Manualios.com

Sidewinder 5000 ESP Installation Manual

Sidewinder 5000 ESP Manual Online:

3.2, 2263 votes
Sidewinder 5000 ESP User Manual
Sidewinder 5000 ESP User Guide
Sidewinder 5000 ESP Online Manual

Text of Sidewinder 5000 ESP User Guide:

  • © 2000 Directed Electronics, Inc. Vista, CA 31 ■ System will not passively arm until it is remotely armed and then disarmed: Are the door inputs connected? Is a blue wire connected to the door trigger wire in the vehicle? Either the green H1/5 or the violet H1/7 should be used instead. ■ Door input does not respond with the progressive trigger, but with immediate full alarm: Wha

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 27 multi-level security arming Multi-Level Security Arming is a feature that allows you to select which of the security system's inputs or sensors will be active and which will be bypassed at the time that the system is armed. (See Table of Zones section in this guide.) Pressing the arm button (only on a Expanded Configuration transmitter) again within five seconds of arming the security system will activate the Multi-Level Security Arming feature. Each time the arm button is

  • Sidewinder 5000 ESP, 12 © 2000 Directed Electronics, Inc. Vista, CA Door locks are controlled by an electrically activated vacuum pump. Some Mercedes and Audi models use a Type D system. Test by locking doors from the passenger key cylinder. If all the doors lock, the vehicle's door lock system can be controlled with just two relays (optional). The control wire can be found in either kick panel and will show (+)12V when doors are unlocked and (-) ground when doors are locked. To interface, see diagram below. The system must be programmed for 3.5 second door lock pulses. (See System Features Learn Routine section of this guide.) This system usually requires a negative pulse to unlock,

  • Sidewinder 5000 ESP, 8 © 2000 Directed Electronics, Inc. Vista, CA door lock harness (H2), 3-pin connector ______ ______ ______ This system can control two common power door lock types without any additional parts! With certain vehicles, or if an actuator is to be installed, either a p/n 451M Door Lock Relay Satellite or two relays will be required. IMPORTANT! If you mistake a Type C direct-wired system for a Type A positive-pulse system, the module will be damaged! door lock wiring guide The system can control a Type A system directly, with no additional parts. The switch will

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 17 internal programming jumper This jumper is used to determine the light flash output. In the (+) position, the on-board relay is enabled and the unit will output (+)12V on the WHITE wire, H1/2. In the (-) position, the on-board relay is disabled. The WHITE wire, H1/2, will supply a 200 mA (-) output suitable for driving factory parking light relays. bypassing sensor inputs There are times when you need to temporarily bypass all sensor inputs to the unit, such as when remote start- ing the vehicle. Anytime an auxiliary channel output is us

  • Sidewinder 5000 ESP, 10 © 2000 Directed Electronics, Inc. Vista, CA Interfacing with a reversing polarity system requires either two relays or one 451M (not included). It is critical to identify the proper wires and locate the master switch to interface properly. Locate wires that show voltage on lock and unlock. Cut one of the suspect wires and check operation of the locks from both switches. If one switch loses operation in both directions and the other switch operates in one direction only, you have located one of the target wires. The switch that lost all o

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 21 feature descriptions The features of the system are described below. Features that have additional settings that can be selected only when programming with the PC interface or Bitwriter are indicated by the following icon: 1-1 ACTIVE/PASSIVE ARMING: When active arming is selected, the system will only arm when the transmitter is used. When set to passive, the system will arm automatically 30 seconds after the last door is closed. To alert the consumer of passive arming, the siren will chirp 20 seconds after the door is closed. This provides the con- sumer with an audible warnin

  • Sidewinder 5000 ESP, 28 © 2000 Directed Electronics, Inc. Vista, CA rapid resume logic The Rapid Resume Logic feature ensures that when the security system is powered back up after power has been disconnected, the system will resume the same state it was in before power was lost. For example, if power is disconnected during a full trigger sequence, the system will still be in the full trigger sequence when power is reconnected to the unit. If power is disconnected while the unit is disarmed, it will still be disarmed when power is restored. This also applies to the VRS sequence. If the unit loses power at any time during the VRS s

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 3 primary harness (H1), 12-pin connector ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ ______ This guide describes in detail the connection of each wire. Also included are possible applications of each wire. This system was designed with the ultimate in flexibility and security in mind. Many of the wires have more than one possible function. Please read the instructions carefully to ensure a thorough understanding of this unit and how it operates. H1/1 ORANGE (-) GROUND-WHEN-ARMED OUTPUT This wire supplies a (-) ground as long as the system is armed. This output ce

  • © 2000 Directed Electronics, Inc. Vista, CA 5 ■ A latched/reset with ignition output works similar to the latched output, but will also reset (output will stop) when the ignition is turned on and then off. ■ A 30 second timed output will send a signal for 30 seconds when channel three is pressed. This output can be shut off during the 30-second period by pressing Channel 3 again. ■ This

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 25 4. Press the transmitter button: While HOLDING the Valet ® /Program switch, press the button from the transmitter that you wish to assign to the selected channel. The unit will chirp indicating successful programming. It is not possible to teach a transmitter button to the system more than once. Channels #4-6: Channels 4 through 6 are used to assign the arm, disarm and panic functions to separate buttons on the remote control. Teaching a button to Channel 4 erases all information about that remote from memory. Any auxiliary functions that are d

  • Sidewinder 5000 ESP, 24 © 2000 Directed Electronics, Inc. Vista, CA transmitter/receiver learn routine ™ The system comes with two transmitters that have been taught to the receiver. The receiver can store up to four different transmitter codes in memory. Use the following learn routine to add transmitters to the system or to change button assignments if desired. When the learn routine has previously been programmed using an optional hand-held system programmer (p/n 998T) or PC Interface module, it may have been locked. Before proceeding with reprogramming the learn routine, it must be unlocked by using either p/n 998T or the PC Interface module - this cannot be done manual

  • 16 © 2000 Directed Electronics, Inc. Vista, CA on-board dual stage shock sensor There is a dual-stage shock sensor inside the control unit. Adjustments are made via the rotary control as indi- cated in the diagram. Since the shock sensor does not work well when mounted firmly to metal, we do not recommend screwing down the control module. The full trigger of the on-boa

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 23 2-4 PROGRESSIVE DOOR TRIGGER ON/OFF: The system responds to a door trigger input with a progressive response. When the door is opened with the system armed, the siren will chirp 10 times prior to the full trig- gered sequence. The door trigger is still treated as an instant trigger and closing the door quickly will not prevent a full triggered sequence from occurring. If the progressive door trigger is programmed off, the full siren output will occur the moment the door is opened. 2-5 VALET PULSE COU

  • 6 © 2000 Directed Electronics, Inc. Vista, CA H1/6 BLUE (-) INSTANT TRIGGER, ZONE 1 This input will respond to a negative input with an instant trigger. It is ideal for hood and trunk pins and will report on Zone 1. It can also be used with 506T Glass Breakage Sensor, as well as other DEI ® single stage sensors. The H1/6 BLUE instant trigger wire can be used to shunt sensors dur

  • 30 © 2000 Directed Electronics, Inc. Vista, CA nuisance prevention circuitry ™ NPC™ requires that you change the way you test the system as NPC™ will bypass an input zone for 60 minutes. If the system “sees” the same zone trigger three times AND the triggers are spaced less than an hour apart, the system will bypass that input zone for 60 minutes. If that

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 9 IMPORTANT! Remember that the functions of these wires are reversed between Type A and Type B! This system is common in many Toyota, Nissan, Honda, and Saturn models, as well as Fords with the keyless- entry system (some other Fords also use Type B). The switch will have three wires on it, and one wire will test ground all the time. One wire will pulse (-) when the switch locks the doors, and the other wire will pulse (-) when the switch unlocks the doors. This type of system

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 15 plug-in harnesses The super bright LED operates at 2V DC. Make sure the LED wires are not shorted to ground as the LED will be damaged. Multiple LED’s can be used, but they must be wired in series. The LED fits into a 9/32 inch mounting hole. Be sure to check for clearance prior to drilling the mounting hole. The Valet ® /Program switch should be accessible from the driver’s seat. It plugs into the blue port on the side of the unit. Since the system features Valet ® by using the remote transmitter, the swi

  • Sidewinder 5000 ESP, 18 © 2000 Directed Electronics, Inc. Vista, CA system features learn routine ™ The System Features Learn Routine ™ dictates how the unit operates. Due to the number of steps, they have been broken up into two menus. It is possible to access and change any of the feature settings using the Valet ® /Program switch. However, this process can be greatly simplified by using the optional DEI Bitwriter or Personal Computer Interface, P/N 996T. Any of the settings can be changed and then assigned to a particular transmitter, up to four, a feature called Owner Recognition. Each time that particular transmitt

  • Sidewinder 5000 ESP, © 2000 Directed Electronics, Inc. Vista, CA 7 H1/10 BROWN (+) SIREN OUTPUT Connect this to the red wire of the Revenger ® siren. Connect the black wire of the siren to (-) chassis ground, preferably at the same point you connect the control module’s black ground wire. H1/11 RED (+)12V CONSTANT POWER INPUT Before connecting this wire, remove the supplied fuse. Connect to the battery positive terminal or the constant 12V supply to the ignition switch. NOTE: Always use a fuse within 12 inches of the point you obtain (+)12V. Do not use the 15 fuse in the ha

  • Sidewinder 5000 ESP, 22 © 2000 Directed Electronics, Inc. Vista, CA 1-8 AUTOMATIC ENGINE DISABLE (AED) ON/OFF: AED is a full-time, passive starter disable that works independently of the security system. When turned on, the orange, ground-when-armed output (H1/1) will go active 30 seconds after the ignition is turned off. The LED will flash at half its normal rate when the ignition is turned off to indicate that AED is active and will interrupt the starter in 30 seconds. AED does not occur in Valet ® mode and can be bypassed using the emergency override procedure. The transmitter can be used to disarm AED; however, the system must be armed and then disarmed with the transmitter, in or

Related Products and Documents (Car Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Electro-Voice Cobreflex III Specifications electro-voice/cobreflex-iii-87H.pdf 06 Aug 2023 2 0.34 Mb
2 ACME BH03 Operation & user’s manual acme/bh03-AQ7.pdf 19 Mar 2023 36
3 REVELL Concerta C12 Brochure revell/concerta-c12-F81.pdf 29 Feb 2024 20 2.38 Mb
4 Saeco 741415808 Operation & user’s manual philips/741415808-W18.pdf 29 Mar 2024 54 1.61 Mb
5 Philips LFH0660/00 Specifications philips/lfh0660-00-6B2.pdf 23 Oct 2023 2 0.39 Mb
6 Whirlpool MH7135XE Use and care manual whirlpool/mh7135xe-553.pdf 22 May 2023 58 3.08 Mb

Similar Resources:

  • NAPCO

    2WAY-UNIVKF

    (24 pages)
    WI1024J 1/04 © NAPCO 2004 ® 2WAY-UNIVKF Bi-Directional LCD KeyFob Installation Instructions 2WAY-UNIVKF_WI1024J.19_I... page 1Wednesday, July 06, 2005 14:05 Compositewww.BevanSecurity.Com …
  • Bulldog Security

    3001

    (6 pages)
    System Features....................................... 1Technical Assistance .................................. 1Wiring Instructions ................................... 2Installation Instructions ............................. 3Operating Instructions .............................. 4-5CONTENTSTALKING ALARM • MODEL 3001INSTALLATION GUIDE•OWNER’S GUIDETech …
  • iDataLink

    Maestro RR

    (15 pages)
    NOTICE: Automotive Data Solutions Inc. (ADS) recommends having this installation performed by a certifi ed technician. Logos and trademarks used here in are the properties of their respective owners.WARNINGPressing the printer icon or “quick printing” this document will printall of the guides in this compilation.Open the Bookmarks menu and find your veh …
  • Webasto

    Thermo Top E

    (32 pages)
    WARNING!Hazard warning:Incorrect installation or repair of Webasto heating systems may cause a fire or result in the emission of carbon monoxide, which can be fatal. Serious or fatal injuries can be caused as a result.Specialist company training, technical documentation, specialized tools and equipment are required to install and repair Webasto heating and c …
  • Pyle

    PWD206

    (1 pages)
    PWD206 - TRANSPONDER IMMOBILISER OPERATING INSTRUCTIONS Overview The PWD206 is a safety device using the most advance technologies of transponder chip that allow a user to start his vehicle only after presenting a transponder tag to a hidden coil (loop antenna). The operation is fully automatic and performance is 100% friendly. Arming the System To ar …
  • Ampire

    KV-Vivaro-B

    (8 pages)
    ampireKV-VIVARO-BGerman Engineering. Out of the ordinary.BedienungsanleitungOwner´s ManualBitte lesen Sie die komplette Anleitung aufmerksam durch, bevor Sie mit der Installation beginnen.Before attempting to connect or operate this product, please read the instructions completely.Scannen für die aktuellsteBedienungsanleitung …

Comments, Questions and Opinions: