  • Smoke alarm Installerʼs Manual 240V Interconnectable Main Operated Alarm For models: Q1300 Thank you for purchasing Quell 240V hard-wired photoelectric smoke alarm. Please read through our guide in full. Chubb Fire & Security Pty Limited recommends for maximum protection that both ionisation and photo-electric (optical) smoke alarms be installed. Ionisation sensing alarms may detec

  • Quell Q1300, Contents Section 1. Installation Instructions ................................................1 Section 2. Recommended Locations ............................................2 Section 3. Locations to be Avoided...............................................4 Section 4. Installing Alarm.............................................................6 Section 5. Interconnecting.............................................................7 Section 6. Initial Testing and Checking of Alarm...........................7 Section 7. L.E.D. Status.................................................................8 Section 8. Maintenance.....................

  • Quell Q1300, 1 1. Installation Instructions This alarm is designed for installation by a qualified (licensed) electrician, in accordance with current Building Code of Australia (BCA) Regulations and to any other local or building codes that may apply. • Read these instructions thoroughly before proceeding. Peopleʼs lives depend on it. • This manual is supplied for your guidance and should not be left with the property owner. This is for use by qualified licensed electricians. • AC alarms must be powered by a constant 240V AC, 50Hz supply that is not controll

  • Quell Q1300, 2 2.Recommended Locations • Install the first alarm in the immediate area of the bedrooms. Install additional alarms to monitor the exit path as the bedrooms are usually farthest from the exit. If more than one sleeping area exists, install additional alarms in each sleeping area (Image 1A). • Install additional alarms to protect any stairway as stairways act like chimneys for smoke and heat. • Install at least one alarm on every floor level (Image 1B). • Install an alarm in every bedroom where a smoker sleeps. • Install an alarm in every room where

  • Quell Q1300, 3 Smoke Alarms for Minimum Protection Smoke Alarms for Additional Protection Ionization Type Smoke Alarms with “Hush” Control or Photoelectric Type BEDROOM BASEMENT KITCHEN HALL BEDROOM LIVING ROOM IMAGE 1A IMAGE 1B SINGLE FLOOR PLAN MULTIPLE FLOOR PLAN • Install smoke alarms on sloped, peaked or cathedral ceilings between 500 and 1500mm from the highest point of the ceiling. Smoke alarms in rooms with ceiling slopes greater than 1 m in 8 m horizontally should be located on the high side of the room (See Image 2B) . IMAGE 1C BEDROOM FAMILY ROOM WORKSHOPBASEMENT KITCHEN HALL GARAGE MASTER BEDROOM FIRE EXTINGUISHERS SMOKE ALARMS FIRE BLANKET TOTAL HOME PROTECTION BEDROOM KIT

  • Quell Q1300, 4 3. Locations to be Avoided 3A • Do not install within 0.9 m (3 ft) of the following: The door to a kitchen, or a bathroom that contains a tub or shower, forced air supply ducts used for heating or cooling, ceiling or whole house ventilating fans, or other high air-flow areas. • Do not place the alarm where curtains or other objects will block the sensor. Smoke must be able to reach the sensor to accurately detect conditions. • Install at least 30cm (12 in) away from fluorescent lights as electronic noise may cause nuisance alarms. • Keep out of insect infested areas. Avoid excessively dusty, dirty or greasy areas. Dust particles may cause nuisa

  • Quell Q1300, 5 IMAGE 2A IMAGE 2B CEILING 30 cm (12 in) MINIMUM 10 cm (4 in) MINIMUM 30 cm (12 in) MAXIMUM SIDE WALL BEST PLACEMENT ACCEPTABLE PLACEMENT DO NOT INSTALL DEAD AIR NOT IN THIS AREA ANYWHERE IN THIS AREA NOT IN THIS AREA ANYWHERE IN THIS AREA PEAK CEILING SLOPED CEILING 500mm 1000mm 1000mm 500mm Smoke alarm should be located between 500mm and 1500mm of the highest point. DEAD AIR DEAD AIR DO NOT INSTALL DO NOT INSTALL 1385-7210-02(130413)_Installer.qxd:_ 2013.1

  • Quell Q1300, 6 4. Installing Alarm • These are mains powered alarms, so isolate the mains supply before commencing installation. This alarm is designed for installation by a qualified (licensed) electrician, in accordance with current Building Code of Australia (BCA) Regulations and to any other local or building codes that may apply. • Select suitable location having regard to earlier advice. • Bring house wiring through a dry lining box into back of alarm (illustration a); side entry (illustration b), via mini trunking is also possible by carefully knibbling away edge on trim-plate. Make good joint, with white sealant, if necessary. • If alarm is not being interconnected, interconnec

  • Quell Q1300, 7 6. Initial Testing and Checking of Alarm • Before powering up/testing CHECK THAT WIRING POLARITY is correct and all connections are tight. REVERSING POLARITY will damage all interconnected alarms, and damage is not covered by the Guarantee. Slide alarm fully home on base plate before powering up, to prevent arcing across the contact blades. • Having energised circuit, press and hold the test button – the alarm should sound and other interconnected ones also, within a few seconds. • Do this for all alarms. • If any do

  • Quell Q1300, 7. L.E.D. Status • Green L.E.D. is lit when AC power is present. • Red L.E.D. blinks to indicate normal operation of alarm function (if model with battery back up, also indicates healthy battery). In alarm state (i.e. triggered), L.E.D. will flash rapidly. When interconnected, only triggering alarm will have this state. • If red L.E.D flashes every 10-11 seconds, indicates Hush feature activated (approximately for 7 minutes duration). • If interconnected to other alarms only the triggering ala

  • • Reinstall on alarm base plate affixed to ceiling and push (and hold) test button to verify battery operation. Battery Changing • Reconnect mains supply and check green L.E.D. is lit and red L.E.D. flashes intermittently. GREEN LED RED LED 9 The alarm will not locate without a battery in the compartment Never remove or connect cable harness, without having disconnected mains p

  • Quell Q1300, 1010 10. Repair/Servicing • If the alarm is not functioning, first check the troubleshooting section. If this does not rectify the problem: • Consult your installer, wholesale distributor or landlord for advice if property is rented. • There are no user serviceable parts, except for models with loose batteries. • Do not attempt to dismantle the alarm – this will invalidate the warranty. 11. Limitations of Smoke Alarm Warning! Smoke alarms are devices that can provide early warning of possible fires; however, alarms have sensing limitations. Ionisation sensing alarms may detect invisib

  • Quell Q1300, 11 Although smoke alarms can help save lives by providing an early warning of a fire, they do not prevent property damage. Home owners and renters should have adequate insurance to protect their property. If after reviewing this manual you feel that your smoke alarm is defective in any way, do not tamper with the unit. Refer to Section 11. Contact your Installer, Wholesale Distributor or Landlord. 1385-7210-02(130413)_Installer.qxd:_ 2013.1

  • Quell Q1300, 12. Troubleshooting • Always turn off the mains supply to AC alarms before checking connections etc. . 12 Symptom 1. Green L.E.D. not lit 2. Frequent nuisance alarms 3. Alarm chirps every 30-40 seconds 4. Alarm does not sound when test button pressed and held. 5. Interconnected alarms do not sound when test button is pressed and held. Possible cause/solutions a. Loss of mains power – check at Consumer Unit for Blown Fuse or tripped Circuit Breaker. b. Check cables at back of alarm, are correctly seated /

  • 13 13. Warranty & Contact Details TEN YEAR LIMITED WARRANTY Warranty Chubb warrants to the original consumer purchaser that each new smoke alarm will be free from defects in materials and workmanship under normal use for a period of 10 years from the date of purchase. To the extent permitted by law, Chubb agrees to repair or replace (at our discretion) any defective prod

  • Quell Q1300, AS 3786 Lic 1377 SAI Global This warranty is provided by: Chubb Fire & Security Pty Ltd ABN 47 000 067 541 A UTC Climate, Controls & Security Company 149-155 Milton Street, Ashfield NSW 2131 Australia Telephone: 1800 654 435 Website: www.quell.com.au Chubb New Zealand Limited A UTC Climate, Controls & Security Company 3 Fisher Crescent, Mt Wellington, Auckland, New Zealand Telephone: 09 270 7288 Website: www.quell.co.nz 14 To make a claim If a defect in the product appears within the time frame stated, you are entitled to submit a warranty claim by returning your product to the address shown below. Please conta

More Instructions:

DOWNLOAD

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Toshiba Equium 5160D Preliminary maintenance manual toshiba/equium-5160d-P1S.pdf 21 Jun 2023 194
2 Euroclean GD 930-HSP Specifications euroclean/gd-930-hsp-IXP.pdf 15 Dec 2023 2 0.34 Mb
3 Velodyne FSX-12 Owner's manual velodyne/fsx-12-7QW.pdf 15 Jul 2023 6 0.07 Mb
4 Panasonic KX-TG5971AL Operating instructions manual panasonic/kx-tg5971al-3D7.pdf 04 Dec 2023 84 3.26 Mb
5 Curtis HTIB1002 Product features curtis/htib1002-R7I.pdf 23 Sep 2022 1 0.33 Mb
6 Vialta VISTAFRAME VF-100 Operation & user’s manual vialta/vistaframe-vf-100-DES.pdf 20 Dec 2022 42 1.51 Mb

Similar Resources:

  • Cooper Wheelock

    XB12

    (2 pages)
    Description:These high output certified strobes have been designed for use in potentially explosive atmospheres and harsh environmental conditions. The enclosures are suitable for use offshore or onshore, where light weight combined with corrosion resistance is required.The strobe housing is manufactured completely from a U.V. stable, glass reinforced poly …
  • FCI

    ADP-R

    (4 pages)
    FC200-12-00 8 I56-2214-004R© 2004 FCIFCC StatementThis device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may no …
  • Cavius

    2106-003

    (2 pages)
    The red LED will light up to indicate that ‘Learn Mode’ has been selected. Please note that when the alarms are placed in ‘Learn Mode’ they can’t be inserted into the mounting base. Do not take out the battery during ‘Learn Mode’ as this will interrupt the learn process. Press and hold the test button at one alarm only, until it beeps and the L …
  • Teletek electronics

    SensoIRIS S130

    (2 pages)
    SensoIRIS S130ATTENTION: Read carefully this installation Instructions before installing the device! This manual is subject to change without notice! SensoIRIS S130 is аn addressable optical-smoke detector designed for installing in addressable fire alarm systems supporting TTE communication protocol. The detector is powered on from the panel and can be co …
  • GST

    DC-M9103

    (2 pages)
    30309579 Issue 1.05 Features  Reed switch testing.  Output terminal for remote indicator available.  Rate of rise and fixed temperature, and fixed temperature programmable. …
  • Wheelock

    MTH-24

    (5 pages)
    P81543 G Sheet 1 of 5 273 Branchport Avenue Long Branch, NJ 07740 (800) 631-2148 Thank you for using our products. www.wheelockinc.com INSTALLATION INSTRUCTIONS MULTI-TONE HORN Use this product according to this instruction manual. Please keep this instruction manual for future reference. MODEL NUMBER: MTH-24 GENERAL: The MTH-24 Mult …

Comments, Questions and Opinions: