SurgeX SU-1500-DC Operation & User’s Manual

SurgeX SU-1500-DC Manual Online:

3.05, 1595 votes
SurgeX SU-1500-DC User Manual
SurgeX SU-1500-DC User Guide
SurgeX SU-1500-DC Online Manual

Text of SurgeX SU-1500-DC User Guide:

  • SurgeX SU-1500-DC, 1noitcudortnI.1 2. Controls and Indicators 5 8noitallatsnI.3 11noitarepO.4 41gnitoohselbuorT.5 51yrettaB eht gnicalpeR.6 81ecivreS gniniatbO.7 91snoitacificepS.8 9. Configurable Parameters & Settings 21 10. Limited Product Warranty 22 © 2011 SurgeX TABLE OF CONTENTS

  • IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS ! Thank you for purchasing this power protection product. It has been designed and manufactured to provide many years of trouble free service. This symbol indicates "ATTENTION" This symbol indicates "Risk of Electrical Shock" This symbol indicates "Alternating Current Supply" This symbol indicate

  • SurgeX SU-1500-DC, WARNING: Risk of Electrical Shock. Hazardous live parts inside these power supplies are energized from the battery even when the AC input is disconnected. CAUTION! To de-energize the outputs of the UPS: 1. If the UPS is on press and release the Off button. 2. Disconnect the UPS from the AC wall outlet. 3. To de-energize the UPS completely, disconnect the battery. CAUTION! To reduce the risk of electrical shock in conditions where the load equipment grounding cannot be verified, disconnect the UPS from the AC wall outlet before installing a computer interface cable. Reconnect the power cord only after all signaling c

  • SurgeX SU-1500-DC, After removing your UPS from its carton, it should be inspected for damage that may have occurred in shipping. Immediately notify the carrier and place of purchase if any damage is found. Warranty claims for damage caused by the carrier will not be honored. The packing materials that your UPS was shipped in are carefully designed to minimize any shipping damage. In the unlikely case that the UPS needs to be returned to the manufacturer, please use the original packing material. Since the manufacturer is not responsible for ship- ping damage incurred when the system is returned, the original packing mate- rial is inexpensive insurance. PLEASE SAVE THE PACKING MATERIALS! Receiving In

  • SurgeX SU-1500-DC, Life Support Policy As a general policy, we do not recommend the use of any of our products in life support applications where failure or malfunction of the product can be reason- ably expected to cause failure of the life support device or to significantly affect its safety or effectiveness. We do not recommend the use of any of our prod- ucts in direct patient care. We will not knowingly sell our products for use in such applications unless it receives in writing assurances satisfactory to us that (a) the risks of injury or damage have been minimized, (b) the customer assumes all such risks, and (c) our liabil

  • SurgeX SU-1500-DC, The ONLINE (green) LED illuminates in a steady state when the UPS is on and the inverter is providing the output power. The ONLINE LED will extinguish when oper- ating in the Battery mode. The LINE (green) LED illuminates in a steady state when the UPS is connected to Utility Power and there is an acceptable AC voltage present. The LINE LED will extinguish when operating in the Battery mode and if the Utility voltage is not present. The LINE LED will flash when the Utility voltage or frequency is out of the Bypass mode range. The BYPASS (yellow) LED will be flashing when the UPS is oper

  • The ON BATT (green) LED illuminates in a steady state when the UPS is oper- ating in the Battery mode. The ON BATT LED will extinguish when operating in the On-Line and the Bypass modes. The BATT LOW (yellow) LED illuminates in a steady state when the UPS reaches a low battery condition. The BATT LOW LED is extinguished when the UPS is in the On-Line mode and when t

  • REAR PANEL Output Power Receptacles Input Power Plug (All power cords are 10ft) NEMA 5-15P 6-NEMA 5-15R 1. The input power cord (120V models). 2. The input circuit breaker will trip in the event the load exceeds the UPS’s power rating. 3. The option slot is for option cards. 4. The Battery Backup output power receptacles. The output receptacles are electrically wir-

  • SurgeX SU-1500-DC, INSTALLATION PLACEMENT This UPS series is intended to be install in a temperature controlled environ- ment that is free of conductive contaminants. Select a location which will provide good air circulation for the UPS at all times. Avoid locations near heat- ing devices, water or excessive humidity, or where the UPS is exposed to direct sunlight. Route power cords so they cannot be walked on or damaged. Operating Temperature (Maximum): 0 to 40 degrees C (+32 to +104 degrees F) Operating Elevation: 0 to 3,000m (0 to +10,000 ft) Operating and Storage Relative Humidity: 95%, non-condensing St

  • SurgeX SU-1500-DC, RACKMOUNT CONFIGURATION The UPS comes with mounting brackets for the standard 19" (46.5cm) rack. The mounting brackets to fit a 23" (59.2cm) standard rack are also available. The screws for mounting the UPS to the rack are not included (screw size varies with rack size). 1. Locate the mounting bracket screw holes on the side panels of the UPS, at the front of the UPS. NOTE: The mounting brackets can also be mounted in the middle of the UPS. 2. Align the mounting bracket with the mounting bracket screw holes. 3. Attach the mounting bracket with the retaining screws. 4. Mount the UPS into the rack and secure with the

  • SurgeX SU-1500-DC, CHARGING THE BATTERY COMMUNICATIONS PORT CONNECTION (OPTIONAL) The Power Monitoring Software and interface cables can be used with the UPS. Use only the interface cables that come with these UPSs. Connect the inter- face cable (Serial or USB) to the appropriate communications port on the rear panel of the UPS. Connect the other end of the cable to the device that will be monitoring/controlling the UPS. NOTE: Connecting to the Communications Port is optional. The UPS works properly without this connection. CONNECTING THE UPS TO AN AC SOURCE Plug the UPS into a two pole, three wire, grounded receptacle only. Do not use extension cords, adapter plugs, or surge strips. N

  • SurgeX SU-1500-DC, SYSTEM OVERVIEW This On-Line UPS protects computers, servers, internetworking, and telecom- munications equipment from blackouts, brownouts, overvoltages, and surges. This On-Line UPS converts the input AC to DC and then back to a True Sine Wave AC output. The True Sine Wave output is regulated within 2% of the nominal output voltage. The Power Factor Correction (PFC) circuitry corrects the input power factor to within 97% of unity and blocks the load generated harmonic distortion from getting back on the input AC line. This On-Line UPS provides a continuous true sine wave output with zero t

  • SurgeX SU-1500-DC, SELF TEST The self test feature is useful to verify the correct operation of the UPS and the condition of the batteries. With the UPS in the AC normal mode, press the ON/ Test/Alarm Silencer Button for 1-beep (2-seconds) to perform a battery test. The UPS will perform a ten-second self test. During the self test, the UPS will switch to battery power and the ON BATT LED will illuminate and the audible alarm will sound. If the UPS fails a self test, one of the LEDs will remain illuminated indicating the type of problem. LOAD SHEDDING FUNCTION The output rec

  • SurgeX SU-1500-DC, ALARMS ON-BATTERY When the UPS is operating on the batteries, the ON BATT LED will illuminate and the audible alarm will sound once every ten-seconds. The alarm will stop once the UPS returns to the AC normal mode. LOW BATTERY WARNING When the batteries reach the pre-determined level the BATT LOW LED will illuminate and the audible alarm will sound two beeps every five-seconds. This condition will continue until AC returns or the UPS shuts down from battery exhaustion. UPS FAULT When the UPS detects a hardware fault, the FAULT LED will illuminate and the UPS will sound a constant alarm. The fault condition, in some instances, may be r

  • SurgeX SU-1500-DC, h Possible Cause Symptom What To Do Press and release the On/Off/ Test button to start UPS On/Off/Test button not pushed UPS will not turn on Reset circuit breaker by pressing the plunger back in. If the AC circuit breaker trips after UPS starts up, reduce the load on the UPS UPS operates in battery mode only, even though there is normal AC present Input AC circuit breaker is tripped UPS has detected an inter- nal fault Call for service Fault LED is illumi- nated The On-Line LED is illuminated, but there is no output Disconnect the computer cable from the UPS and press the On button. If UPS works normally,

  • SurgeX SU-1500-DC, REPLACING THE BATTERY WARNING! This Uninterruptible Power Supply contains potentially hazardous voltages. Do not attempt to disassemble the UPS beyond the battery replacement procedure. This UPS contains no user serviceable parts. Repairs and Battery replacement must be performed by QUALIFIED SERVICE PERSONNEL ONLY. Do not open or mutilate batteries. Released electrolyte is harmful to the skin and eyes and may be toxic. CAUTION: (QUALIFIED SERVICE PERSONNEL ONLY) CAUTION: Do not dispose of batteries in a fire. The batteries may explod

  • SurgeX SU-1500-DC, BATTERY REPLACEMENT PROCEDURE PLEASE READ THE CAUTIONS AND WARNINGS BEFORE ATTEMPTING TO REPLACE THE BATTERIES Hot-swappable batteries mean that the batteries can be replaced without powering down the whole UPS system. NOTE: If there is a power interruption while replacing the hot-swappable batte- ries, with the UPS on, the load will not be backed up. To hot-swap the batteries start with step number 6. 1. Turn off the equipment that is plugged into the output receptacles of the UPS. 2. Press the OFF button to turn the UPS off. 3. Unplug the UPS's AC power cord from the AC wall outle

  • 8. Remove the two retaining screws for the battery retaining bracket. (FIG. 3) 9. Remove the battery retaining bracket. (FIG. 3) 10. Disconnect the Battery connectors (red and black). (FIG. 4) 11. Grasp the battery pull tab and gently pull the battery module out of the UPS and set on the floor. (FIG. 4) NOTE: Use Caution, the battery module is heavy. 12. Disconnect the battery pos

  • SurgeX SU-1500-DC, IF THE UPS REQUIRES SERVICE 1. Use the TROUBLESHOOTING section to eliminate obvious causes. 2. Verify there are no circuit breakers tripped. A tripped circuit breaker is the most common problem. 3. Call your dealer for assistance. If you cannot reach your dealer, or if they cannot resolve the problem call or fax the Technical Support department at A. Your name and address. B. Where and when the unit was purchased. C. All of the model information about your UPS. D. Any information on the failure, including LEDs that may be illuminated. E. A description of the protected equipment, inc

  • SurgeX SU-1500-DC, Default: 120VAC, User selectable: 110VAC 1500VA/1200W Protection Waveform Type Over-Current, Short-Circuit Protected and Latching Shutdown True Sine Wave Frequency 50/60Hz, +/-0.1Hz (unless synchronized to utility) Nominal Voltage Maximum Power Capacity 0 ms >87% (Full Load) Resettable Circuit Breaker 50 or 60 Hz, +/-6Hz, autosensing 0 - 150VAC 90 - 138VAC 120VAC: 117.6 - 122.4VAC Transfer Time Efficiency (Line Mode) Input Protection Frequency Limits Voltage Range Acceptable Input voltage SYSTEM SPECIFICATIONS Voltage Range T

  • SurgeX SU-1500-DC, BATTERY SYSTEM Typical Recharge Time Typical Battery Life Battery: Quantity/Rating 3-5 years, depending on discharge cycles and ambient temp 4-12V7.2Ah 8-hours from total discharge Battery Type Sealed, Non-Spillable, Maintenance Free, Value Regulated Lead Acid System Voltage 48VDC Runtime: Full Load (minutes) Runtime: Half Load (minutes) 13 4 SURGE PROTECTION AND FILTERING Audible Noise at 1 m (3 ft.) 10/100 Base-T surge protec- tion let-through (as a percent- age of an applied +/-6 kV 1.2/ 50 us, 500 a 8/20 uS test) Telephone line surge protec- tion let-through (as a percent- age of an applied +/-6 kV 1.2/ 50 us, 500a 8

  • SurgeX SU-1500-DC, (These items may require optional software or hardware) Function Factory Default Description User Choices Set inverter output voltage Shut- down Type Set audible alarm state Enable/ Disable auto restart Battery life in days Battery install date UPS ID Endeavor Series Date of manufacture 1826 Enabled Enabled Entire UPS 120VAC Up to 64 charac- ters to define the UPS Date of battery replacement - month/day/year XX/XX/XXXX Up to 5 characters Enable or Disable Enabled, at low battery, disabled Entire UPS or UPS output 110, 115, 120VAC At first battery replacement, reset to reflect actual number of days experience in your environment or leave factory default

  • SurgeX SU-1500-DC, For a period of 11 years from the date of your purchase of any SurgeX product, SurgeX warrants the product against defects in materials used by SurgeX or workmanship performed by SurgeX (a "Covered Product"). SurgeX's obligations with respect to a Covered Product are to provide, at no charge, all labor and parts (either new or rebuilt, as determined in SurgeX's sole discretion) necessary for the repair of the Covered Product. If SurgeX, in its sole discretion, determines that a Covered Product is not repairable, SurgeX will replace the Covered Product with a pro

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 iCanTek iCanView 240 Operation & user’s manual icantek/icanview-240-598.pdf 23 Oct 2022 70
2 Silvercrest OM1008 User manual and service information silvercrest/om1008-95R.pdf 23 Oct 2022 76
3 CORRECT CRAFT G21 Owner's manual correct-craft/g21-7G8.pdf 24 Jul 2023 302
4 Belson C23-I-8M Use and care book belson/c23-i-8m-KB1.pdf 26 Mar 2023 2 0.38 Mb
5 Toshiba TLP-S40 Specifications toshiba/tlp-s40-Z4M.pdf 11 Apr 2023 2 0.07 Mb
6 Frigidaire FGQBB30DS0 Operating instructions manual frigidaire/fgqbb30ds0-499.pdf 06 Oct 2022 6 0.71 Mb

Similar Resources:

  • Powervar

    ACDEF700-11

    (63 pages)
    A01-00040 Rev. E POWERVAR Sinergy III Rackmount / Tower User Instruction Manual Sinergy III 120 Volt UPS · ACDEF700-11 700 VA UPS · ACDEF1000-11 1000 VA UPS · E024-12 External Battery Cabinet · ACDEF1500-11 1500 VA UPS · E036-12 External Battery Cabinet …
  • rocpower

    PRESTIGE 1

    (32 pages)
    power your future℠ PRESTIGEHighFrequencyOn‐LineUPSUserManual1,000VA2,000VA3,000VA …
  • Belkin

    F6H375.550USBT

    (2 pages)
    Protect your equipment and data during power failuresThe Home Office Series Battery Backup from Belkin gives you peace of mind during virtually all types of power disturbances. Designed to protect your computers, data, and other electrical equipment,these Battery Backups feature six surge-protected outlets thatdeliver grounded AC power to your computer. Four …
  • INFOSEC

    Z4 B-box 500 VA

    (64 pages)
    500 / 700 /1000 VA User guide____________________________________ 2Notice d’utilisation _____________________________ 9Gebruiksaanwijzing ___________________________ 16Bedienungsanleitung __________________________ 24Guía de usuario ______________________________ 32Manual do Utilizador __________________________ 40Εγχειρ …
  • Belkin

    400va

    (5 pages)
    Active Battery Back Up User ManualP75312mewww.belkin.com12INTRODUCTIONThis UPS is specially aimed for use with multi function Personal Computers. It is designed to be light weight and compact to fit perfectly into a working environment with limited space. The ‘Active’ UPS is equipped with boost and buck AVR to stabilise the input voltage range. It also …
  • Tripp Lite

    AG-04F5 Series

    (12 pages)
    1UPS SystemsModels:OMNIVSX850A, OMNIVSX1000A, OMNIVSX1500A (Series Numbers: AG-04F5, AG-04F1, AG-04F2)Owner’s Manual1111 W. 35th Street, Chicago, IL 60609 USA • tripplite.com/supportCopyright © 2020 Tripp Lite. All rights reserved. …

Comments, Questions and Opinions: