Manualios.com

Cooper Wheelock SAFEPATH4 SP4-LOC Installation And Operation Manual

  • SAFEPATH4 SP4-LOC Microphone
  • maK7mXtPZp1kI
  • Installation And Operation Manual
  • PDF / Adobe Acrobat Reader
  • 16

Cooper Wheelock SAFEPATH4 SP4-LOC Manual Online:

3.05, 1382 votes
Cooper Wheelock SAFEPATH4 SP4-LOC User Manual
Cooper Wheelock SAFEPATH4 SP4-LOC User Guide
Cooper Wheelock SAFEPATH4 SP4-LOC Online Manual

Text of Cooper Wheelock SAFEPATH4 SP4-LOC User Guide:

  • Cooper Wheelock SAFEPATH4 SP4-LOC, SP4-LOC SAFEPATH4 REMOTE MICROPHONE AND LOCAL OPERATOR CONSOLE INSTALLATION AND OPERATION MANUAL MASS NOTIFICATION SYSTEM Part Number: P84767 Rev. A Copyright 2006 Cooper Wheelock, Inc. All rights reserved.

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 3 Introduction Thank you for using our products. Use this product according to this instruction manual. Please keep this instruction manual for future reference. The SP4 –LOC Remote Microphone and Local Operator Console is designed to be used with the Facility Communications System using the SafePath4 SP40/2 and the SP40S panels. It contains the SafePath4 SPRM Remote Microphone Module and eight black Push On /Push Off buttons which provide a contact closure to activate the SP40/2 or the SP40S digital messages in the Push On position. These buttons change color from black in the OFF position to green in the ON position. A message name

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 4 Notation Conventions This manual uses the following notation conventions: INDICATES A POTENTIALLY HAZARDOUS SITUATION THAT, IF NOT AVOIDED, COULD RESULT IN SERIOUS PERSONAL INJURY OR DEATH TO YOU AND OR OTHERS. Indicates a potentially hazardous situation that, if not avoided, could result in minor or moderate injury. It may also be used to alert against unsafe practices. Safety De-energize all electrical circuits and equipment associated with installing the SP4-LOC. If the HVAC Pushbutton option is being added, the circuit can contain high voltage that can cause serious injury or death to the installer. Additional c

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 5 Technical Specifications Mechanical Dimensions (H x W x D) See Figure 1. Backbox: 15 1/4 x 14 1/2 x 4 in. Surface Front: 15 1/4 x 14 1/2 x 1/8 in. Flush Front: 16 1/4 x 15 1/2 x 1/8 in. Weight 8 lb. Finish White Mounting Indoor surface mount Indoor flush mount Wiring Entry Top, bottom and back knockouts (1/2” and 3/4”) (3 total) Door Lock Pull slam latch with 1/8” security tamper indicator installation holes PC Boards SPRM Environmental Operating Temperature 0 to 49 °C (32 to 120 °F) Storage Temperature -20 to 70 °C (-4 to

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 6 MASS NOTIFICATION SYSTEM 15.50" 14.50" 16.25" 15.25" BACKBOX OUTLINE TRIM RING 1/2" PANEL DOOR Figure 1. Outside Dimensions for the SP4-LOC Front Mounting COMPLY WITH ALL OF THE LATEST APPLICABLE CODES, REGULATIONS, LAWS, STANDARDS, AND GUIDELINES. 1. Remove the FRONT DOOR ASSEMBLY from the backbox by removing the eight (8) nuts holding the assembly in place. 2. Remove the INNER DOOR ASSEMBLY (Figure 2) and terminal block from the backbox.

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 7 MASS NOTIFICATION SYSTEM SAFEPATH4 REMOTE MICROPHONE (SPRM) EIGHT (8) PUSH ON/PUSH OFF BUTTON SWITCHES (WHEN THE GREEN PUSH SWITCH IS PUSHED TO THE ON POSITION, THE COLOR CHANGES TO BLACK.) MESSAGE NAMEPLATE HOLDER MOUNTING HOLE FOR OPTIONAL HVAC EMERGENCY CUTOFF PUSHBUTTON #8-32 TRUSS HEAD SCREWS FOR MOUNTING THE INNER DOOR Figure 2. Inner Door Assembly 2. Mount the backbox assembly. See Figure 3 for mounting holes. Insure that the orientation label inside the backbox is pointing “UP” and that the studs f

  • 8 14.50" 15.25" 9.25" 11.00" SURFACE MOUNT HOLES (4) FLUSH MOUNT HOLES (8) 1/4"x1/2" DOUBLE KNOCKOUT (3) TOP, BOTTOM, AND BACK 1/2"/3/4" TERMINAL BLOCK MOUNTING STUDS #8-32 Figure 3. Mounting Holes for Mounting the Backbox, Flush and Surface 3. Connect conduit fittings to the desired cable knockouts,

  • 9 Installing and Wiring the Inner Door 4. Place the terminal block with the wire harness pointing down, onto the terminal block studs. 5. Connect the wire tie around the harness and to the bottom terminal block stud. 6. Using the washers and nuts, fasten the terminal block to the backbox.. 7. If applicable, mount and wire the optional HVAC Emergency Shutoff push

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 10 MASS NOTIFICATION SYSTEM S1 S2 S3 S4 S5 S6 S7 S8 SP4-LOC HARNESS WIRING S1 S2 S8 S7 S6 S5 S4 S3 _ _ + _ + + TB7 _ + IN1 IN2 IN3 IN4 _ _ + _ + + TB8 _ + IN5 IN6 IN7 IN8 SP40S Figure 5. Wiring Diagram SP4-LOC to SP40S NOTE: The SP40S inputs can be supervised by placing a 10K Ohm resistor across each pair of input terminals on the SP4-LOC terminal block and by switching ON the DIP switches on switch block SW7 positions 1 through 8. 9. Connect the SPRM to the SP40. Figure 6 shows the proper wiring connections for the SPRM to the SP40/2. Figure 7 shows the proper wiring connections for the SPRM to the SP40S.

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 11 REMOTE MICROPHONE SP40/2 PANEL AUDIO OUT AUX IN CC/NAC + - + - TB6 24VDC RM AUDIO STATUS (CC) - + - + 654321 + - + - + - + + - - IN BAT 24V Figure 6. Wiring Diagram SPRM to SP40/2 This wiring is power limited. REMOTE MICROPHONE SP40S PANEL 24V OUT AUX CC/NAC + - + - TB6 24VDC RM AUDIO STATUS (CC) - + - + 654321 + - + - Figure 7. Wiring Diagram SPRM to SP40S This wiring is power limited. 10. Mount the INNER DOOR to the backbox using the four #8-32 truss head screws and plastic washers. 11. Mo

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 12 MASS NOTIFICATION SYSTEM 1/8" SECURITY WIRE HOLES SLAM LATCH #8-32 X 3/4" STUDS (8) ON BACK OF FRONT RING 1/2" TRIM RING ON FLUSH MOUNT MODEL FRONT RING Figure 8. Front Door Layout Operating Instructions: SP40/2 Panel _ _ + _ + + TB6 AUX IN AUX CC/NAC AUX IN NAC CC W5 W4 SW4 100V 70V 25V 1V AUDIO OUT AUXILIARY INPUT SELECTION JUMPER J4. SELECT 1V POSITION CC/NAC SWITCH SW4 PLACE IN CC POSITION AUXILIARY INPUT SUPERVISION JUMPER W5. REMOVE FOR SUPERVISION. Figure 9. Switch locations on the SP40/2 for SPRM

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 13 Figure 9 shows the locations of the switches and LED’s on the SP40/2 that are required for SPRM operation. 1. Set the NAC/CC switch (SW4) on the SP40/2 PC board to the CC position. 2. Set the AUX IN jumper J2 to the 1V position. 3. Remove AUX SUP jumper (W5). 4. Install a UL Listed 10K Ohm End of Line Resistor (EOLR) on the AUX IN of SP40/2. SP40S Panel _ _ + _ + + TB6 AUX CC/NAC 24V OUT CC/NAC SW6 100V 70V 25V 1V J4 AUX IN AUX SUP JP4 SP40S CC/NAC SWITCH SW6 PLACE IN CC POSITION AUXILIARY INPUT SELECTION JUMPER J4. SELECT 1V POSITION AUXILIARY INPUT SUPERVISION JUMPER JP4. REMOVE FOR SUPERVISION. Figure 10. Switch a

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 14 HVAC SHUTO FF 1 2 1 2 3 5 4 3 MASS NOTIFICATION SYSTEM 4 INNER PANEL BACK BOX FRONT DOOR ASSEMBLY 5 6 6 7 7 (SURFACE AND FLUSH) 8 SYSTEM MASS NOTIFICATION 8 PARTS LEGEND: ELECTRICAL CONDUIT AND FIELD WIRES. (1/2" AND 3/4" KNOCKOUTS PROVIDED ON TOP, BOTTOM AND BACK FACE.) SP4-LOC BACKBOX ORIENTATION LABEL #8-32 TRUSS HEAD (4) INNER PANEL MOUNTING SCREW TERMINAL STRIP AND WIRING HARNESS 1/4" DIAMETER HOLE (6) TO ACCEPT #8-32 STUDS FROM FRONT DOOR PANEL. #8-32 SEMS NUT (6) PROVIDED. OPTIONAL "HVAC SHUTOFF" LABEL AND MUSHROOM HEAD PUSHBUTTON SWITCH 1/8" HOLES (2) FOR

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 15 Warranty Limited Warranty Cooper Wheelock, Inc. products must be used within their published specifications and must be PROPERLY specified, applied, installed, operated, maintained, and operationally tested in accordance with these instructions at the time of installation and at least twice a year or more often in accordance with local, state and federal codes, regulations and laws. Specification, application, installation, operation, maintenance, and testing must be performed by qualified personnel for proper operati

  • Cooper Wheelock SAFEPATH4 SP4-LOC, 16 foregoing shall constitute the sole remedy of the purchaser and the exclusive liability of Cooper Wheelock, Inc. In no case will Cooper Wheelock, Inc.'s liability exceed the purchase price paid for a product. Limitation of Liability Cooper Wheelock, Inc.'s liability on any claim of any kind, including negligence, breach of warranty, or otherwise, for any loss or damage resulting from, arising out of, or connected with any contract, or from the manufacture, sale, delivery, resale, repair or use of any product shall be limited to the price applicable to the product or part thereof

Related Products and Documents (Microphone):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Edge10 H170 Operation & user’s manual edge10/h170-HD8.pdf 24 Apr 2023 17
2 Speco CVC-627 Operation & user’s manual speco/cvc-627-UK6.pdf 02 Apr 2023 16 3.65 Mb
3 Audience ClairAudient 1+1 V1 Owner's manual audience/clairaudient-11-v1-BC1.pdf 31 May 2023 2
4 KitchenAid KBFU271 Installation instructions and use & care manual kitchenaid/kbfu271-B6N.pdf 23 Feb 2024 24
5 HP Z400 Declaration of conformity hp/z400-MS4.pdf 15 Jul 2022 1 0.02 Mb
6 Clarson CarCom Operating instructions clarson/carcom-32K.pdf 13 Mar 2024 2

Similar Resources:

  • Sony

    DWZM70

    (26 pages)
    Digital WirelessPackageOperating InstructionsBefore operating the unit, please read this manual thoroughly and retain it for future reference.Please read this manual together with the manual supplied with the BC-DWZ1.DWZ-M70/B70HL4-460-562-14 (1)© 2012 Sony Corporation …
  • ICON

    M1

    (44 pages)
    1ENGLISHFRANÇAISDEUTSCHEESPAÑOL日本語ITALIANOStudio large-diaphragm condenser microphoneMicrophone à condensateur de studio à large diaphragmeGroßmembran-Kondensatormikrofon für StudioaufnahmenMicrófono de condensador de estudio de diafragma grandeMicrofono a condensatore da studio a diaframma largoスタジオ用大口径ダイアフラム コン� …
  • LTO

    RADIUS 100

    (11 pages)
    User Guide English ( 3 – 11 ) Guía del usuario Español ( 12 – 20 ) Guide d’utilisation Français ( 21 – 29 ) Guida per l’uso Italiano ( 30 – 38 ) Benutzerhandbuch Deutsch ( 39 – 47 ) Gebruikershandleiding Nederlands ( 48 – 56 ) Appendix English ( 58 – 59 ) …
  • CES

    710 DTMF

    (12 pages)
    Page 1Model 710 DTMFProgrammable Microphone ManualCES Wireless Technologies925-122 South Semoran Blvd.Winter Park, FL 32792Tel 407.679.9440 Fax 407.679.8110Email: [email protected]: www.ceswireless.com06000561 REV F MAN08A REV 8/02© CES Wireless Technologies Corp 1991-2002 …
  • Kurzweil

    KM-2U

    (5 pages)
    KM-2U User ManualImportant Safety Instructions• Read the instruction manual carefully and completely before using the product.• Always include the instruction manual when passing the product on to third parties.• Do not use the product if defective or damaged.Power Requirements and Compatibility!The KURZWEIL KM-2U receives power supply from the compute …
  • Sennheiser

    EW 335

    (2 pages)
    • Sturdy metal housing (transmitter & receiver)• PC-supported frequency management for transmitter and receiver• Tunable UHF frequencies within a large switching bandwidth • Wireless microphone with programmable, easy-access MUTE switch• Quick-change microphone head from the e 800 Series • Large range of replaceable microphone heads from the …

Comments, Questions and Opinions: