Manualios.com

FDC 5i Taper Installation And Operating Instructions Manual

  • 5i Taper Cooktop
  • ma0WKp/Szbpq6
  • Installation And Operating Instructions Manual
  • PDF / Adobe Acrobat Reader
  • 20

FDC 5i Taper Manual Online:

3.25, 2743 votes
FDC 5i Taper User Manual
FDC 5i Taper User Guide
FDC 5i Taper Online Manual

Text of FDC 5i Taper User Guide:

  • FDC 5i Taper, DEFRA Clean Air Act Exemption The FDC 5i Taper stove has been exempted under the Clean Air Act 1993 to burn seasoned wood logs in designated smokeless zones in the UK. This is subject to the correct fitting of the air control plate (the part and fitting instructions are supplied separately) maintaining the air wash control above a minimum setting at all times. Instructions for wood burning MUST be followed in order to ensure compliance at all times. FDC 5i Taper INSET STOVE 5 kW

  • FDC 5i Taper, 1 FDCiT Issue 03 10/14 PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY! For safety reasons it is essential that your stove is correctly installed and operated. FDC cannot accept responsibility for any fault or consequential problems arising through incorrect installation or operation. TABLE OF CONTENTS Section Page No 1. List of Components 2 2. Component Identification and Assembly 2 3. Installation Instructions 3 3.1 Warnings and important safety information 3 4 Installation Information

  • 2 FDCiT Issue 03 10/14 1. List of Components Description of Parts Qty FDC 5i Taper Stove Assembly 1 Multi Tool 1 Ash Pan 1 Flue Spigot Collar 1 Spigot Collar fixing screws & nuts 3 Stove Operating Gloves 1 2. Component Identification and Preparations for Installation Your stove comes packed in a plywood c

  • FDC 5i Taper, 3 FDCiT Issue 03 10/14 2.5 To remove the door first release the 8 screws behind the door holding the metal wrap around trim to the firebox. When the trim is free the door can be lifted off its pins and placed out of the way. 2.6 Remove the metal outer trim to expose the firebox itself. 2.7 Remove the inner firebox from the outer firebox by releasing the 4 x countersunk screws from the support blocks each side of the firebox. 2.8 Place the inner firebox into the opening and drill and secure through the base to the hearth or into the wall/back pa

  • FDC 5i Taper, 4 FDCiT Issue 03 10/14 3.1.5 Fuels Only use recommended fuels which are seasoned (or kiln dried) wood logs or smokeless briquetted fuels. The appliance can be damaged by burning petroleum coke, liquid fuels or general rubbish and this will invalidate your warranty and risk your personal safety. The appliance must not be used as a rubbish incinerator. 3.1.6 Maintenance Annual checking and servicing of the appliance and flue by a competent engineer is recommended. 3.1.7 Ventilation Adequate ventilation is ESSENTIAL for the safe and ef

  • FDC 5i Taper, 5 FDCiT Issue 03 10/14 If you have any doubts about the suitability of your chimney, consult your local dealer/stockist or chimney specialist. If there is no existing chimney then either a solid fuel compatible prefabricated block chimney or a twin-walled insulated stainless steel flue to BS 1856 can be used. These chimneys must be fitted in accordance with the manufacturer’s instructions and Building Regulations. 4.2 Ventilation Purpose provided ventilation is not required in England and Wales unless the appliance nominal rated output is greater than 5kW. Over 5kW 5.5 cm 2 of ven

  • FDC 5i Taper, 6 FDCiT Issue 03 10/14 4.6 Material Clearances Safety Distances from Combustible Surfaces: Model Side 150mm Shelf 150mm Shelf - WITH TOP DEFLECTOR FDC 5i T 150mm 400mm 125mm A stove top deflector heat shield is supplied with every stove to provide help for combustible shelves or surrounds that are closer than ideal to the stove top. With the deflector fitted a 6” combustible shelf can be maintained at minimum 125mm (5”) from the stove top. Fitting this part is optional and it does not affect stove operation at all. In addition it is strongly recommended tha

  • FDC 5i Taper, 7 FDCiT Issue 03 10/14 Advise the customer not to run the stove at full output for at 3 – 4 days. Explain that the stoves can provide much more or less than their rated heat outputs depending upon how they are burnt and fuels and fuel loads used. Warn the customer that using excessive air (having the air controls open too wide for too long) can over-fire and irreparably damage the stove. Damage caused by over firing is NOT covered by any warranty. On completion of the installation and commissioning, check that all parts of the appliance are correctly fitted and ensure that the operating instructio

  • 8 FDCiT Issue 03 10/14 5.0 Technical Data & declaration of Performance (DoP) Manufacturers authorised Representative: FDC UK Ltd, Dinton Business Park, Dinton, Salisbury, SP3 5HZ. Manufactured By: Charlton & Jenrick Ltd, Telford, TF3 3AR Range Designation: FDC Taper Inset Stove Range Models: FDC 5 Inset Taper with nominal output of 5kW. Intended Use: Dome

  • 9 FDCiT Issue 03 10/14 Operating Instructions This appliance is not designed for open operation and therefore should not be operated with the doors open. This stove is designed to burn wood and smokeless fuels cleanly with high efficiency. However, for this product to work properly it must be used correctly. If used correctly this stove will burn with the very u

  • FDC 5i Taper, 10 FDCiT Issue 03 10/14 This provides a conventional air draught to the bed of the fire. The primary air intake needs to be adjusted to give the best results when burning different fuels. It will usually be closed when burning wood fuel and open when burning coal or smokeless type fuels. Secondary Air (Air Wash) FDC Taper stoves are provided with a sophisticated patented “air wash” system. This secondary air supply to the stove is controlled through a slider assembly located on the top right hand side of the stove. If you want clean glass, always leave this control open some way whilst bur

  • FDC 5i Taper, 11 FDCiT Issue 03 10/14 Baffle: It is essential to check the top of the baffle for build up of soot and ash regularly when in use and after a long period of no use. From time to time remove the baffle if necessary to ensure that the flue way entrance is clear. 6.4 Fuels The appliance is fitted with a versatile multifuel grate and the appliance has been tested and approved burning dry, well-seasoned logs or Ancit smokeless fuel. These are the recommended fuels. For all other fuels please contact th

  • FDC 5i Taper, 12 FDCiT Issue 03 10/14 6.5.4 Primary Air left open Operation with the primary air controls left open can cause excess smoke. The appliance must not be operated with air controls or door left open. 6.6 Notes on Smokeless Fuel (Ancit) burning Ancit, smokeless and coal type fuels require very different burning conditions to log burning. When the stove is established and burning well, the air wash can be closed fully and the burning rate controlled with the primary air control and refuelling to obtain maximum efficiency. Ancit and other smokeless briquetted fuels c

  • FDC 5i Taper, 13 FDCiT Issue 03 10/14 Loading 3 to 4 medium sized logs will produce a good output with reasonable burn time, generally small logs will burn up quicker producing a high output for a short time and a large log will take longer to burn and produce less output over a given time. These appliances are approved for intermittent operation on wood (0.75 to 1.5 hour burn cycles) although much longer burn times can be achieved by fully loading the firebox, getting the fuel burning well and then shutting the

  • FDC 5i Taper, 14 FDCiT Issue 03 10/14 7.0 Safety Notes for your guidance FIRES CAN BE DANGEROUS – Always use a fireguard to BS 8423:2002 Fireguards for use with solid fuel appliances in the presence of children, the elderly or the infirm. DO NOT perform modifications to the appliance as this could seriously compromise safety in operation. DO NOT OVERFIRE – it is possible to fire the stove beyond its design capacity, this could damage the stove, so watch for signs of over firing – if any part of the stove starts to glow red, including baffle plate or f

  • FDC 5i Taper, 19 FDCiT Issue 03 10/14 9.0 Frequently Asked Questions 1 Do stoves require a chimney? All of our multi fuel and wood burning stoves require a suitable chimney or professionally installed flue system. 2 How do I clean the chimney? You will require a chimney sweep to clean the chimney. It is essential to provide a dedicated chimney cleaning access door when installing the flue of the stove in some situations. In other situations the chimney can be swept through the firebox. 3 Who should install my sto

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Chevrolet SUBURBAN 1993 Owner's manual chevrolet/suburban-1993-A66.pdf 17 May 2023 386 21.78 Mb
2 Akura APLDVD1968UCR Operation & user’s manual akura/apldvd1968ucr-696.pdf 24 Feb 2023 31 3.01 Mb
3 Qstarz BT-Q800 Quick installation manual qstarz/bt-q800-TZ9.pdf 19 Feb 2023 2 0.2 Mb
4 RBH Sound MCS-88 Installation and instruction manual rbh-sound/mcs-88-3D4.pdf 10 Sep 2023 4 0.36 Mb
5 Sharp R-957M Operation manual sharp/r-957m-667.pdf 31 Dec 2022 49 2.2 Mb
6 Trimble SK8 Reference manual trimble/sk8-7EI.pdf 03 Apr 2024 212 1.16 Mb

Similar Resources:

  • GE

    JBP72KKCC

    (2 pages)
    †Note: Check local codes for required breaker size.Effective January 1, 1996, the National Electrical Code requires that new construction (not existing) utilize a 4-conductor connection to an electric range.Receptacle Locations: Locally approved flexible service cord or conduit must be used because terminals are not accessible after range installation. Se …
  • Frigidaire

    FEF375F

    (9 pages)
    FEF375FC.eps T20G0065.eps T20V0088.eps T20T0053.eps T20D0035.eps 316255121d.eps 316255121s.eps Product No. FEF375FCA Series 30" f/s elec Color stainless Market North America Owner's Guide 316417003 Installation Instructions 316454901 Service Data Sheet 316441438 Electrolux Major Appliances North & Latin America P.O. BOX 2 …
  • Taurus

    White & Brown DARKFIRE

    (54 pages)
    DARKFIREDARKFIRE DOUBLEPlaca de inducción portátilPortable induction platePlaque à induction portableInduktionskochplattePia󰀬ra a induzionePlaca de induçao portátilPlaca d’inducció portàtilInductie fornuisPłyty indukcyjna Επαγωγική πλάκαИндукционная плита Placa a InductieИндукционна плоча974671_IM.i …
  • Electrolux

    ECCI3668AS

    (4 pages)
    NOTICE - This service data sheet is intended for use by persons having electrical and mechanical training and a level of knowledge of these subjects generally considered acceptable in the appliance repair trade. The manufacturer cannot be responsible nor assume any liability for injury or damage of any kind arising from the use of this data sheet.SAFE SERVIC …
  • Whirlpool

    GW397LXU

    (1 pages)
    ®30" Slide-in Gas RangePRODUCT MODEL NUMBERS OVERALL DIMENSIONSCABINET OPENING DIMENSIONSCOUNTERTOP PREPERATIONGW397LXUGW399LXUBecause Whirlpool Corporation policy includes a continuous commitment to improveour products, we reserve the right to change materials and specifications without notice.Dimensions are for planning purposes only. For complete d …
  • Frigidaire

    FES388WGC

    (2 pages)
    Product / Produit: Slide-in / Cuisinière EncastrableBrand / Marque: Frigidaire Pro-GalleryModel No. / No. Modèle: FES388WGCRef. No. / No Ref.: 379-57-396H8-36Yearly Quantity / Quantité Annuelle: 800Prod. Target Date / Date de Prod. Cible: 98 / 01Control FeaturesCaractéristiques de commandePanel / Panneau:Aluminum Brush Met 134 / Aluminium Brossé Met 134 …

Comments, Questions and Opinions: