Secutron MR-2300 series Installation & Operation Manual

  • MR-2300 series Smoke Alarm
  • maafGtjl5hx2E
  • Installation & Operation Manual
  • PDF / Adobe Acrobat Reader
  • 84

Secutron MR-2300 series Manual Online:

3.4, 805 votes
Secutron MR-2300 series User Manual
Secutron MR-2300 series User Guide
Secutron MR-2300 series Online Manual

Text of Secutron MR-2300 series User Guide:

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 17 Programming the relays A typical relay circuit is shown below in Figure 10 with the jumper locations and descriptions. Figure 10: MR-2312/06-R12/6 Relay programming MR-2306-R6 Six Relay Adder Module Cable from P1 of the MR-2306-R6 is connected to P6 on the Main Fire Alarm Board. The jumpers located above each relay on the MR-2306-R6 are used to configure the relays. The jumpers located below the relays are used to select either normally open contacts or normally closed contacts. Figure 11: MR-2306-R6 six relay adder module P1: Cable from

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 59 11. Bypass Det Ckt (Command-Menu) 12. Bypass NAC Ckt (Command-Menu) 13. Aux. Disconnect (Command-Menu) Note: Refer to How to Use the Keypad to Program the MR-2300 on page 39 for detailed instructions on making menu selections. Initiating zones may be bypassed individually. This bypass command will allow you to scroll through all initiating zones 1 to a maximum of 12 depending on the size of the panel. Press Enter to bypass the zone or scroll up or down to un-bypassed (normal connected circuit). Press Enter to un-bypa

  • Secutron MR-2300 series, Configuration 46 2. Config Info (Command-Menu) Note: Refer to How to Use the Keypad to Program the MR-2300 on page 39 for detailed instructions on making menu selections. Press down arrow key to see more information. Configuration type will show how the panel was configured. “Factory default” means the panel has not been configured, it is as it came from the factory. “Front Panel” means it was configured at the panel. “Serial Port” means the configuration was done from a computer through the serial port. “Modem” means the configuration was completed remotely through a modem. If you upload a job configuration to the panel using the PC configuration utility

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 15 MR-2300-A Input Class-A Converter Adder Module Figure 7: MR-2300-A Input Class-A Converter Adder Module There are no jumpers or cables to set on this module, just wiring from the converter (wires are fixed here) to the Main Fire Alarm Board. Initiating circuits must be wired from the MR-2300-A module to the Main Fire Alarm board. For example, Initiating circuit 1 positive (red) and negative (black) wires are connected to the positive and negative terminals (respectively) of Initiating circuit 1 on the Main Fire Alarm Board. From the MR-2300-A converter Initiating circuits are wired out to the

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 49 6. Clear Event Log (Command-Menu) Note: Refer to How to Use the Keypad to Program the MR-2300 on page 39 for detailed instructions on making menu selections. Select the type of log to clear. Press the “ENTER” key. The system will then confirm before clearing logs. Press the “ENTER” key to confirm or the “CANCEL” key to cancel the operation. Use this function to clear alarm logs, general logs, or both. -Select Log- 1 Alarm Log 2 General Log 3 All Logs Clear all the selected log(s)? Y

  • Secutron MR-2300 series, Configuration 40 Command Menu/MR-2300 Config/ Features/ 5.Aux. disconnect, disconnects Aux Alarm relay and all correlated relays [ ] ENABLE [X] DISABLE->Default In the default mode this function will disconnect the Auxiliary Alarm Relay when selected by Command Menu, Item 12 which acts like an Aux. disconnect switch. If enabled, this function will disconnect the Auxiliary Alarm relay and all correlated relays when selected by Command Menu, Item 12 which acts like an Aux. disconnect switch. Correlated relays include: MR-2312-R12/2306-R6 relays, MR-2312-S12 relays. Command Menu/MR-2300 Config/ Features/

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 61 AC Power Fail The AC power fail trouble is generated when the power drops below the UL specified value. The trouble is restored when the power returns to the normal value. Battery trouble The battery trouble is generated when the battery voltage drops below the specified UL value. The trouble is restored when the voltage returns to the normal value. Ground Fault Note: The trouble code and info is for trained service personnel only. AC Power Fail Active 1/ 1 Trb:0x03 Info:0x0004

  • Supported Protocols/Devices 34 Supported Protocols/Devices Synchronous Strobes The synchronous strobe models that are supported by the MR-2300 panel include Secutron models MRL-ST and MRA-HS. A separate compatibility list is available for different supported models. Strobes can be configures as normal (e.g. not synchronized or any of the above; see configuration sec

  • Secutron MR-2300 series, Warranty & Warning Information 74 Limited Warranty Secutron Inc. warrants the original purchaser that for a period of two years from the date of manufacture, the product shall be free of defects in materials and workmanship under normal use. During the warranty period, Secutron Inc. shall, at its option, repair or replace any defective product upon return of the product to its factory, at no charge for labor and materials. Any replacement and/or repaired parts are warranted for the remainder o

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 39 How to Use the Keypad to Program the MR-2300 1. Press MENU to enter the command menu. 2. Select a Command Menu option by pressing ENTER. The corresponding submenu will display. 3. Use the up and down arrow buttons to scroll through the submenu. 4. Press ENTER to select a submenu option. 5. Use the left or right arrow buttons to select/unselect an option (selected = “X ”). Use the up and down arrows to scroll through the different options. 6. Once you have made the correct selection, press ENTER to confirm the change. The display

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 43 Command Menu-->MR-2300 Config Opt Zone This menu is used to program the process type of the indicating circuits. The maximum number of indicating circuits is four, but only those supported by the particular model will be shown. Command Menu-->MR-2300 Config Correlation Note: Refer to How to Use the Keypad to Program the MR-2300 on page 39 for detailed instructions on making menu selections. Command Menu/MR-2300 Config/Opt. Zone 1. Type (Indicating Circuits) 4. [X] SIL-ABLE->Default [ ] NON SIL-ABLE [ ] SIL-ABLE STR [ ] NON-SIL STR Use this function to p

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 31 Circuit Types Initiating (Detection) Circuit Types Non-Verified Alarm A Non-Verified alarm is a “normal” type of alarm that can have pull stations, smoke detectors, or heat detectors attached to it. Activation of any of these devices will immediately result in an alarm condition in the Fire Alarm Control Panel. An Alarm condition causes the Common Alarm LED to illuminate red. Verified Alarm Verified Alarms are verified by a reset and timing procedure, an

  • Secutron MR-2300 series, Configuration 56 Command Menu-->Dialer-Config Time Parameters Command Menu/Dialer-Config/Report Options 6.Dialer operation mode [X] (U)DACT ->Default [ ] DACT Use this function to select the functionality of the dialer. In DACT mode only common trouble/alarm/supervisory are reported while in UDACT mode all point information is reported Command Menu/Dialer-Config/Report Options 7.Checksum Bits [X] 8 Bit ->Default [ ] 16 Bits Do not change this function; keep it as default For factory use only. Note: Refer to How to Use the Keypad to Program the MR-2300 on page 39 for detailed instructions on making menu selectio

  • Secutron MR-2300 series, Indicators, Controls and Operations 28 Indicators, Controls and Operations Refer to Figure 23 below which shows the LCD Display, the Keypad and Control Button locations. Figure 23: LCD Display and control buttons The Main Display Panel on the Main Fire Alarm Control Board consists of: • 5 common LED Indicators (under the LCD display) • 5 Common Buttons (column left of key pad) LED Indicators may be Amber, Red, or Green, and may illuminate continuously (steady), or at one of two Flash Rates. • Fast Flash (Supervisory) - 120 flashes per minute, 50% duty cycle • Trouble Flash (Trouble) - 20 flashes per minute, 50% duty cycle SYST

  • MR-2300 Series LCD Version Installation and Operation Manual 23 Relay Adder Module Wiring Wire relays on the relay adder modules MR-2312-R12 and MR-2306-R6 as shown in Figures 19 and 20. Figure 19: Relay per zone (MR-2312-R12) Terminal connection Figure 20: Relay per zone (MR-2306-R6) Terminal connection C C NO/NC NO/NC C NO/NC ALL RELAY CONTACTS 28V DC, 1 AMP RESISTIVE LOAD RM-312

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 7 Output Class A converter: four circuits Output Class A converter: two circuits Active end-of-line The MR-2300-X are power-saving End-of-Line resistors that eliminate the need for an additional battery cabinet or larger batteries in order to meet the 60 hour standby requirement. MR-2312-AT Remote Annunciator Additional Fire Alarm System Accessories Model: MR-2306-ATR/MR-2306-ATW Eight Zone Remote Annunciator (ULC and ULI Approved) Model: MR-230

  • Secutron MR-2300 series, Configuration 62 Remote Annunciator Troubles related to the annunciator can have two possibilities: either the main panel and annunciator failed to communicate with each other, or an unconfigured remote annunciator is responding to the main panel. In both the cases, the following trouble message is displayed: Four-wire smoke detector supply The four-wire smoke detector supply is supervised for shorts. When a short is detected on the four-wire smoke supply the power is cut off and a trouble message is generated. Press the system “RESET” key to restore power to the system. If the short is removed, the panel will return t

  • Secutron MR-2300 series, Introduction 2 Introduction Secutron's MR-2300 Series Fire Alarm Control Panel is a Digital Signal Processor (DSP) based fire panel. The MR- 2300 provides a maximum of 12 supervised Class B or A (Style B or D) Initiating circuits, and maximum of four supervised Class B or A (Style Y or Z) indicating circuits. All circuits are supervised for opens and ground faults, and indicating circuits are supervised for shorts. Optional modules include Relay, Polarity Reversal and City Tie and Class A Converters for initiating and indicating circuits. Semi-flush or surface mountable enclosures can be used for retrofits and on new i

  • Secutron MR-2300 series, Warranty & Warning Information 72 Warranty & Warning Information Warning Please Read Carefully Note to End Users: This equipment is subject to terms and conditions of sale as follows: Note to Installers This warning contains vital information. As the only individual in contact with system users, it is your responsibility to bring each item in this warning to the attention of the users of this system. Failure to properly inform system end- users of the circumstances in which the system might fail may result in over-reliance upon the system. As a result, it i

  • MR-2300 Series LCD Version Installation and Operation Manual 19 Field wiring Main Fire Alarm Board Field Wiring Wire devices to the terminals as shown in the figures that follow. Refer to the Wiring Tables for wire gauges and to Appendix A for specifications. Initiating Circuit Wiring Wiring diagrams for the initiating circuits are shown below. The panel supports Style B wiring or

  • Appendix B: Reporting 66 Appendix B: Reporting Ademco Contact-ID MR-2300 Event Codes NNN-Refers to Sensor number for zone causing event. Event Description Event Family Qualifier Code Group # Contact # Phone Line #1 trouble detected Trouble New event 1 351 00 000 Phone Line #2 trouble detected Trouble New event 1 352 00 000 Phone Line #1 trouble restored Trouble Restore 3 351 00 000 Phone Line #2

  • Secutron MR-2300 series, MR-2300 Series LCD Version Installation and Operation Manual 3 Conventions Circuits Refers to an actual electrical interface for Initiating (Detection) and Indicating (Signal) or Relays. Zone Is a logical concept for a Fire Alarm Protected Area, and will consist of at least one Circuit. Often the terms Zone and Circuit are used interchangeably, but in this Manual the term Circuit is used. Events There are events associated with every initiating, indicating and common circuit of the fire panel displayed via the LCD. Wiring Styles Initiating and indicating circuits are Class B (Style B and Y). Changing the initiating circuits to Class A

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Mitsubishi Electric LDT323V Operation & user’s manual mitsubishi-electric/ldt323v-VS4.pdf 29 Nov 2022 48
2 VTech V.Smile Baby Care Bears Play Day Operation & user’s manual vtech/v-smile-baby-care-bears-play-day-56D.pdf 11 Apr 2023 12 3.22 Mb
3 Samsung TS-H292A Operation & user’s manual samsung/ts-h292a-95I.pdf 12 May 2023 24 3.03 Mb
4 Rotel RKB-2100 Owner's manual rotel/rkb-2100-X3V.pdf 04 Aug 2023 56 1.97 Mb
5 IKEA Haftigt Instruction manual ikea/haftigt-S7M.pdf 19 Jul 2023 28
6 JVC Micro Component System UX-S11 Instructions manual jvc/micro-component-system-ux-s11-XM8.pdf 24 Oct 2023 74

Similar Resources:

  • LST

    1151EIS

    (1 pages)
    © LABOR STRAUSS SICHERUNGSANLAGENBAU GMBH • A-1231 WIEN • WIEGELESTRASSE 36 • TEL +43 1 52114-0 • FAX +43 1 [email protected] • WWW.LST.AT • ALL RIGHTS RESERVED1151EIS_DBL_LST_EN_0804.PDF • PAGE 1ABuilding Safety. Building Security.IS Ionisation Smoke Detector1151EIS for Hazardous AreasDescriptionSpecifi cationsThe Intrinsically Safe I …
  • Landmann

    3875GWLACR

    (29 pages)
    ASSEMBLER / INSTALLER:Leave these instructions with the consumer.CONSUMER / USER:This instruction manual contains important information necessary for the proper assemblyand safe use of this appliance. Read and follow all warnings and instructions before assembling and using this appliance. Follow all warnings and instructions when using this appliance. Ke …
  • System Sensor

    A310E

    (17 pages)
    1© System Sensor 2008 I56-2634-004ENPittway Tecnologica S.r.l, Via Caboto 19/3, 34147 Trieste, ItalyDEUTSCHENGLISHINSTALLATION AND MAINTENANCE INSTRUCTIONSA300 SERIES ASPIRATED SMOKE DETECTORshould be monitored using a separate monitor module toreturn the fault.A300E Series smoke detectors are powered by an external24Vdc power supply.With the use of an exh …
  • Polon-Alfa

    ADR-20N

    (7 pages)
    ADR‐20NSELF‐CONTAINEDOPTICALSMOKEDETECTORInstallationandMaintenanceManualIK‐E289‐003GBIssue1A …
  • System Sensor

    BEAM1224A

    (18 pages)
    INSTALLATION AND MAINTENANCE INSTRUCTIONSBEAM1224A, BEAM1224SASingle-ended Reflected Type Projected Beam Smoke DetectorD400-73-00 1 I56-2541-00RSpecificationsGeneralRange: 16 to 230 Feet (5 to 70m) 230 to 328 Feet (70 to 100m) using optional accessory BEAMLRKSensitivity: 25% to 50% Total Obscuration in 6 levels Level 1 = 25% Level 2 = 3 …
  • usi

    MICN109CN

    (18 pages)
    PLEASE READ AND SAVE!THANK YOU for purchasing this combination alarm. This manual includes important information regardingwhere to install the alarm, how to operate, maintenance, testing and product features. It also includes tipsand information which could help protect you and your family.MODEL MICN102CN, MICN102LCNIONIZATION SMOKE & FIRE ALARM,CARBON M …

Comments, Questions and Opinions: