Manualios.com

Sanyo A11J Instruction Manual

Sanyo A11J Manual Online:

3.7, 2685 votes
Sanyo A11J User Manual
Sanyo A11J User Guide
Sanyo A11J Online Manual

Text of Sanyo A11J User Guide:

  • Sanyo A11J, Operating Procedures 27 § 8 8 . . O O p p e e r r a a t t i i n n g g P P r r o o c c e e d d u u r r e e s s § 8 8 . . 1 1 U U P P S S S S t t a a r r t t u u p p Follow the procedure below to start up the UPS. ② Press . Green: Lit ① Set MAIN MCCB on the front of the UPS to “ON.” Check that “INPUT (Green)” has changed from blinking to always on, and then proceed to step ② . ① Set this to “ON” Green: Blinking Lit

  • Sanyo A11J, Using Operating System Standard UPS Service 41 § § 1 1 3 3 . . U U s s i i n n g g S S t t a a n n d d a a r r d d O O S S U U P P S S S S e e r r v v i i c c e e s s The standard UPS service of the operating system can be used to perform an automatic shutdown when a power outage occurs. Connect the PC I/F connector of the UPS and the serial connector of the computer with the supplied communication cable. When using the standard UPS service of the operating system, set the interface to “Standalone.” For the setting procedure, see §3.5 “Setting PC Interface” in the LCD Panel Operating Manual . Windows 2000/XP/Server 2003

  • Operating Procedures 30 In the case of the shutdown operation only, the operating procedure differs depending on the setting of “Setting UPS Shutdown Operation” in the LCD panel setting menu. For details, see §3.9 “Setting UPS Shutdown Operation” in the LCD Panel Operating Manual . § 8 8 . . 3 3 O O p p e e r r a a t t i i o o n n U U s s i i n

  • Sanyo A11J, Part Names 12 § 5 5 . . 4 4 E E x x t t e e r r n n a a l l I I n n t t e e r r f f a a c c e e s s No. Name Function ① PC I/F PC interface connector (RS-232C) Connect the connector and a computer with the supplied communication cable. This interface functions as follows depending on the setting of “Interface” in the LCD panel setting menu. Select the interface according to the function to be used. For the setting procedure, see §3.5 “Setting PC Interface” in the LCD Panel Operating Manual . 1. Interface set

  • Sanyo A11J, Buzzer Sounds 34 Press to stop the buzzer. Tip § 1 1 0 0 . . B B u u z z z z e e r r S S o o u u n n d d s s The buzzer sounds to indicate a UPS status error or change. Check the sound pattern and see the following table for the countermeasures to take. Sound Pattern LCD Indication LED Status UPS Status Countermeasure Total Unit# Err Fatal Error Red ALARM: Lit Red WARNING: Lit The number of connected UPS units and the setting value differ. Set the number of connected UPS units properly. See §3.19 “Setti

  • Sanyo A11J, Part Names 13 No. Name Function ③ SIGNAL I/F Contact signal interface connector Outputs status information of the UPS such as a power outage or voltage drop. External Transmission Signals and Shutdown Input Signals Signal Name Explanation Pin No. and Status when Operating AC input error This signal is output when there is a power outage or voltage error of the utility power supply. 1-8: ON 2-8: OFF Battery voltage drop This signal is output when the battery voltage drops to or bel

  • Using Operating System Standard UPS Service 42 ④ Click the “Configure...” button. ⑤ Make the settings shown in the following figure, and then click the “OK” button. When you return to the screen in step ① , click “Apply”. No. Item Description A Enable all not

  • Sanyo A11J, Inspection and Maintenance 31 § 9 9 . . I I n n s s p p e e c c t t i i o o n n a a n n d d M M a a i i n n t t e e n n a a n n c c e e CAUTION ! Internal maintenance and inspection should be performed only by technically qualified personnel. Electric shock, injury, burning, fuming or fire could otherwise result. Before beginning inspection, shut down the UPS completely and remove the input power. Failure to do so may result in an electric shock. While the batteries are connected to the equipment, hazardous voltage is present. Never touch any parts with your hand. Doing so may result in electric shock. Ba

  • Sanyo A11J, Preparation Before Operation 25 § 7 7 . . 3 3 P P o o w w e e r r O O u u t t a a g g e e S S i i m m u u l l a a t t i i o o n n T T e e s s t t Perform a power outage test to confirm whether the UPS is working properly. ② Press . ① Set MAIN MCCB on the front of the UPS to “ON.” [Select]=INV ON [Back]=Cancel - ONLINE **** The screen changes after approx. 1 sec . I

  • Sanyo A11J, Safety Precautions 2 § 2 2 . . S S a a f f e e t t y y P P r r e e c c a a u u t t i i o o n n s s PRECAUTIONS (IMPORTANT SAFERY INSTCUTIONS) This manual contains important instructions for operating and maintaining the A11J Series and the batteries to protect the safety of the customers and the service technician. Before installing, operating, performing maintenance or inspecting the UPS, be sure to read this manual and accompanying documents carefully to obtain a clear understanding of the information related to its operation, safety and important precautions. This manual uses two safety warning levels, WARNING and CAUTION, as described

  • Sanyo A11J, Warranty 46 § 1 1 5 5 . . W W a a r r r r a a n n t t y y Warranty for use in Japan: 1 year Warranty for use Overseas: 1 year Warranty for use in North America: 3 years* *Valid only when the UPS is purchased from a vendor recognized by SANYO DENKI 1. In the above areas, this product is warranted for the specified periods against electrical failures due to materials or workmanship. 2. Free repair or replacement by a product with equivalent functions will be made when it is determined that failure has occurred because of defects in materials or workmanship. 3. This warranty is void in the event of any modifications or c

  • Sanyo A11J, Preparation Before Operation 23 § 7 7 . . P P r r e e p p a a r r a a t t i i o o n n B B e e f f o o r r e e O O p p e e r r a a t t i i o o n n § 7 7 . . 1 1 C C h h e e c c k k i i n n g g U U P P S S S S e e t t t t i i n n g g s s See §3. “Setting UPS” of the LCD Panel Operating Manual , and check the settings. The factory default settings of the UPS are indicated by the “ * ” mark in the Default Setting column of the “List of Settings.”

  • Sanyo A11J, Inspection and Maintenance 32 § 9 9 . . 1 1 R R o o u u t t i i n n e e C C h h e e c c k k s s b b y y C C u u s s t t o o m m e e r r CAUTION ! Be sure not to inspect the inside of the UPS. Doing so may result in an electric shock, burn, injury, smoke, or fire. Do not touch the fan on the back of the UPS when cleaning the UPS or anywhere around the UPS. Doing so may result in an injury. Do not use, for example, a wet cloth for cleaning. Doing so may result in electric

  • Sanyo A11J, Using Power Management Software 39 If the installation program does not start automatically, double-click Setup.exe on the CD-ROM to start installation manually. § 1 1 2 2 . . U U s s i i n n g g P P o o w w e e r r M M a a n n a a g g e e m m e e n n t t S S o o f f t t w w a a r r e e Install and use the power management software on your computer. For more information, see the Installation Guide and User Guide in the “PDF” folder on the CD-ROM. ① Check that “Interface” in the LCD panel setting menu is set to “WS” (work

  • Sanyo A11J, Safety Precautions 5 6. Radio Frequency Interference CAUTION This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in the residential area is likely to cause harmful interference in

  • Sanyo A11J, Troubleshooting 37 3/3 UPS Status LCD Indication LED Status Countermeasure Cannot perform a battery test. - - A battery test cannot be performed when: (1) The inverter is stopped. (2) The bypass power supply is active. (3) The battery operation is being performed (4) A shutdown is being performed by, for example, a remote operation. (5) The UPS has malfunctioned. (6) During asynchronous operation When using the power management software, serial communication fails. - - Is “Interface” in the LCD panel setting m

  • Sanyo A11J, Preparation Before Operation 24 § 7 7 . . 2 2 C C h h a a r r g g i i n n g g U U P P S S At initial startup or when the UPS has not been operated for a long period, the batteries installed in the UPS should be charged for at least 18 hours as described in the following procedure. Be sure to charge the UPS before connecting the load devices. Charging of the batteries starts automatically. The UPS should be charged for at least 18 hours to ensure backup in the event of a power outage, bu t load devices can be connected for use when th

  • Sanyo A11J, Installation and Wiring 20 ⑥ Connect the ground to the “ ” terminal of the terminal block. Use D class grounding for the ground. ⑦ Connect the utility power supply to the “INPUT L and N” input terminals. ⑧ Connect the customer’s load devices to the “OUPUT L and N“ output terminals.* ⑨ When you have finished the wiring, check that the connections are not loose. ⑩ Attach the upper cover of te

  • Sanyo A11J, UPS Characteristics 43 § 1 1 4 4 . . U U P P S S C C h h a a r r a a c c t t e e r r i i s s t t i i c c s s § 1 1 4 4 . . 1 1 B B a a s s i i c c O O p p e e r r a a t t i i o o n n (1) When normal operation During normal operation, the UPS converts AC power from the utility power source into DC power through the rectifier, and reconverts this DC power back into AC power through the inverter and supplies it to the load. The output power is stable AC power synchronized with the input power source. The batteries are kept continually charged and ready in case a problem (power outage or voltage drop)

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 AEG SANTO Operating instructions manual aeg/santo-J74.pdf 15 Oct 2022 40 0.4 Mb
2 Intel D845HV Specification intel/d845hv-4P5.pdf 23 Oct 2022 29
3 Sangean DT-220V Brochure sangean/dt-220v-E75.pdf 28 Jan 2023 1 0.48 Mb
4 EVGA GeForce 6200 PCI Specification evga/geforce-6200-pci-4Q5.pdf 03 Mar 2023 1 0.42 Mb
5 Zanussi WDL 1282 Instruction booklet zanussi/wdl-1282-6JU.pdf 15 Sep 2023 40 2.8 Mb
6 HP Compaq Presario,Presario CQ5110F Supplementary manual hp/compaq-presario-presario-cq5110f-EOX.pdf 04 Jul 2022 2

Similar Resources:

  • CyberPower

    OP1500AVR-T4

    (3 pages)
    Office Tower Series with AVR UPS OP1500AVR-T4 User Manual K01-1500A2A SAFETY WARNINGS (SAVE THESE INSTRUCTIONS) This manual contains important safety instructions. Please read and follow all instructions carefully during installation and operation of the unit. Read this manual thoroughly before attempting to unpack, install, or operate your UP …
  • CyberPower

    CyberShield CBN50U48A-1

    (2 pages)
    User’s Manual forCyberShieldCBN50U48A-1CyberShield UPSs are designed to provide a local power solution for cable telephony, wireless local loop (WLL), and fiber to the home(FTTH) broadband equipment. ENCLOSURE INSTALLATION Carefully follow these instructions during installation of this device:1.) Carry out the installation in a safe area that is free of ex …
  • Lamarche

    ODUPS

    (23 pages)
    La Marche Manufacturing Company www.lamarchemfg.com ODUPS Outdoor UPS Installation and Operation Manual This manual is subject to change without notice. You may obtain the newest version of the manual at www.lamarchemfg.com 106 Bradrock Dr. Des Plaines, IL 60018-1967 CPN 144266 …
  • Xtreme Power Conversion

    P90g Series

    (49 pages)
    P90g Online UPS1500VA, 3000VA ModelsUser & Installaon Manualwww.xpcc.com | © 2016 Xtreme Power Conversion Corporaon. All rights reserved. (Rev 5/03/16) …
  • Forza

    HT-752LCD-C

    (5 pages)
    HT-1002LCD-CThis unit is shipped from the factory with its internal battery fully charged; however, some charge may be lost during shipping. Therefore, it is recommended to recharge the battery prior to initial use. Simply plug the unit into an appropriate AC outlet, and allow it to charge to maximum capacity for 6 hours.Important safety instructions SAFE H …
  • Borri

    B400-010-B (C)

    (38 pages)
    B400 Online UPSB400 Online UPSB400 Online UPSB400 Online UPS User Manual B400-010-B (C) B400-020-B (C) B400-030-B (C) 200/208/220/230/240VAC www.upsdirect.com [email protected]  +44 (0)8456 445 002  www.upsdirect.com …

Comments, Questions and Opinions: