  • 8 .EVERUSEANELECTRICALADAPTORWITHTHISGROUNDEDPLUG Replace a damage or worn cord immediately. Replace a damaged or worn cord immediately. SPEED AND WIRING The no-load speed of the electric motor varies by model and specification. The motor speed is not constant and decreases under a load or with lower voltage. For voltage, the wiring in

  • Central Pneumatic 67696, 9 0RESSURE3WITCH !UTOMATICALLYCONTROLSTHEONOFFCYCLINGOFTHECOMPRES SOR)TSTOPSTHECOMPRESSORWHENTHECUTOFFPRESSUREIN THETANKISREACHEDANDSTARTSTHECOMPRESSORWHENTHE AIRPRESSUREDROPSBELOWTHECUTINPRESSURE 03)0OUNDS0ER3QUARE)NCH -EASUREMENTOFTHEPRESSUREEXERTEDBYTHEFORCEOFTHE AIR4HEACTUALPSIISMEASUREDBYAPRESSUREGAUGEONTHE COMPRESSOR 0UMP 0RODUCESTHECOMPRESSEDAIRWITHARECIPROCATINGPISTON CONTAINEDWITHINTHECYLINDER 2

  • Central Pneumatic 67696, 15 WARNING: If air leaks after the ring has been released, or if the valve is stuck and cannot be actuated by the ring, Do Not use the air compressor until the safety valve has been replaced. Use of the air compressor in this condition could result in serious personal injury. DRAINING THE TANK See Figures 10 - 11. To help prevent tank corrosion and keep moisture out of the air used, the tank of the compressor should be drained daily. A correct use of the drain valve: Verify that the compressor is turned off. Holding the handle, tilt the compressor toward the drain valve so that it’s set in a lower position. Open the drain

  • Central Pneumatic 67696, 11 FEATURES ASSEMBLY KNOW YOUR AIR COMPRESSOR See Figure 2. Before attempting to use this product, familiarize yourself with all operating features and safety rules. DESCRIPTION Your air compressor is aircooled, oil lubricated, belt-driven, single stage. PRESSURE REGULATOR KNOB Use the pressure regulator knob to adjust the amount of air being delivered through the hose. REGULATOR PRESSURE GAUGE The current line pressure is displayed on the regulator pressure gauge. This pressure can be adjusted by rotating the pressure regulator knob. SAFETY VALVE The safety valve is designed to automatically release air if the air receiver pressure exceeds the

  • Central Pneumatic 67696, 14 APPLICATIONS Air compressors are utilized in a variety of air system applications. Match hoses, connectors, air tools, and accessories to the capabilities of the air compressor. You may use this tool for purposes listed below: Operating some air-powered tools. Inflating tires, air beds, sports equipment, etc. USING THE AIR COMPRESSOR See Figures 6 - 8. Ensure tank drain is closed. Ensure lever of the pressure switch is in the ‘OFF’ position and air compressor is unplugged. Connect the air line to the quick coupler. WARNING: Always wear safety goggles or safet

  • Central Pneumatic 67696, 2 This unit was fully tested and inspected prior to shipment and will operate properly when instructions are followed. Refer to your owner’s manual for basic troubleshooting. To avoid unnecessary return to the store, simply call Compressor Support toll free for additional assistance. DO NOT RETURN TO STORE IMPORTANT STOP STOP Compressor Support: 1-800-444-3353  • Air Compressor will automatically shut off when maximum PSI is reached. When the tank pressure drops to the cut in pressure (low pressure) and the on/off swit

  • Central Pneumatic 67696, 20 TROUBLESHOOTING Problem Possible Cause Solution Air leak from the valve of the pressure switch Check valve does not perform its function correctly due to wear or dirt on the seal Unscrew the hex-shaped head of the check valve, clean the housing and the special rubber disk (replace if worn). Re-assembler and tighten carefully Condensate drainage cock open Close the condensate drainage cock Rilsan hose not inserted correctly in pressure switch Insert the Rilsan hose correctly inside the pressure switch Reduction of efficiency, frequent start- up. Low pressure values Excessively high consumption Decrease the demand of compressed ai

  • Central Pneumatic 67696, 5  Know your power tool. Read operator’s manual carefully. Learn its applications and limitations, as well as the specific potential hazards related to this tool. Following this rule will reduce the risk of electric shock, fire, or serious injury.  Drain tank of moisture after each day’s use. If unit will not be used for a while, it is best to leave drain valve open until such time as it is to be used. This will allow moisture to completely drain out and help prevent corrosion on the inside of tank.  Risk of Fire or Explosion. Do not spray flammable liq- uid in a confined area. Spray area must be well ventilat- ed. Do not smoke while s

  • Central Pneumatic 67696, 4 Never point any tool toward yourself or others. Keep the exterior of the air compressor dry, clean, and free from oil and grease. Always use a clean cloth when cleaning. Never use brake fluids, gasoline, petroleum-based products, or any strong solvents to clean the unit. Following this rule will reduce the risk of deterioration of the enclosure plastic. SERVICE Tool service must be performed only by qualified repair personnel. Service or maintenance performed by unqualified personnel may result in a risk of injury. GENERAL SAFETY RULES Disconnect power supply, open drain valve to dec

  • Central Pneumatic 67696, 7 7=1&307 7)6:-') 7IVZMGMRKVIUYMVIWI\XVIQIGEVIERHORS[PIHKIERH WLSYPHFITIVJSVQIHSRP]F]EUYEPMJMIHWIVZMGIXIGL RMGMER*SVWIVZMGI[IWYKKIWX]SYVIXYVRXLITVSHYGXXS XLIRIEVIWX%98,36->)(7)6:-')')28)6JSVVITEMV ;LIRWIVZMGMRKYWISRP]MHIRXMGEPVITPEGIQIRXTEVXW ;%62-2+ 8SEZSMHWIVMSYWTIVWSREPMRNYV]HSRSXEXXIQTXXSYWI XLMWTVSHYGX�

  • Central Pneumatic 67696, SIX GALLON OILLESS AIR COMPRESSOR Model 67696 SET UP AND OPERATING INSTRUCTIONS Visit our website at: http://www.harborfreight.com Read this material before using this product. Failure to do so can result in serious injury. SAVE THIS MANUAL. For technical questions or replacement parts, please call 1-800-444-3353. 68066 Model 67696 68127 29 GALLON BELT DRIVEN AIR COMPRESSOR

  • Central Pneumatic 67696, 16 WARNING: When servicing, use only identical Harbor Freight Tools replacement parts. Use of any other parts may create a hazard or cause product damage. WARNING: Always wear safety goggles or safety glasses with side shields during power tool operation or when blowing dust. If operation is dusty, also wear a dust mask. WARNING: Always release all pressure, disconnect from power supply, and allow unit to cool to the touch before cleaning or making repairs on the air compressor. MAINTENANCE GENERAL MAINTENANCE Humidity in the air causes condensate

  • Central Pneumatic 67696, 19 TROUBLESHOOTING Problem Possible Cause Solution Compressor will not run Loss of power or overheating No electrical power Blown shop/house fuse Shop/house breaker open Thermal overload open Pressure switch bad Tank is full of air Check for proper use of extension cord Check to be sure unit is plugged in Check fuse/breaker or motor over- load Replace shop/house blown fuse Reset shop/house breaker, determin- ing why problem happened Motor will restart when cool Replace pressure switch Compressor will turn on when tank pressure drops to cut-in pressure Motor hums but cannot run or runs slowly Low voltage Wrong gauge wire or length of exten- sion cord Shorted or open motor winding Defec

  • Central Pneumatic 67696, 10 FEATURES Fig. 2 TANK PRESSURE GAUGE ELECTRICAL CABLE ELECTRIC MOTOR TANK QUICK COUPLER CHECK VALVE REGULATOR PRESSURE GAUGE SAFETY VALVE PRESSURE SWITCH (ON/OFF) PRESSURE REGULATOR KNOB PRODUCT SPECIFICATIONS Running Horsepower ................................................... 2 HP Air Tank Capacity ...................................................... 29 gal. Air Pressure ....................................................150 PSI max. Air Delivery ......................................... 7.3 SCFM

  • Central Pneumatic 67696, 12 ASSEMBLY ASSEMBLING THE RUBBER FOOT AND WHEELS See Figure 3. Mount the rubber feet as shown in figure. Tighten firmly with an open-end wrench (not included) to secure it in position. Mount the wheels as shown in figure. Tighten firmly with an open-end wrench (not included) to secure the wheels in position. Fig. 3 WHEEL SCREW NUT NUT WASHER WASHER SCREW RUBBER FOOT WASHER WASHER(s) NUT ASSEMBLING THE HANDLE See Figures 4 - 5. Lower the handle onto the compressor body, as shown in Figure 4. Line the holes of the handle with the ones on the slots of the compressor. Then insert the two knobs an

  • Central Pneumatic 67696, 13 ASSEMBLY BREAKING IN THE PUMP See Figures 6 - 9. Check and tighten all bolts, fittings, etc. Turn the pressure regulator knob fully clockwise to open the air flow. Place the lever of the pressure switch in ‘OFF’ position and plug in the power cord. Open the drain valve completely. Place the lever of the pressure switch in ‘AUTO’ position and run the air compressor for 10 minutes to break in pump parts. Place the lever of the pressure switch in ‘OFF’ position. Close the drain valve. Fig. 6 LEVER IN ‘OFF’ POSITION Fig. 7 Fig. 9 TANK PRESSURE GAUGE QUICK COUPLER REGULATOR PRESSURE GAUGE SAFETY VALVE PRESSURE SWITCH (ON/OFF) DRAIN VALVE PRESSURE

  • Central Pneumatic 67696, 3 +)2)6%07%*)8=690)7 ;%62-2+ 6IEHERHYRHIVWXERHEPPMRWXVYGXMSRW*EMPYVIXSJSP PS[EPPMRWXVYGXMSRWPMWXIHFIPS[QE]VIWYPXMRIPIGXVMG WLSGOJMVIERHSVWIVMSYWTIVWSREPMRNYV] 7%:)8,)7)-27869'8-327 ;36/%6)% /IIT]SYV[SVOEVIEGPIERERH[IPPPMX'PYXXIVIH FIRGLIWERHHEVOEVIEWMRZMXIEGGMHIRXW*PSSVQYWX RSXFIWPMTTIV]JVSQ[E\SVHYWX (SRSXSTIVEXITS[IVXSSPWMRI\TPSWMZIEXQS WTLIVIWWYGLEWMRXLITVIWIRGISJJPEQQEFPIPMU YMHWKEWI

  • LIMITED 1 YEAR / 90 DAY WARRANTY Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and durability standards, and warrants to the original purchaser that for a period of one year from date of purchase that the tank is free of defects in materials and workmanship (90 days if used by a professional contractor or if used as rental equipment). Harbor

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sonnet Tempo SATA Pro 6Gb PCIe 2.0 Quick start manual sonnet/tempo-sata-pro-6gb-pcie-2-0-I13.pdf 19 Jul 2022 2 0.5 Mb
2 Dell 6000 Service manual dell/6000-A97.pdf 04 Jan 2023 45 1.5 Mb
3 Yamaha SXV70MK Owner's manual yamaha/sxv70mk-318.pdf 14 Feb 2023 88 6.61 Mb
4 Mediacom SPORTSCAM Operation & user’s manual mediacom/sportscam-6AU.pdf 09 Nov 2022 24
5 Toshiba TDP-S35U Specifications toshiba/tdp-s35u-UUL.pdf 02 Apr 2023 2 0.08 Mb
6 PRESONUS FIREPOD - WINDOWS XP How to use presonus/firepod-windows-xp-JD3.pdf 03 Dec 2023 1

Similar Resources:

  • Campbell Hausfeld

    Air Compressor

    (8 pages)
    Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.Protect yourself and others by observing all safety information. Failure to ¢omp_ with instructions could result in personal injury and/or prop.erty damage/Retain instructions for future reference.AirCompressorsDescriptio …
  • Meec tools

    200-073

    (25 pages)
    Bruksanvisning för kompressor Bruksanvisning for kompressor Instrukcja obsługi kompresora Operating Instructions for Compressor 200-073 SV Bruksanvisning i original NO Bruksanvisning i original PL Instrukcja obsługi w oryginale EN Operating instructions in original 08.06.2015 © Jula AB …
  • Michelin

    MVX50

    (48 pages)
    MVX 50ITMANUALE D’USO E MANUTENZIONEENINSTRUCTION MANUAL AND SAFETY INSTRUCTIONFRMANUEL D’UTILISATION ET CONSIGNES DE SÉCURITÉDEBEDIENUNGS-UND WARTUNGSHANDBUCHESMANUAL DE USO Y MANTENIMIENTOPTMANUAL DE USO E MANUTENÇAONLHANDLEIDINGDKBRUGERMANUALSEHANDLEIDINGFIKÄYTTÖOPAS …
  • Titan

    TAC-2T

    (16 pages)
    1P.O. Box 791 • Traveler s Rest, SC 29690 • Phone: (864) 834-7212 • Fax: (864) 834-5 127Ser vice/Replacement Par t s: (80 0) 8 45 -4141 • www.titanindustrial.netOWNER’S MANUALMODEL TAC-2TCommercial Dual Tank CompressorThe Emission Control System for this generator is warranted for standards set by the Environment Protection Agency.IMPORTANT!It is e …
  • DeWalt

    DXCMLA1682066

    (28 pages)
    DXCMLA1682066Single Stage, Belt Drive, Electric Air CompressorsCompresseurs d’air électriques à un étage à entraînement par courroieCompresores eléctricos de aire, de una sola etapa y accionamiento por correaINSTRUCTION MANUALGUIDE D'UTILISATIONMANUAL DE INSTRUCCIONESINSTRUCTIVO DE OPERACIÓN, CENTROS DE SERVICIO Y PÓLIZA DE GARANTÍA. ADVER …
  • Corken

    D791

    (52 pages)
    Model T891CompressorModel D891 Compressor PackageIJ110EInstallation, Operation & Maintenance ManualD and T-Style Double-Acting Gas CompressorsModels D791, T791, D891 and T891Warning: (1) Periodic inspection and maintenance of Corken products is essential. (2) Inspection, maintenance and installation of Corken products must be made only by experienced, …

Comments, Questions and Opinions: