  • 2 2 EN EWF1 Manual v1.2 User manual v1.2 EWF1 compatible with: • ESIM264 v7.11.30 and up + EWT1 16.14 and up. • ESIM364 v02.04.01 and up. • EPIR2 v01.01.02 and up. • EPIR3 all versions. • PITBULL EPIR3 all versions. EWF1CO compatible with: • ESIM364 v02.12.00 and up. • EPIR3 v01.07.00 and up. • PITBULL EPIR3 V02.02.00 and up. Main feature

  • Eldes EWF1, 3 3 EN EWF1 Manual v1.2 2.2. Main Unit & LED Functionality TEST WEEKLY Button for testing the unit / restoring the zone LED EWF1/EWF1CO status indication SIREN Built-in speaker for audio alarm indication RESET Button for restoring default parameters TAMPER Tamper switch SIREN TEST WEEKLY TAMPER LED D O N O T P A I N T FRONT SIDE BACK SIDE RESET BATTERY 1 3. PLACEMENT 1. Place the detector as close to the center of the ceiling as possible. If this is not practical, mount no closer than 10cm (0.33ft) from a wall or corner. Also, if local codes allow, install the detectors on walls, between 10 and 30cm

  • Eldes EWF1, 4 4 EN EWF1 Manual v1.2 3.1. Typical Single-Story House Install a detector on the ceiling or wall inside each bedroom and in the hallway outside each separate sleeping area. If a bedroom area hallway is more than 9m (29.53ft) long, install a detector at each end. If there is a basement: Install a detector on the basement ceiling at the bottom of the stairwell. Bedroom Bedroom Family Room Living Room Kitchen Dining Room Bedroom 3 LEGEND: Minimum required smoke/ CO detector locations. Recommended additional smoke/CO detector locations 3.2. Typical Multi-Story or Split-Level House Install a detector on the ceiling or wall inside each bedroom and in the hallway outside each separate

  • Eldes EWF1, 5 5 EN EWF1 Manual v1.2 3.4. Carbon Monoxide (CO) Poisoning Carbon monoxide is a product of incomplete combustion of organic matter. It is a toxic gas, but, being colorless, odorless, tasteless, and initially non-irritating, it is very dicult for people to detect. CONCENTRATION SYMPTOMS 35 ppm (0.0035%) Headache and dizziness within six to eight hours of constant exposure 100 ppm (0.01%) Slight headache in two to three hours 200 ppm (0.02%) Slight headache within two to three hours; loss of judgment 400 ppm (0.04%) Frontal headache wit

  • Eldes EWF1, 6 6 EN EWF1 Manual v1.2 4. INSTALLATION NOTE: Before installing the wireless device, we highly recommend to refer to RADIO SYSTEM INSTALLATION AND SIGNAL PENETRA- TION manual located at www.eldes.lt/download Wireless device 5 Never install in the following locations: • inside the metal cabinet • closer than 20cm (7.87in) from the metal surface and/or power lines Wireless device EPIR3 0.5 m to 150 m (1.64 to 492.13ft) in open areas 0.5 m to 30 m (1.64 to 98.43ft) inside the building 6 Recommended: •�

  • Eldes EWF1, 7 7 EN EWF1 Manual v1.2 5. MAINTENANCE 5.1. Testing the Unit • The TEST WEEKLY button veries if EWF1/EWF1CO is operational. Firmly push the TEST WEKKLY button and the detector will sound a loud beep. The alarm will stop sounding after releasing the TEST WEEKLY button. When testing EWF1/EWF1CO using ELDES Congu- ration Tool software, the detector will provide short beeps. • The CO self-test on EWF1CO will be carried out by pushing the TEST WEEKLY button at carbon monoxide concentration below 30ppm. The button release will be followed by a built-in siren sound after a 10-second period: • Successful test - 5 beeps each lasting for 100 ms. • Failed test - 1 beep lasting f

  • 8 8 EN EWF1 Manual v1.2 5.4. Cleaning and Precautions During Use Clean the detector at least once a month to remove dust, dirt, or debris. Using the soft brush or wand attachment of a vacuum cleaner, vacuum all sides and cover of the detector. Be sure all the vents are free of debris. If necessary, use a damp cloth to clean the detector cover. Some household substances can aect t

  • Eldes EWF1, 9 9 EN EWF1 Manual v1.2 Copyright © “ELDES UAB”, 2015. All rights reserved It is not allowed to copy and distribute information in this document or pass to a third party without advanced written authori zation by “ELDES UAB”. “ELDES UAB” reserves the right to update or modify this document and/or related products without a warning. Hereby, “ELDES UAB” declares that wireless smoke/CO detector EWF1/EWF1CO is in compliance with the essential requirements and other relevant provisions of Directive 1999/5/EC

More Instructions:

DOWNLOAD
DOWNLOAD
DOWNLOAD

Related Products and Documents (Smoke Alarm):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 DeWalt 36-441B Instruction manual dewalt/36-441b-YMI.pdf 18 Apr 2023 32 2.31 Mb
2 LEGRAND 845 06 Manual  legrand/845-06-E89.pdf 09 Jan 2024 2
3 Magic Chef MCO160S Use and care manual magic-chef/mco160s-K63.pdf 09 Dec 2022 23
4 Intel DQ67OW Product manual intel/dq67ow-733.pdf 29 Jun 2023 84
5 Schlage B-Series Manual  schlage/b-series-711.pdf 11 Dec 2023 16 1.63 Mb
6 Dacor MMD24 Planning manual dacor/mmd24-GMK.pdf 06 Jan 2023 1 0.42 Mb

Similar Resources:

  • Secutron

    MR-2300 series

    (88 pages)
    INSTALLATION &OPERATION MANUAL Revision A Document #: LT-905SECWARNING: This manual contains information on limitationsregarding product use and function and information on thelimitations as to liability of the manufacturer. The entiremanual should be read carefully.M R - 2 3 0 0 S E R I E S LED Fire Alarm Control Panel …
  • ELRO

    RM336

    (78 pages)
    Handleiding 16User’s manual 03 Gebrauchsanweisung 29Mode d’emploi 42Instrukcja obsługi 68Manual de usuario 55Εγχειρίδιο χρήστη 129Návod k použití 117Használati utasítás 93Manualul utilizatorului 105Kullanma kılavuzu 143Korisnički priručnik 81GB HRNL HUDE ROFR CZESPLELTRRM336 …
  • BRK electronic

    SC01NM08

    (7 pages)
    BATTERYSERVICESMOKECOTESTSILENCEMOVE TOFRESH AIRModel SC01NM08-0015-000 Q 09/02IMPORTANT! PLEASE READ CAREFULLY AND SAVE.This user’s manual contains important information about your Smoke/COAlarm’s operation. If you are installing this Smoke/CO Alarm for use byothers, you must leave this manual—or a copy of it—with the end user.TABLE OF CONTENTSInt …
  • Vitek

    VT-SMKC1

    (4 pages)
    blackVITEK• Color CCD Image Sensor with 420 TV Lines (VT-SMKC1) / 550 TV Lines (VT-SMKC1/H)• Minimum Illumination of 0.5 Lux • Camera Mounted On Adjustable Gimbal To Achieve the Perfect Viewing Angle• 3.6mm Standard lens Included (Optional 2.8mm to 25mm Available)• Dimensions: 5.12” (OD) X 2.29” (H)VT-SMKC1 VT-SMKC1/HSide View Color Smoke Detec …
  • Tunstall

    67005/94

    (4 pages)
    User/Installation Instructions for Radio Smoke Detector Model Number: 67005/94 Brief detector presentation - Battery powered radio smoke detector using the scattered light method - Early and reliable fire detection through precise adjustment of the release characteristics - Outstanding operating safety by intelligent analysis of the measuring chamb …
  • Alecto

    SA-100

    (16 pages)
    GEBRUIKSAANWIJZING - NLMODE ÉMPLOI - FGEBRAUCHSANWEISUNG - DMANUAL - EN MODO DE EMPLEO - ESSA-100Rookmelder voor gebruik in huiselijke omgevingDétecteur de fumée pour l’usage dans l’entourage domestiqueRauchmelder für den HeimbereichSmoke detector for domestic use Detector de humo para uso domestico …

Comments, Questions and Opinions: