Manualios.com

INFOSEC UPS SYSTEM E6 LCD-RT Operation & User’s Manual

INFOSEC UPS SYSTEM E6 LCD-RT Manual Online:

3.25, 1666 votes
INFOSEC UPS SYSTEM E6 LCD-RT User Manual
INFOSEC UPS SYSTEM E6 LCD-RT User Guide
INFOSEC UPS SYSTEM E6 LCD-RT Online Manual

Text of INFOSEC UPS SYSTEM E6 LCD-RT User Guide:

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 1 Table of Contents 1.Important Safety Instruction......................................................... 2 1.1 An Important Notice............................................................................2 1.2 Storage Instruction.............................................................................3 2.Product Introduction...................................................................... 4 2.1 General Characteristics................

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 2 1. Important Safety Instruction 1.1 An Important Notice  For Parallel System installation, please refer to “E6 LCD RT 5-10 KVA Parallel System Installation Guide”  Because of “LITTLE LEAKAGE CURRENTS” generated by the EMI filter of the UPS, it is necessary to double ensure if the earth of the UPS is properly grounded before AC Mains is connected with.  Th

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 3  The UPS offers CVCF (Constant Voltage Constant Frequency) setting function. a. For correct setting and wiring, please contact with your local agent. b. Do not do it by yourself; otherwise, your warranty will be void.  This UPS has been designed and constructed to protect your assets from the

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 4 2. Product Introduction 2.1 General Characteristics  True online architecture continuously supplies in your critical device with a stable, regulated, transient-free pure sine wave AC Power.  20KHz PWM sine-wave topology yields an excellent overall performance. The high crest factor of the inverter handles all high-inrush current loads without a need to upgrade the power rating.  Multi-functional LCD/LED panel may disp

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 5  When UPS is in trouble, you may read out the possible fault reason from the LCD screen directly, which may reduce down unnecessary repair task a lot.  When the UPS is operated under CF50 or CF60 mode, the recommended load connected shall be 75% of rated capacity if the input voltage is 176~280Vac and 50% of the r

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 6 21 Bypass Input Normal LED 22 UPS under Redundancy Mode 23 UPS under ECO Mode 24 UPS Fault or Abnormal Warning LED 25 EPO Emergency Power Off 26 Er05 Battery Weak or Dead 27 Er06 Output Short Circuit 28 Er10 Inverter Over-current 29 Er11 UPS Overheat 30 Er12 UPS Output Overloading 31 Er14 Fan error 32 Er15 Wrong Procedure to enter Maintenance Mode 33 Er16 Output Parameters Set Error in Parallel System 34 Er17 ID Numbers are in co

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 7 2.3 Panel explanation 2.3.1 Front Panel Function Explanations LCD Display Green LED lights up to indicate the UPS has the capability to run under redundancy mode. Green LED steadily lights up to indicate that the Utility input voltage is within the window; the LED flashes flickeringly to indicate that the Utility input voltage is within the acceptable window. Green LED lights

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 8 2.3.2 Rear Panel Explanation

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 9 A RS232 Port B Terminal Resistor for Parallel function C CAN Bus Connection Port for Parallel System D Customer Options Slot 1 E Customer Options Slot 2 F Cooling Fan G External Battery Connector H Utility Input Breaker CB1 I Bypass Input Breaker CB2 (for Dual Input Model Only) J Input/Output Terminal Block K EPO(Emergency Power Off�

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 10 3. Installation and Operation The packing condition and the external outlook of the unit should be inspected carefully before installation. Retain the packing material for future use. 3.1 Unpacking  Take the UPS out of the PE foam.  Unwrap the UPS.  Standard Package includes:  1 set of Quick Start Manual  1

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 11 3.2 Selecting Installation Position It is necessary to select a proper environment to install the unit, in order to minimize the possibility of damage to the UPS and extend the life of the UPS. Please follow the advice below: 1. Keep at least 30cm (12 inches) clearance from the rear panel of the UPS to the wall. 2. Do not block the air-flow to the ventilation openings of the unit. 3. Please check the installat

  • INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 12 3.4 Terminal Block Explanation & UPS connection 3.4.1 Terminal block ● L12-N1; R-S-T-N1: the terminal for Utility I

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 13 3.4.2 UPS Connection 1. See the following chart for input and output cable section & breaker calibration Note: Do not use the wall receptacle as the input power source for the UPS, as its rated current is less than the UPS’s maximum input current. The receptacle may be b

  • INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 14  External battery bank E6 LCD 5000 RT: The batteries are fitted inside UPS bank. For all other UPS from 6000 to 10kVA, the batteries are fitted inside an ex

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 15 3.5 Operation Test and Installation Instruction 3.5.1 Start Up in Normal Mode 1. Open the terminal block cover on the rear panel (refer to 0). Before start the installation, please make sure the grounding is connected properly. 2. Make sure Utility breaker, UPS’ Utility breaker and B

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 16 E2 * It shows “Fail” in self-test F * It shows “220Vac” in Utility Input. 8. In case of failure in self-test, the LCD display will illustrate from Drawing D to drawing E2, then an error code or error status will be shown on the screen. 9. Your start-up operation of the UPS

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 17 3.5.3 Check Measured Values & Figures detected by UPS If you would like to check the measured values & figures detected by the UPS, please use scroll up and scroll down key pads. When you use scroll down key pad, the LCD display will illustrate as Drawing C(Voltage from Utility Input) D

  • INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 18 3.5.4 UPS Default Data and Special Function Execution 1. After UPS completely starts up, press key pad to change the LCD display screen to drawing Q1.

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 19 V2 * It shows the UPS is operated in “Eco mode”. V3 * It shows the UPS is operated in “CVCF 50Hz mode”. V4 * It shows the UPS is operated in “CVCF 60Hz mode”. W * Output Voltage Adjustment % is from 0% to 3% or -0% to -3%. X * It shows UPS Identification Number

  • INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 20 5. Drawing T means the bypass frequency window of the Inverter Output, the acceptable setting values are ±3Hz and ±1Hz. 6. Drawing U means the

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 21 3.5.6 UPS Is Off Due to Unknown Reason and Its Trouble Shooting 1. If there is a serious abnormal condition occurred, the UPS will lock it itself in “OFF” position as shown in drawing AA and a abnormal message will show on the LCD screen. 2. After 3 seconds, all messages will be locked except Bypass messages (LED & LCD ). In case the Uti

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 22 4. Troubleshooting Guide 4.1 Trouble Shooting When the UPS malfunctions during operation, you may check the followings: a. Are the wirings of input and output correct? b. If the input voltage of the Utility is within the input window of the UPS? In case problems or symptoms still exist, please proceed the followings for proper adjustment. Sh

  • INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 23 5. Bundled Software Installation Guide 5.1 Hardware Installation 1. Connect the male connector of RS232 cable to the UPS communication port. 2. Conn

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 24 6.4 DCE (Dry Contact)-B card  The pin assignments of 10-Pin Terminal: 1 2 3 4 5 6 7 8 9 10 Pin 1: UPS on Bypass mode. Pin 2: Utility Abnormal Pin 3: Utility Normal Pin 4: Inverter On Pin 5: Battery Low Pin 6: Battery Bad or Abnormal Pin 7: UPS Alarm Pin 8: Common Pin 9: Shutdown

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 25 1 2 3 6.6 The Installation of those Interface Cards

  • INFOSEC UPS SYSTEM E6 LCD-RT, INFOSEC UPS SYSTEM – 4 rue de la Rigotière – 44700 Orvault – France – www.infosec-ups.com Hot Line Tel : +33 (0)2 40 76 15 82 – fax : +33(0)2 40 94 29 51 – [email protected] – 04 09 AA XX 201 19 26 7. Specifications E 6 LCD 5000 RT E 6 LCD 6000 RT E 6 LCD 8000 RT E 6 LCD 10K RT E 6 LCD 10K RT TM NPUT Voltage Range (Vac) 160-280 277 - 485 Frequency (Hz) 45 / 65 Hz Number of phases Single phase + ground Three phase, R, S, T + Neutral + Ground Input Power factor > 0,99 (full

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Webasto Thermo Top E Installation instructions manual webasto/thermo-top-e-8C4.pdf 26 Apr 2023 32
2 Kettler 01438-000 Operating instructions manual kettler/01438-000-152.pdf 17 Apr 2023 28
3 Copper Creek EDA-33 Operation manual copper-creek/eda-33-12U.pdf 28 Feb 2024 2
4 Pro-Ject Audio Systems Debut Carbon RecordMaster HiRes User manual manual pro-ject-audio-systems/debut-carbon-recordmaster-hires-Q5F.pdf 16 May 2023 16
5 Fishman Loudbox Owner's manual fishman/loudbox-M9N.pdf 30 Sep 2022 12 1.23 Mb
6 Nvidia VCQFX4500X2 Supplementary manual nvidia/vcqfx4500x2-TE3.pdf 25 Jan 2024 1

Similar Resources:

  • Quantum

    DXi4800

    (2 pages)
    DXi4800 QUICK STARTUsing variable-length deduplication, the DXi4800 provides scalable, backup storage. The DXi4800 provides easy to configure disaster recovery protection when it is paired with one or more DXi system as a replication target. For complete documentation, including pre-installation requirements, see the DXi4800 Documentation Center: www.quantum …
  • LEGRAND

    Ekinoxe 327 13

    (4 pages)
    N0064GG7/ 02Ekinoxe™327 13 / 14 / 15/1925/30 m25/30 mDémodulateurDecoder25 m327 13 327 14/19327 13 327 14/15/19327 15327 12/32327 34327 25329 10/11/12/15516 92/93517 51/56 …
  • Integra

    Xmart OPTIMA-31 10K

    (52 pages)
    ENGLISH Xmart OPTIMA-31 10K / 20K / 30K VER 1705.02 VER. 1705.02 USER MANUAL OPTIMA-31 10K / 20K / 30K 3 Phases IN (380/220V) - 1 Phase Out (220V) ONLINE-DOUBLE CONVERSION UPS ____________________________________________________________________________________________________________________________________ ▪ Technical information on th …
  • Koblenz

    4816 R

    (4 pages)
    BCENTROS DE SERVICIO, REFACCIONES Y CONSUMIBLESPara mayores informes sobre un centro de servicio autorizado cercano a su domicilio visite nuestro sitio de internet: www.koblenz-energia.com.mx o llame sin costo al: 01 800 849 4711 o contáctenos: [email protected] Y REFACCIONES EN TODA LA REPÚBLICAGUADALAJARA, JAL.CINCINNATI No. 125SECTOR …
  • Para systems

    PRO500LCD

    (14 pages)
    User's ManualPRO-LCDSeries UPSPara Systems, Inc.1455 Lemay Dr.Carrollton, TX 75007Phone: 1-972-446-7363Fax: 1-972-446-9011Internet: minutemanups.comUPS Sizing: sizemyups.comPN - 34000407 R2 …
  • Toshiba

    4200 FA XT

    (1 pages)
    T42F3F150FAMXNOne-Line Drawing4200FA XT UPS, 15 kVA CapacityIsolated Redundant System, Shown with 3-Breaker External Bypass SwitchJEDATE 08/15/05AC Input 208/120V3Ph/4W60HzTOSHIBAINTERNATIONAL CORPORATIONHouston Texas, USATHIS MATERIAL IS THE EXCLUSIVE PROPERTY OF TOSHIBA INTERNATIONAL CORPORTION AND SHALL NOT BE REPRODUCED, USED, OR DISCLOSED TO OTHERS UNL …

Comments, Questions and Opinions: