Cooper Wheelock SAFEPATH4 SP4-LOC Installation And Operation Manual
|
Cooper Wheelock SAFEPATH4 SP4-LOC, SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.
Cooper Wheelock SAFEPATH4 SP4-LOC, 3 Introduction Thank you for using our products. Use this product according to this instruction manual. Please keep this instruction manual for future reference. The SP4 –LOC Remote Microphone and Local Operator Console is designed to be used with the Facility Communications System using the SafePath4 SP40/2 and the SP40S panels. It contains the SafePath4 SPRM Remote Microphone Module and eight black Push On /Push Off buttons which provide a contact closure to activate the SP40/2 or the SP40S digital messages in the Push On position. These buttons change color from black in the OFF position to green in the ON position. A message name
Cooper Wheelock SAFEPATH4 SP4-LOC, 4 Notation Conventions This manual uses the following notation conventions: INDICATES A POTENTIALLY HAZARDOUS SITUATION THAT, IF NOT AVOIDED, COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH TO YOU AND OR OTHERS. Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices. Safety De-energize all electrical circuits and equipment associated with installing the SP4-LOC. If the HVAC Pushbutton option is being added, the circuit can contain high voltage that can cause serious injury or death to the installer. Additional c
Cooper Wheelock SAFEPATH4 SP4-LOC, 5 Technical Specifications Mechanical Dimensions (H x W x D) See Figure 1. Backbox: 15 1/4 x 14 1/2 x 4 in. Surface Front: 15 1/4 x 14 1/2 x 1/8 in. Flush Front: 16 1/4 x 15 1/2 x 1/8 in. Weight 8 lb. Finish White Mounting Indoor surface mount Indoor flush mount Wiring Entry Top, bottom and back knockouts (1/2” and 3/4”) (3 total) Door Lock Pull slam latch with 1/8” security tamper indicator installation holes PC Boards SPRM Environmental Operating Temperature 0 to 49 °C (32 to 120 °F) Storage Temperature -20 to 70 °C (-4 to
Cooper Wheelock SAFEPATH4 SP4-LOC, 6 MASS NOTIFICATION SYSTEM 15.50" 14.50" 16.25" 15.25" BACKBOX OUTLINE TRIM RING 1/2" PANEL DOOR Figure 1. Outside Dimensions for the SP4-LOC Front Mounting COMPLY WITH ALL OF THE LATEST APPLICABLE CODES, REGULATIONS, LAWS, STANDARDS, AND GUIDELINES. 1. Remove the FRONT DOOR ASSEMBLY from the backbox by removing the eight (8) nuts holding the assembly in place. 2. Remove the INNER DOOR ASSEMBLY (Figure 2) and terminal block from the backbox.
Cooper Wheelock SAFEPATH4 SP4-LOC, 7 MASS NOTIFICATION SYSTEM SAFEPATH4 REMOTE MICROPHONE (SPRM) EIGHT (8) PUSH ON/PUSH OFF BUTTON SWITCHES (WHEN THE GREEN PUSH SWITCH IS PUSHED TO THE ON POSITION, THE COLOR CHANGES TO BLACK.) MESSAGE NAMEPLATE HOLDER MOUNTING HOLE FOR OPTIONAL HVAC EMERGENCY CUTOFF PUSHBUTTON #8-32 TRUSS HEAD SCREWS FOR MOUNTING THE INNER DOOR Figure 2. Inner Door Assembly 2. Mount the backbox assembly. See Figure 3 for mounting holes. Insure that the orientation label inside the backbox is pointing “UP” and that the studs f
8 14.50" 15.25" 9.25" 11.00" SURFACE MOUNT HOLES (4) FLUSH MOUNT HOLES (8) 1/4"x1/2" DOUBLE KNOCKOUT (3) TOP, BOTTOM, AND BACK 1/2"/3/4" TERMINAL BLOCK MOUNTING STUDS #8-32 Figure 3. Mounting Holes for Mounting the Backbox, Flush and Surface 3. Connect conduit fittings to the desired cable knockouts,
9 Installing and Wiring the Inner Door 4. Place the terminal block with the wire harness pointing down, onto the terminal block studs. 5. Connect the wire tie around the harness and to the bottom terminal block stud. 6. Using the washers and nuts, fasten the terminal block to the backbox.. 7. If applicable, mount and wire the optional HVAC Emergency Shutoff push
Cooper Wheelock SAFEPATH4 SP4-LOC, 10 MASS NOTIFICATION SYSTEM S1 S2 S3 S4 S5 S6 S7 S8 SP4-LOC HARNESS WIRING S1 S2 S8 S7 S6 S5 S4 S3 _ _ + _ + + TB7 _ + IN1 IN2 IN3 IN4 _ _ + _ + + TB8 _ + IN5 IN6 IN7 IN8 SP40S Figure 5. Wiring Diagram SP4-LOC to SP40S NOTE: The SP40S inputs can be supervised by placing a 10K Ohm resistor across each pair of input terminals on the SP4-LOC terminal block and by switching ON the DIP switches on switch block SW7 positions 1 through 8. 9. Connect the SPRM to the SP40. Figure 6 shows the proper wiring connections for the SPRM to the SP40/2. Figure 7 shows the proper wiring connections for the SPRM to the SP40S.
Cooper Wheelock SAFEPATH4 SP4-LOC, 11 REMOTE MICROPHONE SP40/2 PANEL AUDIO OUT AUX IN CC/NAC + - + - TB6 24VDC RM AUDIO STATUS (CC) - + - + 654321 + - + - + - + + - - IN BAT 24V Figure 6. Wiring Diagram SPRM to SP40/2 This wiring is power limited. REMOTE MICROPHONE SP40S PANEL 24V OUT AUX CC/NAC + - + - TB6 24VDC RM AUDIO STATUS (CC) - + - + 654321 + - + - Figure 7. Wiring Diagram SPRM to SP40S This wiring is power limited. 10. Mount the INNER DOOR to the backbox using the four #8-32 truss head screws and plastic washers. 11. Mo
Cooper Wheelock SAFEPATH4 SP4-LOC, 12 MASS NOTIFICATION SYSTEM 1/8" SECURITY WIRE HOLES SLAM LATCH #8-32 X 3/4" STUDS (8) ON BACK OF FRONT RING 1/2" TRIM RING ON FLUSH MOUNT MODEL FRONT RING Figure 8. Front Door Layout Operating Instructions: SP40/2 Panel _ _ + _ + + TB6 AUX IN AUX CC/NAC AUX IN NAC CC W5 W4 SW4 100V 70V 25V 1V AUDIO OUT AUXILIARY INPUT SELECTION JUMPER J4. SELECT 1V POSITION CC/NAC SWITCH SW4 PLACE IN CC POSITION AUXILIARY INPUT SUPERVISION JUMPER W5. REMOVE FOR SUPERVISION. Figure 9. Switch locations on the SP40/2 for SPRM
Cooper Wheelock SAFEPATH4 SP4-LOC, 13 Figure 9 shows the locations of the switches and LED’s on the SP40/2 that are required for SPRM operation. 1. Set the NAC/CC switch (SW4) on the SP40/2 PC board to the CC position. 2. Set the AUX IN jumper J2 to the 1V position. 3. Remove AUX SUP jumper (W5). 4. Install a UL Listed 10K Ohm End of Line Resistor (EOLR) on the AUX IN of SP40/2. SP40S Panel _ _ + _ + + TB6 AUX CC/NAC 24V OUT CC/NAC SW6 100V 70V 25V 1V J4 AUX IN AUX SUP JP4 SP40S CC/NAC SWITCH SW6 PLACE IN CC POSITION AUXILIARY INPUT SELECTION JUMPER J4. SELECT 1V POSITION AUXILIARY INPUT SUPERVISION JUMPER JP4. REMOVE FOR SUPERVISION. Figure 10. Switch a
Cooper Wheelock SAFEPATH4 SP4-LOC, 14 HVAC SHUTO FF 1 2 1 2 3 5 4 3 MASS NOTIFICATION SYSTEM 4 INNER PANEL BACK BOX FRONT DOOR ASSEMBLY 5 6 6 7 7 (SURFACE AND FLUSH) 8 SYSTEM MASS NOTIFICATION 8 PARTS LEGEND: ELECTRICAL CONDUIT AND FIELD WIRES. (1/2" AND 3/4" KNOCKOUTS PROVIDED ON TOP, BOTTOM AND BACK FACE.) SP4-LOC BACKBOX ORIENTATION LABEL #8-32 TRUSS HEAD (4) INNER PANEL MOUNTING SCREW TERMINAL STRIP AND WIRING HARNESS 1/4" DIAMETER HOLE (6) TO ACCEPT #8-32 STUDS FROM FRONT DOOR PANEL. #8-32 SEMS NUT (6) PROVIDED. OPTIONAL "HVAC SHUTOFF" LABEL AND MUSHROOM HEAD PUSHBUTTON SWITCH 1/8" HOLES (2) FOR
Cooper Wheelock SAFEPATH4 SP4-LOC, 15 Warranty Limited Warranty Cooper Wheelock, Inc. products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained, and operationally tested in accordance with these instructions at the time of installation and at least twice a year or more often in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance, and testing must be performed by qualified personnel for proper operati
Cooper Wheelock SAFEPATH4 SP4-LOC, 16 foregoing shall constitute the sole remedy of the purchaser and the exclusive liability of Cooper Wheelock, Inc. In no case will Cooper Wheelock, Inc.'s liability exceed the purchase price paid for a product. Limitation of Liability Cooper Wheelock, Inc.'s liability on any claim of any kind, including negligence, breach of warranty, or otherwise, for any loss or damage resulting from, arising out of, or connected with any contract, or from the manufacture, sale, delivery, resale, repair or use of any product shall be limited to the price applicable to the product or part thereof
TANDBERG 550MXP Microphone Operation & user’s manual
550MXP |
DPA 5100 Microphone Operation & user’s manual
5100 |
Nady Systems HM-35 Microphone Operation & user’s manual
HM-35 |
Behringer STUDIO CONDENSER MICROPHONES C-2 Microphone Operation & user’s manual
STUDIO CONDENSER MICROPHONES C-2 |
Countryman E6 Microphone Operation & user’s manual
E6 |
Cooper Wheelock SPRM Microphone Installation instructions
SPRM |
Sennheiser EK 300 IEM G3 Microphone Instruction manual
EK 300 IEM G3 |
Mipro ACT-30Hr Microphone Operation & user’s manual
ACT-30Hr |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Edge10 | H170 | Operation & user’s manual | edge10/h170-HD8.pdf | 24 Apr 2023 | 17 | |
2 | Speco | CVC-627 | Operation & user’s manual | speco/cvc-627-UK6.pdf | 02 Apr 2023 | 16 | 3.65 Mb |
3 | Audience | ClairAudient 1+1 V1 | Owner's manual | audience/clairaudient-11-v1-BC1.pdf | 31 May 2023 | 2 | |
4 | KitchenAid | KBFU271 | Installation instructions and use & care manual | kitchenaid/kbfu271-B6N.pdf | 23 Feb 2024 | 24 | |
5 | HP | Z400 | Declaration of conformity | hp/z400-MS4.pdf | 15 Jul 2022 | 1 | 0.02 Mb |
6 | Clarson | CarCom | Operating instructions | clarson/carcom-32K.pdf | 13 Mar 2024 | 2 |
Sony
Digital WirelessPackageOperating InstructionsBefore operating the unit, please read this manual thoroughly and retain it for future reference.Please read this manual together with the manual supplied with the BC-DWZ1.DWZ-M70/B70HL4-460-562-14 (1)© 2012 Sony Corporation
…
DWZM70(26 pages) |
ICON
1ENGLISHFRANÇAISDEUTSCHEESPAÑOL日本語ITALIANOStudio large-diaphragm condenser microphoneMicrophone à condensateur de studio à large diaphragmeGroßmembran-Kondensatormikrofon für StudioaufnahmenMicrófono de condensador de estudio de diafragma grandeMicrofono a condensatore da studio a diaframma largoスタジオ用大口径ダイアフラム コン� …
M1(44 pages) |
LTO
User Guide English ( 3 – 11 ) Guía del usuario Español ( 12 – 20 ) Guide d’utilisation Français ( 21 – 29 ) Guida per l’uso Italiano ( 30 – 38 ) Benutzerhandbuch Deutsch ( 39 – 47 ) Gebruikershandleiding Nederlands ( 48 – 56 ) Appendix English ( 58 – 59 )
…
RADIUS 100(11 pages) |
CES
Page 1Model 710 DTMFProgrammable Microphone ManualCES Wireless Technologies925-122 South Semoran Blvd.Winter Park, FL 32792Tel 407.679.9440 Fax 407.679.8110Email: [email protected]: www.ceswireless.com06000561 REV F MAN08A REV 8/02© CES Wireless Technologies Corp 1991-2002
…
710 DTMF(12 pages) |
Kurzweil
KM-2U User ManualImportant Safety Instructions• Read the instruction manual carefully and completely before using the product.• Always include the instruction manual when passing the product on to third parties.• Do not use the product if defective or damaged.Power Requirements and Compatibility!The KURZWEIL KM-2U receives power supply from the compute …
KM-2U(5 pages) |
Sennheiser
• Sturdy metal housing (transmitter & receiver)• PC-supported frequency management for transmitter and receiver• Tunable UHF frequencies within a large switching bandwidth • Wireless microphone with programmable, easy-access MUTE switch• Quick-change microphone head from the e 800 Series • Large range of replaceable microphone heads from the …
EW 335(2 pages) |
HP Printer P3010Printer PDF Specifications P3010, 4 |
Vacmaster Vacuum Cleaner VQ607SFDVacmaster Vacuum Cleaner VQ607SFD Operator's manual VQ607SFD, 12 |
Velleman Amplifier K4005BAmplifier PDF Illustrated assembly manual K4005B, 16 |
Altec Lansing Alarm Clock M402User Guide: Altec Lansing M402 (2H363O, Upd.08th Jan 2024) M402, 14 |
Philips Hair Clipper QG3340Hair Clipper #PS3793 QG3340, 154 |
Dymo Printer LabelWriter 4XL Label PrinterPrinter #75TVY8 LabelWriter 4XL Label Printer, 20 |
Scientific Atlanta Universal Remote AT8400TMScientific Atlanta AT8400TM Guide (Operation & user’s manual), @T8M317 AT8400TM, 20 |
Jason International Hot Tub Integrity B3060Hot Tub #M5N4G4 Integrity B3060, 6 |
Sharp TV LC-32LE175HTV Operation manual (Sharp LC-32LE175H) LC-32LE175H, 30 |
GE Dishwasher GE Profile PDW8800JBB#QNJ4XE GE Profile PDW8800JBB: GE Dishwasher Owner Documentation GE Profile PDW8800JBB, 2 |
Uniden Two-Way Radio UH-088Two-Way Radio Owner's manual (Uniden UH-088) UH-088, 32 |
Zte Cell Phone BLADE A310#DS35QX BLADE A310: Zte Cell Phone Owner Documentation BLADE A310, 159 |