  • Avitech Rainier-4a, 3. Click to select the COM checkbox and on the drop-down menu, select the correct COM port number. grading the firmware on the ID drop-down menu. 5. Click to select the FPGA UB checkbox, and then click the Browse button to specify the location of the firmware file and select “AT-Rainier4x1v-UBFPGA.rbf.” 4. Select the correct ID number of the corresponding Rainier you are up 6. Click the Update button located on the left lower portion of the screen. 7. Reboot (unplug and re-plug th

  • One Module Per Group By default, the Galaxy software will combine all available modules into one large group. To quickly divide modules into different groups, each module can be treated as a group. For example, if cascading four modules, it will divide into four groups. When the next screen appears, click OK to finalize the changes. The configuration progress will be shown on the

  • Avitech Rainier-4a, Parts Specifications Power supply Less than 30 watts 100 – 240 V, 50 / 60 Hz (external) 12 V DC Housing Metal Dimension (W×D×H) 1/2 rack 209.6×271.8×44.5 mm (8.25×10.7×1.75 inch) Two can be mounted side-by-side in 1 RU Weight 2.3 kg (5 lbs) Temperature Environment Operating: 0 °C (32 °F) to 40 °C (104 °F) Storage: –10 °C (–4 °F) to 50 °C (122 °F) Humidity 0 % to 80 % relative, non-condensing Safety regulations FCC / CE / C-Tick, Class A Operating Features z Standalone operation (single Rainier) with control via RS-232 cable or; multiple operations (up to four Rainier – three DVI). z Two Rainier can fit in a single rack unit space for a maxim

  • Avitech Rainier-4a, Galaxy Control Window Select Menu Open Option Menu This toggles the Option window display on / off. Dock Option Menu This returns the Option window display to its default position on the right side of the Galaxy control window. This option is not available (grayed-out) if the previous item Open Option Menu is disabled. Settings Menu 16

  • Avitech Rainier-4a, 3. To switch between the different groups, use the Group drop-down menu. 4. Exit the Galaxy software and select Yes when prompted to save to flash memory Save System Files to Flash This allows you to save all configuration settings to flash memory. If the system configuration has been changed, save the changes first before continuing the other configuration settings. The progress of saving to flash memory will be displayed. 28

  • Avitech Rainier-4a, Select Source This allows you to copy the input signal source from one process window (e.g., Window 1) to another process window (e.g., Window 2), within the same module only. Window 2 will then display the same image as Window 1. Right-click the mouse on a particular window, then click Select Source. The following menu appears. The selected source has a checkmark. Check Signal To determine if the video signal is being fed into the selected window, right-click the mouse on a particular window and click Check Signal. The

  • For cascaded modules NOTE: Make sure the cascaded modules have different rotary ID settings (e.g., 1 – 2 – 3 – 4) on their rear panels. 4. Click OK and the following screens appear: Module Layout window, Galaxy control window, and Option window. For standalone module 13

  • Avitech Rainier-4a, For an Individual Window 1. Right-click the mouse on a window and select Label to enter text. NOTE: DVI input does not display a label. 2. Keep in mind that each window supports one line of text (up to 32 characters). 35

  • Avitech Rainier-4a, 2. Ensure that Enable is selected (with checkmark). If it is unchecked, only static labels will be displayed. 3. Specify the Display Address (ranges from 0 to 126). The address should match the TSL controller configured address corresponding to the router output feeding the corresponding Avitech input. NOTE: Use the mouse to right-click each individual window to set the TSL Display Address. 4. If you want to display dynamic labels, click the radio button to select TSL Only. If you want to display both the static and dynamic labels, click the radio button to select Al

  • z Automatically Backup Files to Hard Drive By default, the Galaxy software will save all backup files to the C:\Avitech_VCC\BackUp\ folder. You may change this by clicking Browse to select a different location to save the backup information. z No Signal Size Refer to When the window is unable to detect a signal, this will serve as the basis for the Galaxy software

  • Avitech Rainier-4a, 4. After successfully installing the device driver, the computer can now detect the USB-to-serial converter device name. To check, click StartÆControl Panel erties screen appears, sel ger button. . Double-click the System icon and when the System Prop ect the Hardware tab and then click the Device Mana 95

  • Avitech Rainier-4a, Activating Tally The RJ-50-to-GPI terminal block allows for a total of eight inputs to activate tally, two per window. You can also use the serial port with ASCII, TSI, or TSL to activate tally. To change the appearance of tally, perform the following steps: 1. Select SettingsÆModule ParameterÆTally. The following window appears: Tally 1 and 2 are triggered by GPIO while Tally 3 is triggered via serial communication. 2. The settings that can be adjusted include Tally Color, LED, Label, Border, and Flash. 46

  • Avitech Rainier-4a, 3 Avitech ASCII Protocol The Rainier supports th pt interface. You can use HyperTerminal to control RS-232) on the Rainier can also be used to interface with a controller for control over RS-232. This chapter fami the Avitech ASCII Protocol (AAP) of the Rainier via Microsoft Windows HyperTerminal function as an example. 3.1 Setting the RS-232 Port Before using the ASCII Z command interface, make sure that the COM A o parity, and mber for e ASCII command prom your Rainier. The serial port ( third-party liarizes you

  • Avitech Rainier-4a, Regulatory Information NOTE: Marking labels located on the exterior of your device indicate the regulations that your model complies with. Please check the marking labels on your device and refer to the corresponding statements in this chapter. Some notices apply to specific models only. Federal Communications Commission (FCC) Statement This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful inter

  • Avitech Rainier-4a, 7. Connect the AC power cord to the 100-250V AC power jack. Cascading NOTE: Video cascading not applicable for the Rainier-4a / 4d models. To cascade two or more Avitech Rainier, perform the following steps: 1. Set the rotary ID on the first Avitech Rainier (Master module) to 0, set the rotary ID on the second Avitech Rainier to 1, set the rotary ID on the third Avitech Rainier to 2, and so forth (can be other values as long as both are different from each other’s setting). 2. Connect one end of the DVI cascading cable to the DVI-I Output port of Rainier ID 0 (Master module) and the other end

  • 7. Make sure that the COM Port Number is set to COM1, and then click OK. A.2 Updating the Firmware The firmware for Rainier is divided into: z Rainier 4x1V firmware z FPGA firmware (for Rainier-4d / 4d1V only) IMPORTANT: If you need to update both firmware, make sure to perform Rainier 4x1V firmware update first. Rainier 4x1V Firmware To update

  • Avitech Rainier-4a, 3. If the backup content is somewhere else other than at the C:\Avitech_VCC\Backup\IP or RS-232\xxxx#_#, copy the backup data from xxxx#_# into the C:\Avitech_VCC\Backup\IP or RS-232\xxxx#_# location. 4. Run the Galaxy software and select Yes when prompted whether to restore the module using the backup data. 5. Click Help, and then click Restore Module Information. You should see a progress bar showing the preset being loaded into the Rainier. 6. When the following screen appears, the checking result confirms that everything is normal. If that is the case, click Ca

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Frigidaire FEX831C Factory parts catalog frigidaire/fex831c-3W3.pdf 06 Jul 2022 14 0.75 Mb
2 Sharp ER-A347 Manuel d'instructions sharp/er-a347-NZK.pdf 21 Jul 2023 115 22.97 Mb
3 Yamaha PZ50RTX Owner's manual yamaha/pz50rtx-257.pdf 24 Jul 2022 92 8.06 Mb
4 Beckett Accent Lighting LT20 Product features beckett/accent-lighting-lt20-JWW.pdf 09 Aug 2022 1 0.34 Mb
5 Behringer XENYX X1832USB Quick start manual behringer/xenyx-x1832usb-3ZN.pdf 07 Jan 2024 21 7.46 Mb
6 Olympus PT-EP05L Instruction manual olympus/pt-ep05l-PK5.pdf 17 Jun 2022 27

Similar Resources:

  • Lorex

    VANTAGE LH110 ECO SERIES

    (3 pages)
    1www.lorextechnology.comCopyright © 2011 Lorex Technology LH110 Series DVR: Frequently Asked QuestionsWhen connected to a VGA monitor, why can’t I see a mouse cursor, or access the system menus by using the front panel controls of the DVR?Solution 1You may have accidently switched the system output by pressing the 0 button on theremote; or the DVR did not …
  • QOLSYS

    IQ Hardwire 16

    (2 pages)
    1. Mount the IQ Hardwire 16 vertically in your desired location. 2. Install provided antenna into the “ANT” terminal at the top of the unit free from obstructions3. Wire all hardwired sensors/leads into the terminals marked “Zone 1-16”a. All sensors must have a resistor installed between 1k-10k Ohm in either the N/O or N/C positionb. Wire the Positi …
  • Eaton

    Crouse-hinds series

    (12 pages)
    Explosionsgeschützte Deckeneinbauleuchten eLLB 20.. /eLLB 20.. V-CG-SExplosion Protected Recessed Ceiling light fittings eLLB 20.. /eLLB 20.. V-CG-SLuminaires dans le plafond pour atmosphères explosives eLLB 20.. /eLLB 20.. V-CG-SBetriebsanleitungOperating instructionsMode d’emploi300 8000 1447 D/GB/F (m)CROUSE-HINDSSERIESIEC 60079-7: 2014 …
  • SYLCO

    ECO 560

    (20 pages)
    the sound of securityECO 560/500N54539-Z134-A100SELBSTVERSORGTER OPTISCH-AKUSTISCHER AUSSENBEREICH SIGNALGEBERDISPOSITIF SONORE D’ALARME AUTO-ALIMENTÉ POUR USAGE À L’EXTÉRIEURSELF-POWERED OUTDOOR ACOUSTIC ALARM DEVICEFRDE EN …
  • GRI

    DA-1

    (2 pages)
    GEORGE RISK INDUSTRIES, INC.G.R.I. PLAZAKIMBALL, NE 69145MADE IN U.S.A.TOLL-FREE 1-800-445-5218TOLL-FREE 1-800-523-1227(308) 235-4645FAX (308) 235-3561E-MAIL: [email protected] SITE: www.grisk.com Sounds Instantly When Door Opens Choice Of 2, 4 or 6 Second Sounding Time Choice Of Three Volume Settings Remote Sounders Available Mo …
  • Lorex

    LHB900 Series

    (2 pages)
    HD Wire-Free Security SystemEnglish Version 5.0Quick Reference Guidewww.lorextechnology.comLorex Secure: App OverviewBefore You StartLHB900_QRG_EN_R5Lorex Secure: PlaybackGUIDE2 / 2• Upgrade your DVR firmware and mobile app to the latest versions. • Please note that an upload speed of 3 Mbps is required for remote video streaming. Up to 3 devices may …

Comments, Questions and Opinions: