IDS LCD Digital Keypad Operation & User’s Manual
|
IDS LCD Digital Keypad, 21 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.3.5.11 Fire Code (Not applicable to the IDS 1224 & IDS 816) If enabled ,this option allows reporting of a Fire Code. In the event that this code is reported, all fire doors will be automatically opened. 8.3.6 Option 5 - Assign User Code to Partitions Hold [*]
IDS LCD Digital Keypad, 8 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 1. Introduction to the IDS LCD Digital Keypad Your installer has selected one of the finest alarm systems available for your installation and has custom programmed the system features to meet your specific requirements. The elegant and user friendly LCD Keypad will allow you easy access to your security system's functions and information at the touch of a button. The 32 character screen will display menus and messages to guide you through the system's operation. Since you will communicate your instructions to your system th
IDS LCD Digital Keypad, 19 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 Table 4 : User Code Properties Zone LED Property 816 1224 1632 1 Master User X X X 2 Duress Code X X X 3 Arm to Disarm Code [Maid‟s Code] X X X 4 Group Arm (Global Arm /Disarm for 816) X X X 5 Group Disarm X X 6 Arm Code X X 7 Disarm Code X X 8 Report User Open Close X X 9 User Phone in Access X X 10 Report User Access X 11 Enable Anti-pass back for User X 12 Fire Code X Explanation of User Code Properties 8.3.5.1
IDS LCD Digital Keypad, 15 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.1 Adding, Deleting and Editing User Codes Hold [*] + [MASTER USER CODE] + [*] + [PROGRAMMABLE OPTION] + [*] All IDS Alarm Panels utilise a user-friendly programmable interface which allows the user to add, modify, or delete user codes. See Table 3 for a summary of programmable options. The programmable interface is accessed by entering the USER PROGRAMMING MODE. Table 3 : User Programming Options Options Summary of Programmable Options 816 1224 1632 Option 0 Allows for the addition of new user codes. x x x Optio
IDS LCD Digital Keypad, 6 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.3.5.11 Fire Code................................................................................................................21 8.3.6 Option 5 – Assign User Code to Partitions.............................................................21 8.3.7 Option 6 – Assign User Code to Doors..................................................................21 8.3.8 Option 7 – Assign User Code to Schedule.............................................................22 8.3.9 Option 8 – Adding User Remotes.......................................................
IDS LCD Digital Keypad, 23 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 8.3.10 Option 9 - Delete User Code (Code known) Hold [*] + [Master Code] + [*] + [9] + [*] + [User Code to be deleted] + [*] 1. Enter the User Program Mode as per steps 1 - 4 of (8.2). 2. IDS 816 Panel When prompted for the 'Menu Option' press the [9] key followed by the [*] key to select programmable option 9. IDS 1632 & IDS 1224 Panels Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To selec
20 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 disarmed, entering a global code at the keypad of the armed partition will disarm that partition and entering a global code at the keypad of the disarmed partition will arm that partition. 8.3.5.5 Group Arm (N
IDS LCD Digital Keypad, 26 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 3. Press the [NUMBER] corresponding to the zone you wish to be programmed as a Buzz zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones. 4. A [Y] next to the zone number indicates that the zone has been programmed as a Buzz zone. Flashing text indicates a Stay zone. A zone cannot be both a Buzz and Stay Zone and a Stay zone cannot be selected as a Buzz zone. 5. Repeat step 3 until all the required buzz zones are programmed. 6. Press the [#] key to exit the buzz programming mode.
17 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 3. The ARM indicator flashes and the LCD prompt reads ' Enter User Code'. 4. Enter the [USER CODE] that you wish to edit. User Names are displayed as the User Slot Number by default. Edit the User Slot Number so that it reads the correct User Name. (See Notes on Editing a User Name). 5. To confirm
IDS LCD Digital Keypad, 16 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 IDS 1632 & IDS 1224 Panels The first menu option - Menu Option 0 - 'Add User' is displayed by default. 6. Select a programmable option from Table 1. In the case of the IDS 1632 and IDS 1224, one may use the [PANIC] or [MED] keys to scroll through the menu options. 7. Confirm the entry by pressing the [*] key. A valid entry is confirmed by a long beep. An invalid entry will be signalled by means of an error beep (3 short beeps). If an error beep occurs, press the [#] key to clear all previous entries, and rep
31 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 Quick Reference User Guide Description Programming Add a User Code [*] [Master Code] [*] [0] [*] [New Code] [*] Change a User Code [*] [Master Code] [*] [2] [*] [Old Code] [*] [New Code] [*] View a Slot Number [*] [Master Code] [*] [3] [*] [User Code] [*] View the Slot number via the zone LED‟s Edit U
IDS LCD Digital Keypad, 25 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 1. Select the required stay profile (See 9.1) 2. Hold down the [3] key until the keypad buzzer sounds. The LCD keypad will indicate that the panel is in Stay mode alongside the partition number. 3. Press the [NUMBER] corresponding to the zone you wish to be a STAY zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones. 4. A [Y] next to a zone number indicates that that particular zone is programmed as a stay zone. NOTE: Buzz zones will be shown by flashing indicators. (See Section 8). A Buzz zone cannot be selec
IDS LCD Digital Keypad, 14 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 IDS 1224 1 - 24 12 IDS 1632 1 - 32 12 For detailed programming instructions, please see the installation manual provided with your Alarm Panel. 1. Press [#] + [INSTALLER CODE] + [*]. If the default installer code is four digits it will be [9999], if it is six digits, it will be [999999]. 2. Enter the [LOCATION] as per table 1 above followed by the [*] key. 3. Enter the [SUB-LOCATION 12] followed by the [*] key. 4. Edit the Zone Name. Notes on Editing a Zone Name Use the [MODE] key to toggl
IDS LCD Digital Keypad, 9 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 If the partition is already STAY armed, this key will initialize AWAY arming. It is therefore possible to change directly from STAY armed to AWAY armed. 2.2 Stay Arming Stay arming allows the user to monitor selected perimeter zones and bypass interior zones. The user can remain on the premises with access to designated areas during the STAY ARM cycle. Any zone whi
IDS LCD Digital Keypad, 13 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 5.3 Medical Alarms [M] (Hold down the [M] key for two seconds until the keypad buzzer sounds) If the [M] key is pressed until the keypad beeps (approximately 2 seconds) a MEDICAL ALARM condition will be activated. The keypad buzzer will beep 5 times. A medical reporting code will be reported to the monitoring company. 5.4 Duress Al
IDS LCD Digital Keypad, 27 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 11.2 How to Cancel Chime Zones HOLD [2] + [ZONE NUMBER] + [*] + [#] 1. Hold down the [2] key until the keypad buzzer sounds. 2. The LCD display will indicate that you are in chime mode. 3. To cancel any chime zones, press the key corresponding to that zone followed by the [*] key. Alternatively use the [PANIC] or [MED] keys to scroll through the zones. 4. An
IDS LCD Digital Keypad, 12 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 4.2 How to Un-Bypass a Zone Hold down [9] + [ZONE NUMBER] + [*] + [#] 1. Enter bypass mode by holding down the [9] key until the keypad buzzer sounds. The power and arm LED's will be off. All zones will be displayed on the screen with either a [Y] or a [N] alongside the zone. 2. [Y] indicates that the zone has been bypassed, whilst [N] indicates that the zone has not been bypassed. 3. Press the number corresponding to the currently bypassed zone, then press th
IDS LCD Digital Keypad, 10 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 The LCD display will read 'Partial Arm' and will indicate any zones which have been bypassed. One is able to scroll through the list of bypassed, as well as violated, zones by using the [PANIC] and [MED] keys. 2.3 How to Stay Arm and Go (Hold down the [6] key for two seconds until the keypad buzzer sounds) This is a single key arm function, which allows the user to STAY arm and leave the premises. If a partition is already stay armed, holding down the [6] key initiates an exit delay,
IDS LCD Digital Keypad, 22 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 Example: If a user is assigned to door 1, there will be a [Y] next to Option 1 and the user can thus open door 1. If the user is assigned to door 14 there will be a [Y] next to Option 14. It is possible to program codes to open any combination of the available doors. 6. Repeat step 5 until the User Code has been assigned to the correct doors. 7. Press the [#] key to edit another User Code's doors and repeat steps 4 & 5. 8. Press [#] twice to exit program mode. 8.3.8
IDS LCD Digital Keypad, 18 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 7. To edit other codes repeat steps 3 - 6. 8. Press the [#] key to exit the User Program Mode. 8.3.4 Option 3 - View a User Code Slot Number Hold [*] + [Master Code] + [*] + [3] + [*] + [User Code] + [*] 1. Enter the User Program Mode as per steps 1 - 4 of (8.2). 2. IDS 816 Panel When prompted for the 'Menu Option' press the [3] key followed by the [*] key to select programmable option 3. IDS 1632 & IDS 1224 Panels Menu option 0 - 'Add User' is displayed on the LCD Screen by default. To s
IDS LCD Digital Keypad, 11 IDS LCD Keypad User Manual 700-292-01C Issued March 2009 2. As soon as the Entry/Exit zone is violated, the entry delay will begin. The keypad buzzer will sound for the duration of the entry period. The above 2 points only apply if the premises are away armed. 3. Press the [#] key and enter a valid [USER CODE]. If an error beep occurs, press the [#] key and re-enter the user code. 4. Once the system disarms, the ARM indicator will turn off and the keypad buzzer will stop sounding. 5. If no valid user code has been entered prior to the expiry of the entry delay period an alarm condition wil
IDS 816 Keypad Installer manual
816 |
Eaton MENVIER30 Keypad Quick user manual
MENVIER30 |
IDS X64 Keypad Installer manual
X64 |
IDS X64 Keypad Operation & user’s manual
X64 |
IDS 805 Keypad Installer manual
805 |
IDS X64 Keypad Installer manual
X64 |
IDS X64 Keypad Operation & user’s manual
X64 |
IDS X16 Keypad Training manual
X16 |
# | Manufacturer | Model | Document Type | File | Updated | Pages | Size |
---|---|---|---|---|---|---|---|
1 | Sony | XS-HF55 - Xplod 5 1/4" Speaker | Installation/connections manual | sony/xs-hf55-xplod-5-1-4-speaker-552.pdf | 08 May 2023 | 14 | 0.88 Mb |
2 | Pioneer | PDP-S38 | Operating instructions manual | pioneer/pdp-s38-EM7.pdf | 25 Mar 2024 | 38 | |
3 | Farenheit | 2 Din Motorized 6.95” Wide Touch-Screen Monitor AM/FM Receiver, DVD Player, USB, SD Card, MP4, iPod Connection Bluetooth | Operating manual | farenheit/2-din-motorized-6-95-wide-touch-screen-monitor-am-fm-receiver-dvd-player-usb-sd-card-mp4-ipod-connection-bluetooth-8Y6.pdf | 13 Aug 2022 | 55 | 2.55 Mb |
4 | Panasonic | Toughbook CF-74ECBAXBM | Service manual | panasonic/toughbook-cf-74ecbaxbm-URL.pdf | 28 Jun 2023 | 50 | |
5 | Yaesu | FTA-550 series | Firmware upgrade manual | yaesu/fta-550-series-Y3B.pdf | 20 Dec 2023 | 2 | |
6 | Dangerous | BAX EQ | Operation & user’s manual | dangerous/bax-eq-955.pdf | 12 Jan 2024 | 19 |
Pyronix
Rins141 Issue 7 INSTALLATION INSTRUCTIONS Led Remote Keypad Pyronix Ltd. October 2001 This Product is approved for use in the Residential, Commercial and Light Industrial Environments ®!8ABCD2134SET567890®INSTALLER DETAILS:TELEPHONE:XXXXXXXXABCDOR
…
ATLAS 4(28 pages) |
Integra
Axium Keypad Manager OVERVIEWThe Axium Keypad Manager is a Windows program that easily and quickly configures AX-KPC 2.8 touch panels and AX-KPB keypads. Touch Panels are configured using a powerful page designer with predefined and user galleries of images and sounds. A public database of predefined commands as well as a user database is available for stori …
KPC-2.8(38 pages) |
Lenze
BetriebsanleitungOperating InstructionsInstructions de mise en serviceInstrucciones para el servicioIstruzioni operativeEDB94AZKAE.&p(Ä.&p(äL−force | 9400 E94AZKAEKeypadKeypadClavier de commandeKeypadTastiera
…
E94AZKAE(84 pages) |
NAPCO
� …
Gemini GEM-P1632(52 pages) |
DMP Electronics
ACBDFEGIHJLKVXWSUTPRQMONYZENTERBACKALL RESET HOMECHIMEZONEPERIM SLEEP EXITINSTTESTOUTPUTCODE1 2 3 45 6 7 89 0CMDINSTALLATION AND PROGRAMMING GUIDE 7300 Series Thinline™ Icon Keypad
…
Thinline 7300 Series(28 pages) |
Niles
IntelliPad®Ci Touch Screen KeypadB LENDING H IGH F IDELITY AND A RCHITECTURE®INSTALLATION & OPERATION GUIDE102.7 FM100%BandPrev NextMore...TunerDVDDSSCDCLASSICALCOUNTRYEASYHIP HOPJAZZNEWSOLDIESPOPROCKTALKTS-1TS-1
…
TS-1(50 pages) |
Clinton Electronics Security Camera CE-VFCD918-WDClinton Electronics CE-VFCD918-WD Manual (Operation & user’s manual), @857C9N CE-VFCD918-WD, 28 |
SMART Interactive whiteboard KAPP42#97N3AK KAPP42: SMART Interactive whiteboard Owner Documentation KAPP42, 48 |
GE Microwave Oven JES1160Microwave Oven PDF Owner's manual JES1160, 60 |
Hamilton Beach Blender 840095900Hamilton Beach 840095900 Manual (Doc Type: Blender Use and care manual) 840095900, 8 |
Hedy Controller HD700 SeriesEasy start manual for Hedy HD700 Series Controller HD700 Series, 40 |
Sony VCR SLV-N70 - Video Cassette RecorderSony SLV-N70 - Video Cassette Recorder Manual (Doc Type: VCR Dimensions) SLV-N70 - Video Cassette Recorder, 1 |
Syris Computer Accessories SYRD245-2UPDF User Guide (@839VT4), Syris SYRD245-2U Computer Accessories (21.11.2023) SYRD245-2U, 8 |
Clarke Work Light CL6FSCL6FS Operating instructions manual - 3D3747 CL6FS, 8 |
Lennox Indoor Fireplace ED4540Lennox ED4540 Guide (Doc Type: Indoor Fireplace Operation & user’s manual) ED4540, 5 |
Zenith Receiver Royal 1000Service manual for Zenith Royal 1000 Receiver Royal 1000, 8 |
IcOtec Hunting Equipment GC300Manual: IcOtec GC300 (L43ZNJ, Upd.Mon 01.2024) GC300, 2 |
Juniper Network Router E SERIES BROADBAND SERVICES ROUTERS - E SERIES END-OF-LIFE MODULE GUIDE 6-10-2010Network Router Manual (Juniper E SERIES BROADBAND SERVICES ROUTERS - E SERIES END-OF-LIFE MODULE GUIDE 6-10-2010) E SERIES BROADBAND SERVICES ROUTERS - E SERIES END-OF-LIFE MODULE GUIDE 6-10-2010, 72 |