  • IDS LCD Digital Keypad, 21 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.3.5.11 Fire Code (Not applicable to the IDS 1224 & IDS 816) If enabled ,this option allows reporting of a Fire Code. In the event that this code is reported, all fire doors will be automatically opened. 8.3.6 Option 5 - Assign User Code to Partitions Hold [*]

  • IDS LCD Digital Keypad, 8 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 1. Introduction to the IDS LCD Digital Keypad Your installer has selected one of the finest alarm systems available for your installation and has custom programmed the system features to meet your specific requirements. The elegant and user friendly LCD Keypad will allow you easy access to your security system's functions and information at the touch of a button. The 32 character screen will display menus and messages to guide you through the system's operation. Since you will communicate your instructions to your system th

  • IDS LCD Digital Keypad, 19 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 Table 4 : User Code Properties Zone LED Property 816 1224 1632 1 Master User X X X 2 Duress Code X X X 3 Arm to Disarm Code [Maid‟s Code] X X X 4 Group Arm (Global Arm /Disarm for 816) X X X 5 Group Disarm X X 6 Arm Code X X 7 Disarm Code X X 8 Report User Open Close X X 9 User Phone in Access X X 10 Report User Access X 11 Enable Anti-pass back for User X 12 Fire Code X Explanation of User Code Properties 8.3.5.1

  • IDS LCD Digital Keypad, 15 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.1 Adding, Deleting and Editing User Codes Hold [*] + [MASTER USER CODE] + [*] + [PROGRAMMABLE OPTION] + [*] All IDS Alarm Panels utilise a user-friendly programmable interface which allows the user to add, modify, or delete user codes. See Table 3 for a summary of programmable options. The programmable interface is accessed by entering the USER PROGRAMMING MODE. Table 3 : User Programming Options Options Summary of Programmable Options 816 1224 1632 Option 0 Allows for the addition of new user codes. x x x Optio

  • IDS LCD Digital Keypad, 6 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.3.5.11 Fire Code................................................................................................................21 8.3.6 Option 5 – Assign User Code to Partitions.............................................................21 8.3.7 Option 6 – Assign User Code to Doors..................................................................21 8.3.8 Option 7 – Assign User Code to Schedule.............................................................22 8.3.9 Option 8 – Adding User Remotes.......................................................

  • IDS LCD Digital Keypad, 23 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.3.10 Option 9 - Delete User Code (Code known) Hold [*] + [Master Code] + [*] + [9] + [*] + [User Code to be deleted] + [*] 1. Enter the User Program Mode as per steps 1 - 4 of (8.2). 2. IDS 816 Panel When prompted for the 'Menu Option' press the [9] key followed by the [*] key to select programmable option 9. IDS 1632 & IDS 1224 Panels Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To selec

  • 20 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 disarmed, entering a global code at the keypad of the armed partition will disarm that partition and entering a global code at the keypad of the disarmed partition will arm that partition. 8.3.5.5 Group Arm (N

  • IDS LCD Digital Keypad, 26 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 3. Press the [NUMBER] corresponding to the zone you wish to be programmed as a Buzz zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones. 4. A [Y] next to the zone number indicates that the zone has been programmed as a Buzz zone. Flashing text indicates a Stay zone. A zone cannot be both a Buzz and Stay Zone and a Stay zone cannot be selected as a Buzz zone. 5. Repeat step 3 until all the required buzz zones are programmed. 6. Press the [#] key to exit the buzz programming mode.

  • 17 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 3. The ARM indicator flashes and the LCD prompt reads ' Enter User Code'. 4. Enter the [USER CODE] that you wish to edit. User Names are displayed as the User Slot Number by default. Edit the User Slot Number so that it reads the correct User Name. (See Notes on Editing a User Name). 5. To confirm

  • IDS LCD Digital Keypad, 16 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 IDS 1632 & IDS 1224 Panels The first menu option - Menu Option 0 - 'Add User' is displayed by default. 6. Select a programmable option from Table 1. In the case of the IDS 1632 and IDS 1224, one may use the [PANIC] or [MED] keys to scroll through the menu options. 7. Confirm the entry by pressing the [*] key. A valid entry is confirmed by a long beep. An invalid entry will be signalled by means of an error beep (3 short beeps). If an error beep occurs, press the [#] key to clear all previous entries, and rep

  • 31 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 Quick Reference User Guide Description Programming Add a User Code [*] [Master Code] [*] [0] [*] [New Code] [*] Change a User Code [*] [Master Code] [*] [2] [*] [Old Code] [*] [New Code] [*] View a Slot Number [*] [Master Code] [*] [3] [*] [User Code] [*] View the Slot number via the zone LED‟s Edit U

  • IDS LCD Digital Keypad, 25 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 1. Select the required stay profile (See 9.1) 2. Hold down the [3] key until the keypad buzzer sounds. The LCD keypad will indicate that the panel is in Stay mode alongside the partition number. 3. Press the [NUMBER] corresponding to the zone you wish to be a STAY zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones. 4. A [Y] next to a zone number indicates that that particular zone is programmed as a stay zone. NOTE: Buzz zones will be shown by flashing indicators. (See Section 8). A Buzz zone cannot be selec

  • IDS LCD Digital Keypad, 14 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 IDS 1224 1 - 24 12 IDS 1632 1 - 32 12 For detailed programming instructions, please see the installation manual provided with your Alarm Panel. 1. Press [#] + [INSTALLER CODE] + [*]. If the default installer code is four digits it will be [9999], if it is six digits, it will be [999999]. 2. Enter the [LOCATION] as per table 1 above followed by the [*] key. 3. Enter the [SUB-LOCATION 12] followed by the [*] key. 4. Edit the Zone Name. Notes on Editing a Zone Name  Use the [MODE] key to toggl

  • IDS LCD Digital Keypad, 9 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 If the partition is already STAY armed, this key will initialize AWAY arming. It is therefore possible to change directly from STAY armed to AWAY armed. 2.2 Stay Arming Stay arming allows the user to monitor selected perimeter zones and bypass interior zones. The user can remain on the premises with access to designated areas during the STAY ARM cycle. Any zone whi

  • IDS LCD Digital Keypad, 13 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 5.3 Medical Alarms [M] (Hold down the [M] key for two seconds until the keypad buzzer sounds)  If the [M] key is pressed until the keypad beeps (approximately 2 seconds) a MEDICAL ALARM condition will be activated.  The keypad buzzer will beep 5 times.  A medical reporting code will be reported to the monitoring company. 5.4 Duress Al

  • IDS LCD Digital Keypad, 27 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 11.2 How to Cancel Chime Zones HOLD [2] + [ZONE NUMBER] + [*] + [#] 1. Hold down the [2] key until the keypad buzzer sounds. 2. The LCD display will indicate that you are in chime mode. 3. To cancel any chime zones, press the key corresponding to that zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones. 4. An

  • IDS LCD Digital Keypad, 12 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 4.2 How to Un-Bypass a Zone Hold down [9] + [ZONE NUMBER] + [*] + [#] 1. Enter bypass mode by holding down the [9] key until the keypad buzzer sounds. The power and arm LED's will be off. All zones will be displayed on the screen with either a [Y] or a [N] alongside the zone. 2. [Y] indicates that the zone has been bypassed, whilst [N] indicates that the zone has not been bypassed. 3. Press the number corresponding to the currently bypassed zone, then press th

  • IDS LCD Digital Keypad, 10 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 The LCD display will read 'Partial Arm' and will indicate any zones which have been bypassed. One is able to scroll through the list of bypassed, as well as violated, zones by using the [PANIC] and [MED] keys. 2.3 How to Stay Arm and Go (Hold down the [6] key for two seconds until the keypad buzzer sounds) This is a single key arm function, which allows the user to STAY arm and leave the premises. If a partition is already stay armed, holding down the [6] key initiates an exit delay,

  • IDS LCD Digital Keypad, 22 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 Example: If a user is assigned to door 1, there will be a [Y] next to Option 1 and the user can thus open door 1. If the user is assigned to door 14 there will be a [Y] next to Option 14. It is possible to program codes to open any combination of the available doors. 6. Repeat step 5 until the User Code has been assigned to the correct doors. 7. Press the [#] key to edit another User Code's doors and repeat steps 4 & 5. 8. Press [#] twice to exit program mode. 8.3.8

  • IDS LCD Digital Keypad, 18 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 7. To edit other codes repeat steps 3 - 6. 8. Press the [#] key to exit the User Program Mode. 8.3.4 Option 3 - View a User Code Slot Number Hold [*] + [Master Code] + [*] + [3] + [*] + [User Code] + [*] 1. Enter the User Program Mode as per steps 1 - 4 of (8.2). 2. IDS 816 Panel When prompted for the 'Menu Option' press the [3] key followed by the [*] key to select programmable option 3. IDS 1632 & IDS 1224 Panels Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To s

  • IDS LCD Digital Keypad, 11 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 2. As soon as the Entry/Exit zone is violated, the entry delay will begin. The keypad buzzer will sound for the duration of the entry period. The above 2 points only apply if the premises are away armed. 3. Press the [#] key and enter a valid [USER CODE]. If an error beep occurs, press the [#] key and re-enter the user code. 4. Once the system disarms, the ARM indicator will turn off and the keypad buzzer will stop sounding. 5. If no valid user code has been entered prior to the expiry of the entry delay period an alarm condition wil

Related Products and Documents (Keypad):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sony XS-HF55 - Xplod 5 1/4" Speaker Installation/connections manual sony/xs-hf55-xplod-5-1-4-speaker-552.pdf 08 May 2023 14 0.88 Mb
2 Pioneer PDP-S38 Operating instructions manual pioneer/pdp-s38-EM7.pdf 25 Mar 2024 38
3 Farenheit 2 Din Motorized 6.95” Wide Touch-Screen Monitor AM/FM Receiver, DVD Player, USB, SD Card, MP4, iPod Connection Bluetooth Operating manual farenheit/2-din-motorized-6-95-wide-touch-screen-monitor-am-fm-receiver-dvd-player-usb-sd-card-mp4-ipod-connection-bluetooth-8Y6.pdf 13 Aug 2022 55 2.55 Mb
4 Panasonic Toughbook CF-74ECBAXBM Service manual panasonic/toughbook-cf-74ecbaxbm-URL.pdf 28 Jun 2023 50
5 Yaesu FTA-550 series Firmware upgrade manual yaesu/fta-550-series-Y3B.pdf 20 Dec 2023 2
6 Dangerous BAX EQ Operation & user’s manual dangerous/bax-eq-955.pdf 12 Jan 2024 19

Similar Resources:

  • Pyronix

    ATLAS 4

    (28 pages)
    Rins141 Issue 7 INSTALLATION INSTRUCTIONS Led Remote Keypad Pyronix Ltd. October 2001 This Product is approved for use in the Residential, Commercial and Light Industrial Environments ®!8ABCD2134SET567890®INSTALLER DETAILS:TELEPHONE:XXXXXXXXABCDOR …
  • Integra

    KPC-2.8

    (38 pages)
    Axium Keypad Manager OVERVIEWThe Axium Keypad Manager is a Windows program that easily and quickly configures AX-KPC 2.8 touch panels and AX-KPB keypads. Touch Panels are configured using a powerful page designer with predefined and user galleries of images and sounds. A public database of predefined commands as well as a user database is available for stori …
  • Lenze

    E94AZKAE

    (84 pages)
    BetriebsanleitungOperating InstructionsInstructions de mise en serviceInstrucciones para el servicioIstruzioni operativeEDB94AZKAE.&p(Ä.&p(äL−force | 9400 E94AZKAEKeypadKeypadClavier de commandeKeypadTastiera …
  • NAPCO

    Gemini GEM-P1632

    (52 pages)
     � …
  • DMP Electronics

    Thinline 7300 Series

    (28 pages)
    ACBDFEGIHJLKVXWSUTPRQMONYZENTERBACKALL RESET HOMECHIMEZONEPERIM SLEEP EXITINSTTESTOUTPUTCODE1 2 3 45 6 7 89 0CMDINSTALLATION AND PROGRAMMING GUIDE 7300 Series Thinline™ Icon Keypad …
  • Niles

    TS-1

    (50 pages)
    IntelliPad®Ci Touch Screen KeypadB LENDING H IGH F IDELITY AND A RCHITECTURE®INSTALLATION & OPERATION GUIDE102.7 FM100%BandPrev NextMore...TunerDVDDSSCDCLASSICALCOUNTRYEASYHIP HOPJAZZNEWSOLDIESPOPROCKTALKTS-1TS-1 …

Keypad Instructions:

Comments, Questions and Opinions: