  • Ads Security FA700KP-ADS, System Overview (Cont'd) 11 Entry/Exit Delays Your system has preset time delays, referred to as exit delay and entry delay. Whenever you arm your system, exit delay gives you time to leave through the designated exit door without setting off an alarm. Exit delay begins immediately after entering any arming command, and applies to all modes of arming protection. If programmed, a slow beeping will sound throughout the exit delay period. Entry delay gives you time to disarm the system when you reenter through the designated entrance door. But the system must be disarmed before the entry delay period ends, or an alarm will occur. The keypad will beep during the entry dela

  • Ads Security FA700KP-ADS, FA700KP-ADS Operating Modes (cont'd) 58 SCREEN ACTION 4. Enter your “Master” code. The "Operating Modes" screen is displayed. 5. Touch the Chime Mode button to turn the Chime Mode on or off. A checkmark appears in the button when the Chime Mode is “ON”. Press the “HOME” or “BACK” button after making your selection. When the FA700KP-ADS exits the “Operating Modes” screen, your selection is saved.

  • Security System Operation (cont'd) 14 SCREEN ACTION Arming (typical) Armed (typical) 2. On the "Arming" screen, press the selected arming button. o The FA700KP-ADS beeps twice (Away and Night Maximum Modes) or 3 times (Stay and Night Instant Modes) o a DISARM button appears o a text message appears stating which zones are arming and whether

  • Ads Security FA700KP-ADS, About the FA700KP-ADS (Cont'd) 9 ITEM FUNCTION Multi- Partitions Check this circle when you want to arm more than one partition. When Multi-Partitions is checked, all partitions within the system can be armed at one time (if the user is so authorized). When the Arm Multi-Partitions circle does not contain a check mark, each partition must be armed individually. MORE CHOICES Press this button for more Security, Lighting, and FA700KP- ADS setup features. UL Listings The FA700KP-ADS has been listed by Underwriters Laboratories for Commercial and Household Fire and

  • 61 Glossary The following terms are used throughout the guide. Arm/Disarm: “Armed” simply means that the burglary portion of your system is turned ON and is in a state of readiness. “Disarmed” means that the burglary system is turned OFF, and must be rearmed to become operational. However, even in a “disarmed” state, “emergency” a

  • Ads Security FA700KP-ADS, Security System Operation (Cont'd) 17 How to Bypass Zones The Bypass function is used when you want to arm your system with one or more zones left open. Bypassed zones are unprotected and will not cause an alarm when violated while your system is armed. • The system will not allow you to bypass fire or emergency zones. • To bypass zones, the system must be disarmed first. To bypass zones do the following: SCREEN ACTION 1. From the "Home" screen, press the SECURITY button. The "Arming" screen is displayed. 2. From the "Arming" screen, press the MORE CHOICES button. The "More Choices" screen is displayed.

  • Ads Security FA700KP-ADS, Security System Operation (cont'd) 20 How to Remove Bypassed Zones A bypassed zone will automatically be unbypassed when you disarm the system. If the system is disarmed and a zone is bypassed, you can remove the bypass as follows: SCREEN ACTION 1. View bypassed zones by pressing the SHOW ZONES button. While the FA700KP-ADS is requesting and receiving the zone data from the control panel, the screen displays "Please Wait!". Then the zones, along with their current status, are displayed. 2. Remove zone bypasses by pressing the CLEAR B

  • Ads Security FA700KP-ADS, 42 Voice Messages Introduction to Recording and Retrieving Messages The FA700KP-ADS provides the capability of recording voices messages for others on the premises. The number of messages is not limited however; the total time of all messages added together cannot exceed 127 seconds. Note: The voice messages are stored in the memory of the FA700KP- ADS. All messages will be lost if the unit loses power or if it is reset. Voice messages are recorded and retrieved using the “Messag

  • Ads Security FA700KP-ADS, ÊK0976-6fŠ K0976-6 1/05 ONE YEAR LIMITED WARRANTY Honeywell International Inc., acting through its First Alert Professional Security Systems business ("Seller"), 165 Eileen Way, Syosset, New York 11791, warrants its security equipment (the "product") to be free from defects in materials and workmanship for one year from date of original purchase, under normal use and service. Seller's obligation is limited to repairing or replacing, at its option, free of charge for parts, labor, or transporta- tion, any product proven to be defective in materials

  • Ads Security FA700KP-ADS, Maintaining Your System (cont'd) 60 SCREEN ACTION 4. Press the CLEAN SCREEN button. A pop-up window displaying “Touch Screen will be disabled so that you may wipe the screen clean. Please use a damp, soft cloth. DO NOT use any liquids, sprays, or ammonia-based cleansers. Press CONTINUE to disable touchscreen. When the Continue button is pressed the “Touch Screen Disabled for => 30 Seconds” message is displayed. During these 30 seconds the touch screen should be wiped clean of fingerprints using a mild soap solution and a soft cloth. When the counter reaches zero, the window automatically closes and the touch screen is active. Note: Do not spr

  • Ads Security FA700KP-ADS, Security System Operation (Cont'd) 21 SCREEN ACTION 3. The "User Authorization" screen is displayed with the instructions To Clear Bypasses, Enter Code. Note: A zone cannot be unbypassed while the system is armed. Enter your 4-digit user code. The "More Choices" screen is displayed showing the system as Ready to Arm. Note: This will not occur if any zone(s) is open (not ready).

  • 10 System Overview Introduction to Your System This system offers you burglary protection and may offer fire and emergency protection. Monitoring is accomplished with various contact and motion sensors for perimeter and interior burglary protection, plus the system may have strategically placed smoke, heat, or combustion detectors. Burglary Protection

  • Ads Security FA700KP-ADS, Security System Operation (cont'd) 22 How to Disarm the System IMPORTANT: If you return and the main burglary sounder is on, DO NOT enter the premises, but call the police from a nearby safe location. If you return after an alarm has occurred and the main sounder has shut itself off, the FA700KP-ADS will beep rapidly upon entering, indicating that an alarm has occurred during your absence. LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location. Disarm the system as follows: SCREEN ACTION 1. P

  • Ads Security FA700KP-ADS, FA700KP-ADS Setup (cont'd) 54 How to Set the Time and Date You can set the time and date from the Set Time & Date screen. Pressing the Time and Date bar located at the bottom of each FA700KP-ADS screen displays the Set Time & Date screen. • When the time is set it will be stored in the FA700KP-ADS only. The FA700KP-ADS will send the time to the control panel every hour. This 1-hour timer starts on FA700KP-ADS power-up. • If Adjust for DST (Daylight Savings Time) is selected, the FA700KP-ADS will adjust for Daylight Savings time. When selecte

  • Ads Security FA700KP-ADS, Voice Messages (Cont'd) 44 SCREEN ACTION 2. Select the message you wish to listen to by touching it in the message list and then pressing the Play Message button. As the message is being played, a “Play (x): Voice Message…” message is displayed above the message list window. When the end of the message is reached, the playback will stop. 3. To listen to the next message, press the Advance One Message and Play button. 4. If you wish to delete messages, press the Delete button. The “Delete Memo” screen will be displayed. You can press the Del Selected button to d

  • About the FA700KP-ADS (cont'd) 8 FA700KP-ADS "Arming" Screen From the "Home" screen, press SECURITY to access the FA700KP- ADS "Arming" screen. Use this picture and the table that follows to become familiar with the FA700KP-ADS security functions. ITEM FUNCTION AWAY Press this button to arm when no one will be stayi

  • Ads Security FA700KP-ADS, FA700KP-ADS Setup (Cont'd) 51 How to Adjust the Volume You may adjust the FA700KP-ADS speaker volume by pressing your finger on the TouchCenter slide bar associated with the "Volume" scale and doing the following: If… Then… you want to increase volume move the slide bar above the current volume setting. you want to decrease volume move the slide bar below the current volume setting. VOLUME SLIDE BAR INDICATOR 6270-007-V1 FA700KP-ADS Volume Control

  • Ads Security FA700KP-ADS, 31 User Code Setup Introduction to User Code Setup Each user must be assigned a name with a corresponding 4-digit user code in order to gain access to various features and functions. Users for the system are programmed in a central user setup location that provides the specific questions for authorization levels assigned to different users. You may want these users to be the same, but there are situations in which you may want a user to have limited capabilities. How to Access User Setup Access User Setup as follows: SCREEN ACTION 1. From the "Home" screen, press the SECURITY button. The "Arming" screen is di

  • Ads Security FA700KP-ADS, User Code Setup (Cont'd) 35 SCREEN ACTION 8. Touch the box below the User Number. The "User Number" screen is displayed with the instructions to Enter 2 Digits or Enter 3 Digits dependent upon the system you have. 9. Enter the 2 or 3-digit user number for this user. The “User Options” screen is displayed with the user’s name, number, and code displayed. 10. If this user is assigned an RF button zone, touch the box below the RF Button Zone. The "RF Button Zone " screen is displayed with the instructions to enter 2

  • Ads Security FA700KP-ADS, 13 Security System Operation Introduction to Security System Operation You can arm your system in one of three arming modes: Away, Stay, and Night. The following table lists the three different arming modes and the results of each. FEATURES FOR EACH ARMING MODE Arming Mode Exit Delay Entry Delay Perimeter Armed Interior Armed Away Yes Yes Yes Yes Stay Yes Yes Yes No Night* Yes Yes (set for Away or Stay Mode) No (set for Instant or Maximum Mode) Yes Yes (set for Away Mode) No (set for Stay, Instant or Maximum Mode) *Your installer may have configured Night Mode differentl

  • Ads Security FA700KP-ADS, 48 FA700KP-ADS Setup How to Access FA700KP-ADS Setup Options Setup allows you to adjust the TouchCenter contrast and/or adjust the FA700KP-ADS speaker volume. You may also select the time interval that must pass prior to the FA700KP-ADS going into screen saver mode (screen goes blank). Additionally, you may enter the User Setup screen, Advanced Setup screen (if enabled by your system installer), or Clean Screen (maintenance mode) from the "Setup" screen by pressing the corresponding button. The “Advanced Setup” button will only be active

  • Ads Security FA700KP-ADS, FA700KP-ADS Setup (Cont'd) 53 SCREEN ACTION 3. Press either the "Home" or "Back" button. A Settings Changed! pop-up window is displayed asking “Settings Changed! Remember New Settings?“ Select Yes to save the change or No to discard the change. When the Update is complete the FA700KP-ADS goes to the "Home" screen or "More Choices" screen depending on whether you pressed the "Home" or "Back" button, respectively ("Home" screen shown).

  • Ads Security FA700KP-ADS, Conventions Used in This Manual Before you begin using this manual, it is important that you understand the meaning of the following symbols (icons) and text note. U L These notes include specific information that must be followed if you are installing this system for a UL Listed application. This symbol indicates a critical note that could seriously affect the operation of the system, or could cause damage to the system. Please read each warning carefully. This symbol also alerts the user to the possibility of physical harm if instructions are not followed

  • Ads Security FA700KP-ADS, Table of Contents 3 ABOUT THE FA700KP-ADS ............................................................................... 5 Introduction.................................................................................................... 5 The FA700KP-ADS Interface......................................................................... 5 Navigating through the FA700KP-ADS.......................................................... 6 About Your Home Screen.............................................................................. 6 FA700KP-

  • Ads Security FA700KP-ADS, 40 Advanced System Features Introduction to Advanced System Features While most of the commonly used security functions are available from the FA700KP-ADS’s advanced user interface, there are some less used, advanced features that can either be accessed through Console Emulation mode on the FA700KP-ADS or a standard alpha keypad. To use features not supported by the FA700KP-ADS, refer to your Control Panel User Guide. Console Emulation Mode Console Mode allows you to use a FA700KP-ADS interface j

  • Ads Security FA700KP-ADS, FA700KP-ADS Setup (cont'd) 50 How to Adjust the TouchCenter Contrast You may adjust the TouchCenter contrast as follows: If… Then… you want to increase contrast move the slide bar above the current contrast setting. you want to decrease contrast move the slide bar below the current contrast setting. another adjustment or selection is to be made go to the corresponding paragraph in this section. no additional adjustment or selection is to be made press the "Back" button below the screen to return to the previous screen, or press the "Home" button below the screen to return to your "Home" screen. C

  • 57 FA700KP-ADS Operating Modes Operating Modes Operating modes allows you to turn the FA700KP-ADS chime mode on or off. When the chime mode is selected, a request is sent to the alarm panel requesting that the panel chime the FA700KP-ADS whenever a change in zone status occurs. How to Access Operating Modes Access the "Operating Modes" feature as follow

  • Ads Security FA700KP-ADS, Table of Contents (Cont'd) 4 How to Access User Setup.......................................................................... 31 How to Add a User ...................................................................................... 33 How to Delete a User .................................................................................. 37 How to Edit a User....................................................................................... 38 ADVANCED SYSTEM FEATURES ................................................................... 40

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 BIO RAD Trans-Blot SD Instruction manual bio-rad/trans-blot-sd-PC2.pdf 06 Apr 2023 19
2 Lumel P30U series Operation & user’s manual lumel/p30u-series-AP5.pdf 09 Oct 2023 132
3 Bell and Howell Truper 3600 Operator's manual bell-and-howell/truper-3600-268.pdf 18 Jun 2023 142 13.91 Mb
4 Aeris ATMOS 2 Operating manual aeris/atmos-2-233.pdf 10 Jul 2023 96
5 Liebert HPC-S 006 Product documentation liebert/hpc-s-006-R33.pdf 25 Jun 2023 52
6 Samsung SPHM620 Manual  samsung/sphm620-2M3.pdf 18 Aug 2022 340

Similar Resources:

  • Honeywell

    VISTA-32FBPT

    (80 pages)
    800-11045 2/12 Rev. C VISTA-32FBPT Commercial Fire and BurglaryCommercial Fire and BurglaryCommercial Fire and BurglaryCommercial Fire and Burglary Partitioned Security SystemsPartitioned Security SystemsPartitioned Security SystemsPartitioned Security Systems with Schedulingwith Schedulingwith Schedulingwith Scheduling User G …
  • Cisco

    500 Series

    (60 pages)
    Cisco Headset 500 Series User GuideFirst Published: 2019-01-23Last Modified: 2020-06-18Americas HeadquartersCisco Systems, Inc.170 West Tasman DriveSan Jose, CA 95134-1706USAhttp://www.cisco.comTel: 408 526-4000800 553-NETS (6387)Fax: 408 527-0883 …
  • NAPCO

    GEM-EZM4/8

    (4 pages)
    1 ADDENDUM GEM-EZM4/8 ZONE EXPANSION MODULE for the GEM-P1664 Control Panel R333 Bayview Avenue Amityville, New York 11701 For Sales and Repairs, (800) 645-9445 For Technical Service, (800) 645-9440 Publicly traded on NASDAQ Symbol: NSSC © NAPCO 2005 WI1418A 5/05 DESCRIPTION The capacity of the GEM-P1664 control panel may be expanded through …
  • Moog

    Covert

    (2 pages)
    wCovert Surveillance System Law Enforcement AidThe Covert Surveillance Camera System offered by Moog provides a versatile self contained network and PTZ camera system in a covert, weather proof, portable, NEMA enclosure. The Covert Surveillance System is the ideal solution when the situation / environment calls for a hidden, exible, rapid deployment sy …
  • Viking

    E-1600-02A

    (12 pages)
    The 1600A Series ADA Compliant EmergencyPhones are designed to provide quick and reliablehandsfree communication for any standard analogtelephone line or analog phone system station port. All1600A Series phones meet ADA requirementsfor elevator/ emergency telephones, and canbe programmed from any Touch Tone phone.The phones can dial up to 5 programmableeme …
  • Sanyo

    VA-84SA

    (3 pages)
    INSTRUCTION MANUALVA-84SPower Board Unit (for AC 24 V)Unité de carte d’alimentation (pour CA 24 V)Placa de alimentación (para CA 24 V)Stromversorgungsmodul (für AC 24 V)电源板装置 (用于AC 24 V)EnglishFrançaisEspañolDeutsch中文简体About this manualBefore installing and using this unit, please read this manual carefully. Be sure to keep it ha …

Comments, Questions and Opinions: