  • 33 Siemens Building Technologies Fire Safety & Security Products 10.2008 Screen Parameter Value Function VCR/DVR control output Communications Settings, Channel 3 VCR 2 Multiplexer Settings, Multiplexer 1 Timeout 5 VCR/DVR Settings, VCR/DVR 1 Timeout 5 VCR/DVR Settings, VCR/DVR 2 Timeout 5 Tab. 18 Example changes to default configuration for VCR/DVR and M

  • Siemens VIS3I-328, 17 Siemens Building Technologies Fire Safety & Security Products 10.2008 Name Description Type Conductor Number Conductor Function Serial Port 1 DCD 2 RX 3 TX 4 DTR 5 GND 6 DSR 7 RTS 8 CTS 9 RI PCCON Remote Control (RS-232, reconfigurable) 9-way D-Type Male Shield GND 2 (17) 1 NC 2 TX 3 RX 4 NC 5 GND 6 NC 7 NC 8 NC 9 NC Test/Config Test and Configuration Port (RS-232, reconfigurable) 9-way D-Type Female Shield GND 9 1 +12 V 2 +12 V 3 NC 4 TX- 5 RX-, DATA_485- 6 GND 7 GND 8 TX+ 9 RX+, DATA_485+

  • Siemens VIS3I-328, 8 Siemens Building Technologies Fire Safety & Security Products 10.2008 Single VIS3I-328 Expanded VIS3I-328 Pair Internal Option Cards V3-QUAD: quad card with independent BNC o/p 0 – 2 0 – 4 Power Input Voltage 110 – 230 V AC Frequency 50/60 Hz Power consumption 2 A 4 A Physical – Unit Height in rack units 3 U 6 U Extra height of mounting feet 7 mm 14 mm Extra width of rack mount brackets 50 mm Weight 8.8 kg 17.6 kg Physical – Package Dimensions (W × H × D) 560 × 275 × 550 mm – Total weight 12.7 kg – Storage Conditions Temper

  • Siemens VIS3I-328, 12 Siemens Building Technologies Fire Safety & Security Products 10.2008 6.2 Printed circuit boards (PCBs) The VIS3I-328 contains four printed circuit boards (PCBs) to provide control, configuration, access to the input/output connectors and interfacing to the two option cards. The PCBs are: 1 Control PCB 2 BNC Connector PCB 3 D Connector PCB 4 Slot Expansion PCB The PCBs are fixed within the unit enclosure and are therefore not considered to be user serviceable parts. Fig. 3 shows the location of the PCBs within the unit. 1 3 42 Fig. 3 Printed circuit boards

  • 15 Siemens Building Technologies Fire Safety & Security Products 10.2008 6.5 Front panel indicators The VIS3I-328 unit has 40 single colour LED indicators on the front panel. The LEDs are located in 4 distinct groups: Indicator Group Number of LED Mode 3 Network 1 Relays 4 Video Loss 32 Fig. 6 Front panel indicators Indicator Group Name

  • Siemens VIS3I-328, 34 Siemens Building Technologies Fire Safety & Security Products 10.2008 A VCR/DVR RECORD INPUT B VCR/DVR PLAY OUTPUT C VCR/DVR #1 D RS232C PORT E VIDEO INPUTS 1-16 F MPX #1 G CAMERA LOOPTHROUGH OUTPUTS 1-16 H VIS3I-328 I SERIAL CHANNEL 1 J SERIAL CHANNEL 2 K SERIAL CHANNEL 3 L CAMERA LOOPTHROUGH OUTPUTS 17-32 M VCR/DVR #2 1 MULTISCREEN OUT 2 MON A OUTPUT NOTE DVRs generally do not require multiplexers as VCRs do, so you can connect them directly to the VIS3I-328 loop through outputs, as shown. You can also connect multiplexer or DVR monitor outputs back

  • Siemens VIS3I-328, 52 Siemens Building Technologies Fire Safety & Security Products 10.2008 Unit Connector Name Interface Loopback type for first test Loopback type for second test Serial Port 1 RS-232/422 RS-232 Male RS-422 PCCON Port 2 RS-232 RS-232 Female Serial Port 3 RS-232/422 RS-232 Male RS-422 Serial Port 4 RS-232/422 RS-232 Male RS-422 Test/Config Port 9 RS-232 (None – connected to VisiPC) Keyboard Port 10 RS-422/485 RS-422 Master or standalone Option card ports 12 & 13 RS-23

  • 38 Siemens Building Technologies Fire Safety & Security Products 10.2008 Screen Parameter Value Nodes 3 Global System Settings Node Trunks 2 Function Network control input Communication Settings, Channel 1 Protocol VisiWire Function Network control input Communication Settings, Channel 3 Protocol VisiWire Name N1 Node Settings Remote Prefix 1 2 Neighbour Node End

  • Siemens VIS3I-328, 11 Siemens Building Technologies Fire Safety & Security Products 10.2008 6.1 Enclosure Fig. 2 VIS3I-328 enclosure The VIS3I-328 enclosure comprises four main parts: z Base assembly z Cover z Front panel z Rack mount brackets (optional) The base assembly is fabricated from 1.2 mm zintec sheet with a natural finish. It provides fasteners for mounting the cooling fan and the control card. Cut-outs are provided on the rear panel for the mounting the input/output connectors (see chapter 6.6 Rear panel connections and controls). Details of the connectors are screen pri

  • Siemens VIS3I-328, 7 Siemens Building Technologies Fire Safety & Security Products 10.2008 3 Technical data 3.1 Specifications Single VIS3I-328 Expanded VIS3I-328 Pair Video Connections Input connectors 32 BNC 64 BNC Input level 0.7 – 1.5 Vpp Input impedance 75 Ohm Loop-through connectors 32 BNC 64 BNC Output connectors 8 BNC 16 BNC Output impedance 75 Ohm Video Performance (nominal) Frequency response (-3 dB point) > 5 MHz Chrominance delay < 15 nsec < 18 nsec Chrominance gain > 97 % > 91 % K-rating (2T pul

  • Siemens VIS3I-328, 39 Siemens Building Technologies Fire Safety & Security Products 10.2008 Screen Parameter Value Function Network control input Communication Settings, Channel 1 Protocol VisiWire Name N3 Node Settings Remote Prefix 2 Neighbour Node End, Node 1 Neighbour Node End, Trunk 2 Local Node End, Direction Output Node Trunk Settings, Node trunk 1 Local Node End, Monitor 8 Tab. 24 Example changes to default configuration for Remote Node 2 (5) unit 9.6.4 Configuring network alarms The steps required to configure a remote node to broadcast its alarms over

  • Siemens VIS3I-328, Issued by Siemens Building Technologies Fire & Security Products GmbH & Co. oHG D-76181 Karlsruhe www.buildingtechnologies.siemens.com © 2008 Copyright by Siemens Building Technologies Data and design subject to change without notice. Supply subject to availability. Printed in the Federal Republic of Germany on environment-friendly chlorine-free paper. Document no. A6V10086958 Edition 29.10.2008

  • Siemens VIS3I-328, 25 Siemens Building Technologies Fire Safety & Security Products 10.2008 8.5 Confirm software versions 1. Run the VisiPC software. 2. If VisiPC starts as the Visilynx 3 Tester and Simulator, select the Visilynx3 Configurator sub-program at the Switch drop-down menu, as detailed in the VisiPC Software User Manual. 3. On the menu bar, select Transfer and then the Versions… option. This brings up the Software Version pop-up box. 4. Select each software Version Type, in turn,

  • Siemens VIS3I-328, 4 Siemens Building Technologies Fire Safety & Security Products 10.2008 9.6.7 Controlling 64 cameras x 64 monitors (full cross point)..........................44 9.7 Controlling via the Video Management Software IVM ............................45 9.8 Clock Synchronisation.............................................................................45 10 Maintenance and service......................................................................46 10.1 Routine maintenance ........................................................................

  • Siemens VIS3I-328, 22 Siemens Building Technologies Fire Safety & Security Products 10.2008 You can install two quad cards (VIS3-QUAD) as follows: 1. The quad card in the slot furthest from the power supply is connected to quad output A on the rear panel, and is controlled as monitor outputs 9–12. Note that on a single unexpanded unit, these are extra to the eight monitor outputs available on the rear panel. 2. The quad card in the slot nearest the power supply is connected to quad output B on the rear panel, and is controlled as monitor outputs 13–16. Note that on a single unexpanded unit, these are extra to th

  • 53 Siemens Building Technologies Fire Safety & Security Products 10.2008 NOTE If no route failures are detected, the self-test log shows the total routes tested. If failures are detected, only the failures are shown. Self-test results A full list of all the possible self-test results is shown in Tab. 41. The actual test records provided depend on

  • Siemens VIS3I-328, 6 Siemens Building Technologies Fire Safety & Security Products 10.2008 1.3 Meaning of the signal words The severity of a hazard is indicated by the following written warning notices. Signal word Type of hazard CAUTION There is a risk of minor to medium injuries or damage to property IMPORTANT Malfunctioning may result 1.4 Meaning of the hazard symbols The nature of the hazard is indicated by icons. Warning of a hazard 2 Standards and guidelines The product meets the requirements of the following EU Directives. The EU decl

  • Siemens VIS3I-328, 13 Siemens Building Technologies Fire Safety & Security Products 10.2008 6.3 Power supply module VIS3I-PSU Fig. 4 Power supply module (VIS3I-PSU) Purpose A proprietary universal AC mains input, bipolar DC output switch mode power supply fixed on a mounting tray (shown above) for ease of replacement (see chapter 4 Details for ordering). NOTE For information on the replacement and the specifications of the power supply module please refer to the installation instruction for VIS3I-PSU.

  • Siemens VIS3I-328, 10 Siemens Building Technologies Fire Safety & Security Products 10.2008 6 Description of equipment The Visilynx 3i (VIS3I-328) is a 32 loop-through input by 8-output full cross-point video matrix node contained in a 19” wide by 3U high enclosure. You can connect two identical units together using an expansion cable to double the size of the video matrix to 64 loop-through input by 16-output full cross-point switcher. In this configuration, you set one of the two units to be the Master and this

  • Siemens VIS3I-328, 3 Siemens Building Technologies Fire Safety & Security Products 10.2008 Contents 1 Safety .......................................................................................................5 1.1 Target group..............................................................................................5 1.2 General safety precautions .......................................................................5 1.3 Meaning of the signal words .....................................................................6 1.4 Meaning of the hazard symbols ...........

Related Products and Documents (Matrix Switcher):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Fisher-Price G5779 Operation & user’s manual fisher-price/g5779-885.pdf 01 Mar 2023 4 0.36 Mb
2 EVGA GeForce 9800 GT HDMI Product specifications evga/geforce-9800-gt-hdmi-A7E.pdf 19 Oct 2023 1 1.08 Mb
3 Aroma ARC-727-1NG Instruction manual aroma/arc-727-1ng-E6H.pdf 17 Dec 2022 12 1.01 Mb
4 Zhejiang NVR300 Series Manual  zhejiang/nvr300-series-VLD.pdf 01 Feb 2024 57
5 Summit FCL-44 Instruction manual summit/fcl-44-4Q9.pdf 16 Apr 2024 4
6 Fujitsu Lifebook TH700 Getting started fujitsu/lifebook-th700-CNG.pdf 30 Jul 2022 12 2.54 Mb

Similar Resources:

  • Sony

    PVS-R102

    (14 pages)
    PVS-R102Matrix Switcher2-347-513-22 (1)Operating InstructionsBefore operating the unit, please read this manualthoroughly and retain if for future reference. 2002 Sony Corporation …
  • Shinybow USA

    SB-5688CT-A

    (28 pages)
    In st ru ction ManualPart No.: ENCL005688CTAA0Thank you for purchasing the SB-5688CT-A HDMI-HDBaseT Matrix Switcher. You will find this unit easy to install and highly reliable but it is essential that you read this manual throughly before attempting to use 8x8 HDMI-HDBaseT Matrix switcher.HDMI-HDBaseT MATRIX SWITCHER SERIES8x8 HDMI-HDBaseT MATRIX SWITCHERM …
  • Kramer

    1608V3S

    (2 pages)
    © www.kramerelectronics.com 2008 1608V3S 16x8 SIERRA PRO™ 16 SERIES ROUTING SWITCHERS SIERRA PRO 1608 SERIES SERIES 16X8 YUV MATRIX SWITCHER WITH BALANCED STEREO AUDIO DESCRIPTION The Sierra PRO 16 series are high bandwidth routing switchers for RGBHV, RGBS, RGB and s-Video (Y/C) signals. These units come in a compact 3U (5.25”) frame and can rou …
  • Accell

    UltraAV

    (2 pages)
    UltraAV® HDMI 1x2 Audio/Video Splitter READ ME FIRST – SETUP INSTRUCTIONS Congratulations on your purchase of the UltraAV HDMI 1-2 Audio/Video Splitter. This HDMI splitter is designed to provide exceptional performance and value. It allows access to 2 HDMI display devices from a single HDMI video source. For a DVI device, use an optional HDMI …
  • Kramer

    XL 1208V4S

    (2 pages)
    © www.kramerelectronics.com 2008 Sierra Pro XL 1208V4S 12x8 SIERRA PRO™ XL 12 SERIES ROUTING SWITCHERS SIERRA PRO XL 1208 SERIES SERIES 4-CHANNEL (3 VIDEO AND 1 SYNC CHANNELS) WITH STEREO AUDIO. DESCRIPTION The Sierra Pro XL 12 series are high bandwidth routing switchers for RGBHV, RGBS, RGB and s-Video (Y/C) signals. These units come in a compact 3U …
  • Kramer

    1616V3S

    (2 pages)
    © www.kramerelectronics.com 2008 1616V3S 16x16 SIERRA PRO™ 16 SERIES ROUTING SWITCHERS SIERRA PRO 1616 SERIES SERIES 16X16 YUV MATRIX SWITCHER WITH BALANCED STEREO AUDIO DESCRIPTION The Sierra PRO 16 series are high bandwidth routing switchers for RGBHV, RGBS, RGB and s-Video (Y/C) signals. These units come in a compact 3U (5.25”) frame and can r …

Comments, Questions and Opinions: