  • 5. Instructions for Use 5.3 Baskets and Accessories Observe the instrument manufacturer's recommendations for cleaning and care. When loading the unit, arrange loose instruments so that they do not touch one another. Instruments with concave surfaces or cavities should be placed so that water can drain freely. The following are included with the Hydrim: Rack fo

  • SciCan HYDRIM L110w, 6.1 Replacing the HIP Cleaning Solution The Hydrim L110w uses a 3.8L / 1 gallon container of HIP Cleaning Solution (Part number CS-HIPL). Use only the recommended cleaning solution and read the MSDS before inserting into the unit. To order additional HIP Cleaning Solution, contact your local dealer. When the message “no detergent” appears on the screen, the cleaning solution container is empty and is in need of changing. To avoid spillage, replace the solution container only when the message appears and be sure to wear g

  • SciCan HYDRIM L110w, 4.0 FIRST AID MEASURES Eye: Immediately flush with water for 15 minutes while lifting eyelids and rolling eyes. Get medical attention if irritation develops or persists. Skin: Wash promptly with soap and water. Ingestion: Get medical help. Do NOT induce vomiting. If conscious and medical help not readily available, give water. Inhalation: Not a normal route of exposure. If symptoms develop, move to fresh air. If breathing is difficult get medical attention. 5.0 FIRE FIGHTING MEASURES Flash point: Not Available Auto-Ignition temperature: Not Available Extinguisher Media: Water spray, dry chemical, foam, carbon dioxide. Special Fire Fighting

  • SciCan HYDRIM L110w, 14 5. Instructions for Use 5.9 Setup Menu To access the Setup Menu, proceed to the menu screen by turning the Hydrim OFF and then ON. An i (information) will appear briefly at the bottom right hand corner. Touch the i to move to the Menu screen and select Setup. The Setup Menu consists of seven choices as shown. Using the up and down arrows to move through the choices, touch the desired option to select it. For more detail on each setup menu option, refer to the following sections. SH11MR301 HYDRIM User Menu Technician Setup Unit No. Setup Language Selectio

  • SciCan HYDRIM L110w, 6.4 Cleaning the Hydrim L110w To clean outer surfaces and the decal covering the touchscreen, use a soft cloth moistened with soap and water or a surface disinfectant. Do not use harsh cleaning chemicals. If preparing the unit for transport or storage, waste water should be removed from the sump. Waste water in the unit may contain biological contaminants. Use a mechanical means to siphon the contents. Wear disposable rubber gloves. Dispose of absorbent material according to biological waste disposal regulations. 6.5 Filter and Wash Arm Ma

  • SciCan HYDRIM L110w, Do not permit any person other than authorized personnel to service, maintain or supply parts for your Hydrim L110w. SciCan shall not be liable for incidental, special or consequential damages caused by any maintenance or services performed on the Hydrim L110w by unauthorized personnel, or for the use of equipment or parts manufactured by a third party, including lost profits, any commercial loss, economic loss, or loss arising from personal injury. Never remove the covers of the unit and never insert objects through holes or openings in the cabinetry. Doing so may da

  • SciCan HYDRIM L110w, 8.0 PHYSICAL/CHEMICAL CHARACTERISTICS Physical State: Liquid Boiling Point: No Data pH: 9.5-10.5 Specific Gravity: 1.14-1.15@25°C Solubility in Water: 100% soluble in water. Appearance and Color: Clear colorless to slight yellow. Melting Point: No Data 9.0 PHYSICAL HAZARDS/REACTIVITY DATA Stability: Stable under normal conditions of handling, use and transportation. Incompatibility (Materials to Avoid): Acids. Hazardous Decomposition Products: Combustion produces carbon dioxide and carbon monoxide

  • SciCan HYDRIM L110w, 5.1 Instrument Reprocessing Recommendations The Hydrim L110w is designed to clean general dental and medical instruments. SciCan recommends terminal sterilization after processing in the Hydrim L110w. When used correctly, the Hydrim L110w is effective for the removal of debris on instruments that may result in the insulation of microorganisms during terminal sterilization. Prior to placing instruments in the Hydrim, consult the instrument manufacturer's reprocessing instructions. All critical and semi-critical instruments can be considered clean after processing in the Hydrim L110w. Non-critical instruments can be terminally processed in the

  • SciCan HYDRIM L110w, 21 7. Troubleshooting Instruments are not clean Touchscreen / Unit does not come on The wash arms do not rotate The door cannot be opened Operating cycles appear to be taking too long to complete “No detergent” message comes on when there is still chemical left in the container Drying Performance is inadequate Possible Causes and SolutionsProblem • Do not overload cassettes or instrument baskets. • Do not load too many cassettes into the Hydrim. • Use the Heavy Duty cycle for cassettes and hinged instruments. • Check filters and wash arms for debris. • Ensure that the

  • 7 5. Instructions for Use 5.2 Cycle Description Chart * This is not a wash cycle. Always run a wash cycle following the rinse and hold cycle. ** Cycle times depend on the temperature and pressure of incoming water. P1 – Rinse and P2 – Regular P3 – Heavy Duty Hold* Cycle Cycle Cycle Description Cold Prewash <45ºC / 113ºF N/A <45ºC / 113ºF Wash N/A 50ºC / 122ºF 50ºC /

  • 11 5. Instructions for Use Set Drying Time User Technician Setup Error History Cycle Count Set Button Beep Screen Saver Temperature C/F LCD Contrast Unit No. Language Selection Set Regeneration SH11MR301 HYDRIM 5.6 Overview of Hydrim L110w Menus

  • SciCan HYDRIM L110w, 12 5. Instructions for Use 5.7 User Menu To access the user menu, follow these steps: Turn the Hydrim OFF and then ON. An i (information) will appear briefly at the bottom right hand of screen. Touch the i to move to the Menu screen. Select User. SH11MR301 HYDRIM User Menu Technician Setup The user menu consists of three choices. Set Drying Time User Menu Error History Cycle Count 10min Set Drying Time P2 Wash Default 10min User Menu – Set Drying Time The drying time for P2 and P3 can be set independently. P1 does not have a drying cycle. Touch the cycle for which you want to set the drying time. Use the up and down arrows to select the

  • SciCan HYDRIM L110w, 10 5. Instructions for Use The cycle will start by draining the unit for 20 seconds. The bar on the screen indicates the progression of the cycle. The stage within the cycle is shown beneath the bar (eg. Filling, Rinsing). The estimated time remaining (in minutes) is always displayed. Please note that the time will increase or decrease depending on the projected cycle completion. When the cycle is complete, the program name and “Cycle Complete” is displayed, and the unit beeps three times. Press to op

  • SciCan HYDRIM L110w, 2 2. Important Information The following symbols appear in this book. Caution, there is a potential hazard to the operator. This situation may lead to a mechanical failure. This is important information. The following symbols appear on the touchscreen: Used to stop the cycle Forward Arrow – used to move to the next menu Back Arrow – used to move to the previous menu Up Arrow – used to adjust a value up, or to move between screens in a menu Down Arrow – used to adjust a value down, or to move between screens in a menu Unlock – used to unlock the door Used to clear the error history Info menu – allows access to User, S

  • SciCan HYDRIM L110w, Setup Menu – Set Button Beep The user can select between having the unit beep or not beep whenever a screen button is touched. Turn the beep on or off by using the up and down arrows. Note that the default setting is ON. Touch the back arrow to return to the previous menu. Setup Menu – Screen Saver The user can adjust the time that elapses before the screen goes into screen saver mode. Touch Screen Saver. Touch the up and down arrows to select the desired screen saver setting. The default is 4 minutes. Touch the back ar

  • SciCan HYDRIM L110w, Height, freestanding: 850 mm / 33.5" Height, built-in: 810 mm / 32" Width: 600 mm / 23.75" Depth: 600 mm / 23.75" Depth with door open: 1200 mm / 47" Weight: 80 kg / 176 lbs. Running Noise: 60 dB(A) Hot and cold water connections: 3/4” Inlet water pressure: 1-10 bar Incoming hot water temperature: 50-70°C / 122-158°F Drain: 3/4” Water softener: 1 kg / 2.2 lbs salt capacity Filling System: 5.5L / 1.5 gallon safety maximum Drying System: Heater 1 kW Electrical Connection: 208-240 V 60 Hz 15 A Equipment pollution degree: Pollution Degree 2 Equipment installation c

  • SciCan HYDRIM L110w, Label Number: 09-109256 Rev 3.0 (artwork L110p Hip bag/box) Created December 22, 2006 5.4 Activating the Hydrim L110w Prior to activating the washer, check that the water supply is on and follow these steps: 9 5. Instructions for Use Open the chemical door and ensure that a box of HIP Cleaning Solution has been installed. Load instruments into the baskets or cassettes, place them in the machine and close the door. Touch the screen to begin. Select the desired cycle. The cycle will start automatically. (Use a heavy duty cycle for cassettes, hinged instruments or heavily soiled instruments.) Turn the uni

  • SciCan HYDRIM L110w, Table of Contents 1. Introduction . . . . . . . . . . . . . . . . . . . . . . 1 2. Important Information . . . . . . . . . . . . . 2 3. Disclaimers . . . . . . . . . . . . . . . . . . . . . . 3 4. Installation Instructions . . . . . . . . . . . . 4 5. Instructions for Use . . . . . . . . . . . . . . . 6 5.1 Instrument Reprocessing Recommendations . . . . . . . . . . . . . . . . . . 6 5.2 Cycle Description Chart. . . . . . . . . . . . . . 7 5.3 Baskets and Accessories. . . . . . . . . . . . . 8 5.4 Activating the Hydrim L110w . . . . . . . . . . 9 5.5 Interrupting / Aborting a Cycle . . . . . . . . 10 5.6 Overview of the Hydrim L110w Menus

  • SciCan HYDRIM L110w, 22 7. Troubleshooting CF1 Water Heating failure CF2 Chamber Filling Failure CF3 Chamber temperature reading failure CF4 Draining failure CF9 Software or PCB Failure CF11 No detergent CF14 Fault Flow Switch CF15 Chamber overflow SolutionError The water does not reach the required temperature in the specified time The water does not fill the chamber within the specified time. Faulty sensor. Water cannot drain from the unit. Cycle length is more than 2hr 30 min. Flow switch did not detect detergent during wash phase. Flow switch is stuck closed. Overflow switch did not

  • SciCan HYDRIM L110w, Thank you for selecting the Hydrim L110w instrument washer. The Hydrim complements the Statim autoclave by quickly and hygienically preparing soiled instruments for sterilization. To ensure years of safe, trouble-free service, carefully review this Operator’s Manual before operating the unit. The Hydrim L110w is suitable only for the applications listed in this manual. Using the Hydrim for other purposes may be dangerous. The manufacturer cannot be held responsible for damage caused by improper use. Operational, maintenance and replacement instructions must be followed f

  • 6. Care and Maintenance 6.2 Refilling the Water Softening Salt Reservoir When the error message "salt level low" appears, the salt reservoir is in need of refilling. Ensure that your authorized technician has set the water softener according to the hardness level in your area. To fill the salt reservoir, follow these steps: 1. Unscrew the salt container

  • SciCan HYDRIM L110w, 8. Material Safety Data Sheet 1.0 PRODUCT AND COMPANY IDENTIFICATION Product Name: HIP – Hydrim Cleaning Solution With Instrument Protection Product Use: Cleaner Manufacturer/Supplier: Virox Technolgies Inc. Address: 2815 Bristol Circle, Unit 4, Oakville, Ontario L6H 6X5 Phone #: (905) 813-0110 (W)HMIS Classification: Health: 2 Flammability: 0 Reactivity: 0 Personal Protection: B (Gloves + Goggles) 2.0 INFORMATION ON ACTIVE INGREDIENTS Ingredient CAS# Wt% OSHA-PEL ACGIH-TLV 1-Hydroxyethane 2809-21-4 5-10% N/E N/E -1,1-Diphosphonic acid, K salt 1, 2 propylene glycol 57-55-6 15-20% N/E N/E Xylenesulfonic acid,

  • SciCan HYDRIM L110w, Setup Menu – Unit Number If you have more than one Hydrim, you can designate them Unit #1, Unit #2, etc. Use the up and down arrow keys to select the unit number. The default is 0. Setup Menu – Language Selection This allows the user to select among available languages for the Hydrim. Use the up and down arrows to select the desired language. The default language is English. Touch the back arrow to return to the previous menu. Setup Menu – Set Regeneration Set the salt regeneration according to the local water hardness. Use the up and down arrows to change the value. The default setting is 0 . See Installation Instructions for furt

Related Products and Documents (Washer):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Ford Taurus Quick reference manual ford/taurus-439.pdf 21 Aug 2023 8
2 ViewSonic PJ452 - LCD XGA Projector-4.9LBS Service manual viewsonic/pj452-lcd-xga-projector-4-9lbs-SES.pdf 09 Jul 2022 70
3 Cannon Fitzroy FITZIB-PMEXx Instruction manual cannon/fitzroy-fitzib-pmexx-WGM.pdf 03 Jul 2023 24 2.26 Mb
4 Supco SDE362 Installation instructions supco/sde362-117.pdf 24 Oct 2023 2
5 ZyXEL Communications 2R-P1C Operation & user’s manual zyxel-communications/2r-p1c-P47.pdf 17 Jul 2022 53 3.45 Mb
6 TEFAL TRAVEL CITY Manual  tefal/travel-city-6ON.pdf 19 Dec 2023 81 1.08 Mb

Similar Resources:

  • LG

    WM3550H

    (2 pages)
    A WASHER THAT LETS YOU HAVE IT ALLA powerful steam clean, ultra-large capacity, and gentle on fabrics sound too good to be true in a single washer? Not anymore. This 4.3 cu. ft. ultra-large capacity washer uses TrueSteam™ technology with powerful steam that penetrates into your clothing, while still being gentle on even your most delicate fabrics. And with …
  • Maytag

    MVWX600XW1

    (36 pages)
    TOP-LOADINGHIGH EFFICIENCYLOW-WATER WASHERUSE AND CARE GUIDEGUIDE D'UTILISATIONET D'ENTRETIEN DELA LAVEUSE HAUTEEFFICACITE A FAIBLECONSOMMATION D'EAUAVEC CHARGEMENT PARLE DESSUSTable of ContentsWASHER SAFETY ......................................................... 2WHAT'S NEW UNDER THE LiD? ................................. 3CONTROL PANE …
  • Whirlpool

    FRONT-LOADINGAUTOMATIC WASHER

    (52 pages)
    FRONT-LOADING AUTOMATIC WASHERUse & Care GuideFor questions about features, operation/performance,parts, accessories or service call: 1-800-253-1301In Canada, call: 1-800-807-6777 or visit our website atwww.whirlpool.com or www.whirlpool.caLAVEUSEAUTOMATIQUE ÀCHARGEMENT FRONTALGuide d’utilisation et d’entretienAu Canada, pour assistance, installatio …
  • Simpson

    SWT6041

    (32 pages)
    SWT5541SWT5541BSWT6041SWT6541SWT6541MSWT6541QSWT6541TTOP-LOAD WASHING MACHINE USER MANUAL...................................................... ................................................. …
  • Haier

    GWT450AW

    (53 pages)
    Top Load Clothes WasherMachine a LaverLavadora de Ropa con Carga Superior User Manual Model # GWT450AWGuide de l’Utilisateur Modéle # GWT450AWManual del Usuario Para Modelo de # GWT450AW Quality•Innovation•StylePicture for illustration purposes only. …
  • Hoover

    Power Scrub

    (19 pages)
    sOWNER'SMANUALOperatingandServicingInstructionsEspanol-paginaE1/Frances-pagwww.hoover.compowerSCRUBCARPETWASHERPleasevisitHoover.comforvideoinstructions,forthiscleaner.IMPORTANT:READCAREFULLYBEFOREASSEMBLYANDUSE.Questionsorconcerns?Forassistance,pleasecallCustomerServiceat1-800-944-9200Mon-Fri8am-7pmESTbeforereturning thisproducttothestore.THISPRODUCTIS …

Comments, Questions and Opinions: