Manualios.com

Siemens E382 EH81E 061 01 03 02 Service Manual

Siemens E382 EH81E 061 01 03 02 Manual Online:

4.6, 1645 votes
Siemens E382 EH81E 061 01 03 02 User Manual
Siemens E382 EH81E 061 01 03 02 User Guide
Siemens E382 EH81E 061 01 03 02 Online Manual

Text of Siemens E382 EH81E 061 01 03 02 User Guide:

  • Siemens E382 EH81E 061 01 03 02, 22 Siemens-Elema AB E382 EH81E 061 01 03 02 Disassembling and assembling Compressor Compact Disassembling and assembling General • This chapter describes disassembling and assembling of some of the main parts of the Compressor Compact. The drawings in the Spare Parts List are also useful as a guide when disassembling and assembling the Compressor Compact. • To avoid the possible spillage of water, before disassembling the Compressor Compact run the unit until the solenoid valves in the dryer section operate to drain water into the drainage bottle. Then remove the drainage bottle, em

  • Siemens E382 EH81E 061 01 03 02, © Siemens-Elema AB, Electromedical Systems Division, 1993-1999. All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, or transmitted in any form or by any means, electronic, mechanical, photocopying, recording, or otherwise, without the prior permission of the copyright owner in writing. Subject to alterations without prior notice. Issued by Siemens-Elema AB, Electromedical Systems Division, SE-171 95 SOLNA, Sweden. Compressor Compact – Service Manual Order No.: 60 27 044 EH81E E382 EH81E 061 01 03 02 Printed in Sweden. TK 81 TU 0

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact Disassembling and assembling E382 EH81E 061 01 03 02 Siemens-Elema AB 29 Compressor To disassemble the compressor • Remove the compressor/motor unit as described in the section Compressor/motor unit. • Loosen the four screws (1) and lift off the fan shroud (2). • Disconnect the manifold pipe (3) and remove the rubber seals (4)*. • Disconnect the heat convector (5). • Using a 3/16" hexagonal wrench, remove the four cylinder head screws (6). • Remove the: – Cylinder

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact E382 EH81E 061 01 03 02 Siemens-Elema AB 9 Water separators 1 and 2 are automatically drained at regular intervals by the two filter/ solenoid valves. The water is collected in the drainage bottle. A low pressure switch is connected to the compressed air reservoir. This switch (sensor) detects the air pressure inside the compressed air reservoir and activates the pressure alarm if the air pressure in the reservoir drops. Compressors equipped with the standby function also include a standby solenoid valve and a standby pressure switch. Compressed air from the hospital central gas supply is connected to the compressed air reservoir (via the standby solenoid va

  • Compressor Compact E382 EH81E 061 01 03 02 Siemens-Elema AB 51 In this manual, the DIN IEC 757-standard is used when describing lead colours; BK = Black BN = Brown RD = Red OG = Orange YE = Yellow GN = Green BU = Blue VT = Violet GY = Grey WH = White PK = Pink GD = Gold SR = Silver TQ = Turquoise Circuit and connection diagrams 123455677 ++++ - - - - - ++++ - - - - - 12V

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact E382 EH81E 061 01 03 02 Siemens-Elema AB 47 Index A Air inlet silencer 6 Air inlet with filter 6 12 Air outlet section 10 19 B Belt pulleys 28 Buzzer 11 21 C Compressed air inlet 10 19 Compressed air outlet 10 19 Compressed air reservoir 10 19 37 Compressor 6 13 29 Compressor covers 23 Compressor section 6 12 Compressor/motor unit 26 Control section 11 20 38 Cooling air outlet 10 19 Cooling coil 7 14 Cooling section 7 14 D Drainage bottle 8 16 Drive belt 27 Drive unit 6 13 Dryer section 8 14 Dust filters 8 18 E Electric power supply 8 17 Electrical con

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact Disassembling and assembling E382 EH81E 061 01 03 02 Siemens-Elema AB 31 • There are guide holes in the cylinder head as well as in the gaskets and valve plates. These guide holes show how the various parts must be assembled: – The outlet valve (9) has a diagonal cavity and one guide hole. – The inlet valve (11) has two guide holes. • Tighten the cylinder head screws (6) to a torque of approx. 10.5 Nm ±0.5 Nm (95 lbf in ±5 lbf in). Retighten the screws to the above setting after the compressor has been in operation for about ten minutes. 11 9 6 COMP024X

  • Siemens E382 EH81E 061 01 03 02, 24 Siemens-Elema AB E382 EH81E 061 01 03 02 Disassembling and assembling Compressor Compact Transport safety locks To secure the compressor/motor unit and thereby prevent damage during transit of the Compressor Compact or when the Com- pressor Compact is turned upside down, the unit must be fixed to the base with two transport safety locks. When the transport safety locks are removed, the tension in the vibration dampers is released. To remove the transport safety locks • Open the front cover and remove the rear cover as d

  • Siemens E382 EH81E 061 01 03 02, 10 Siemens-Elema AB E382 EH81E 061 01 03 02 Compressor Compact Air outlet section The air outlet section contains the following main parts: • Compressed air reservoir • Pressure manometer • Moisture relief valve • Compressed air outlet • Compressed air inlet • Cooling air outlet. The dried air is supplied via water separator 1 in the dryer section to the compressed air reservoir. The compressed air is available at the compressed air outlet. The air pressure in the compressed air reservoir is displayed by the pressure manometer. If water, for som

  • Siemens E382 EH81E 061 01 03 02, 26 Siemens-Elema AB E382 EH81E 061 01 03 02 Disassembling and assembling Compressor Compact Compressor/motor unit To remove the compressor/motor unit • Open the front cover and remove the rear cover and the casing as described in the section Compressor covers. • Disconnect the two tubes (1) at the compressor inlets. • Disconnect the tube (2) at the cooling coil. • Disconnect the motor cables at the electrical interconnection block (4) in the dryer section (see Connection diagram). Loosen the cable sleeve (5) and withdraw the cable. Note – On older versions of the Compressor Compact, disconnect the ca

  • 42 Siemens-Elema AB E382 EH81E 061 01 03 02 Maintenance Compressor Compact Performing the 8000 hour overhaul 1. Replace inlet and outlet valves, cylinder and head gaskets, piston rings, piston seals and rider rings in the compressor. Also replace the rubber seals in the manifold pipe. See instructions in the chapter Disassembling and assembling, section Compressor. 2. Replace the d

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact E382 EH81E 061 01 03 02 Siemens-Elema AB 11 Control section The control section contains the following main parts: • On/off switch • Operating time meter • Electrical control functions • Test button • Indicator lamps • Buzzer. Mains power to the compressor is connected via and controlled by the on/off switch. The operating time meter indicates how many hours the compressor has been running. Electrical control functions are located on a PC board in the control section. This PC board also contai

  • Siemens E382 EH81E 061 01 03 02, 18 Siemens-Elema AB E382 EH81E 061 01 03 02 Description of functions Compressor Compact 3.12 Fuses The compressor is equipped with three FUSES: two mains power fuses (F1 and F2) and one fuse for the 12 V power supply (F3). The fuses are located in the 3.11 ELECTRI- CAL INTERCONNECTION block. Fuse No. Type No. Manufacturer Dimension 115 V versions Mains power fuses: F1/F2 MDA 10A 250V Bussman 6.3 x 32 12 V power fuse: F3 MDA 15A 250V Bussman 6.3 x 32 230 V versions Mains power fuses: F1/F2 T 6.3AL – 5 x 20 12 V power fuse: F3 T 10AL 250V Littelfuse 5 x 20 When replacing fuses in the Compressor Compact

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact Disassembling and assembling E382 EH81E 061 01 03 02 Siemens-Elema AB 37 Compressed air reservoir To remove the air reservoir • Refit the transport safety locks as described in section the Transport safety locks. • Turn the Compressor Compact upside down. Note – The compressor must not be turned upside down if the compressor casing is removed. • Remove the compressed air outlet nipple (1). • Compressors equipped with standby function: remove the compressed air inlet nipple (2). • Disconnect the moisture relief valve tube (3). • Remove the three clamps (4). • Lift off the complete

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact Description of functions E382 EH81E 061 01 03 02 Siemens-Elema AB 21 5.7 Standby lamp The yellow STANDBY LAMP will be on only when the compressor is in standby mode, i. e. when the 4.1 COMPRESSED AIR RESERVOIR is supplied with compressed air from the hospital central gas supply. The standby function can be described as follows: 1.With the compressor switched off, connect compressed medical grade air from the hospital central gas supply to the 4.5 COMPRESSED AIR INLET. The gas pressure must be above approx. 300 kPa (3.0 bar). Switch on the compres

  • 14 Siemens-Elema AB E382 EH81E 061 01 03 02 Description of functions Compressor Compact 2. Cooling section 2.1 Cooling coil A further preliminary cooling of the compressed air is provided by the COOLING COIL assembly, which is made of metal tubing. The compressed air to this cooling coil is supplied from the 1.7 HEAT CONVEC- TOR, and the output is connected to 3.1 WATER SEPARATOR 1.

  • Compressor Compact Adjustments E382 EH81E 061 01 03 02 Siemens-Elema AB 39 Adjustments Pressure regulator • Open the compressor’s front cover to make the pressure regulator accessible. • Connect the test nozzle to the compressed air outlet. • Start the compressor with the on/off switch. • At the pressure regulator, pull the control knob out until the snap lock on the knob is released an

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact Description of functions E382 EH81E 061 01 03 02 Siemens-Elema AB 15 A cooler temperature switch (thermostat) is connected to the Peltier element. The switch detects the temperature at the cool side of the element. To avoid formation of ice in the thermoelectric cooler, this switch will cut the power supply to the Peltier element if the temperature drops below approx. +2°C (+36°F). This thermostat is factory calibrated and must not be adjusted. The PC board RCD connected to the thermo- stat is a spark arrestor. This PC board RCD is includ

  • Compressor Compact Troubleshooting E382 EH81E 061 01 03 02 Siemens-Elema AB 43 One purpose of the Description of functions, the Circuit and connection diagrams, and the Block diagram in this Service Manual is to make it easier to trace faults. With mains power supply connected to the unit, there are energized electrical components as well as moving mechanical parts inside the equipment. All

  • Siemens E382 EH81E 061 01 03 02, 28 Siemens-Elema AB E382 EH81E 061 01 03 02 Disassembling and assembling Compressor Compact Belt pulleys To remove the belt pulleys • Remove the compressor/motor unit as described in the section Compressor/motor unit. • Remove the drive belt as described in the section Drive belt. • Remove the two screws (1). • Put one of the screws in the hole (2) and tighten it until the belt pulley loosens from the shaft. To refit the belt pulleys • Fit the belt pulley on the shaft and tighten the scre

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact E382 EH81E 061 01 03 02 Siemens-Elema AB 49 In this manual, the DIN IEC 757-standard is used when describing lead colours; BK = Black BN = Brown RD = Red OG = Orange YE = Yellow GN = Green BU = Blue VT = Violet GY = Grey WH = White PK = Pink GD = Gold SR = Silver TQ = Turquoise Circuit and connection diagrams 123556 +++ - - - +++ - - - 12V L1 N NNNNN L1 N N N N N F1 F2 F3 + - 10 11 12 13 14 8102 3 4 9 10 11 12 13 14 1 2 3 5 5 6 1 RD BK BK BK BK BK YERD YERD YEBK YEBK BNWH BK BU BN BN BU BK/2 BK/1 YE GY BN BU WH VT GY RD BNBK RD GNBK RDBK WHBK BK BNGN BK TIME METER FAN CAPACITOR FAN COMPRESSOR MOTOR TRANSFORMER COOLER TEMP. S

  • Siemens E382 EH81E 061 01 03 02, 44 Siemens-Elema AB E382 EH81E 061 01 03 02 Troubleshooting Compressor Compact Malfunction Action The compressor stops; the mains power lamp stays on: • The thermal switch inside the motor may have tripped. 115 V version: The thermal switch on the motor must be reset manually. 230 V version: The thermal switch will reset automatically and the motor will restart. Operating pressure (shown on the mano- meter) is correct during functional check but drops when a ventilator is connected: • Too high air consumption. The compressor cannot supply the equipment connected. • The dust filters or the air inlet filter are clogged. Clean or replace

  • Siemens E382 EH81E 061 01 03 02, Compressor Compact Disassembling and assembling E382 EH81E 061 01 03 02 Siemens-Elema AB 33 Water separator 2 To remove water separator 2 • Open the front cover and remove the rear cover and the casing as described in the section Compressor covers. • Disconnect the water tube (1) from the metal bowl. • Unscrew the metal bowl (2). • Remove the plastic shield (3) and the filter insert (4). Note – The filter insert (4) and the O-ring (5) must be replaced at the 8000 hour overhaul. • Disconnect the air tu

Related Products and Documents (Air Compressor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Lenkeng LKV8000 Operation & user’s manual lenkeng/lkv8000-F5Q.pdf 18 Aug 2022 6
2 Konica Minolta Magicolor Plus Software operation manual konica-minolta/magicolor-plus-JM8.pdf 03 Nov 2022 32
3 Extreme Networks E4G Series Installation manual extreme-networks/e4g-series-TGF.pdf 04 Mar 2023 128
4 Saito FA-30S(H) Instruction manual saito/fa-30sh-ER3.pdf 16 Feb 2024 24
5 Westinghouse VR3225 Operation & user’s manual westinghouse/vr3225-487.pdf 01 Nov 2023 30 2.6 Mb
6 Lenovo L2060 Manual  lenovo/l2060-XZI.pdf 05 Apr 2023 26

Similar Resources:

  • EWELLY

    EW-285L

    (2 pages)
    Version:285L.19.03.25Welcome to choose our instruments. This micro-computer temperature controller is specialized designed for refrigerator and freezer, easy-to-use, accurate control, and strong anti-interference. Our sensor is precisely made and sealed. It is moisture proof, therefore its performances are more stable and …
  • Danfoss

    MLZ Series

    (2 pages)
    InstructionsDanfoss scroll compressors MLZ© Danfoss | DCS (CC) | 2018.068510284P01C - FRCC.PI.048.A3.02 | 1A: Model numberB: Serial NumberC: Technical numberD: Internal protectionE: Manufacturing yearF: Supply voltage range G: Locked rotor current Maximum operating currentH: Lubricant type and nominal chargeI: Approved Refrigerant Cond. temp. (° …
  • Effectrode

    PC-2A

    (2 pages)
    Review of the PC-2A Photo-optical TubeCompressor by OvnilabsEffectrode PC-2A: This is anoptical comp pedal with a tube gainstage. It uses a 6021 militarysubminiature tube instead of theusual 12A*7 used by most similarpedals. This tube offers greaterresistance to vibration and impact,and a slightly different tone andfeel.The optical element has a fastattack, …
  • Shure

    FP51

    (8 pages)
    222 HARTREY AVENUE SHU- @EVANSTON, ILLINOIS 60202-3696 USA. (0 THE SOUND OF THE PROFESSIONALS' PROFESSIONAL PRODUCTS ..+ 63 3 0 0 rn I- ll v 2 D --I rn 0 0 0 = v rn m V) V) 0 P g 2 rn 3 II 0 I 2 - 0 D I 0 D 111 D ; GENERAL Listed by Underwriters Laboratories Inc.; listed by Cana- The FP51 is a compact, portable, high-quality gated memory dian Standar …
  • Craftsman

    921.166390

    (20 pages)
    Owner's ManualAIR COMPRESSOR7-gallon1 HPOil LubricatedModel No. 921.1CAUTION:Before using this product,read this manual and followall its Safety Rules andOperating Instructions.• Safety Instructions• Installation & Operation• Maintenance & Storage• Troubleshooting Guide• Parts List• EspaSol, p. 10Sears, Roebuck and Co., Hoffman Estat …
  • Sealey

    MAC2300

    (2 pages)
    INSTRUCTIONS FORAIR COMPRESSOR 12V HEAVY DUTYMODEL NO: MAC2300Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these instructions, and properly maintained, give you years of trouble free performance.IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, …

Comments, Questions and Opinions: