Manualios.com

Save Enairgy Heat Pump / Air Conditioner Installation And User

  • Heat Pump / Air Conditioner Air Conditioner
  • max7/dXz0QJtY
  • Installation And User
  • PDF / Adobe Acrobat Reader
  • 25

Save Enairgy Heat Pump / Air Conditioner Manual Online:

3.1, 1682 votes
Save Enairgy Heat Pump / Air Conditioner User Manual
Save Enairgy Heat Pump / Air Conditioner User Guide
Save Enairgy Heat Pump / Air Conditioner Online Manual

Text of Save Enairgy Heat Pump / Air Conditioner User Guide:

  • Save Enairgy Heat Pump / Air Conditioner, Heat Pump / Air Conditioner INSTALLATION AND USER MANUAL BEFORE INSTALLING AND USING THIS AIR CONDITIONER PLEASE READ ALL INSTRUCTIONS CAREFULLY. Version 20110711.BL With supplemental heat – 208v/230v

  • Save Enairgy Heat Pump / Air Conditioner, 1.3 RECEIVING THE GOODS The air conditioner is delivered in protective packaging and is accompanied by an instruction manual. When the air conditioner is unpacked, please check that the air conditioner and accessory package are complete and undamaged. 1.4 HANDLING Be fully aware of the weight of the air conditioner before attempting to lift it Take all necessary precautions to avoid damaging the product or causing personal injury It is advisable to remove the packaging only when the air conditioner has been located in the point of installation Carefully remove the ad

  • Save Enairgy Heat Pump / Air Conditioner, 1.1 INTRODUCTION 1 1.2 IMPORTANT SAFETY INSTRUCTIONS 1 1.3 RECEIVING THE GOODS 2 1.4 HANDLING 2 1.5 LIST OF ACCESSORIES 2 1.6 TECHNICAL FEATURES 3 2.1 POSITIONING THE AIR CONDITIONER 4 2.2 PAPER TEMPLATE 4 2.3 DRILLING THE WALL 6 2.4 MOISTURE PROTECTING WALL 7 2.5 FASTENING THE BRACKET 7 2.6 FITTING THE GRATINGS 8 2.7 CONNECTING DRAIN PIPE 9 2.8 FITTING THE AIR CONDITIONER ON THE BRACKET 10 2.9 POWER CORD CONNECTION 11 3.1 INTRODUCTION OF LCD ICONS 12 3.2 REMOTE CONTROL FUNCTIONS 12 3.3 HEATING MODE 13

  • Save Enairgy Heat Pump / Air Conditioner, 3.15 PROBLEM SOLVING POSSIBLE CAUSE -The air conditioner does not work. -The air conditioner does not cool the room. -Strange smells in the room. Water dripping from the air conditioner. -The remote control does not work. -The air conditioner does not work 3 minutes after being switched on. POSSIBLE SOLUTIONS 1. Wrong setting of the timer/Check it. 2. Problem with the power supply connection/Call the service center. 3. The filter could be dirty/Clean it. 4. The required temperature or mode is not properly set/Check it. 5. The air supply or dischar

  • Save Enairgy Heat Pump / Air Conditioner, 3.12 FRONT PANEL FUNCTION (P33 ) When the unit starts working, the front panel and flap opens completely. 15 seconds later, the indoor fan and compressor work according to mode setting. The front panel stays open while the unit is working. If the unit is turned off, the indoor fan stops first, then the front panel and the flap close completely. 3.13 INSTALLING AND CHANGING THE BATTERIES (P34) On the back of the remote control handset, open the battery cover, hold the hook and lightly pull up.

  • Save Enairgy Heat Pump / Air Conditioner, 2.4 MOISTURE PROTECTING WALL EMPTY WALL PROTECTION (P10, 11, 12) If the wall is built with empty brick as shown in P10 below. It is necessary to use insulating film with tar or bitumen as shown in P11. This film is flexible and waterproof. It must be positioned inside the wall, with round shape and the length must be less than the wall thickness. Usually the thickness of this tar or bitumen film is .078 inches. SOLID WALL PROTECTION (P13, 14) If the wall is built of full brick or stone, for this kind of solid wall, it is recomm

  • Save Enairgy Heat Pump / Air Conditioner, 2.6 FITTING THE GRATINGS After drilling the holes, the plastic gratings supplied with air conditioner need to be fitted on the wall. 1. When gratings have easy accessibility, you may fix the gratings from outside. It is recommended to fasten them to the wall with wall plugs and screws with a diameter of .24 inches, keeping the fins in vertical position. (See image P16) 2. When the air conditioner is installed in a tall building, and it is impossible to reach the gratings from outdoors, you may fix the gratings from inside. Put silicon gel around the soft grating, as shown in P17. Then fold the outer grating in half, insert your arm inside the hole with the grating.

  • Save Enairgy Heat Pump / Air Conditioner, 1.1 1.1 INTRODUCTION Please note: Do not dispose of any packaging until the installation of the air conditioner is completed. After having removed the packing, check that all the content is intact and complete. (See list of accessories). In the event of missing parts, contact your retailer. This air conditioner has been designed to cool, dehumidify or heat the air of a room and should only be used for this purpose. The manufacturer cannot be held liable for damage caused to property or injury to persons or ani

  • Save Enairgy Heat Pump / Air Conditioner, 2.3 DRILLING THE WALL (P6, 7, 8, 9) Please note: If you are drilling the hole above ground floor level, please ensure that the area has been secured and while the holes are drilled the outside area is supervised until drilling has been completed. INTAKE AND OUTLET HOLES (P6) This operation should be carried out using the proper tools (diamond tip or core borers drills with high twisting torque and adjustable rotation speed). Find the holes center drilled before, use a core boring head having a diameter of 7.9 inches to drill the two holes for intake and outlet air. It is recommended that the holes must have a slightly downward inclin

  • 1.6 TECHNICAL FEATURE (P1, P2) Model iWARM 2.3 Cooling capacity* (BTU/h) 7800 Heating capacity* (BTU/h) 6900 Heater* BTU 1500 Rated voltage (V) 208-230 Absorbed power in cooling* (W) 973 Absorbed current in cooling* (A) 4.35 Absorbed power in heating* (W) 900 Absorbed current in heating* (A)

  • Save Enairgy Heat Pump / Air Conditioner, The black silicon gel is just for reference, white or transparent color gel may also be used to fix the outdoor grille.(P22) The above installation solution is for solid walls. PIPES THROUGH THE WALL (OPTIONAL)(P23) After fixing the outdoor grille with above solution, plastic pipes may be fixed inside the hole as an alternative installation method to section 2.4. Pipe outer diameter is 7.8 inches with length determined by the wall thickness. 2.7 CONNECTING DRAINAGE PIPE Connect the drain pipe to the back side of the air conditioner after unplugging the black rubber cup (see P24). With this solution, you can drain the condensate to a suitable place. 1. Con

  • Save Enairgy Heat Pump / Air Conditioner, 3.14 MAINTENANCE (P35, 36, 37) FILTERS CLEANING: The filter should be cleaned regularly to keep the air conditioner running efficiently. Clean the filter every two weeks. How to proceed: -- Disconnect the air conditioner from the electrical supply. -- Open the front panel by hand. -- Go to the filter holder (See P35), and remove the filter grating from the slot. (See P36). -- Proceed to wash the filter (not with hot water) and only when they are dried replace them in the same way. (See P37) ATTENTION: Do not use the air conditioner without f

  • Save Enairgy Heat Pump / Air Conditioner, 2.1 POSITIONING THE AIR CONDITIONER (P3) To maintain the best performance from your air conditioner, prevent breakdowns or hazards, you must position it correctly. Please follow the guidelines and instruction below. The air conditioner must be installed on an interior wall that has access to the outside with a minimum of 2 meters clearance. (See image P3) The air conditioner must be fitted leaving space around it as illustrated in the paper template. The wall on which the air conditioner is installed must be sturdy and able to withstand the weight of the air conditioner. After determining the best place for installation as described above, please chec

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony 3-287-969-15 (1) Instruction manual sony/3-287-969-15-1-GH7.pdf 29 Oct 2023 167 4.49 Mb
2 Iomega REV 70GB Product release information iomega/rev-70gb-SIB.pdf 14 Jan 2023 1
3 YURAKU YUR.BEAT DUO Instruction manual yuraku/yur-beat-duo-7Q9.pdf 12 Jul 2022 21 0.3 Mb
4 ProForm 831.29675.0 Operation & user’s manual proform/831-29675-0-I69.pdf 04 Jan 2023 30
5 AUSTRALIAN MONITOR AMIS HE2 Introduction australian-monitor/amis-he2-J28.pdf 04 Jan 2024 2 0.4 Mb
6 Directed Electronics 3200HS Owner's manual directed-electronics/3200hs-1K3.pdf 04 Aug 2022 19 0.36 Mb

Similar Resources:

  • Heat Controller

    VMC09SB-1 Service

    (19 pages)
    Wall MountedMini - Split SystemInverter Single-ZoneVMC09SB-1 VMC12SB-1VMC18SB-1VMC24SB-1Air ConditioningImportant Information• Please read carefully and thoroughly this manual before operating this unit.• Contact a qualified sevice technician for installation, repair and maintenance of this unit.• The appliance is not intended for use by young children …
  • Mitsubishi Electric

    PKH-2FKA

    (86 pages)
    TECHNICAL & SERVICE MANUALSPLIT-TYPE, HEAT PUMP AIR CONDITIONERSCONTENTS1. TECHNICAL CHANGES·······················22. PART NAMES AND FUNCTIONS········33. SPECIFICATIONS·································54. DATA········································· …
  • Waeco

    CDF-45

    (18 pages)
    CDF-18, CDF-25, CDF-35, CDF-45CDF-18CDF-25CDF-35CDF-45DE 5 Kompressor-KühlboxBedienungsanleitungEN 19 Compressor CoolerInstruction ManualFR 33 Glacière à compressionManuel d’utilisationES 48 Nevera por compresorInstrucciones de usoIT 63 Frigorifero a compressoreIstruzioni per l’usoNL 78 CompressorkoelboxGebruiksaanwijzingDA 91 Kompressor-køleboksBetj …
  • Dometic

    FreshJet 1100

    (46 pages)
    DachklimaanlageBedienungsanleitung . . . . . . . . . . . . 16Air conditioning roof unitOperating manual . . . . . . . . . . . . . . 48Climatiseur de toitNotice d’utilisation . . . . . . . . . . . . . . 78Aire acondicionado de techoInstrucciones de uso . . . . . . . . . . . 109Climatizzatore a tettoIstruzioni per l’uso . . . . . . . . . . . . . 141Aircon …
  • Impecca

    ISMI-C15

    (47 pages)
    Flex Series R410A GMV Multi VFR System-Indoor Unit (For North America) Compact Panel Cassette Type Indoor UnitThank you for choosing Air Conditioners, please read this owner’s manual carefully before operation and retain it for future reference. If you have lost the Owner’s Manual, please contact the local agent orvisit www.Impecca.com for an elec …
  • Mitsubishi Electric

    Mr.Slim MSZ09UN W

    (77 pages)
    SERVICE MANUALCONTENTS1. FEATURES·························································22. PART NAMES AND FUNCTIONS······················43. SPECIFICATION·················································64. DATA········· …

Comments, Questions and Opinions: