Manualios.com

Clarion MS3001 Installation Manual

Clarion MS3001 Manual Online:

3.35, 562 votes
Clarion MS3001 User Manual
Clarion MS3001 User Guide
Clarion MS3001 Online Manual

Text of Clarion MS3001 User Guide:

  • Clarion MS3001, 1. Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 1 2. Installation Tips . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 2 3. Mounting Components Main Unit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3 Siren (MS3001) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Page 3 Battery Back-up Siren (MS3200) . . . . . . . . . . . . . . .

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 1 1. Be sure to read the manual thoroughly before beginning the installation to ensure a proper understanding of the MS3001 / MS3200 and its functions. 2. Verify system contents: ❑ Main Unit ❑ Two 3-Button Remote Transmitters ❑ Siren (MS3001 only) ❑ Battery Backup Siren (MS3200 only) ❑ Harnesses • 14-Pin main harness • 4-Pin auxiliary function harness • 2-Pin Status LED harness • 2-Pin Override Switch harness • Pre-wired starter kill relay socket with relay 3. Discuss the location of the status LED and the Emergency Override Switch with the vehicle’s owner. 4. Discuss the optional features of the M

  • Clarion MS3001, Page 2 - MS3001 / MS3200 Installation Manual 1. Use a Volt / Ohm meter to test all wires. Do not use a test light. 2. Good power and ground connections are essential for proper operation. 3. Route all wires from the engine compartment to the interior of the vehicle through a grommet and use electrical tape and split loom tubing for protection. 4. When adding optional accessories such as door locks, window modules, etc., be sure to fuse each additional accessory power lead separately from the main power

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 3 Main Unit The main unit should be mounted in the interior of the vehicle. Do not mount the main unit in the engine compartment. For maximum security, avoid mounting the main unit where it will be easily accessible to a thief. If you are mounting the unit under the dash board, be sure to mount the unit as high as possible and in a location where it will not interfere with the operation of the pedals. Be sure to extend the antenna as high as possible so that optimum range can be achieved. Before securing the unit, be sure that you have made all of the necessary jumper selections and pe

  • Clarion MS3001, Page 4 - MS3001 / MS3200 Installation Manual For maximum security, it is best to disguise all under hood system wires with factory style split loom tubing so that they cannot be easily identified by a thief. Run all wires from the engine compartment into the interior of the vehicle through a grommet. When testing the system, be sure to turn the siren key switch to the “on” position. EXT2 Extended Range Antenna (optional) The optional EXT2 is a tuned, coaxial antenna, designed to be used with the MS3001 / MS3200 security system to increase transmitter range. When properly installed, the EXT2 will add greater installation flexibilit

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 5 +12v +12v Chassis Ground +12v LED Override Switch Black Red White Yellow White/brown Orange +12v (MS3200 only) Yellow/white Red/yellow Parking Lights Relay Dome Light Relay Horn Relay 10A Negative Door Pinswitch Positive Door Pinswitch Dome Light Dome Light Negative Hood/ Trunk Switch (+) or (-) output Siren (+) output Aux 1(-) output Yellow/black Relay Aux 2 (-) output White/blue (-)unlock White/green (-)lock Door Lock Relays Siren Violet Blue/red Ignition +12v Starter Defeat N/O (-) output Blue Starter Defeat N/C (-) o

  • Clarion MS3001, Page 6 - MS3001 / MS3200 Installation Manual 14-Pin Main Harness Pin 1 - BLACK: Ground. Connect to a solid chassis ground. Be sure to use a ring connector of proper size. Scrape away the paint at the grounding point. Pin 2 - RED: Main Power (+12v) input [3A fuse]. Connect to constant +12v. A clean source of power is essential. This connection can be made at either the battery or at the constant power supply wire to the ignition switch. Be sure to install a fuse near the connection. Do not remove or bypass the fuse holder included on the wire harness. Pin 3 - VIOLET: Ignition input (+12v) input. Connect to a source that maintains +12v when the

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 7 In this configuration, the vehicle’s starter will be disabled only when the system is armed and alarming. If power to the system is lost or the system becomes disconnected, the vehicle will be able to start. Pin 12 - BLUE/red: Starter Defeat Normally Open (-) output. Provides a negative output while the system is Disarmed to enable the starter circuits. Connect to the provided Starter Kill Relay socket as shown. In this configuration, the vehicle will only start when the system is both connected and disarmed. Pin 13 -

  • Clarion MS3001, Page 8 - MS3001 / MS3200 Installation Manual 4-Pin Auxiliary Function Harness Pin 1 - YELLOW/black: Auxiliary Function 2 (-) output. Provides a negative output to activate a relay. The output of this wire can be set to operate in one of two operating modes. See Jumper Settings . Momentary - provides output for as long as the transmitter button is pressed. Latched - provides an output that stays active until the transmitter button is pressed again. Possible uses of the latched output include: audio system valet, auxiliary lighting control, headlight operation,

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 9 Jumper Selections Parking Light Polarity. Selects the polarity (+/-) for the output of the on-board Parking Light relay. Pin 1 + Pin 2 = positive Pin 2 + Pin 3 = negative Auto Rearm. When the jumper is off the system will automatically rearm if no other activity is detected within one minute of Remote Disarming. One minute after Remote Disarming, the system will alert you with a 10 second series of chirps, then arm. (If the Passive Door Locking feature is selected during the installation, the system will also relock the doors.) Any of the following will cancel Automatic System Rearming: • Turn on the ignition. • Open the Trunk

  • Page 10 - MS3001 / MS3200 Installation Manual Accessing the Jumpers Using a flathead screwdriver, carefully press in on the access tabs on the sides of the case until the hooks release. Take care not to push the tabs in too far or they may break. Once you have made your selections, close the case by aligning the top and button halves of the case, making sure that the tab

  • MS3001 / MS3200 Installation Manual - Page 11 Remote Transmitter Layout Each system comes with 2 Remote Transmitters, pre-programmed to Arm and Disarm the system with chirp confirmation using Button 1 . Button 1 Arms and Disarms the system. This Button also locks and unlocks the doors when the system is in Valet Mode. Button 2 controls the system’s Auxiliary Function 1. When

  • Clarion MS3001, Page 12 - MS3001 / MS3200 Installation Manual Two Car Operation For your convenience, you may use a single transmitter to operate multiple vehicles. The Transmitter can be set to arm Car #1 with Button 1 and arm additional cars with the first available Buttons not being used by Car #1. The following diagram illustrates how a single transmitter can operate a two-car system. As stated, the Programming and set-up functions of Car #2’s system will not be affected by this Transmitter configuration and will operate exactly as described in this manual. The following diagram describes how it is possible to cont

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 13 Adding a New Transmitter into the System 1. Turn on the ignition. 2. Press and hold the Override switch. • The status LED will turn on red. 3. Within 5 seconds: Continue holding the Override switch and Press Transmitter Button 1* For remote arming with chirp confirmation. --- or --- Release the Override switch and Press Transmitter Button 1* For remote arming without chirp confirmation. • The status LED will flash once quickly to confirm that the new Remote Transmitter has been added. 4. Turn off the ignition. Deleting Transmitters (Adding a Remote Transmitter and Erasing All Other Remote Transmitters From the Syste

  • Clarion MS3001, Page 14 - MS3001 / MS3200 Installation Manual Arming Mode Selection (Passive or Active Arming) Using the Remote Transmitter, you may select Passive Arming with chirp confirmation, Passive Arming without chirp confirmation, or Active Arming (Remote only). To set the Arming Mode: 1. Turn the ignition on. 2. Within 4 seconds, press Transmitter Buttons 1 and 2 together. First push: one chirp = Passive Arming with chirp Second push: two chirps = Active Arming Third push: three chirps = Passive without chirp 3. Turn off the ignition key to save your selection. Ignition

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 15 Valet Mode Allows you to temporarily disable the security system when the car is being serviced or turned over to a parking attendant. To turn Valet Mode on or off: 1. Turn on the ignition. 2. Press and hold the override switch. 3. While holding the override switch, turn off the ignition. • The siren will chirp once to indicate you have turned Valet Mode on. • The siren will chirp twice to indicate you have turned Valet Mode off. 4. Release the override switch. While Valet Mode is on, you can continue to lock and unlock

  • Page 16 - MS3001 / MS3200 Installation Manual The MS3001 / MS3200’s dual stage, on-board Shock Sensor is adjusted entirely through the use of the Remote Transmitter. Trigger Sensitivity The Trigger sensitivity is adjustable to 8 levels, including an “off” setting where the sensor is ignored. To Adjust the Trigger sensitivity: 1. Turn the ignition key

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 17 You can use this chart to quickly identify and interpret the MS3001 / MS3200 system’s chirp indications and LED flashes. The system continuously monitors all protected zones, even when it is not armed, and warns you if it detects a problem when you turn off the ignition. 1. Turn off the ignition. 2. If the siren chirps twice, the system has detected a problem. 3. The status LED will flash to indicate the zone where the problem has been detected. 1 flash = door 2 flashes = Shock Sensor 3 flashes = optional senso

  • Clarion MS3001, Page 18 - MS3001 / MS3200 Installation Manual Dome Light Control Relay Diagrams The Auxiliary Function 2 Output can be set for momentarty or latched operation allowing custom operation of vehicle systems such as: Remote Control of Audio System (Latched Operating Mode) This enables the user to listen to the vehicle’s audio or video system for extended periods without need of the vehicle’s ignition key. When the Aux 2 function is pressed, the radio will turn on until the Aux 2 function is pressed again

  • MS3001 / MS3200 Installation Manual - Page 19 Door Lock Diagrams Negative Trigger Positive Trigger Voltage Reversal Aftermarket Actuators Vacuum Lock System White/green = (-) Lock White/blue = (-) Unlock install_MS3001.qxd 8/11/99 4:15 PM Page 19

  • Clarion MS3001, Page 20 - MS3001 / MS3200 Installation Manual The optional DLRM is a factory door lock integration module with built-in relays for use with high current positive trigger door locking systems (like those found on some older GM models) and voltage reversal door locking systems (also known as 5-wire systems, found on many Ford vehicles and some GM models). The DLRM can also be used with aftermarket actuators for vehicles not equipped with power door locks. Some late model Chrysler, Ford, and Mazda vehicles use lower voltage sys

  • Clarion MS3001, MS3001 / MS3200 Installation Manual - Page 21 Be sure to add a fuse to the violet wire of the 5-pin harness and connect to a constant source of power separate from the alarm’s power wire. DO NOT connect the DLRM Violet wire to alarm’s main power lead. High Current Positive Trigger System Voltage Reversal System Adding Aftermarket Actuators DLRM Wiring Diagrams install_MS3001.qxd 8/11/99 4:15 PM Page 21

  • Clarion MS3001, +12v +12v Chassis Ground +12v LED Override Switch Black Red White Yellow White/brown Orange +12v (MS3200 only) Yellow/white Red/yellow Parking Lights Relay Dome Light Relay Horn Relay 10A Negative Door Pinswitch Positive Door Pinswitch Dome Light Dome Light Negative Hood/ Trunk Switch (+) or (-) output Siren (+) output Aux 1(-) output Yellow/black Relay Aux 2 (-) output White/blue (-)unlock White/green (-)lock Door Lock Relays Siren Violet Blue/red Ignition +12v Starter Defeat N/O (-) output Blue Starter Defeat N/

More Instructions:

DOWNLOAD

Related Products and Documents (Car Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Weider WESY26331 Operation & user’s manual weider/wesy26331-4RA.pdf 21 Dec 2022 32 1.48 Mb
2 Weiser Smartcode 10 Programming and troubleshooting manual weiser/smartcode-10-XSP.pdf 04 Nov 2023 15
3 Fieldpiece SRS2C Operator's manual fieldpiece/srs2c-9L1.pdf 22 Apr 2023 2
4 NAD C300 Specification sheet nad/c300-7LD.pdf 07 Aug 2023 2
5 Makita TW100D Instruction manual makita/tw100d-IG3.pdf 15 Jul 2023 8
6 Vega VEGAFLEX 62 Product information vega/vegaflex-62-4NL.pdf 25 Nov 2022 15

Similar Resources:

  • Sanji

    AT 70

    (4 pages)
    USER INSTRUCTIONS At70 At70 At70 PG1The AT 70 is a new generation alarm and comfort control system, designed to enhance the security of factory fitted transponder immobiliser systems. Sanji have incorporated the most up to date technology to improve performance and long term reliability. Read these instructions for correct system operation. All point …
  • Freedom

    650

    (2 pages)
    #651-09Omega part #2-Way Keyless Entry & Security System Programmable FeaturesFreedom 650Feature # Default Arm/Lock Disarm/UnlockFeature #1 Pin Code (for overriding alarm) 1 Press options are: 2 through 12 PressesFeature #2 Last Door Arming OFF ON OFFFeature #3 Doors Lock With Last Door Arming ON ON OFFFeature #4 Auto Rearming …
  • Audiovox

    Keyless Entry Alarm Upgrade Module APS-30

    (6 pages)
    KEYLESS ENTRY ALARM UPGRADE MODULEINSTALLATION INSTRUCTIONSPRE - INSTALLATION NOTES :STAND ALONE PASSIVE ALARMWhen installing the APS-30 as a stand alone passive alarm system, the dip switches must be set as follows;Dip Switch#1=ONDip Switch#2=ONDip Switch#3=OFFDip Switch#4=OFFDip Switch#5=OFFDip Switch#6=OFFPASSIVE / ACTIVE ARMING SELECTION : DIP SWITCH # 1 …
  • Autostart

    AS-6205 SH

    (20 pages)
    Notice The manufacturer will accept no responsibility for any electrical damage resulting from improper installation of the product, be that either damage to the vehicle itself or to the Unit. This Unit must be installed by a certified technician using all safety devices supplied. Please note that this guide has been written for properly trained Autostart t …
  • Fortin

    EVO-ALL

    (5 pages)
    (+) Start Grey(~) Data Brown/Orange(+) Ignition PinkCCopyright © 2010, Fortin Auto Radio Inc(-) Parking Lights PinkOBDII(~) CAN LOW 2 Yellow(~) CAN HIGH 2 White614Front of Fuse panel Devant la Boîte à fusiblesParking Light SwitchCommutateur de Lumières de stationnementDriver Kick PanelPanneau Latéral côté chauffeurBehind Fuse panel Derrière la Bo� …
  • Clifford

    Matrix 1

    (40 pages)
    NOTE: This product is intended for installation by a professional installer only! Any attempt to install this product by any person other than a trained professional may result in severe damage to a vehicle’s electrical system and components. Matrix +1Installation Guide©2008 Directed Electronics, Vista, Ca. N3105X- 2008-12 …

Comments, Questions and Opinions: