2 rear view 2. The EBP’s use a cable shipped with each EBP to “daisy chain” together addional EBP’s to the rst EBP be- ing connected to the UPS in the appropriately labeled connector, or for connecng the rst EBP to the UPS. 3. The AC input cord is for connecng AC ulity to operate the Charger contained in every third EBP.

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 10 Uninterrupble Power Supply System Conguraon The UPS device and the internal baeries make up the system. Depending on the site and load requirements of the installaon, certain addional opons are available for the soluon. Planning a UPS system, the following should be taken into consideraon: • The total demand of the protected system shall dictate the output power rang (VA). Allow a margin for future expansion or calculaon ina

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 7 Uninterrupble Power Supply Special Symbols The following symbols used on the UPS warn you of precauons: RISK OF ELECTRIC SHOCK - Please observe the warning that a risk of electric shock is present CAUTION: REFER TO OPERATOR’S MANUAL - Refer to the operator’s manual for addional informaon, such as important operang and maintenance instrucons. SAFE GROUNDING TERMINAL - Indicates primary safe ground LOAD ON/OFF – Pressing the buon turns on/o the output receptacles and the indicator light. RJ45 RECEPTACLE – The receptacle provides

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 22 Uninterrupble Power Supply Step 7 Note: Any external Baery Packs must be installed next to or under the UPS. Please refer to Appendix A: Baery Pack User Guide for more informaon when installing these.

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 5 Uninterrupble Power Supply EMC Statements - FCC Part 15 Noce: Pursuant to secon 15 of the FCC rules, this product has been tested and thereby complies to the condi- ons of a Class B (NXRT-1000, NXRT-1500) and Class A (NXRT-2000, NXRT-3000) digital device, which have been established for oering sucient protecon against dangerous interference for installaon in a residenal area. Installaon and use of the equipment should comply with

  • Xtreme 1000VA, Xtreme Power Conversion Corporaon NXRT User’s Manual Page 4 Uninterrupble Power Supply Thank you for selecng this Uninterrupble Power Supply (UPS). It provides you with protecon for connected equipment. Please read this manual before installing the NXRT-Series UPS models NXRT-1000, NXRT-1500, NXRT- 2000 and NXRT-3000 as it provides important informaon that should be followed during installaon and main- tenance of the UPS and baeries, allowing you to correctly set up your system for the maximum safety and per- formance. Included is informaon on customer support and service, if it is required.

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Atlona AT-VID18-BNC Operation & user’s manual atlona/at-vid18-bnc-S99.pdf 27 Aug 2022 8
2 Curtis TCT Service manual curtis/tct-GH1.pdf 17 Dec 2022 12
3 Panasonic CZ-RD52CP Operation & user’s manual panasonic/cz-rd52cp-9X9.pdf 14 Feb 2023 26
4 Diamond Multimedia 4870PE5512 Product setup sheet diamond-multimedia/4870pe5512-N53.pdf 02 Jul 2023 2 0.02 Mb
5 Samsung AS07S8GB Owner's instructions manual samsung/as07s8gb-T4P.pdf 29 Dec 2023 24 1.39 Mb
6 Remington BKT3000C Manual  remington/bkt3000c-8Y8.pdf 08 Oct 2023 96 1.33 Mb

Similar Resources:

  • Toshiba

    G9000 SERIES

    (11 pages)
    G9000 SERIES OPTIONAL BYPASS FUSE INSTALLATION GUIDE 480/480 V 1000 kVA Doc. No.: 92932-001 Document: 4GBH0090 Rev. B March 2020 …
  • Tripp Lite

    RBC24-SUTWR

    (2 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: RBC24-SUTWR UPS Replacement Battery Cartridge for select Tripp Lite SmartOnline Tower UPS HighlightsTripp Lite-certified premium battery cartridgePre-assembled and wired battery kit offers simple installationRugged leakproof constructionMain …
  • Tripp Lite

    BP24V70-3U

    (3 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] Number: BP24V70-3UBP24V70-3U - 3U External 24V Rack/Tower Battery Pack for select Tripp Lite UPS Systems HighlightsExtends the runtime of expandable 24V DC Tripp Lite UPS SystemsIncluded daisychain connector supports the addition of multiple co …
  • Online USV

    YUNTO P 500

    (54 pages)
    1 / 54 2/6/2012 Benutzerhandbuch (YUNTO P 500, YUNTO P 750, YUNTO P 1250) Deutschland Italien Schweiz ONLINE USV-Systeme AG Dreimühlenstr.4 D-80469 München Phone +49 (0) 89 / 2423990-10 Fax +49 (0) 89 / 2423990-20 Internet: www.online-usv.de Online UPS Systems S.r.l. Via Edison 12 I-20058 Villasanta (Milano) Phone +39 (0) 39 / …
  • Tripp Lite

    SU1000XL

    (18 pages)
    200408112 93-22801111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comOwner’s Manual1111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comImportant Safety Instructions2Quick Installation3Basic Operation5Storage and Service11Specifications12SmartOnline™Intelligent, True …
  • Njoy

    Balder Series

    (57 pages)
    Balder SeriesUser ManualManual de utilizarePWUP-OL06KBA-AZ01BPWUP-OL10KBA-AZ01B150.1Before using this product, carefully read all product documentation and retain it for future reference. …

Comments, Questions and Opinions: