Cisco PGW 2200 Software Installation And Configuration Manual
|
3-7 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 3 Installing the Cisco PGW 2200 Softswitch Software Release 9.8 and Higher Installing the Cisco PGW 2200 Softswitch Software Release 9.8 and Higher Releases Updating parameters for db-bulkcp Updating parameters for init.tcl Updating parameters for mgcb
Cisco PGW 2200, 4-15 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 4 Configuring the Cisco PGW 2200 Softswitch Software Configuring SNMP Support Resources Note SNMP managers such as the Cisco Media Gateway Controller Node Manager (Cisco MNM) or HP OpenView can be used to receive traps. Note The config-snmp utility is case-sensitive. It will accept “name1” and “NAME1” as two different entries. Migrating the SNMP Configuration to a More Secure Environment (for Cisco PGW 2200 Softswitch Release 9.3(2) or Later) If your system is running Cisco PGW 2200 Softswitch software version
Cisco PGW 2200, 4-63 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 4 Configuring the Cisco PGW 2200 Softswitch Software Configuring SCP Queries # PS 1: Customer 1 LNP #----------------------------------------------------------------------------------------- ------------------------------------------------------------ 100 1 101 1 102 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #----------------------------------------------------------------------------------------- ------------------------------------------------------------ #
Cisco PGW 2200, 5-15 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 5 Migrating to Solaris 10 and Cisco PGW 2200 Softswitch Software Release 9.8 Migration from Release 9.5 or 9.6 to Release 9.8 without Platform Changes Step 3 Install the Sun Solaris 10 operating system using the procedures in “Loading the Sun Solaris 10 Operating System” section on page 2-3. Caution Do not format or modify the second disk drive. Unless the disk drives were replaced in Step 2, the second disk contains the original Solaris 8 system if you are Veritas Volume Manager. The second disk is used as a fallback in case of a fa
Cisco PGW 2200, 5-21 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 5 Migrating to Solaris 10 and Cisco PGW 2200 Softswitch Software Release 9.8 Migration from Release 9.7 to Release 9.8 without Platform Changes Step 13 Restart PGW host 2 in order to ensure that the changes to the pom.dataSync variable take effect. Migration from Release 9.7 to Release 9.8 without Platform Changes Perform the following procedure to migrate from Cisco PGW 2200 Softswitch Release 9.7 to Release 9.8 without platform changes: Note When replicating the calls from release 9.7 to release 9.8
2-80 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 2 Installing the Sun Solaris 10 Operating System Loading the Sun Solaris 10 Operating Environment Note You can also download the Sparc-based Cisco BAMS archive partition package (CSCOh027) from Cisco.com. For example, download the CSCOh027 package to the /opt
Cisco PGW 2200, A-13 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix A XECfgParm.dat File Parameters Understanding the XECfgParm.dat File Format *.logFileNamePrefix Combined with the .log extension, defines the filename for log files. Default: platform Example: engine Note This setting can also redirect process messages from the default log file to a specified log file. For example, engine.logFileNamePrefix = engine instructs the log server to redirect messages from the engine process to the dedicated engine.log file. This functions with or without *.logDirector
Cisco PGW 2200, D-41 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix D Sample Installation Scripts Sample Configured XECfgParm.dat Files for Cisco PGW 2200 Softswitch Release 9.6(1) # SUA.logPrio = Debug # TALI.logPrio = Debug # TCAP.logPrio = Debug QBE-IOCC.debugFlag = 0 # Specialized "autonomous" flags for debug, fault isolation # engine.autonomous = true # cfgM.autonomous = true Talk2.autonomous = false #-------------- # procM #-------------- procM.
A-4 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix A XECfgParm.dat File Parameters Understanding the XECfgParm.dat File Format *.autonomous Enables a process, for example the engine, to be started without the system. Default: false Note Do not change this value. *.chargingmode Allows you to specify the charging mode for non-
Cisco PGW 2200, D-29 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix D Sample Installation Scripts Sample Configured XECfgParm.dat Files for Cisco PGW 2200 Softswitch Release 9.7(3) *.geoSeparation = false # MIGRATED # To disable sip failover, you have to set both Virtual_IP_Addr* to 0.0.0.0. # Set *.sipFailover = true # MIGRATED # *.sipFailover = true # MIGRATED *.stPort = 0 # MIGRATED engine.SysVirtualSwitch = 1 # MIGRATED pom.dataSync = true # MIGR
Cisco PGW 2200, 2-118 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 2 Installing the Sun Solaris 10 Operating System Loading the Sun Solaris 10 Operating Environment Running a Test in Full Mode When run in full mode, the vts_script tests 100 percent of each disk surface. To run the test in full mode: Step 1 Change directories to the /var/tmp directory. Enter the following command: # cd /var/tmp Step 2 Enter the following command to start the test: # /opt/sun_install/vts_script full vts_script Execution Times Table 2-5 lists estimated execution times for the VTS scripts on a sampling
Cisco PGW 2200, D-17 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix D Sample Installation Scripts Sample Configured XECfgParm.dat Files for Cisco PGW 2200 Softswitch Release 9.8(1) # # All lines beginning with a '#' are comments and WILL NOT BE READ BY # PROGRAMS. Thus application overrides of the default parameter values # can be easily added and removed by removing/added a '#'. # # Copyright (c) 1997-2008 by Cisco Systems, Inc. #------------------------------------------------------------------------------ # Default parameter values have a facility name of "*" and # will be used if no mat
Cisco PGW 2200, 4-83 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 4 Configuring the Cisco PGW 2200 Softswitch Software Configuring SCP Queries 239 1 1 240 0 1 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 #----------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------ ----------------------------------
Cisco PGW 2200, 2-41 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 2 Installing the Sun Solaris 10 Operating System Loading the Sun Solaris 10 Operating System c. Use the arrow keys to move the cursor to your time zone (in this example, “Eastern Time” is selected) and press the space bar to select it. Press ESC-2 to continue. Text similar to the following is displayed: - Date and Time --------------------------------------------------------------- > Accept t
A-39 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix A XECfgParm.dat File Parameters Understanding the XECfgParm.dat File Format ioChanMgr.evtTimer Frequency, in milliseconds, at which the queue is scanned for messages. Default: 100 Note Do not change this value. ioChanMgr.hbTimer This parameter is reserved for future use. ioCh
Cisco PGW 2200, 2-126 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 2 Installing the Sun Solaris 10 Operating System Loading the Sun Solaris 10 Operating Environment
Cisco PGW 2200, F-16 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix F Sample LAN Configurations Sample Configuration for Cisco Catalyst 5500 B standby 3 ip 209.165.200.224 ! interface Vlan4 ip address 209.165.200.224 255.255.255.224 no ip redirects standby 4 timers 1 3 standby 4 preempt standby 4 authentication VSC3000 standby 4 ip 209.165.200.224 ! router eigrp 1 network 209.165.200.224 ! ip classless ! snmp-server community public RO snmp-server community private RW snmp-server chassis-id public snmp-server enable traps snmp snmp-server enable traps appn alert snmp-server enable traps config snmp-server enable traps entity snm
Cisco PGW 2200, 4-82 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 4 Configuring the Cisco PGW 2200 Softswitch Software Configuring SCP Queries # ParameterAssistingSSPIPRoutingAddress, ServiceInteractionIndicators, ItuAsn1EtcLegIDElem,ItuAsn1EtcCallSegmentIDElem,ItuAsn1EtcCarrierElem #----------------------------------------------------------------------------------------- ------------------------------------------------------------------------------------------ --------------------------------------------- 223 1 1 207 0 1 253 0 1
Cisco PGW 2200, F-5 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix F Sample LAN Configurations Sample Configuration for Cisco Catalyst 5500 A #standby ports set standbyports enable ! #module 1 : 2-port 10/100BaseTX Supervisor set module name 1 set vlan 1 1/1-2 set port channel 1/1-2 off set port enable 1/1-2 set port level 1/1-2 normal set port speed 1/1-2 100 set port duplex 1/1-2 full set port trap 1/1-2 disable set port name 1/1-2 set port security 1/1-2 disable set port broadcast 1/1-2 100% set port membership 1/1-2 static set port protocol 1/1-2 ip on set port protocol 1/1-2 ipx au
Cisco PGW 2200, 5-30 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 5 Migrating to Solaris 10 and Cisco PGW 2200 Softswitch Software Release 9.8 Falling Back to Solaris 8 and Cisco PGW 2200 Softswitch Release 9.5 or 9.6 5.8 Note “5.8” indicates that the system is running the Solaris 8 operating system. b. Start the MML command interface and use the following command to see if the software starts properly. mml> rtrv-ne Step 4 Verify that the correct version of the Cisco PGW 2200 Softswitch software is running. Step 5 Log in again as root and start vxdiskadm. # vxdiskadm Text similar to the following is displayed: Volume Manager Su
2-46 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 2 Installing the Sun Solaris 10 Operating System Loading the Sun Solaris 10 Operating System Modifying /etc/opt/SUNWexplo/srscinput.txt Modifying /etc/opt/SUNWexplo/t3input.txt [ verifying class <build> ] ## Executing postinstall script. Installation
Cisco PGW 2200, A-46 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix A XECfgParm.dat File Parameters Understanding the XECfgParm.dat File Format SIP.dns_query_timer (Added in Release 9.8(1)) The amount of time in seconds before a Cisco PGW 2200 Softswitch DNS NAPTR query times out. Valid values: 1–30 Default: 5 Note Do not add this property to the Xecfgparm.dat file unless you need to modify the default value. If the parameter is not present in the Xecfgparm.dat file, the Cisco PGW 2200 Softswitch uses the default value. We r
Cisco PGW 2200, D-38 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix D Sample Installation Scripts Sample Configured XECfgParm.dat Files for Cisco PGW 2200 Softswitch Release 9.6(1) *.transpathId = 01 # Transpath Id for ASN *.ownTranspathId = 01 *.peerTranspathId = 02 *.MGC_CDR_NODE_ID = BUTTERFLY-HENDRIX-NODE # System Id for CDR *.desiredPlatformState = master *.virtualFaultTolerant = false # avoid prov-dply/sync on FT mode in egw *.SysConnectDataAccess = true # true, establish conn. to Data Access Subsystem *.GWClearCh
Cisco PGW 2200, 4-59 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Chapter 4 Configuring the Cisco PGW 2200 Softswitch Software Configuring SCP Queries #----------------------------------------------------------------------------------------- ----------------------------------- # MS 22: INAP Prepaid Services ApplyChargingReport (Final End) #----------------------------------------------------------------------------------------- ----------------------------------- 1 0 3 0 0 3 13 0 0 0 0 0 0
Cisco PGW 2200, A-30 Cisco PGW 2200 Softswitch Release 9.8 Software Installation and Configuration Guide OL-18083-14 Appendix A XECfgParm.dat File Parameters Understanding the XECfgParm.dat File Format engine.CircuitReservation Enables or disables the circuit reservation feature. Values: True, False Default: False engine.CMMdlFile Location of call processing libraries. Default: ../lib/cc Note Do not change this value. engine.FaultRecoveryAuditTimer Specifies the time interval between consecutive background audit procedures. The FaultRecoveryA
Cisco ME 6500 Switch Installation manual
ME 6500 |
Cisco 2950 - Catalyst Switch Switch Getting started manual
2950 - Catalyst Switch |
Cisco 2960-48TC - Catalyst Switch Switch Datasheet
2960-48TC - Catalyst Switch |
Cisco DS-C9216I-K9 Switch Configuration manual
DS-C9216I-K9 |
Cisco Nexus 7000 Series Switch Hardware installation and reference manual
Nexus 7000 Series |
Cisco 1841 - 1841 Integrated Services Router Switch Hardware installation manual
1841 - 1841 Integrated Services Router |
Cisco CATALYST RPS 2300 Switch Installation notes
CATALYST RPS 2300 |
Cisco Linksys SFE1000P Switch Reference manual
Linksys SFE1000P |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Easypix | LCD | Operation & user’s manual | easypix/lcd-Y1O.pdf | 22 Sep 2023 | 64 | 2.24 Mb |
2 | VTech | InnoTab Software - Dora The Explorer | Operation & user’s manual | vtech/innotab-software-dora-the-explorer-9UC.pdf | 20 Jun 2023 | 10 | 2.95 Mb |
3 | Craftsman | 351.221160 | Operator's manual | craftsman/351-221160-6XR.pdf | 12 Apr 2024 | 44 | 4.68 Mb |
4 | Samsung | SCP-2370RH | Specifications | samsung/scp-2370rh-ZBQ.pdf | 01 Mar 2024 | 2 | 1.65 Mb |
5 | HP | VL600 - Vectra - 128 MB RAM | Installation manual | hp/vl600-vectra-128-mb-ram-74F.pdf | 23 Oct 2023 | 27 | |
6 | Lorex | LNC104 | Features & specifications | lorex/lnc104-U2H.pdf | 25 Nov 2022 | 3 |
Belkin
PoP74080em F5U209Hi-Speed USB 2.0 External Drive Enclosure User ManualManuel d’utilisation du boîtierexterne USB 2.0 High Speed Benutzerhandbuch für externes Laufwerkgehäuse für USB 2.0 Hi-SpeedGebruikershandleiding voor houder voor extern Hi-Speed USB 2.0-stationAlojamiento de unidad externa USB 2.0 de alta velocidad Manual del usuarioHi-Speed USB 2.0 …
F5U209(141 pages) |
Connect-Tek
KEYPORT MILLENNIA USB Series Models: USB-2, USB-4 User Manual Connect-Tek, Inc. 39-20 24th Street Long Island City N.Y. 11101 Phone: (718) 729-3700 Fax: (718) 729-3972 www.connect-tek.com
…
USB-2(16 pages) |
ABB
— Automatic transfer switches34OX_30-1600 rev. B / 1SCC303011M0201INSTALLATION AND OPERATING INSTRUCTIONAutomatic transfer switchesTruONE® ATS, OX_ 30. . .1600_
…
TruONE ATS(160 pages) |
Lutron Electronics
WiringA. Single Line Wiring2 Connect sensing switchWARNING! Shock Hazard. May result in serious injury or death. Turn power OFF at circuit breakers before installing the unit.1Turn power OFFIIIOOO®Dual Circuit Dual Technology Sensing Switch Installation GuideLighting120-277 V~ 50 / 60 Hz 6 AFan120 V~ 50 / 60 Hz 4.4 A 1/6 HPCombined lighting and fan loa …
Maestro MS-B202(2 pages) |
H3C
H3C S5150-EI Switch Series Troubleshooting Guide Document version: 6W101-20171222 Copyright © 2017 New H3C Technologies Co., Ltd. All rights reserved. No part of this manual may be reproduced or transmitted in any form or by any means without prior written consent of New H3C Technologies Co., Ltd. The informat …
S5150-EI Series(36 pages) |
Dell
www.dell.com | support.dell.comDell™ SystemsInstalling a Riser BoardInstallation d'une carte de montage (carte riser)Installation eines Riser-BoardsInstalación de la tarjeta de ampliación� …
PowerEdge 1650(44 pages) |
A&D Blood Pressure Monitor UA-767#AP364A UA-767: A&D Blood Pressure Monitor Owner Documentation UA-767, 1 |
Dell Laptop TrueMobile 1300Laptop Owner's manual (Dell TrueMobile 1300) TrueMobile 1300, 142 |
Allied Telesis Network Router AT FS708LE AT-FS708LE AT-FS708LEAllied Telesis Network Router AT FS708LE AT-FS708LE AT-FS708LE Installation manual AT FS708LE AT-FS708LE AT-FS708LE, 51 |
Aastra Telephone Clearspan 6731i#V61J25 Clearspan 6731i: Aastra Telephone Owner Documentation Clearspan 6731i, 8 |
Canon Printer MX720 Series#3T7Y68 MX720 Series: Canon Printer Owner Documentation MX720 Series, 189 |
Jacuzzi Hot Tub Shower Base Bonaire 4848Hot Tub Specifications (Jacuzzi Shower Base Bonaire 4848) Shower Base Bonaire 4848, 2 |
Unold Bread Maker 68511 BACKMEISTER EXTRAUser Guide: Unold 68511 BACKMEISTER EXTRA (53Z4Z2, Upd.Thursday 23-11-2023) 68511 BACKMEISTER EXTRA, 134 |
Ford Automobile 2006 Escape J87R#C85QF5 2006 Escape J87R: Ford Automobile Owner Documentation 2006 Escape J87R, 90 |
Mackie Amplifier SP1200Amplifier PDF Instruction manual SP1200, 28 |
Radio Shack Speakers 3 1/2-Inch Super Horn TweeterRadio Shack 3 1/2-Inch Super Horn Tweeter User Manual (Owner's manual), @217824 3 1/2-Inch Super Horn Tweeter, 2 |
Teac Stereo System GF-330Stereo System #TAR854 GF-330, 18 |
GEAppliances Water Heater GEH50DNSRSAWater Heater Owner's manual & installation instructions (GEAppliances GEH50DNSRSA) GEH50DNSRSA, 68 |