Text of AudioCodes Media 800 MSBR User Guide:

  • Version 6.6 363 Mediant 800 MSBR User's Manual 28. Configuring Supplementary Services 28.6.4 BRI Call Forwarding The device supports call forwarding (CF) services initiated by ISDN Basic BRI phones connected to it. Upon receipt of an ISDN Facility message for call forward from the BRI phone, the device sends a SIP INVITE to the softswitch with a user-defined co

  • AudioCodes Media 800 MSBR, User's Manual 114 Document #: LTRT-12809 Mediant 800 MSBR You can configure up to 12 interfaces, consisting of up to 11 Control and Media interfaces and 1 OAMP interface. The default VoIP interface is as follows:  Application type: OAMP + Media + Control  IP address: 192.168.0.2 with prefix length 24 (i.e., subnet mask 255.255.255.0)  Default gateway: 192.168.0.1  Name: "Voice"  VLAN ID: 1 Complementing this network configuration is the On-Board Ethernet Switch configuration. This enables you to configure the VLAN IDs accessible through e

  • AudioCodes Media 800 MSBR, Version 6.6 997 Mediant 800 MSBR User's Manual 68. Technical Specifications Function Specification  Static and dynamic routing (RIP1, RIP2, OSPF, BGP) Control and Management Control Protocols SIP-TCP, SIP-UDP, SIP-TLS and SIP-MSCML* Cloud Resilience Package (CRP) and Standalone Survivability (SAS) for service continuity Operations & Management  AudioCodes' Element Management System (EMS)  Embedded HTTP Web Server, SNMP V2/V3  Telnet, SSH, TR-069  Remote configuration and software

  • AudioCodes Media 800 MSBR, Version 6.6 465 Mediant 800 MSBR User's Manual 31. SBC Configuration Parameter Description CLI: src-ip-address [Classification_SrcAdd ress] incoming SIP dialog. Notes:  If this parameter is not configured or is configured as an asterisk (*), then any source IP address is accepted.  The IP address can include the "x" wildcard to represent single digits. For example: 10.8.8.xx represents all the addresses between 10.8.8.10 to 10.8.8.99.  The IP address can include the asterisk (*) wildcard to represent any number between 0 and 255. For example, 10.8.8.* represents all addresses between 10.8.8.0 and 10.8.8.255. Source

  • AudioCodes Media 800 MSBR, User's Manual 918 Document #: LTRT-12809 Mediant 800 MSBR Parameter Description d] message is received.  [0] = (Default) Connect message isn't sent after SIP 183 Session Progress message is received.  [1] = Connect message is sent after SIP 183 Session Progress message is received. Web: Local ISDN Ringback Tone Source EMS: Local ISDN RB Source CLI: local-isdn-rbt-src [LocalISDNRBSource_ x] Determines whether the ringback tone is played to the ISDN by the PBX/PSTN or by the device, per trunk.  [0] PBX = (Default) PBX/PSTN.  [1] Gateway = The device plays the ringback tone. Notes:  This parameter is applicable to ISDN protoco

  • AudioCodes Media 800 MSBR, User's Manual 766 Document #: LTRT-12809 Mediant 800 MSBR Parameter Description Disconnect CLI: idle-timeout [TelnetServerIdleDisconn ect] The valid range is any value. The default is 0. Note: For this parameter to take effect, a device reset is required. 66.2.4 SNMP Parameters The SNMP parameters are described in the table below. SNMP Parameters Parameter Description Web: Enable SNMP CLI: disable [DisableSNMP] Enables SNMP.  [0] Enable = (Default) SNMP is enabled.  [1] Disable = SNMP is disabled and no traps are sent. CLI: port [SNMPPort] Defines the device's local (LAN) UDP port used for SNMP Get/Set comm

  • AudioCodes Media 800 MSBR, Version 6.6 559 Mediant 800 MSBR User's Manual 42. QoS 42.5 Configuring 802.1p Settings The IEEE 802.1p priority marking method is a standard for prioritizing network traffic at the data link/Mac sub-layer. 802.1p traffic is simply classified and sent to the destination, with no bandwidth reservations established. The 802.1p header includes a 3-bit prioritization field, which allows packets to be grouped into eight levels of priority (0-7), where level 7 is the highest. In addition, the device maps these eight levels to priority queues, where Queue 0 has the lowest priority. The device&apo

  • AudioCodes Media 800 MSBR, User's Manual 378 Document #: LTRT-12809 Mediant 800 MSBR when the operating system detects a network connection change, each Lync 2010 client submits a request to the LIS for a location. If the LIS is able to resolve a location address for the client request, it returns the address in a location response. Each client then caches this information. When the Lync 2010 client dials 9-1-1, this location information is then included as part of the emergency call and used by the Emergency Services provider to route the call to the correct PSAP. The gathering of location information in the Lyn

  • AudioCodes Media 800 MSBR, User's Manual 996 Document #: LTRT-12809 Mediant 800 MSBR Function Specification Independent dynamic vocoder selection per channel Echo Cancellation G.165 and G.168-2002, with 32, 64 or 128 msec tail length Quality Enhancement Dynamic programmable jitter buffer, VAD, CNG DTMF/MF Tones Packet-side or PSTN-side detection and generation, RFC 2833 compliant DTMF relay and Call Progress tones Detection and Generation IP Transport VoIP (RTP/RTCP) per IETF RFC 3550 and 3551, IPv6 Fax Transport T.38 compliant (real time fax), Automatic bypass to PCM Signaling Digital PSTN Protocols  E1/T1:  PRI: ETSI/Euro ISDN, AN

  • AudioCodes Media 800 MSBR, User's Manual 756 Document #: LTRT-12809 Mediant 800 MSBR 66.1.2 Routing Parameters The IP network routing parameters are described in the table below. IP Network Routing Parameters Parameter Description Static IP Routing Table Web/EMS: IP Routing Table CLI: configure voip > static [StaticRouteTable] Defines up to 30 static VoIP IP routing rules for the device. These rules can be associated with IP interfaces defined in the Multiple Interface table (InterfaceTable parameter). The routing decision

  • AudioCodes Media 800 MSBR, Version 6.6 419 Mediant 800 MSBR User's Manual 29. Analog Gateway There is one-to-one mapping between PBX lines and FXS device ports. Each PBX line is routed to the same phone (connected to the FXS device). The call disconnects when the phone connected to the FXS device is on-hooked. 29.15.3 Message Waiting Indication for Remote Extensions The device supports the relaying of Message Waiting Indications (MWI) for remote extensions (and voice mail applications). Instead of subscribing to

  • AudioCodes Media 800 MSBR, Version 6.6 913 Mediant 800 MSBR User's Manual 66. Configuration Parameters Reference Parameter Description in the proprietary SIP header, x-isdntunnelinginfo, or a dedicated message body (application/isdn) in the SIP message and then sends the data in an ISDN message to the PSTN. If the raw data in this SIP header is suffixed with the string "ADDE", then the raw data is extracted and added as Informational Elements (IE) in the outgoing Q.931 message. The tunneling of the x-isdntunnelinginfo SIP header with IEs is converted from INVI

  • AudioCodes Media 800 MSBR, User's Manual 330 Document #: LTRT-12809 Mediant 800 MSBR Notes: • Outbound IP routing can be performed before or after number manipulation. This is configured using the RouteModeTel2IP parameter, as described below. • The Outbound IP Routing Table can also be configured using the table ini file parameter, Prefix or CLI command, configure voip > gw routing tel2ip-routing.  To configure Tel-to-IP or outbound IP routing rules: 1. Open the Outbound IP Routing Table page (Configuration tab > VoIP menu >

  • AudioCodes Media 800 MSBR, Version 6.6 689 Mediant 800 MSBR User's Manual 57. VoIP Status Figure 57-7: SAS/SBC Registered Users Page SAS/SBC Registered Users Parameters Column Name Description Address of Record An address-of-record (AOR) is a SIP or SIPS URI that points to a domain with a location service that can map the URI to another URI (Contact) where the user might be available. Contact SIP URI that can be used to contact that specific instance of the User Agent for subsequent requests. 57.8 Viewing Registration Status The Registration Status page displays whether the device as a whole, its endpoints (

  • User's Manual 978 Document #: LTRT-12809 Mediant 800 MSBR Parameter Description Note: For a detailed description of this table, see 'Configuring Classification Rules' on page 462. Condition Table Web: Condition Table CLI: configure voip > sbc routing condition-table [ConditionTable] This table parameter configures Condition rules for SIP messages

  • AudioCodes Media 800 MSBR, User's Manual 404 Document #: LTRT-12809 Mediant 800 MSBR Parameter Description Hotline Dial Tone Duration CLI: hotline-dia-ltone-duration [TargetOfChannel_HotLineTon eDuration] Defines the duration (in seconds) after which the destination phone number is automatically dialed. This is applicable only if the port has been configured for Hotline (i.e., 'Auto Dial Status' is set to Hotline). The valid value is 0 to 60. The default is 16. Note: You can configure this Hotline interval for all ports, using the globa

  • AudioCodes Media 800 MSBR, User's Manual 16 Document #: LTRT-12809 Mediant 800 MSBR 60.1.3 Identifying AudioCodes Syslog Messages using Facility Levels ...........................722 60.1.4 SNMP Alarms in Syslog Messages .......................................................................723 60.2 Configuring Syslog Settings ................................................................................. 723 60.3 Configuring Debug Recording .............................................................................. 724 60.4 Filtering Syslog Messages and Debug Recordings ...

  • AudioCodes Media 800 MSBR, User's Manual 886 Document #: LTRT-12809 Mediant 800 MSBR Parameter Description EnableIp2TelInterworking:  Disabled: The network-domain field in the Resource-Priority header is set to "0 1 0 0" (i.e., "routine") in the Precedence Level field.  Enabled: The network-domain field in the Resource-Priority header is set in the Precedence Level field according to Table 5.3.2.12-4 (Mapping of RPH r-priority Field to PRI Precedence Level Value). The domain name can be a string of up to 10 characters. The format

  • AudioCodes Media 800 MSBR, Version 6.6 471 Mediant 800 MSBR User's Manual 31. SBC Configuration IP-to-IP Routing Table Parameters Description Parameter Description Matching Characteristics Source IP Group ID [IP2IPRouting_SrcIPGro upID] CLI: src-ip-group-id Selects the IP Group from where the IP-to-IP call originated. Typically, the IP Group of an incoming SIP dialog is determined (or classified) using the ‘Classification’ table (see Configuring Classification Rules on page 462). If not used (i.e., any IP Group),

Related Products and Documents (Network Router):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Philips HC5410/15 Operation & user’s manual philips/hc541015-46U.pdf 07 Aug 2022 58
2 Intermec DX4 Installation instructions intermec/dx4-Y2W.pdf 08 Mar 2024 2
3 Craftsman 917.376260 Owner's manual craftsman/917-376260-5HQ.pdf 02 Jan 2024 10
4 Acer TravelMate 2000 Manual do utilizador acer/travelmate-2000-Y59.pdf 10 Nov 2023 80
5 Keystoker K-2 Installation instructions manual keystoker/k-2-KAY.pdf 12 Aug 2023 12
6 MSB Technology S201 Operation & user’s manual msb-technology/s201-X52.pdf 02 Oct 2022 3

Similar Resources:

  • Supermicro

    SSE-G24-TG4

    (16 pages)
    Copyright 2016, SUPERMICRO Computer, Inc. Confidential STACKING GUIDE SUPERMICRO 1/10G Switches: SSE-G24-TG4, SSE-G48-TG4, SBM-GEM-X2C+, SBM-GEM-X3S+ Version 0.5 …
  • Makita

    3620A

    (20 pages)
    Router 1 /4" MODEL 3620 MODEL 3620A Equipped with electric brake 35 mm (1-3/8"1 24,000 21 1 mm 18-5/16") 2.4 kg 15.3 Ibs) INSTRUCTION MANUAL DOUBLE I A1 'ION SPECIFICATIONS Collet chuck capacity I Main body stroke I No ';k"p"dyed I Overall length I Net weight …
  • SpectraLink

    SVP100

    (2 pages)
    [email protected] • 800 676 5465 Technical Bulletin CS-05-05 Specifications subject to change without notice. © Copyright 2005 SpectraLink Corporation. All rights reserved. SpectraLink is a registered trademark in the US and other countries. The SpectraLink logo and NetLink are trademarks of SpectraLink Corporation. INTER-TEL UPGRADE OF THE SVP S …
  • Cisco

    8540 - Catalyst Campus Switch Router Modular Expansion Base

    (10 pages)
    Installing the ControllerThis chapter describes how to install the controller.IMPORTANT SAFETY INSTRUCTIONSThis warning symbol means danger. You are in a situation that could cause bodily injury. Before you workon any equipment, be aware of the hazards involved with electrical circuitry and be familiar with standardpractices for preventing accidents. Use the …
  • iPhotonix

    7271G

    (2 pages)
    band are restricted to indoor usage only.the channels 12 & 13. Operations in the 5.15-5.25GHzPage 62600 N. Central ExpresswaySuite 950Richardson, Tx 75080 USA214-575-9300 Page 1Page 7FCC Notice -1This device complies with part 15 of the FCCRules. Operation is subject to the following twoconditions: (1) This device may not …
  • Nowsonic

    Pro-313805

    (80 pages)
    Nowsonic Stage Router Pro-313805Professional 19“ Wireless Dual Band Gigabit LAN RouterUser manualBedienungsanleitungMode d‘emploiManual de usarioPodręcznik użytkownika …

Comments, Questions and Opinions: