Manualios.com

Sawo STR45-1 Manual Manual

Sawo STR45-1 Manual Online:

4.1, 1855 votes
Sawo STR45-1 User Manual
Sawo STR45-1 User Guide
Sawo STR45-1 Online Manual

Text of Sawo STR45-1 User Guide:

  • Sawo STR45-1, 1. 2. 3. 4. 5. Children under the age of 16 should not use the Steambath. Check with a physician before use of the Steambath if you are pregnant, have a coronary condition, are in poor health, are being treated for any other medical condition, or are using medication or drugs. Exit Steam Room immediately if you feel faint, dizzy, sleepy, or otherwise uncomfortable. Do not use the Steambath if you have recently consumed alcohol. Condensation and moisture may cause the the Steambath floor and other surfaces to become slippery and dangerous. Installation of non-skid floor materials or the use of proper footwear is recommended at all times. IMPORTANT! Read the manual provided for use

  • Sawo STR45-1, 2 TABLE OF CONTENTS STR75-3 STR90-1 STR90-3 STR120-3 STR150-3 MODELS: STR45-1 STR45-3 STR60-1 STR60-3 STR75-1 Residential Steambath Generator Systems Installation, Operation & Maintenance Manual This highlights information that is especially relevant to a problem-free installation. IMPORTANT NOTE: signals a situation where minor injury or product damage may occur if you do not follow instructions. ! CAUTION IMPORTANT NOTE: As you follow these instructions, you will notice warning and caution symbols. This blocked information is important for the safe and efficient in

  • Sawo STR45-1, NOTE: For illustrative purposes only. Consult with qualified designer, architect or contractor for steam room construction details. Provide unions as required to facilitate installation and disconnect of piping Steam generator Field installed power supply Field installed steam supply pipe Valve is shown open Control cable Steam Head (shown with optional acrylic shield) SAWO in-shower control Temperature sensor F ield installed water supply pipe 4 Locating the Steam Generator ! WARNING 1. 2. 3. 4. 5. 6. 7. 8. 9. 10

  • Sawo STR45-1, NOTE: For illustrative purposes only. __________________________________________ NOTES: 1.M= Optional Automatic drain 2. All units in millimeters (mm) STR120-3 and STR150-3 STR45-1, STR45-3, STR60-1, STR60-3, STR75-1, STR75-3, STR90-1 and STR90-3 A 140 184 __________________________________________ B 210 254 __________________________________________ C 302 310 __________________________________________ D 375 466 __________________________________________ E 45 152 __________________________________________ F48 64 __________________________________________ G 89 102 __________________________________________ H 127 152 __________________________________________ I 171 200 _____

  • Sawo STR45-1, 9 Wiring Diagrams FACTORY WIRING FIELD WIRING LEGEND All Diagrams INPUT SINGLE PHASE STR45-1, STR60-1, STR75-1, STR90-1 THREE PHASE STR45-3, STR60-3, STR75-3, STR90-3 STR120-3, STR150-3 CONTROL BOARD S AWO 230 VOLT S S ING L E P HA S E WIR ING DIAG R AM WATER FEED SOLENOID VALVE S LIGHT BLUE CONTACTOR WHITE GRAY HEATING ELEMENT WHITE C TRANSFORMER GROUND DARK BLUE WHITE BLACK LN BLACK G GREEN POWER TO PROBE TEMP SENSOR SAWO CONTROL AUTOMATIC DRAIN DA RK BLUE CONTROLBOARD WHITE SAWO 415 VOLT S THRE E PHASE WIRING DIAGRAM GROUND CONTACTOR C S GRAY HEAT ING

  • Sawo STR45-1, Optional Tandem Cable - for connecting 2-5 steam generators in tandem 1. Turn on control. Follow specific instruction sheet provided with controls. 2. Steam will begin to appear in 5 minutes at the steam head. Steam will shut off when desired temperature is reached and will automatically resume when room temperature drops below set point. 3. Steam will shut off automaticaly when control counts down to zero. to shut steam off manually, turn control OFF. To clear steam from enclosure area, turn shower on before opening door. 4. If unit does not start and control does not turn ON (control display does not light

  • Sawo STR45-1, Using Aroma Oils Sweat Fittings When using sweat fittings use only tin base solder with a melting point below 315ºC. Do not overheat. Ends of water supply tubing must be thoroughly cleansed for a minimum distance of 25mm from ends. Do not remove valve cover. To Check Operation 1. Turn on SAWO and allow tank to fill with water. 2. Turn off SAWO control. Water should stay in tank. 3. Turn off power at the panel box. Water should discharge from tank. 4. Turn on power at panel box. 5. Repeat. PROVIDE DRAIN PLUMBING ACCORDING TO LOCAL REQUIREMENTS. PLUMB AS REQUIRED FOR GRAVITY DRAIN SYSTEM. Aroma oil 10ml

  • Sawo STR45-1, 14 STR45-1, STR45-3, STR60-1, STR60-3, STR75-1, STR75-3, STR90-1 and STR90-3 (with Automatic drain) shown with cover removed NOTE: For illustrative purposes only. Some components may be omitted or altered for clarity. Do not use for wiring, repair or other purposes not related to component identification. Models STR45-1, STR45-3, STR60-1, STR60-3, STR75-1, STR75-3, STR90-1 and STR90-3 are compatible with SAWO Controls and include a matching steam head. The weight is 21 kg per unit. Single Phase wiring shown Power Block Power Supply Knock-Out Liquid Level Probe Access Cover Heating Element Stainless Steel Tank Drain Line Automatic dr

  • 16 Diagram 1 Installing the Remote Temperature Probe for SAWO Controls Diagram 2 DRAWING NOT TO SCALE SAWO Steam Generator (shown with cover removed and NOT installed) Temperature Sensing Probe Knock-out Temperature Probe Cable (9 meters) Temperature Probe Connection Printed Circuit Board Component shown for illustrative purpose The Remote Temperature Probe is for use with SA

  • 18 1. Use only mild soap and water on a soft cloth to clean the control. Care Tips for Control 2. Do not use abrasive cleansers N Step 1 Step 2 Do not oversize or undersize the hole. Step 3 Step 4 67 mm 25 mm 25 mm A B C D Wall Wall Do not route the control or temperature sensor wiring inside conduit together with power lines or close to hot water or steam pip

  • Sawo STR45-1, • • • • 20 ON/OFF Key is used to turn the steam generator on/off. Press On/Off key to turn steam generator on. Press a second time to turn steam generator off. A built-in timer automatically shuts the steam generator off a predetermined period of time after it has been started, unless the user does so manually. The "Display" indicates the Set Point temperature. Pause key is used to turn the steam generator off momentarily. Press Pause key to activate stand-by mode. Press a second time to resume normal function. The "Set Point" indicator will flash on the function panel when Pause feature is activated. Up & Down arrow keys are used to set a

Related Products and Documents (Portable Generator):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Cub Cadet RZT42 Operator's manual cub-cadet/rzt42-5CD.pdf 06 May 2023 76 11.81 Mb
2 American Dynamics ADMNM1LCD15 Specifications american-dynamics/admnm1lcd15-WZB.pdf 26 May 2023 2 0.4 Mb
3 AEG FAVORIT 448 i Operating instructions manual aeg/favorit-448-i-W5K.pdf 25 Sep 2023 24 0.67 Mb
4 Toshiba Satellite Pro S300-EZ1514 Specifications toshiba/satellite-pro-s300-ez1514-LBT.pdf 09 Feb 2023 5 0.07 Mb
5 Frigidaire FEB27S6D Factory parts catalog frigidaire/feb27s6d-3FJ.pdf 01 Feb 2023 10 0.65 Mb
6 Crunch G12 Owner's manual crunch/g12-5KV.pdf 27 Feb 2024 8 1.9 Mb

Similar Resources:

  • Haug

    Static Series

    (21 pages)
    @r'NetzteilENSL/ENSLLC/ENSLRLCBedienungaanleltungOperating instruciionsMode d'emploilstruzionl per l'usolnslruccionea de uaoManual de Inslrue6estr@Tf:tBFR[1rESFlr …
  • Firman

    W03661OF

    (126 pages)
    P/N:336745481 Rev:01OPERATOR’S MANUALGASOLINE INVERTER GENERATORRecord product information to reference when ordering parts or obtaining warranty coverage.MODEL NUMBERW03661OFRev Level:00 …
  • Polaris

    Power P1000i

    (80 pages)
    PMS 419 P1000iP2000iOperator’s Manual(Australian models) Failure to properly follow the instructions and precautions in this manual can result in property damage, serious injury or DEATH!For your nearest Polaris supplier, call 0393945610or visit www.polarispower.com.auPolaris Sales Australia Pty Ltd.,(ABN 62088081949) of Locked Bag 2006,Sunshine Post Shop …
  • A-iPower

    SUA9000E

    (29 pages)
    OWNER'S MANUAL & OPERATION INSTRUCTION9000 Starting Watts7000 Running WattsPORTABLE GENERATORThis manual contains important information regarding safety, operation, maintnance and storage of this product. Before use, read carefully and understand all cautions, warnings, instructions and product labels. Failure to do so could result in serious perso …
  • Mitsubishi Electric

    9700 Series

    (65 pages)
    9700 100-225 Revision 3.31: Feb. 4, 04 ALN-H0153 MITSUBISHI ELECTRIC AUTOMATION, INC. UNINTERRUPTIBLE POWER SUPPLY SYSTEM 9700 SERIES OWNERS / TECHNICAL MANUAL ( 100 - 225kVA ) …
  • EINHELL

    TE-CD 18 Li BL-Solo

    (164 pages)
    TE-CD 18 Li BL-SoloTE-CD 18 Li BLArt.-Nr.: 45.138.50 (Solo) I.-Nr.: 11029Art.-Nr.: 45.138.51 (2x2.0 Ah) I.-Nr.: 110297D Originalbetriebsanleitung Akku-BohrschrauberGB Original operating instructions Cordless drill/screwdriverF Mode d’emploi d’origine Perceuse sans fi lI Istruzioni per l’uso originaliTrapano avvitatore a batteriaDK/ Original …

Comments, Questions and Opinions: