Manualios.com

Cardiff Ceiling series Installation Manual

Cardiff Ceiling series Manual Online:

3.2, 2591 votes
Cardiff Ceiling series User Manual
Cardiff Ceiling series User Guide
Cardiff Ceiling series Online Manual

Text of Cardiff Ceiling series User Guide:

  • Cardiff Ceiling series, 5 installation manual 5.2.2 Ceiling Installation Fig.5-10 Hanging arm Remove the side board and the grille.(Refer to Fig. 5-10) (For models 48 and 60, do not remove the grille.) Fig. 5-11 Side board Grille Locate the hanging arm on the hanging screw bolt. (Refer to Fig. 5-12) Prepare the mounting bolts on the unit.( Refer to Fig. 5-13) Screw nut Washer Hanging screw bolt Hanging arm Fig.5-12 20~25mm Fig.5-9 STEEL ROOF BEAM STRUCTRUE Hanging screw bolt Hanging bolts Supporting angle steel Install and use directly the supporting angle steel. Please Refer to Fig.5-3 and Fig.5-4 for the hanging s

  • Cardiff Ceiling series, 8 installation manual 7. INSTALL THE CONNECTING PIPE Check whether the height drop between the indoor unit and outdoor unit, the length of refrigerant pipe, and the number of the bends meet the following requirements: (The number of the bends less than 15) Table 7-1 The length ofefrigerant pipe The max height drop Model 18/24 36/60 72 20 10 25 10 30 15 unit: m Drill a hole in the wall (suitable just for the size of the wall conduit), then set on the fittings such as the wall conduit and its cover. Bind the connecting pipe and the cables together tightly with binding tapes. Pass the bound connecting pipe through

  • Cardiff Ceiling series, 9 installation manual Too large torque will harm the bellmouthing and too small will cause leakage. Please determine the torque according to Table 7-2. After the connecting work is finished, be sure to check that there is no gas leak. Be sure to use both a spanner and torque wrench together when connecting or disconnecting pipes to /from the unit. Fig.7-4 How to expel the air with a vacuum pump Stop valve operation introduction 1. Opening stop valve 2. Closing stop valve 1. 2. 1. 2. 3. Remove the cap and turn the valve count

  • Cardiff Ceiling series, 22 installation manual Fig. 10-18 Air Conditioner Link-circuit (For R22,Cooling& Heating) INDOOR UNIT 2 3 2 3 XT1 XT2 Y&G A B C N 1 1 2 3 OUTDOOR UNIT Y&G XT3 XT4 A B C N 3-core cable 3×2.5mm 2 5-core cable 5×2.5mm 2 5-core cable 5×2.5mm 2 POWER: 380-415V 3N~ 50Hz Model 36-60 (3 PHASE) 4 Fig. 10-19 Air Conditioner Link-circuit (For R22,Cooling only) POWER: 5-core cable 5×2.5mm 2 5-core cable 5×2.5mm 380-415V 3N~ 50Hz 2 INDOOR UNIT OUTDOOR UNIT XT1 A B C N 1 2 3 1-core cable 1×2.5mm= 2 A B C N 1 Model 36-60 (3 PHASE) XT3 XT4

  • 4 installation manual Keep indoor unit, outdoor unit, power supply wiring and transmission wiring at least 1 meter away from televisions and radios. This is to prevent image interference and noise in those electrical appliances. (Noise may be generated depending on the conditions under which the electric wave is generated, even if 1 meter is kept.) 5.2 Install the main body There is enou

  • 21 installation manual Model 36(1 PHASE) Air Conditioner Link-circuit (For R22,Cooling & Heating) N L 1 2 3 XT4 Fig. 10-17 OUTDOOR UNIT L N 1 2 3 INDOOR UNIT XT1 XT2 T3 E XT3 T3 T3 E E Y&G Y&G Y&G POWER: 220-240~ 50Hz 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2 1-core sheild wire 1×0.5mm 2 Fig. 10-16 Mod

  • Cardiff Ceiling series, 13 installation manual Table 10-2 MODEL(For R22,Cooling only) POWER OUTDOOR UNIT POWER WIRING STRONG ELECTRIC SIGNAL INDOOR/OUTDOOR CONNECTING WIRING(mm ) CIRCUIT BREAKER/FUSE (A) 2 INDOOR UNIT POWER WIRING(mm ) PHASE FREQUENCY AND VOLT WEAK ELECTRIC SIGNAL 3x2.5 20/16 40/25 2.5 2.5 GROUND WIRING 1-phase 1-phase 220-240V~ , 50HZ 220-240V~ , 50HZ 3×2.5 3×2.5 1×2.5 3×2.5 2 MODEL(For R22,Cooling& Heating) POWER OUTDOOR UNIT POWER WIRING STRONG ELECTRIC SIGNAL INDOOR/OUTDOOR CONNECTING WIRING(mm ) CIRCUIT BREAKER/FUSE (A) 2 INDOOR UNIT POWER WIRING(mm ) PHASE FREQUENCY AND VOLT WEAK ELECT

  • Cardiff Ceiling series, 20 installation manual 3-core cable 3×2.5 mm 2 1-core sheild wire 1×0.5mm 2 Air Conditioner Link-circuit (For R22,Cooling only) Model 24(1 PHASE) Air Conditioner Link-circuit (For R22,Cooling & Heating) Model 24(1 PHASE) L N 1 2 3 INDOOR UNIT POWER: 220-240~ 50Hz 3-core cable 3×2.5mm 2 1-core cable 1×2.5mm 2 Y/G Y/G OUTDOOR UNIT XT3 L N S Fig. 10-14 Fig. 10-15 OUTDOOR UNIT L N 1 2 3 INDOOR UNIT XT1 XT2 T3 E Y&G Y&G Y&G POWER: 220-240V~ 50Hz 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2

  • Cardiff Ceiling series, 16 installation manual Fig. 10-6 Air Conditioner Link-circuit (For R22,Cooling &Heating) Model 24(1 PHASE) OUTDOOR UNIT L(1) N(1) L N 1 2 3 INDOOR UNIT 1 2 3 4 5 6 XT4 XT1 XT2 T3 E XT3 XT2 T3 T3 E E Y&G Y&G POWER: 220-240~ 50Hz 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2 1-core sheild wire 1×0.5mm 2 Fig. 10-7 Model 24-36(1 PHASE) Air Conditioner Link-circuit (For R22,Cooling only) OUTDOOR UNIT INDOOR UNIT POWER: 220-240~ 50Hz 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2 1-core cable 1×2.5mm 2 1 2 3 4 5 6 XT4 Y&G Y&G L(1) N(1) XT1 L N 1 2 3 XT1

  • Cardiff Ceiling series, 1 installation manual Be sure to be in conformity with the local, national and international laws and regulations. Read "PRECAUTIONS" carefully before installation. The following precautions include important safty items. Observe them and never forget. Keep this manual with the owner's manual in a handy place for future reference. 1. PRECAUTIONS The safty precautions listed here are divided into two categories. In either case, important safty information is listed which must be read carefully. After completing the installation, make sure that the

  • Cardiff Ceiling series, 11 installation manual 10. WIRING The appliance shall be installed in accordance with national wiring regulations. The air conditioner should use separate power supply with rated voltage. The external power supply to the air conditioner should have ground wiring, which is linked to the ground wiring of the indoor and outdoor unit. The wiring work should be done by qualified persons according to circuit drawing. An all-pole disconnection device which has at least 3mm sepaaration distance in all pole and a residual current device (RCD) with the rating of above

  • Cardiff Ceiling series, 2 installation manual To install properly, please read this "installation manual" at first. The air conditioner must be installed by qualified persons. When installing the indoor unit or its tubing, please follow this manual as strictly as possible. If the air conditioner is installed on a metal part of the building, it must be electrically insulated according to the relevant standards to electrical appliances. When all the installation work is finished, please turn on the power only after a thorough check. Regret for no further announcement if there is any change of this manual caused by product improvem

  • Cardiff Ceiling series, 6 installation manual Hang the unit on the hanging arm by sliding backward. Securely tighten the mounting bolts on both sides.(Refer to Fig. 5-13) The dimension of the unit 5.3 Hanging arm Mounting bolt Hanging screw bolt D. Connecting point of refrigerant pipe (D.gas side) Drain point E. Connecting point of refrigerant pipe (E. Liquid side) Fig. 5-14 The figures above are based on model 18 as rated capacity,which may differ from the unit you purchased. Table 5-1 20mm 1670 680 240 1070

  • Cardiff Ceiling series, Ceiling And Floor Type INSTALLATION MANUAL Thank you very much for purchasing our air conditioner, Before using your air conditioner , please read this manual carefully and keep it for future reference.

  • 7 installation manual mm mm Fig.6-2 Fig.6-4 Fig.6-3 H 6.2 Dimension Table 6-1 unit:mm MODEL A B C D E H REMARK F 36 24 852 582 368 390 328 660 340 18 762 530 290 315 270 593 282 895 590 330 350 302 862 313 60 990 624 366 396 340 966 354 Fig.6-2 72 900 590 378 400 330 1167 340 Fig.6-3 6.4 Moving and installation Fig.6-6 All the pictures in this manual are for expla

  • Cardiff Ceiling series, 15 installation manual Fig. 10-4 Air Conditioner Link-circuit(For R22,Cooling& Heating) Model 18(1 PHAS E) OUTDOOR UNIT XT2 T3 E XT1 XT1 XT2 1 N 3 4 5-core cable 5×2.5mm 2 3-core cable 3×2.5mm 2 1-core sheild wire 1×0.5mm 2 POWER: 220-240~ 50Hz INDOOR UNIT Y&G Y&G L N 1 2(N) T3 E 3 4 WHITE(T3) BLACK(E) Fig. 10-5 3-core cable 3×2.5mm 2 3-core cable 3×2.5mm 2 220-240V~ 50Hz Air Conditioner Link-circuit (For R22 ,Cooling Only ) Model 18(1 PHASE) OUTDOOR UNIT INDOOR

  • Cardiff Ceiling series, 19 installation manual Air Conditioner Link-circuit(For R22,Cooling& Heating) Model 18(1 PHASE) 2-core cable 2×0.5mm 2 5-core cable 5×2.5mm 2 Fig. 10-13 Fig. 10-12 Air Conditioner Link-circuit (For R22,Cooling only) POWER: 5-core cable 5×2.5mm 2 5-core cable 5×2.5mm 380-415V 3N~ 50Hz 2 INDOOR UNIT OUTDOOR UNIT XT1 A B C N 1 2 3 XT1 XT2 4 1-core cable 1×2.5mm 2 A B C N 1 Model 72(3 PHASE) XT1 XT2 3-core cable 3×2.5mm 2 POWER: 220-240~ 50Hz INDOOR UNIT Y&G Y&G L N 1 2(N) T3 E 3 4 WHITE(T3) BLACK(E) T I N U R O O D T U O XT1 XT3 5 5V

  • Cardiff Ceiling series, 12 installation manual 2) The outdoor unit a. Whether there is vibration or abnormal noise during operation. b. Whether the generated wind, noise, or condensed of by the air conditioner have influenced your neighborhood. c. Whether any of the refrigerant is leaked. A protection feature prevents the air conditioner from being activated for approximately 3 minutes when it is restarted immediately after shut off. CAUTION 1) The indoor unit a. Whether the switch on the remote controller works well. b. Whether the buttons on the remote c

  • Cardiff Ceiling series, 3 installation manual 3. ATTACHED FITTINGS Please check whether the following fittings are of full scope. If there are some spare fittings , please restore them carefully. Fig.3-1 Never throw or beat the controller. Before installation, operate the remote controller to determine its location in a reception range. Keep the remote controller at least 1m apart from the nearest TV set or stereo equipment. (it is necessary to prevent image disturbances or noise interferences.) Do not install the remote

  • Cardiff Ceiling series, 10 installation manual Additional Refrigerant Charge 7.2 Refrigerant cannot be charged until field wiring has been completed. Refrigerant may only be charged after performing the leak test and the vacuum pumping. When charging a system, care shall be taken that its maximum permissible charge is never exceeded, in view of the danger of liquid hammer. Charging with an unsuitable substance may cause explosions and accidents, so always ensure that the appropriate refrigerant is charged. Refrigerant containers shall be opened slowly. Always use protective gloves and protect your eyes when charging refrigerant. NOTE CAUTION If a negative result is go

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 LG 32LG7000.AEU Owner's manual lg/32lg7000-aeu-C3C.pdf 02 Aug 2022 208
2 Allied Telesis AR2050V Command reference manual allied-telesis/ar2050v-M7L.pdf 06 Oct 2023 2824
3 Philips DTM9030 Operation & user’s manual philips/dtm9030-84S.pdf 21 Feb 2024 30 1.28 Mb
4 Conceptronic CTVDIGUSB2 Specifications conceptronic/ctvdigusb2-867.pdf 10 Apr 2024 3 0.34 Mb
5 Sony PCWA-C150S - Wireless Lan Pc Card Read this first sony/pcwa-c150s-wireless-lan-pc-card-16S.pdf 12 Mar 2023 2 0.02 Mb
6 Cypress Intel 8x930Ax Converting instructions cypress/intel-8x930ax-971.pdf 22 Jun 2023 7 0.3 Mb

Similar Resources:

  • GE

    Carry-Cool AT505

    (8 pages)
    Howtogetthebestfmm.-.\--)-._.-.”useandcareofCarry-Coo~ ModelsAT505,AT506,AT604Enerw-savingtipsp2o~eratingthecontrolsMrdirectionp5Howtocleantheairfilter p5SavetimeandmoneyBeforeyourequestservice,usetheProblemSolver.p6I …
  • Sanyo

    CMH3172A

    (2 pages)
    - Microprocessor Controlled Operation- Wireless Remote Control Operation- Dry Mode- Air Sweep Control- Automatic Fan Operation/3 Fan Speeds- Automatic Heating/Cooling Changeover- Electronic Refrigerant Control Valve- 1 Hour Off Timer- 24 Hour Programmable Clock- Night Set Back Capability- High Power Mode- Quiet Mode- Air Clean Apatite Filter- Negative Ion Ge …
  • Mitsubishi

    Mr.Slim SEZ-KD09

    (36 pages)
    AF_ ELECTRICAir-ConditionersSEZ- KD09, KD12,KD15,KD18NAOPERATION MANUALFor safe and correct use, please read this operation manual thoroughly before operating the air-conditioner unit.MANUEL D'UTILISATIONPour une utilisation correcte sans risques, veuillez life le manuel d'utilisation en entier avant de vous servir duclimatiseur. …
  • Mitsubishi Heavy Industries

    KXZ Series

    (181 pages)
    SERVICE MANUALManual No.'18 • KX-SM-292DATA BOOK(1) Regarding the indoor unit series, refer to the No.'17 • KX-T-266 and '18 • KX-T-281.• Note:VRF INVERTER MULTI-SYSTEM AIR-CONDITIONERS(OUTDOOR UNIT)FDC224KXZME1, 280KXZME1, 335KXZME1KXZ series (Heat pump type)Manual No. '18 • KX-DB-291 …
  • Carrier

    24ACC6 Comfort

    (2 pages)
    24ACC6Comfortt Series Air Conditioner11/2To5NominalTonsWiring Diagrams334024-101 REV. BCONNECTION DIAGRAMCOMPOFMSCRBLUBRNBLKYELBLKYELRED or BLK208/230 1ØPOWERSUPPLYEQUIP GNDL1L2BLUCAPHCFYEL*ST+tBLUYELYEL*SC*CHS*SR(NOTE #8)125*CHBLKBLKorREDBLKBRN(NOTE #9)BLKCONDENSING UNIT CHARGING INSTRUCTIONSFor use with units using R-410A refrigerantINDOOR BLOWER MOTORE …
  • Johnson Controls

    HIFE006B21S

    (28 pages)
    PMGB0375OperationManualINVERTER-DRIVENMULTI-SPLIT SYSTEMHEAT PUMPAIR CONDITIONERSIMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS HEAT PUMP AIR CONDITIONER. KEEP THIS MANUAL FOR FUTURE REFERENCE.Type ModelFloor Exposed(H,Y,C)IFE006B21S(H,Y,C)IFE008B21S(H,Y,C)IFE012B21S(H,Y,C)IFE015B21SFloor Concealed(H,Y,C)IFC006B21S(H,Y,C)IFC008B21S(H,Y,C) …

Comments, Questions and Opinions: