Unico Celsius, 34 ENGLISH 3 USE AND MAINTENANCE (user part) 3.1 WARNINGS The installation and electrical connection of the air conditioner should be carried out by specialized personnel who possess the requisites set forth by law. The installation instructions are provided in the specific manual. No structural object (furniture, curtains, plants, leaves, blinds, etc.) should ever obstruct the normal flow of air from either the internal or external gratings. Never lean or, worse yet, sit on the casing of the air conditioner as this could cause ser
Unico Celsius, 38 ENGLISH 3.3.16 Starting and stopping the operating programs After having made the settings for the operating programs, they can be used or not, as needed. Either or both of the programs can be used. In particular, each time you press the button (T11) Program activation, the situation changes as follows: Use of Program no. 1 only. Use of Program no. 2 only. Use of Programs 1 and 2. Disuse of both programs.. 3.3.17 Resetting all remote control functions Press the button (T10) to reset all the remote control settings. This will cancel all the settings of the timer and the remote control will use the default settings. Moreover, on pressing the button (T10) all the possible indications
Unico Celsius, 37 UNICO INVERTER ENGLISH 3.3.11 Checking fan speed Fan speed is checked by button (T5). Pressing this button several times will change the speed in this order: Low, Medium, High and Automatic. The higher the speed setting, the greater the output of the air conditioner but also the louder its operation. If you select Automatic mode, the microprocessor in the air conditioner adjusts the speed automatically, keeping it as high as needed to reach the temperature setting with respect to the effectiv
Unico Celsius, 24 ITALIANO 3 3.5.3 Dati tecnici Per i dati tecnici sotto elencati consultare la targa dati caratteristica applicata sul prodotto. - Tensione di alimentazione - Potenza assorbita massima - Corrente assorbita massima - Potenza refrigerante - Gas refrigerante - Grado di protezione degli involucri - Max pressione di esercizio Dimensioni (largh. x alt. x prof.) mm 902x506x229 Peso (senza imballo) kg 39 CONDIZIONE LIMITE DI FUNZIONAMENTO Temperatura ambiente interno Temperatura ambiente esterno Temperature di esercizio massime DB 35°C - WB 24°C DB 43°C - WB 32°C in raffre
Unico Celsius, 25 UNICO INVERTER ENGLISH 1 GENERAL 1.1 SYMBOLS----------------------------------------------------------------------------------------------------------------------26 1.1.1 Editorial pictograms ---------------------------------------------------------------------------------------------------------- 26 1.2.2 Safety pictograms------------------------------------------------------------------------------------------------------------- 26 1.2 GENERAL INFORMATION -------------------------------------------------------------------------------------------------- 26 1.3 WARNING ------------------------------
Unico Celsius, 36 ENGLISH 3.3.5 Cooling When used in this mode, the air conditioner dehumidifies and cools the room. Activate this mode by pressing button (T4) Run mode selector until the snowflake symbol (D3) is displayed. In this run mode, the required temperature and fan speed can be set. After having activated this run mode, the compressor will start running after 3 minutes at the most and the unit begins emitting cold air. The starting of the compressor is seen by the lighting up of the relative green LED B (fig. 22) on the control panel. 3.3.6 Dehumidification only When used in this mode, the air conditioner eliminates the humidity in the room. This
Unico Celsius, 26 ENGLISH 1 GENERAL 1.1 SYMBOLS The pictograms shown in the next chapter provide the information necessary for correct use of the appliance in a rapid and unmistakable way. 1.1.1 Editorial pictograms Service - Refers to situations in which you should inform the SERVICE department in the company: CUSTOMER TECHNICAL SERVICE. Index - Paragraphs marked with this symbol contain very important information and recommendations, particularly as regards safety. Failure to comply with them could result in: - danger of injury to the operators - loss of the warranty - refusal of liability by the manufacturer. Raised hand - Refers to actions that absolut
Unico Celsius, 32 ENGLISH - close the protection of the board (fig. 19 ref. A) - refit the front cover of the machine with the six screws - refit the two wedged-in covers (upper and lower). CAUTION: these operations should be performed with the machine already positioned on the bracket. Read the instructions carefully before completely the electric connection. 2.4 TOP/BOTTOM INSTALLATION CONFIGURATION This unit may be installed either at the bottom of the wall (adjacent to the floor) or at the top (adjacent to the ceiling). The air jet can be modified to optimize
Unico Celsius, 27 UNICO INVERTER ENGLISH THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES TO PERSONS OR PROPERTY CAUSED BY FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL. The manufacturer reserves the right to modify at any time its models without changing the fundamental characteristics described in this manual. The installation and maintenance of air-conditioners like this one may be hazardous as they contain a cooling gas under pressure as well as powered parts. Therefore, the installation, first startup and subsequent maintenance should be carried out exclusively by authorized, qualified personnel. This unit complies with European Directives 2006/95/EC, 2004/108/EC, 2002/95/EC and 2002
Unico Celsius, 35 UNICO INVERTER ENGLISH 3.3 REMOTE CONTROL The remote control is the interface between the user and the air conditioner. It is therefore particularly important to familiarize yourself with the parts of the remote control that relate to this interface. All the references indicated in the following paragraphs refer to figure 29 on page 8 (unless otherwise specified). 3.3.1 Description of the remote control Buttons (fig. 28): used to set or bring up machine functions. T1 ON/OFF (standby). T2 ECONOMY key. T3 Night well-being mode. T4 Operating mode s
Unico Celsius, 33 UNICO INVERTER ENGLISH 2.5.1 Evacuating condensate water during an emergency If there should be a malfunction in the condensation water drain system, the air conditioner stops working and signals, with flashing orange, green and red lights (the second and third LEDs from the left), the alarm status. To enable the air conditioner to work temporarily until the service personnel arrive, you can drain the water out by following these simple instructions: - remove the lower cover (fig. 23 ref. A) - remove the cap (fig. 23 ref. B) after having placed a good-sized container undern
Unico Celsius, 40 ENGLISH 3.5.3 Specifications For the technical data listed below, consult the characteristic data plate applied to the product - Power supply voltage - Maximum power absorbed - Maximum current absorbed - Coolant power - Coolant gas - Protection rating of the containers - Max working pressure Dimensions (W x H x D) mm 902x506x229 Weight (without packing) kg 39 OPERATIONAL LIMITS Internal ambient temp. Outside ambient temp. Maximum operating temperature DB 35°C - WB 24°C DB 43°C - WB 32°C in cooling mode Minimum operating temperature DB 18°C DB -10°C in cooling mode Maximum operating temperatures DB 27°C DB 24°C - WB 18°C in heating Minimum operating temperatures - DB -15
Unico Celsius, 30 ENGLISH To prevent the creation of large amounts of dust and rubble due to drilling, the core borer can be fitted with a vacuum system applied by means of suction cups to the drilling zone. Our Service Department can give you all necessary information to enable you to find these devices. To drill the holes, proceed as follows: Fasten the drilling template to the wall leaving the necessary space from the ceiling, floor and side walls as shown on the template that may be fixed using adhesive tape. Use a small drill or punch to mark, with extreme care, the exact centre of each o
Unico Celsius, 2 I STRU Z I O NI P ER I NST AL L AZ I O NE, U SO E MANUT ENZ ION E INST R UCT I O NS FO R I NST AL L ATION , U SE AND M A I NTENA NCE I NST RUC TI ONS P O U R L 'I NST A L L A T I O N , L 'EM PLO I E T L 'E NT RETIE N HAND BUCH FÜR I NST AL L A TION , G EBRA UCH U N D W A RT U NG IN ST RUC CI O N ES P ARA L A IN S T AL ACI Ó N, USO Y M ANT ENIM IENTO M A NU AL DE I NST A L A Ç Ã O INS T R UÇ Õ E S DE US O E MA NU T E NÇ Ã O Å Ã× Å ÉÑÉÄÉÏ ÏÄ Ç Ã ÉÙ Í ÔÏÐ ÏÈ Å ÔÇÓ Ç Ó ÊÁ É × ÑÇ Ó Ç Ó I G B F D E P GR 1 ABCD EF G H I 2 5467 28 10911 13 60 mm 80 mm 100 mm 60 m
31 UNICO INVERTER ENGLISH couple the two chains to the large eyelet of the spring. - Using one hand, grip the two chains connected to the grid. - Bend the external grids back, gripping them with your free hand where they bend, and insert your fingers inside the single fins (fig. 13). - Insert your arm into the pipe until the grid protrudes completely outwards. - Reopen
Unico Celsius, 39 UNICO INVERTER ENGLISH • Check that mains power is present (by turning on a light for instance). • Check if the master switch is closed or if a fuse is burnt (in this case replace the fuse). If there is a magnetothermal circuit breaker instead of the master switch, check if it tripped (if it did, rearm it). Should the problem occur again, contact the Service Center at once and do not attempt to run the unit. • If the batteries are flat, you will notice that no messages are displayed and that the unit's reception confirmation sound is missing when you try to issue any command to it. In t
29 UNICO INVERTER ENGLISH 2 INSTALLATION 2.1 INSTALLATION MODES To obtain the best results and optimum performance, follow the instructions for correct installation provided in this manual. Failure to follow the instructions and apply the rules indicated may cause malfunction of the appliance and relieves the manufacturer, OLIMPIA SPLENDID of any form of guarantee and liabil
Unico Celsus Air Conditioner Instructions for installation, use and maintenance manual
Celsus |
Samsung AD26B1C13 Air Conditioner Service manual
AD26B1C13 |
Kenworth Y53-1024 Air Conditioner Operator's manual
Y53-1024 |
Koldfront PAC705 Air Conditioner Owner's manual
PAC705 |
Mitsubishi SRK21CNS-S6 Air Conditioner Technical manual
SRK21CNS-S6 |
Daikin FTXD60JV1B Air Conditioner Operation & user’s manual
FTXD60JV1B |
Airxcel 48000 Series Air Conditioner Installation instructions manual
48000 Series |
Mitsubishi Electric MUZ-A09NA Air Conditioner Service manual
MUZ-A09NA |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Masterbuilt | 20150108 | Assembly, care & use manual | masterbuilt/20150108-44I.pdf | 01 Feb 2024 | 6 | |
2 | Ricoh | 2045 | Configuration | ricoh/2045-F81.pdf | 16 Feb 2023 | 6 | 0.07 Mb |
3 | Whirlpool | LA5300XP | Use and care manual | whirlpool/la5300xp-9KL.pdf | 08 Nov 2023 | 16 | |
4 | Sony | CFDG770CPK | Operating instructions | sony/cfdg770cpk-2QY.pdf | 15 Dec 2022 | 2 | 0.73 Mb |
5 | Omegon | LRF 600 | Instruction manual | omegon/lrf-600-4IG.pdf | 20 Sep 2022 | 2 | |
6 | Frigidaire | GLGH1642DS1 | Operating instructions | frigidaire/glgh1642ds1-7CQ.pdf | 25 Sep 2023 | 4 | 0.16 Mb |
Mitsubishi Electric
SERVICE MANUALWireless typeModelsMCFH-GA35VB-(WH)MCFH-GA50VB-(WH)MCFH-GA60VB-(WH)E1E1E1No. OB380(When installed on the ceiling)(When installed on the floor)FLOOR AND CEILING TYPE AIR CONDITIONERSNOTE:• This manual describes technical data of indoor units• As for outdoor units MUCFH-GA35VB/GA50VB/GA60VB- , refer to the service manual OB381.• As for outd …
MCFH-GA35VB(24 pages) |
GE
Write the model and serial numbers here:Model # _________________Serial # _________________You can find the rating label on the side of the air conditioner.GE is a trademark of the General Electric Company. Manufactured under trademark license.AIR CONDITIONERROOM49-5000550 Rev. 0 09-20 GEAAEE08AEE12SAFETY INFORMATION .........3USING THE AIR CONDITIONER …
Appliances AEE08(52 pages) |
LG
OWNER’S MANUAL AIR CONDITIONER Please read this manual carefully before operating your set and retain it for future reference. www.lgappliances.comTYPE:PORATBLE AIR CONDITIONERMODELS: LP1011WXR,LP1210BXR
…
LP1210BXR(48 pages) |
York
L23952Y 1-05INSTALLATION, OPERATION, & MAINTENANCEFAN COILAIR CONDITIONERSSupersedes: Form 115.20-NOM2 (1199)Form 115.20-NOM2 (105)***** WARNING TO INSTALLER, SERVICE PERSONNEL AND OWNER ***** Altering the product or replacing parts with non authorized factory parts voids all warranty or implied warranty and may result in adverse operational performance …
YCHBC(16 pages) |
Haier
No. 0150501211Please read this manual carefully before using this air conditionerPlease keep this manual safely for future useWALL MOUNTED TYPE INDOOR UNITAS072XVERAAS092XVERAAS122XVERAAS182XVERAOPERATION MANUALINSTALLATION MANUALENMANUALE DI ISTRUZIONIMANUALE DI INSTALLAZIONEITMANUEL D’INSTRUCTIONSMANUEL D’INSTALLATIONFRBEDIENUNGSANLEITUNGINSTALLATIONSA …
AS072XVERA(69 pages) |
Friedrich
ENGLISHRoom Air ConditionerInstallation and OperationManualRegistering Your Room Air ConditionerModel information can be found on the name plate located on theside of the unit near the control panel. Please complete and mailthe owner registration card furnished with this product or register on-line at www.friedrich.com (USA only). For your future convenienc …
CP Line CP05(43 pages) |
Samsung Flat Panel TV PDP SeriesSamsung Flat Panel TV Quick start manual (File: samsung-pdp-series-flat-panel-tv-5, 03rd Jan 2024) PDP Series, 5 |
DeWalt Power Tool DC927-XEDeWalt DC927-XE Guide (Instruction manual), @V55PYW DC927-XE, 16 |
TocomSat Receiver DVB-S2 HDDVB-S2 HD (Receiver ePDF Manual, #7O89ZE) DVB-S2 HD, 32 |
Sony CD Player D-V55Sony CD Player D-V55 Operating instructions manual D-V55, 34 |
Carrier Air Conditioner Infinity 50XL#MP5AX7 Infinity 50XL: Carrier Air Conditioner Owner Documentation Infinity 50XL, 4 |
Esoteric CD Player P-02 sCD Player #18TX51 P-02 s, 84 |
3Com Network Card EtherLink 3C509BUser Manual: 3Com EtherLink 3C509B (556348, Upd.Sunday 03-12-2023) EtherLink 3C509B, 122 |
Fujitsu Air Conditioner ASTA12LFCFujitsu Air Conditioner Operating manual (File: fujitsu-aotr09lfc-operating-manual-20, 04.11.2023) ASTA12LFC, 20 |
Samsung Camcorder VM-C890PDF User Guide (@28BK2Y), Samsung VM-C890 Camcorder (18.01.2024) VM-C890, 1 |
Advantech Desktop ARK-3389#XW27YC ARK-3389: Advantech Desktop Owner Documentation ARK-3389, 64 |
New Rock Technologies IP Phone NRP1002/PNRP1002/P (IP Phone ePDF Guide, #ANW95R) NRP1002/P, 68 |
Pure Acoustics Speakers SUPERNOVA Series#TDU9X1: SUPERNOVA Series Speakers Owner's manual SUPERNOVA Series, 2 |