Text of Unico Celsus User Guide:

  • Unico Celsus, 38 ENGLISH 3.3.15 Starting and stopping the operating programs After having made the settings for the operating programs, they can be used or not, as needed. Either or both of the programs can be used. In particular, each time you press the button T11 (Program activation), the situation changes as follows: Use of Program no. 1 only. Use of Program no. 2 only. Use of Programs 1 and 2. Disuse of both programs.. 3.3.16 Resetting all remote control functions Press the button T10 to reset all the rem

  • Unico Celsus, 36 ENGLISH 3.3.3 Turning the unit ON/OFF Using button T1 it is possible to switch off (stand-by) or switch on the system. Since the machine's control system has a memory, no setting will not be lost when it is turned off. This button serves to switch the air conditioner on or off for brief periods of time. In case of prolonged stop of the machine, it must be deactivated turning the main switch off or unplugging the machine from the mains. 3.3.4 Well-being key (automatic operating) By pressing button T2 the appliance will automatically arrange to obtain optimal comfort

  • 30 ENGLISH To prevent the creation of large amounts of dust and rubble due to drilling, the core borer can be fitted with a vacuum system applied by means of suction cups to the drilling zone. Our Service Department can give you all necessary information to enable you to find these devices. To drill the holes, proceed as follows: Fasten the drilling template to the wall

  • Unico Celsus, 28 ENGLISH 1.4.1 Storage Store the packages in a closed room, protected from atmospheric agents and resting on pallets or beams to isolate from the ground. DO NOT OVERTURN THE PACKAGE. 1.4.2 Receipt and unpacking The products are packaged by expert personnel using suitable packaging material. The units are delivered complete and in perfect condition, however we suggest that you perform the following controls of the quality of the shipping service: - on receiving the goods, check if the package is damaged. If affirmat

  • Unico Celsus, 39 ENGLISH UNICO • Check that mains power is present (by turning on a light for instance). • Check if the master switch is closed or if a fuse is burnt (in this case replace the fuse). If there is a magnetothermal circuit breaker instead of the master switch, check if it tripped (if it did, rearm it). Should the problem occur again, contact the Service Center at once and do not attempt to run the unit. • If the batteries are flat, you will notice that no messages are displayed and that the unit's reception confirmation sound is missing when you try to iss

  • Unico Celsus, 40 ENGLISH 3.5.3 Specifications For the technical data listed below, consult the characteristic data plate applied to the product - Power supply voltage - Maximum power absorbed - Maximum current absorbed - Coolant power - Coolant gas - Protection rating of the containers - Max working pressure Dimensions (W x H x D) mm 902x516x229 Weight (without packing) kg 40 OPERATIONAL LIMITS Internal ambient temp. Outside ambient temp. Maximum operating temperature DB 35°C - WB 24°C DB 43°C - WB 32°C in coolin

  • Unico Celsus, 25 UNICO ENGLISH 1 GENERAL 1.1 SYMBOLS----------------------------------------------------------------------------------------------------------------------26 1.1.1 Editorial pictograms ---------------------------------------------------------------------------------------------------------- 26 1.1.2 Safety pictograms------------------------------------------------------------------------------------------------------------- 26 1.2 GENERAL INFORMATION -------------------------------------------------------------------------------------------------- 26 1.3 WARNING -

  • Unico Celsus, 27 ENGLISH UNICO THE MANUFACTURER IS NOT RESPONSIBLE FOR DAMAGES TO PERSONS OR PROPERTY CAUSED BY FAILURE TO FOLLOW THE INSTRUCTIONS IN THIS MANUAL. The manufacturer reserves the right to modify at any time its models without changing the fundamental characteristics described in this manual. The installation and maintenance of air-conditioners like this one may be hazardous as they contain a cooling gas under pressure as well as powered parts. Therefore, the installation, first startup and subsequent maintenance should be carried out exclusively by authorized, qualified personnel. This unit complies with European Directives 2006/95/EC, 2004/1

  • Unico Celsus, 2 I STRU Z I O NI P ER I NST AL L AZ I O NE, U SO E MANUT ENZ ION E INST R UCT I O NS FO R I NST AL L ATION , U SE AND M A I NTENA NCE I NST RUC TI ONS P O U R L 'I NST A L L A T I O N , L 'EM PLO I E T L 'E NT RETIE N HAND BUCH FÜR I NST AL L A TION , G EBRA UCH U N D W A RT U NG IN ST RUC CI O N ES P ARA LA IN S T AL ACI Ó N, USO Y M ANT ENIM IENTO M A N UA L DE I N ST ALAÇ ÃO I N STRU ÇÕES DE U SO E MA NU T E N Çà O Å Ã× ÅÉÑÉ ÄÉÏ Ï Ä Çà ÉÙ Í ÔÏÐ ÏÈÅ Ô Ç Ó ÇÓ ÊÁ É × Ñ ÇÓ Ç Ó I G B F D E P GR 1 ABCD EF G H I 2 5467 28 10911 13 60 mm 80 mm 100 mm 60 mm 3 4

  • Unico Celsus, 32 ENGLISH - remove the wooden wedge from behind the unit - lock the cable's three poles in the terminal strip and tighten the screws (fig. 19 ref. C) - block the cable with the clamp (fig. 19 ref. B) - close the protection of the board (fig. 19 ref. A) - refit the front cover of the machine with the six screws - refit the two wedged-in covers (upper and lower). CAUTION: these operations should be performed with the machine already positioned on the bracket. Read the instructions carefully befor

  • Unico Celsus, 35 ENGLISH UNICO For example, do not: - leave it out in the rain, spill water on its keyboard or drop it into water - subject it to impacts or drop it onto hard surfaces - leave it exposed to direct sunlight - place obstacles between the remote control and the air conditioner while using it. Furthermore: - if other devices operated by remote control (TV, radio, stereo systems, etc.) are located in the same room as the air conditioner, there may be interference, - electronic and fluorescent lighting may interfere with communications between the remote control and the air conditioner, - remove the batteries in case of prolonged disuse of the remote control. 3.2.2 Fit

  • 34 ENGLISH To ensure effective internal air filtration and satisfactory operation of your air conditioner, the air filter has to be cleaned periodically. Signalling of the requirement for this important maintenance operation is signalled after a long period of operating by the illumination of the red LED positioned on the signal console. The air filter is at the top of the unit. Remov

  • Unico Celsus, 37 ENGLISH UNICO mode, the onboard microprocessor adjusts the automatic speed. The higher the difference between the room temperature detected and the temperature set, the higher the speed. As the room temperature nears the setting, fan speed is reduced automatically. In dehumidification mode, it is not possible to control the speed as the appliance can only operate exclusively at low speed. 3.3.11 Night well-being key Press the T3 button (night well-being) to obtain several results, specifically: - Gradual increase of the set cooling temperature. - Gradual decrease of the temperature set for heating (only HP models). - Decrease of the unit&apos

  • Unico Celsus, ISTRUZIONI PER INSTALLA ZIONE, USO E MANUTENZIONE INSTRUCTIONS FOR INSTALLATION, USE AND MAINTENANCE INSTRUCTIONS POUR L'INSTALLATION, L'EMPLOI ET L'ENTRETIEN HANDBUCH FÜR INSTALLATION, GEBRAUCH UND WARTUNG INSTRUCCIONES PARA LA INSTALA CIÓN, USO Y MANTENIMIENTO I GB F D E

  • Unico Celsus, 31 ENGLISH UNICO couple the two chains to the large eyelet of the spring. - Using one hand, grip the two chains connected to the grid. - Bend the external grids back, gripping them with your free hand where they bend, and insert your fingers inside the single fins (fig. 13). - Insert your arm into the pipe until the grid protrudes completely outwards. - Reopen the grid, being careful to keep your fingers inside the fins. - Turn the grid until the fins are fully horizontal and tilted downwards. - Pull the chain, tensioning the spring, and couple the chain ring to the pin of the inner flang

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Cisco Catalyst 1800 Guide Manual  cisco/catalyst-1800-guide-L3D.pdf 17 Apr 2023 8 0.11 Mb
2 Clarion NX602 Owner's manual clarion/nx602-69B.pdf 15 Aug 2022 101 2.11 Mb
3 LENCO BTS-100 Gebruikershandleiding lenco/bts-100-A58.pdf 10 Jun 2023 4
4 ATEN CS-1742 Operation & user’s manual aten/cs-1742-627.pdf 21 Jul 2022 37 0.31 Mb
5 Brother MFC-J4510DW Manual  brother/mfc-j4510dw-SR1.pdf 27 Jun 2022 18 0.9 Mb
6 HP 4400 Software manual hp/4400-5A5.pdf 07 May 2023 77 3.1 Mb

Similar Resources:

  • Global

    292850

    (36 pages)
    1Portable Air Conditioner062019globalindustrial.caUser's manual Manual del usuario Manuel de l'utilisateurCustomer ServiceUS: 1-800-645-2986Servicio de atención al ClienteUS: 1-800-645-2986Service à la clientèleCanada: 888-645-2986 WARNINGRead all instructions before use. To reduce the risk of fire, electric shock, or injury to persons w …
  • GE

    AJCH 08 ACB

    (76 pages)
    Cool Only: AJCH 08, 10 ACBAJCH 10, 12 DCBAJCQ 06 LCBAJCQ 08, 10 ACBAJCQ 10, 12 DCBAJCS 06 LCBAJCS 08, 10 ACBAJCS 09, 10, 12 DCBHeat/Cool: AJEH 12 DCBAJES 06 LSBAJES 08 ASBAJES 09, 10, 12 DCBAJES 10 DSBHeat Pump: AJHS 08 ASBAJHS 08, 10 DCBWrite the model and serial numbers here:Model # ____________________Serial #______________________Find these numbers on …
  • Mitsubishi Electric

    PLA-RP.BA Series

    (22 pages)
    Air-ConditionersPLA-RP·BAINSTALLATION MANUALFor safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.FOR INSTALLEREnglishRG79D251K01_EN_0227.indd 1RG79D251K01_EN_0227.indd 1 28/02/2007 09:48:4628/02/2007 09:48:46 …
  • Carrier

    42QHF009DS

    (5 pages)
    INSTALLATIONG BENGLISHINSTALLATION MANUALIITALIANOMANUALE DI INSTALLAZIONE FMANUEL D’INSTALLATIONDINSTALLATIONSANWEISUNGDEUTSCHEMANUAL DE INSTALACION N LMONTAGE-INSTRUCTIES NEDERLANDSAHI CARRIER S.E. EUROPE AIRCONDITIONING S.A.18, KIFISOU AVENUE10442 ATHENS, GREECETEL,; +30-210-6796300. …
  • Samsung

    A437 - SGH Cell Phone

    (120 pages)
    Serie SGH-a437TTELÉFONO MÓVILPORTATIL DE BANDA CUÁDRUPLEManual del UsuarioPor favor lea este manual antes de usar el teléfono y consérvelo para consultarlo en el futuro. …
  • Carrier

    LUVH025N-1

    (8 pages)
    INVERTER SPLIT TYPE-Before using your air conditioner, please readthis manual carefully and keep it for future reference.ROOM AIR CONDITIONERRead This ManualInside you will find many helpful hints on how to use and maintain your air conditioner properly. Just a little preventative care on your part can save you a great deal of time and money overthe life of …

Comments, Questions and Opinions: