Manualios.com

Sony PVM-741 Operating Instructions Manual

Sony PVM-741 Manual Online:

4.4, 2326 votes
Sony PVM-741 User Manual
Sony PVM-741 User Guide
Sony PVM-741 Online Manual

Text of Sony PVM-741 User Guide:

  • Sony PVM-741, Table of Contents 4 Table of Contents Precaution .............................................................. 5 On Safety ............................................................ 5 On Installation .................................................... 5 Handling the Screen ........................................... 5 On Burn-in ......................................................... 5 On a Long Period of Use .................................... 5 Handling and Maintenance of the Screen .......... 6 On Dew Condensation ....................................... 6 On Repacking ..................................................... 6 On Mounting on a Rack ......................

  • Sony PVM-741, Adjustment Using the Menus 25 WFM/ALM/VECTOR (waveform monitor, audio level meter, and vectorscope) SETTING Submenu Setting T/C Selects ON to display the time code display and OFF not to display. FORMAT Sets the time code format. • VITC: To display the time code in VITC format. • LTC: To display the time code in LTC format. POSITION Sets the position of the time code display. You can select between 1 and 2. • 1: Top • 2: Bottom TRANSPARENCY Selects BLACK or HALF (transparent) for the background of T/C display. • BLACK: The backgroun

  • Adjustment Using the Menus 20 Adjustment Using the Menus Items The screen menu of this monitor consists of the following items. STATUS (the items indicate the current settings.) FORMAT COLOR TEMP HDMI FORMAT NTSC SETUP SCAN MODE POWER SAVING I/P MODE Model name and serial number COLOR TEMP/SPACE COLOR TEMP MANUAL ADJUSTMENT COLOR SPACE USER CONTROL SUB CONTROL AUTO CHROMA/PHASE PICTURE CONTR

  • Sony PVM-741, Power Supply 15 Power Supply Attaching the AC Adaptor Attaching Removing CAUTION • The AC adaptor can be used only with products specified by the manufacturer. • To remove the AC adaptor, first unplug the AC power cord and then remove the AC adaptor. • Do not carry the monitor by holding the AC adaptor. Connecting the AC Power Cord Attach the AC adaptor to the monitor, and then connect the supplied AC power cord. Attach the AC plug holder to the AC power cord, and connect it to the AC IN connector so that the cord does not come loose. AC power cord (supplied) AC plug holde

  • Features 8 Timecode display Timecode superimposed on SDI signals is displayed on the screen. For more information, see “T/C (time code) DISPLAY SETTING” on page 24. Camera focus This function sharpens the edges of the image more than the amount set by the upper limit of the aperture value in the USER CONTROL menu. This is convenient for focusing with the camera. This func

  • Sony PVM-741, Selecting the Menu Language 17 2 If LATIN AMERICA is selected: 4 If ASIA EXCEPT JAPAN is selected: Customers who will use this unit in the shaded areas shown in the map below should select NTSC AREA. Other customers should select PAL AREA. 3 Press the menu selection control. The SELECT SETTING screen disappears and the menu item settings suitable for the selected area are applied. Note When you have selected the wrong area, set the following items using the menu. • COLOR TEMP (on page 21) • NTSC SETUP (on page 23) • COLOR SPA

  • Sony PVM-741, Using the Menu 18 The setting items (icons) in the selected menu are displayed in yellow. 4 Turn the menu selection control to select “LANGUAGE”, then press the menu selection control. The selected item is displayed in yellow. 5 Turn the menu selection control to select a language, then press the menu selection control. The menu changes to the selected language. To clear the menu Press the MENU button. The menu disappears automatically if a button is not pressed for one minute. Using the Menu The unit is equipped with an on-screen menu for making various adjustments and settings such as picture control, input setting, set setting change, etc. You can

  • Sony PVM-741, Adjustment Using the Menus 23 USER CONFIG menu The USER CONFIG menu is used for setting the system, marker, T/C display, WFM/ALM/VECTOR, focus, function button, closed caption, and audio. SYSTEM SETTING Submenu Setting NTSC SETUP Selects the NTSC setup level from two modes. The 7.5 setup level is used mainly in North America. The 0 setup level is used mainly in Japan. FORMAT DISPLAY Selects the display mode of the signal format and scan mode. • OFF: The display is hidden. • AUTO: The format and scan mode are displayed for about five seconds w

  • Sony PVM-741, Selecting the Default Settings 16 Selecting the Default Settings When you turn on the unit for the first time after purchasing it, select the area where you intend to use this unit from among the options. The default setting values for each area 1 Press the 1 (standby) switch. The unit is turned on and the SELECT SETTING screen appears. 2 Turn the menu selection control to select the area where you intend to use the unit and press the menu selection control. If you select either 1, 3 or 5 The confirmation screen is displayed. Confirm the selected area. When the

  • Sony PVM-741, Location and Function of Parts and Controls 9 Location and Function of Parts and Controls Front Panel a Tally lamp You can check the status of the monitor by the color of the tally lamp. The tally lamp lights in red, green or amber according to the setting of PARALLEL REMOTE in the REMOTE menu. b Protection plate You can detach the protection plate by removing the four screws. c i (headphones) jack The audio signal which is selected by the input select button is output in stereo sound. d Speaker The audio signal which is selected by the input select button is output in monaural sound (L + R). When SDI signals are input, the audio wh

  • Sony PVM-741, Location and Function of Parts and Controls 12 Rear/Bottom Panel a SDI (3G/HD/SD) input and output connectors (BNC) 1 (input) connector, 2 (input) connector Input connector for serial digital component signals. SDI 1 and SDI 2 inputs are available. OUT connector Output connector for serial digital component signals. Note • The signal from the OUT connector does not satisfy the ON-LINE signal specifications. • Output is only activated when the power is on. No output in standby mode. b COMPOSITE input and output connectors (BNC) IN connector Input connector for composite video signals. OUT connector Loop-through output connector.

  • Sony PVM-741, Adjustment Using the Menus 27 About the function assigned to the function button SCAN Press the button to change the scan size of the picture. With every press of the button, the picture switches in the sequence NORMAL scan t OVER scan t NATIVE (see “Scan mode image” on page 28). ASPECT Press the button to set the aspect ratio of the picture, 4:3 or 16:9. BLUE ONLY Press the button to eliminate the red and green signals. Only blue signal is displayed as an apparent monochrome picture on the screen. This facilitat

  • Sony PVM-741, Adjustment Using the Menus 29 right, bottom right and bottom left. The central area of the image is automatically framed when you select NATIVE. To select a display area 1 Press the function button to which the SCAN function is assigned and select NATIVE. The central part of the image will be displayed. 2 Turn the menu selection control to select the area to magnify. The areas you select will be toggled in the following order (turning the control in a clockwise direction). Note Changing input signals or formats automatically sets the magnified area to the center (default). 3 To return to standard v

  • Sony PVM-741, Installing the Handle 13 CAUTION • For safety, do not connect the connector for peripheral device wiring that might have excessive voltage to this port. Follow the instructions for this port. • When you connect the LAN cable of the unit to peripheral device, use a shielded-type cable to prevent malfunction due to radiation noise. • The connection speed may be affected by the network system. This unit does not guarantee the communication speed or quality of 10BASE-T/ 100BASE-TX. f HDMI input connector Input connector for HDMI signals. HDMI (High-Definition Multimedia Interface) is

  • Sony PVM-741, Adjustment Using the Menus 24 MARKER SETTING T/C (time code) DISPLAY SETTING SCREEN SAVER Sets the screen saver function on or off. • ON: If a still image is displayed for more than 10 minutes, the brightness of the screen is automatically decreased to reduce burn-in. The screen returns to normal brightness when you input an image to the unit or operate the buttons on the front panel of the unit. While the screen saver is activated, the LED of the selected input select button flashes. (To decrease the brightness of the LED, see �

  • Sony PVM-741, Adjustment Using the Menus 30 REMOTE menu PARALLEL REMOTE Submenu Setting SDI AUDIO SETTING Sets the audio channel when SDI signal is input. • 3G/HD/SD: Selects from among channels CH1 to CH16, odd channel + even channel (CH1+CH2, CH3+CH4···CH15+CH16) and OFF. You can display the L/R audio levels of the selected channels. (see “WFM/ALM/VECTOR (waveform monitor, audio level meter, and vectorscope) SETTING” on page 25). • SPEAKER OUTPUT: Select an audio format to output from speakers, headphone

  • 3 CAUTION The apparatus shall not be exposed to dripping or splashing. No objects filled with liquids, such as vases, shall be placed on the apparatus. CAUTION The unit is not disconnected from the AC power source (mains) as long as it is connected to the wall outlet, even if the unit itself has been turned off. WARNING Excessive sound pressure from earphones and headphones c

  • Sony PVM-741, Features 7 Features The PVM-741 Professional Video Monitor is a 7.4 type OLED panel monitor for broadcast or business use, featuring a precise image and high performance. This not only achieves high quality picture by the OLED panel but is also small and lightweight, and accepts a variety of input signals, making it useful in a variety of applications, such as an indoor/outdoor shooting, live production, editing, research and development. It features OLED panel and “TRIMASTER 1) ,” which is a new technology developed for three elements, “accurate color reproduction,” “precision imaging” and “

  • Sony PVM-741, Adjustment Using the Menus 21 Adjusting and Changing the Settings STATUS menu The STATUS menu is used to display the current status of the unit. The following items are displayed: •Signal format • Color temperature • HDMI format •NTSC setup •Scan mode • Power saving •I/P mode • Model name and serial number COLOR TEMP/SPACE menu The COLOR TEMP/SPACE menu is used for adjusting the picture white balance or color space. You need to use the measurement instrument to adjust the white balance. Recommended: Konica Minolta color analyzer CA-210/ CA-310 USER CONTROL menu The USER CONTROL menu is used for adjusting the picture. Ite

  • Sony PVM-741, Adjustment Using the Menus 28 An image with sharpened edges is displayed. T/C Press the button to display the time code display. Adjust the settings for the time code display in T/C DISPLAY SETTING (see page 24). SILENT MODE Press the button to stop the built-in cooling fan. Note Stopping the fan will result in a temperature increase inside the unit, possibly shortening the life of the unit. When you use SILENT MODE, the picture contrast decreases to 30, and the indicator flashes in green and amber alternately to protect the interior circuit. This is not a malfunction. FLIP V

  • Sony PVM-741, Installing the Arm Mount Bracket / Installing to the Rack (Using MB-531) 14 Installing the Arm Mount Bracket You can install the supplied arm mount bracket, using the supplied four screws. Installing to the Rack (Using MB-531) You can attach up to two monitors to the rack by using the optional MB-531 Mounting Bracket. 1 Attach the mounting bracket to the monitor. For details on attaching the mounting bracket, refer to the Mounting Instructions of the MB-531. 2 Attach the unit to the rack with four screws. Note The screw

  • Sony PVM-741, Specifications 33 Audio monitor output Stereo mini jack (× 1) Built-in speaker output 0.5 W Monaural Headphones output connector Stereo mini jack (× 1) General Power 100 V to 240 V AC, 0.5 A to 0.3 A, 50/60 Hz 12 V DC, 1.9 A Power consumption Approx. 30 W (max.) Inrush current (1) Maximum possible inrush current at initial switch-on (Voltage changes caused by manual switching): 51 A peak, 7 A r.m.s. (240V AC) (2) Inrush current after a mains interruption of five seconds (Voltage chan

  • Sony PVM-741, Specifications 34 Available signal formats The unit is applicable to the following signal formats. a : Adjustable/can be set – : Not adjustable/cannot be set *1 Compatible with 1/1.001 frame rates. *2 1080/24PsF, 25PsF, and 30PsF are displayed as 1080/48i, 50i, and 60i on the screen, respectively. *3 10-bit 4:4:4 Y/Cb/Cr and 4:4:4 RGB of 3G-SDI signals are supported. *4 10-bit 4:2:2 Y/Cb/Cr of 3G-SDI signal is supported. *5 10-bit 4:4:4 Y/Cb/Cr of 3G-SDI signal is supported. System Compo site SD/HD 3G HDMI 575/50i (PAL) aa – a 480/60i (NTSC)* 1 aa – a 576/50p – – – a 480/60p* 1 – –– a 640 × 480/60p* 1 –––a 1080/24PsF* 1 * 2 – aa* 3 – 1080/

  • Adjustment Using the Menus 22 Submenu Setting SUB CONTROL Adjusts finely the adjustment range of the function buttons which BRIGHTNESS is assigned. • BRIGHTNESS: Adjusts the picture brightness. • APERTURE: Adjusts the picture sharpness. The higher the setting, the sharper the picture. The lower the setting, the softer the picture. APERTURE does not work when the camer

  • Precaution 5 Precaution On Safety • Operate the unit only with a power source as specified in the “Specifications” section. • A nameplate indicating operating voltage, etc., is located on the rear and bottom. • Should any solid object or liquid fall into the cabinet, unplug the unit and have it checked by qualified personnel before operating it any further. • Do not dr

  • Sony PVM-741, Adjustment Using the Menus 31 KEY INHIBIT menu You can lock the setting so that they cannot be changed by an unauthorized user. Select OFF or ON. If you set to ON, all items are displayed in black, indicating the items are locked. FORCED TALLY The tally lamp function is forcibly assigned to 7 pin and 8 pin of the PARALLEL REMOTE connector. Selecting ON assigns tally lamp green to 7 pin and tally lamp red to 8 pin. ON: Forcibly assigns the tally lamp function. OFF: The tally lamp function is not forcibly assigned. Note When OFF is selected, any listed functions can be assigned to 7 and 8 pins. Selecting ON with any function other than the tally lamp assigned to 7 and 8 pins

  • Sony PVM-741, Location and Function of Parts and Controls 10 You can assign various functions in FUNCTION BUTTON SETTING of the USER CONFIG menu. Press the button BRIGHTNESS, CONTRAST, CHROMA, VOLUME, PHASE, or APERTURE function assigned to display the adjustment screen. Press the same button again, and the adjustment screen disappears, but you can adjust the value without the setting value display. For details of the function assigned to the function button, see page 27. h Menu operation buttons Di

More Instructions:

DOWNLOAD

Related Products and Documents (Baby Monitor):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Clifford 4000 Owner's manual clifford/4000-N1T.pdf 23 May 2023 25 0.11 Mb
2 Lenovo ThinkPad Edge E130 Operation & user’s manual lenovo/thinkpad-edge-e130-59K.pdf 25 Jun 2023 156
3 Koolatron P-25 FUN KOOL Owner's manual koolatron/p-25-fun-kool-UIQ.pdf 09 Feb 2024 2
4 iNetVu 5000 Operation & user’s manual inetvu/5000-J42.pdf 13 Aug 2023 77
5 eMachines G625 Guía rápida emachines/g625-1Q3.pdf 25 Nov 2023 13 1.65 Mb
6 Panasonic SL-1200MK2 Service manual panasonic/sl-1200mk2-SXI.pdf 12 Jan 2023 39 3.6 Mb

Similar Resources:

  • Motorola

    MBP85CONNECT

    (290 pages)
    USER’S GUIDEWi-Fi® Video Baby Monitor CameraModel: MBP85CONNECTThe features described in this user’s guide are subject to modifications without prior notice. …
  • Motorola

    MBP35

    (2 pages)
    MBP35 - Quick Start GuideFor a full explanation of all features and instructions, please refer to the User's Guide.1 Setting up your digital baby monitorRemoving the coversA• Turn the battery cover screws 90 degrees in a counterclockwise direction.• Lift off the battery covers.90° MAX Installing the batteries for the Baby unitB• Use only AA no …
  • Philips

    SBCSC361

    (2 pages)
    SC361SBCbaby monitorpilot tone technologyincluded• Pilot tone for interferencereduction• Battery-low indication onboth units• Fully cordless reliable babymonitor•Talk-button on baby unit tomanually talk to the parentunit• Range up to 150min open air• One adapter included …
  • Beurer

    JBY 84

    (92 pages)
    JBY 84D Babyphone GebrauchsanweisungG Baby monitor Instruction for UseF Babyphone Mode d’emploiE Intercomunicador para bebé Instrucciones para el usoI Babyphone Instruzioni per l’usoT Bebek telsizi Kullanma Talimatır Радио-няня Инструкция по применениюQ Elektroniczna niania Instrukcja obsługiBeurer GmbH • Söflinger St …
  • Hisense

    Babysense 5s

    (2 pages)
    Infant Movement Monitor 5SSensor | Do not use | SensorSlotIllustration 6Sensor | Do not use | SensorHanging hookBlue movement indicator lightRed alert alarm lightRed low battery warning lightOn/OffbuttonIllustration 8Speaker ControlUnitCable CableBed/Crib baseControl unit holderIllustration 5132Ensure you read this user guide before installing and using the …
  • Philips

    SBCSC463/00

    (160 pages)
    SCD463User manual 4Mode d’emploi 16Instrucciones de manejo 28Bedienungsanleitung 40Gebruiksaanwijzing 52Istruzione per l’uso 64Manual de utilização 76Od  88Bruksanvisning 100Vejledning 112Bruksanvisning 124Käyttööhje 136Kullanım talimatları 148TRSUNODKSVGRPRITNLDEESFREN …

Baby Monitor Instructions:

Comments, Questions and Opinions: