Text of PowerWalker VFI 1000RT User Guide:

  • PowerWalker VFI 1000RT, 34 Model 1000 1000S 1500 1500S 2000 2000S 3000 3000S UPS Case Net weight (kg) 16.2 8.4 19.7 9.3 19.7 9.3 28.6 13.2 Dimension (mm) (W x H x D) 438X86.5x436 438X86.5x608 EBM Case Dimension (mm) (W x H x D) Net weight (kg) 22.2 27.5 40.5 Type 36V 48V 72V Dane fizyczne

  • PowerWalker VFI 1000RT, 10 EN ★ Use No. 12 AWG (for 3KS input wire), 90°C copper wire and 4.4 lb-in Torque force when connecting to terminal block. ★ Use No. 10AWG (for all models battery wire), 90°C copper wire and Anderson PP45 connectors for user’s external battery cabinet. 1.3 Maintenance, servicing and faults ★ The UPS operates with hazardous voltages. Repairs may be carried out only by qualified maintenance personnel. ★ Caution - risk of electric shock. Even after the unit is disconnected from the mains power supply (building wiring socke

  • PowerWalker VFI 1000RT, 20 EN (2) UPS Output Connection The output of the UPS is IEC socket-types. Simply plug the load power cord to the output sockets to complete connection. Use one cord for every 5A load. Model No. Output Socket (pcs) 1K(S)/1.5K(S)/ 2K(S) 8 * IEC320 C13 3K(S) 8 * IEC320 C13 + 1 * C19 The wiring configuration is shown as the following procedure: a) Remove the small cover of the terminal block b) Use 2.5mm 2 wires for wiring configuration c) Upon completion of the wiring configuration, plea

  • PowerWalker VFI 1000RT, 13 EN 1.3.5 Testing New Batteries For a battery test, please check:  The batteries must be fully charged.  The UPS must be in Normal mode with no active alarms.  Don’t take on/off the load. To test batteries: 1. Connect the UPS to utility power for at least 48 hours to charge the batteries. 2. Press and hold the “I” button 1 second to start the battery test on line mode or HE mode. The status display string shows “TEST” 1.3.6 Recycling the Used Battery: To recycle properly the used battery, please do not discard the UPS, battery pack and batteries into the t

  • PowerWalker VFI 1000RT, 14 EN 1.6 Standards * Safety IEC/EN 62040-1-1 * EMI Conducted Emission..........................:IEC/EN 62040-2 Category C1 Radiated Emission.............................:IEC/EN 62040-2 Category C1 Harmonic Current...............................:IEC/EN 61000-3-2 Voltage Fluctuation and Flicker..........:IEC/EN 61000-3-3 *EMS ESD...................................................:IEC/EN 61000-4-2 Level 3 RS.....................................................:IEC/EN 61000-4-3 Level 3

  • PowerWalker VFI 1000RT, 19 EN 5. Connection and Operation 5.1 Inspection Inspect the packaging carton and its contents for damage. Please inform the transport agency immediately should you find signs of damage. Please keep the packaging in a safe place for future use. Note: Please ensure that the incoming feeder is isolated and secured to prevent it from being switched back on again. 5.2 Connection (1) UPS Input Connection If the UPS is connected via the power cord, please use a proper socket with protection against electric current, the use

  • PowerWalker VFI 1000RT, 31 EN Battery low Battery voltage is low When audible alarm sounding every second, battery is almost empty. Charge fail The charge is broken Notify dealer. Inverter temperature high Inside temperature of the UPS is too high Check the ventilation of the UPS, check the ambient temperature. Ambient temperature high The ambient temperature is too high Check the environment ventilation. Battery open Battery pack is not connected correctly Check the battery bank is connected to the UPS. Check the battery breaker is turn on. Battery fault Battery may need to be repla

  • PowerWalker VFI 1000RT, 17 EN 4. Panel Description The Display Panel Switch Function ON-Button Turn on UPS system: By pressing the ON-Button “I” the UPS system is turned on. Deactivate acoustic alarm: By pressing this Button an acoustic alarm can be deactivated in the battery mode. By short touch this Button all acoustic alarms can be deactivated in all mode. Do the battery test: By pressing this Button the UPS can do the battery test in the Line mode or ECO mode or Converter mod

  • PowerWalker VFI 1000RT, 37 EN The following figures show schematic of the dry out/in contacts. Dry out contact schematic Dry in contact schematic The following table shows the options for the dry out/in contacts Dry out signal Description Summary Alarm Activated when any warning happens On Battery Activated when the UPS operates on battery Battery Low Activated with the “bLOW” alarm UPS ok Activated when the UPS has no alarms and no fault. On Bypass Activated when the UPS has bypass output. Dry in signal Descripti

  • PowerWalker VFI 1000RT, 8 EN Connecting multiple EBMs in Tower form 1. Connect Earth line between UPS and the first EBM, and then connect Earth Line between the first EBM and the second EBM. 2. Take off the front panel, and connect the battery terminal (A) from UPS to EBM terminal (B) shown as below. And then connect the battery terminal (D) from the first EBM to the battery terminal (E) from the second EBM. Users need to remove the small gate(C) on side of the front panel to allow the outlet wire of the EBM to pass through the gate and then reassemble front panel. Connecting the Multiple EBMs in rack form 1. Connect Earth line between UPS and

  • PowerWalker VFI 1000RT, 22 EN change within 30 seconds; in resting mode, UPS will detect the change within 3 minutes; (2) Manual test Test the function of the UPS system by pressing the On-Switch “I” for more than 1 second, the UPS would detect whether the battery is connected or the battery is low immediately. Also the UPS could do the test automatically and periodically, the period time could be set by user, the default value is 7 days. 5.6 Turn off the UPS (1) In Inverter Mode: Press “ ” button continuously for more than 1 second to turn off the UPS, the UPS will get into no output or bypass mode. At this time, the UPS might has output if

  • 21 EN  NC Normally the EPO connector is closed with a wire on the rear panel. Once the connector is open, the UPS would stop the output until the EPO status is disabled. Enable the EPO status Disable the EPO status 5.3 Battery charge Fully charge the batteries of the UPS system by leaving the UPS system connected to

  • 32 EN 9. Maintenance 9.1 Operation The UPS system contains no user-serviceable parts. If the battery service life (3~5 years at 25°C ambient temperature) has been ex ceeded, the batteries must be replaced. In this case please contact your dealer. 9.2 Storage If the batteries are stored in temperate climatic zones, they should be charged every t

  • PowerWalker VFI 1000RT, 11 EN 1.3.1 UPS and Battery Care For the best preventive maintenance, keep the area around the UPS clean and dust-free. If the atmosphere is very dusty, clean the outside of the system with a vacuum cleaner. For long battery life, keep the UPS at an ambient temperature of 25°C (77°F) 1.3.2 Storing the UPS and Batteries When the UPS is intended to store for a long period, recharge the battery every 6 months by connecting the UPS to utility power. The batteries charge to 90% capacity in approximately 4 hours. However, it is recommended that the batteries charge for 48 hours after long-term storage. 1.3.3 Time to Replace

  • 27 EN 6.7 Converter mode In converter mode, on LCD display, the mode string is “CVCF”. The UPS would free run with fixed output frequency (50Hz or 60Hz) in converter mode. Once the mains is loss or abnormal, the UPS would transfer to battery mode and the load is supplied continuously by the battery. 1) It could be enabled through the LCD setting or the software (Winpowe

  • PowerWalker VFI 1000RT, 23 EN (3) The battery connection procedure is very important. Any incompliance may result in the risk of electric shock. Therefore, the following steps must be strictly complied with. (4) Make sure the mains input is cut off, if there is a battery breaker then turn it off first. (5) Remove front panel, connect the battery via Anderson PP45 connectors. Prepare the battery cable which should be able to carry the current of >50A for all models, the cross section area should be great t

  • PowerWalker VFI 1000RT, 5 EN  Rack-mount setup The series can be installed in 19 inches racks. Both the UPS and external battery enclosure need 2U of rack space. Use the following procedure to install UPS in a rack. 1. Align the mounting ears with screw holes on the side of the UPS, and tighten the screw. 2. Assemble the rack rails with the rack-mounting. 3. Slide in the UPS into the rack rail and lock it in the Rack-mounting. 4. Tighten the screw, and then the load can be connected. 1.1.4

  • 18 EN The LCD Display Display Function Display Function Input Information Output Information It indicates input voltage/frequency value, which are displayed alternately. It indicates output voltage/frequency value, which are displayed alternately. It indicates the input is connected with mains, and the input power is s

  • PowerWalker VFI 1000RT, 7 EN  Connecting the EBM in a rack form 1. Using the same method as assembling UPS in a rack form, assemble EBM into the rack-mounting on the top or bottom of the UPS. 2. Connect the earth line from UPS (port A ) to EBM (port B ) 3. Take off the LCD box, and unscrew the internal screws. 4. Take off the front panel, and connect the battery terminal (A) from UPS to EBM terminal (B) shown as below. Users need to remove the small gate(C) on side of the front panel to allow the outlet wire of the EBM to pass through the gate and then reassembl

  • PowerWalker VFI 1000RT, 16 EN 3. Introduction This On-Line-Series is an uninterruptible power supply incorporating double-converter technology. It provides perfect protection specifically for Novell, Windows NT and UNIX servers. The double-converter principle eliminates all mains power disturbances. A rectifier converts the alternating current from the socket outlet to direct current. This direct current charges the batteries and powers the inverter. On the basis of this DC voltage, the inverter generates a sinusoidal AC voltage, which permanently supplies the loads. Computers and periphery are thus powered entirely by the main

  • PowerWalker VFI 1000RT, 6 EN on side of the front panel to allow the outlet wire of the EBM to pass through the gate and then reassemble front panel. B A C B A

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chicago Electric 69820 Owner's manual & safety instructions chicago-electric/69820-QEM.pdf 07 Oct 2022 16
2 IntesisBox MH-RC-WMP-1 Installation manual intesisbox/mh-rc-wmp-1-BD6.pdf 11 Nov 2023 2
3 AOpen AX4SPE Max II Online manual aopen/ax4spe-max-ii-Q7G.pdf 27 Nov 2022 143 3.94 Mb
4 Linksys USB3GIG Operation & user’s manual linksys/usb3gig-334.pdf 16 Dec 2023 10
5 Karcher K 2.300 Operator's manual karcher/k-2-300-8P4.pdf 30 Jan 2024 12
6 Linksys CIT300 Quick installation manual linksys/cit300-59H.pdf 31 Dec 2023 2

Similar Resources:

  • ABB

    PowerValue 31/11 T 10 kVA

    (37 pages)
    4NWP100559R0001_OPM_ABB_PVA31-11-T_10-20kVA_EN_140626 Page 1/37 ABBModifications reservedPowerValue 31/11 T 10/20 kVAUser Manual4NWP100559R0001_OPM_ABB_PVA31-11-T_10-20kVA_EN_140626© Copyright 2014 ABB, All rights reserved. …
  • Integra

    Xmart OPTIMA-33 10K

    (44 pages)
    USER MANUAL – OPTIMA-33 10K/20K/30K www.xmart-ups.com 170502-OPTIMA-33 10K/20K/30K (ENGLISH) - 0 VER. 1705.02 ENGLISH USER MANUAL OPTIMA-33 10K/20K/30K UPS ONLINE DOUBLE CONVERSION – TOWER 3 PHASES INPUT / 3 PHASES OUTPUT 400/230V & 208/120V …
  • Nexsys

    600

    (57 pages)
    F R O M A L P H A T E C H N O L O G I E SNexsys System600, 900, 1250U N I N T E R R U P T I B L E P O W E R S U P P L I E SOperator’s Manual017-121-B0-002 05/99USA, LATIN AMERICA &ASIA PACIFICAlpha Technologies3767 Alpha WayBellingham, WA 98226Tel: (360) 647-2360Fax: (360) 671-4936UNITED KINGDOMAlpha TechnologiesCartel Business EstateEdin …
  • Tripp Lite

    SMART3000RM2UP

    (64 pages)
    1Owner’s Manual1111 W. 35th Street, Chicago, IL 60609 USA • www.tripplite.com/supportCopyright © 2014 Tripp Lite. All rights reserved. SmartPro® is a registered trademark of Tripp Lite.Español 22Français 43SmartPro® 2U RackmountIntelligent, Line-Interactive UPS Systems120V Sine Wave Output • 2200VA—3000VA CapacitiesSMART2200RM2U (Series Number: …
  • Emerson

    Liebert GXT3 6000VA RTL630

    (4 pages)
    1 SL-23185QS6L630_Rev0_09-2012 Liebert® GXT3™ Quick Start Guide – 6000VA RTL630 Models The Liebert GXT3 is shipped with the following items: • Terminal Block Communication terminals• Compact disc with:o Liebert MultiLink®o Configuration programo User manual (electronic version)• USB cable, one; 2m (6-1/2 ft.) long• Rack handles with mounting h …
  • Panduit

    UPS00100DC

    (46 pages)
    Page 1 of 46 IA-CD-0009 Rev: 07 09-2018 © Panduit Corp. 2018 UNINTERRUPTIBLE POWER SUPPLY (UPS) USER MANUAL UPS00100DC IA-CD-0009 Rev. 07 English NOTE: Throughout this document, the UPS00100DC (Uninterruptible Power Supply) may also be referred to as “UPS”. Email: [email protected] EU Website: www.panduit.com/emea 7 Technical …

Comments, Questions and Opinions: