Manualios.com

Bioclimatic PAP SERIES Installation, Operation And Maintenance Manual

  • PAP SERIES Air Cleaner
  • maeqic7U0aCSk
  • Installation, Operation And Maintenance Manual
  • PDF / Adobe Acrobat Reader
  • 11

Bioclimatic PAP SERIES Manual Online:

3.5, 2310 votes
Bioclimatic PAP SERIES User Manual
Bioclimatic PAP SERIES User Guide
Bioclimatic PAP SERIES Online Manual

Text of Bioclimatic PAP SERIES User Guide:

  • BIOCLIMATIC PLENUM AIR PURIFICATION SYSTEM PAP SERIES INSTALLATION, OPERATION & MAINTENANCE MANUAL Bioclimatic Air Systems 600 Delran Parkway Delran, NJ 08075 USA Tel. (856) 764 4300 Fax. (856) 764 4301 ©Copyright Bioclimatic Air Systems LLC 1997, 2000, 2002, 2007, 2009 286/Feb 2009

  • Bioclimatic PAP SERIES, BIOCLIMATIC PLENUM AIR PURIFICATION SYSTEM PAP SERIES TABLE OF CONTENTS 1 INTRODUCTION.............................................................................................................................1 1.1 Disclaimer .................................................................................................................................1 1.2 Receiving ...................................................................................................................................1 1.3 Handling ...........................................................................................................

  • Bioclimatic PAP SERIES, 1 INTRODUCTION 1.1 Disclaimer These instructions are submitted with the implicit understanding that: 1.1.1 This manual is to guide the user of Bioclimatic Air Systems equipment in the proper installation, operation and maintenance procedures to insure maximum equipment life with efficient operation. 1.1.2 The customer has assigned competent maintenance and operating personnel to the system described herein and will assume operational and maintenance responsibility upon start-u

  • Bioclimatic PAP SERIES, treatment and destroy its protective value. Always touch-up scratched surfaces prior to installation and start-up. 1.4 Storage When storing equipment, care must be taken to protect electrical connections, leads and finished surfaces from moisture, and contamination. Do not store the unit outdoors. Do not store any other material on top of equipment. Periodic inspections of the equipment should be made until it is ready to be put into service. Remove all filters from equipment when storing. NOTE: If equipm

  • Bioclimatic PAP SERIES, APPLY IF REPAIRS, REPLACEMENTS, OR ALTERATIONS ARE MADE BY OTHERS WITHOUT THE SELLER’S PRIOR WRITTEN AUTHORIZATION. IN THE EVENT THE STATE IN WHICH THE EQUIPMENT IS INSTALLED DOES NOT PERMIT THE LIMITATION OR EXCLUSION OF IMPLIED WARRANTIES OR CONDITIONS UNDER GIVEN CIRCUMSTANCES, THE PROVISIONS OF THIS WRITTEN WARRANTY ARE IN ADDITION TO AND NOT A MODIFICATION OF THE STATUTORY WARRANTIES AND OTHER RIGHTS AND REMEDIES PROVIDED BY SUCH LAWS. NOTE: “ANY MODIFICATION TO ORIGINAL EQUIPMENT BY ANY COMPANY OR PERSON OTHER THAN THE MANUFACTURER WILL SERVE TO CANCEL AND VOID ALL OF THE SELLER’S LIABILITY UND

  • Bioclimatic PAP SERIES, Refer to the wiring diagram for proper wiring connections. Mount and wire any field installed items as indicated on the factory supplied wiring diagram. When mounting field installed components, do not jumper out or rewire any factory wiring without written authorization from MeadWestvaco Air Systems. (Violation will void warranty.) Pay particular attention to proper grounding of the unit. NOTE: Unit installation and interconnect wiring between the PAP and the Liebert air conditioning unit is to be performed only by or under supervision of a licensed electrician or

  • Bioclimatic PAP SERIES, 2.3 Ionization Tube Installation Install ionization tubes as follows: 2.3.1 Screw tubes into socket by holding the leaf spring clear of tube surface. 2.3.2 Turn tube into socket by the polycarbonate base. 2.3.3 After tube contacts base, tighten an additional 1/8 to 1/4 turn. Do not use hand tools to tighten tubes, as they will damage the glass tubes. 2.3.4 Ensure leaf spring is in contact with outer mesh. NOTE: The ionization tubes are fragile - Handle With Care. 2.4 Filter Installation When installing filters, refer to the filter label located on the inside of the access panels. This label itemizes all fi

  • 3.1.1 Fibrous Filter Arrangement Prefilters are of the disposable panel type with a rated average efficiency of 20% by the ASHRAE Standard 52.2 test method. The primary filter has a rated average efficiency of 60% by the ASHRAE Standard 52.2 test method, using atmospheric dust. Filters are listed Class 2 by Underwriters' Laboratories. 3.1.2 Polarized

  • Bioclimatic PAP SERIES, 4 SYSTEM START-UP 4.1 General Before starting the System, a complete inspection should be made to ensure that all the equipment is installed for safe and proper operation. It is particularly important that the system is free of all foreign objects. Be sure all access panels are securely closed. 4.2 Inspection Check List Unit securely mounted _____ Unit properly wired _____ Filters installed properly _____ Surface continuity between filters and seal surfaces _____ Wipe entire section clean _____ Properly rated fuse present in generator's fuse holder

  • Bioclimatic PAP SERIES, The fibrous filters require periodic maintenance in order to ensure satisfactory system performance over an extended period. The filter change light indicates when the fibrous filters should be replaced. When the filter change light illuminates, the prefilter ONLY should be changed according to the procedure indicated below. If the filter change light is not lit when the unit is started, the primary filter NEED NOT BE CHANGED. If the filter change light remains lit after starting the unit, replace the primary filters. A

  • Bioclimatic PAP SERIES, NOTE: Do not attempt to remove the tube's outer electrode. 5.1.2.3 Rinse with clean water after washing. 5.1.2.4 Replace ionization tubes only after they are completely dry. Pay special attention to removing moisture from the polycarbonate base. 5.1.2.5 Screw tube into socket by holding the leaf spring clear of tube surface. Turn tube into socket by the plastic base. After tube contacts base, tighten an additional 1/8 to 1/4 turn. NOTE: Do not use hand tools to tighten tubes, as they will damage the glass tubes. 5.1.2.6 Make sure that the leaf spring is in

Related Products and Documents (Air Cleaner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Acer Aspire 1360 Series Manual do utilizador acer/aspire-1360-series-2QR.pdf 17 Nov 2023 104 3.65 Mb
2 Hawking HMPS1U Quick installation manual hawking/hmps1u-714.pdf 23 Dec 2023 21
3 Mitsubishi Electric PUHY-P72THMU-A Service handbook mitsubishi-electric/puhy-p72thmu-a-EQL.pdf 05 Jul 2023 326
4 Nokia 300 Operation & user’s manual nokia/300-84S.pdf 26 Oct 2022 68
5 Jenn-Air JGD8348CDP Service manual jenn-air/jgd8348cdp-61Y.pdf 10 Jun 2023 43
6 D-Link DAP-1320 Operation & user’s manual d-link/dap-1320-JTQ.pdf 08 Jan 2023 63 4.75 Mb

Similar Resources:

  • Quantum

    LC - 5500

    (4 pages)
    Customer ServiceIf you have a question about your air purifier, call our toll-free customer service number. Before calling, please note the model, type and serial number and fill in that information below. These numbers can be found on the back of the air purifier. This information will help us answer your question more quickly.MODEL:__________ SERIAL:_ …
  • Clean Air

    AtmosAir Everest

    (15 pages)
    EverestInstallation and Operation ManualOUR MISSIONTo improve health and wellness by actively restoring indoor air to its pure, natural state where no pollution or contaminants exist, while reducing energy use and emissions in the process.AtmosAir.comCAG-06-21-001IMPORTANTSave this Document for Future Reference & Warranty Information …
  • Briggs & Stratton

    204400

    (20 pages)
    COPYRIGHT by BRIGGS & STRATTON CORPORATIONAll rights reserved. No part of t his material may be reproduced or transmitted,in any form or by any means, electronic or mechanical, including photocopying,recording or by any information storage and retrieval system, without permissionin writing from Briggs & Stratton Corporation.PRINTED IN U.S.A.FORM MS-- …
  • Germ Guardian

    Hygia 4.0

    (10 pages)
    Germ GuardianHygia 4.0Table Top Air PurifierUSE & CARE INSTRUCTIONSDate PurchasedmonthyearMODEL NO. AC-40001 Year Limited Warrantywww.germguardian.com1-866-603-5900™E-1English Manual..........................................................E-1French Manual ..........................................................F-1Spanish Manual ..................... …
  • Blueair

    3210

    (244 pages)
    Blue3210/3410User ManualManuel utilisateurManual del usuarioManuale per l’utenteBedienungsanleitungGebruikshandleidingPodręcznik użytkownikaKorisničko uputstvoKullanım KılavuzuBruksanvisningBrukerhåndbokKäyttöohjeBrugervejledningPanduan Pengguna  …
  • Karcher

    K 2.91 M

    (24 pages)
    High Pressure Washer Operator ManualOverview ........................................................................ 2Precautions ................................................................ 2-4Assembly Instructions ................................................... 4Operating Instructions ................................................... 5Using the …

Comments, Questions and Opinions: