Digital Equipment Corporation HA3000 Installation Manual

Digital Equipment Corporation HA3000 Manual Online:

4.3, 2565 votes
Digital Equipment Corporation HA3000 User Manual
Digital Equipment Corporation HA3000 User Guide
Digital Equipment Corporation HA3000 Online Manual

Text of Digital Equipment Corporation HA3000 User Guide:

  • November 1991 The information in this document is subject to change without notice and should not be construed as a commitment by Digital Equipment Corporation. Digital Equipment Corporation assumes no responsibility for any errors that may appear in this document. Possession, use, duplication, or dissemination of the software described in this documentation is authorized only pur

  • Digital Equipment Corporation HA3000, INSTALLATION 4–11 TB1 1 12 POS. NEG.GND. MKV-A2210-91 UPS BATTERY CABINET CONTROL WIRING TB1-1 QF1 24 Vdc UV RELEASE TB1-2 TB1-3 TB1-4 TB1-5 TB1-6 NOT USED N.O. COMM. NOT USED TB1-7 TB1-8 DC GROUND FAULT DETECTOR TB1-9 TB1-10 SMOKE DETECTOR CONTACTS TB1-11 +24 Vdc TB1-12 COMM. SMOKE DETECTOR POWER SUPPLY QF1 AUXILIARY CONTACT Figure 4–4 UPS Battery Cabinet Power and Control Wiring Connections 4.3.3 Two UPS Battery Cabinets/HA32A UPS Installation When two UPS Battery Cabinets are required to meet the specified backup or protection time, each should be installed according to the directions in Section

  • Digital Equipment Corporation HA3000, INSTALLATION REFERENCE CHECKLISTS 1–7 1.3.5 HA32J/K UPS Distribution Cabinet The electrician’s responsibilities during the installation of the HA32J/K UPS Distribution Cabinet are listed below. Check Off Function Task Cable Entry/Exit Use the factory installed distribution cable knockout panels located behind the dead-front panels. Input power to this cabinet is routed through the left-side cable feed area (Figure 4–19). Input Power Cables (without isolation/step-down transformer) Route the three phase conductors, the neutral conductor, a

  • Digital Equipment Corporation HA3000, INSTALLATION 4–35 4.6.3.2 Output Cable Installation Follow the procedure below to install the output cables. 1. Remove the appropriately sized knockout plug from the conduit panel located below the panelboard. 2. Remove the locknut and bushing from the fitting at the end of the cable and use them to install the cable in the knockout hole, feeding the cable conductors through the hole. 3. Strip the insulation from the end of each cable wire, leaving 5/8-inch exposed copper wire. 4. Connect the cable wires to their respective terminations as shown in the following chart: Color Signal Termination White Neutral Neutral Bus Black Phase A Top CB Terminal Red

  • INSTALLATION 4–23 C B A TB1 TB2 1 2 3 4 5 6 HA32C/E HA32A 1 2 3 6 5 4 6 5 4 1 2 3 A B C TO CHARGER PLUG-IN MODULE TO CHARGER PLUG-IN MODULE TO CHARGER PLUG-IN MODULE MKV-A2217-91 Figure 4–14 UPS Cabinet with Input Harmonic Current Filter Installed 4.4.2 Control/Interface Wiring Connect the two control wires provided with the UPS Auxiliary Cabinet to the UPS cabinet

  • Digital Equipment Corporation HA3000, 2–4 SITE PREPARATION 50.8 mm (2.00 in) 200 mm (7.88 in) 356 mm (14 in) 800 mm (31.5 in) MOUNTING HOLES 9 mm DIAMETER (0.375 in) 4 PLACES 817 mm (32.18 in) REMOVABLE COVER PLATE BOTTOM CABLE ENTRY AREA AIR INTAKE DRAW-OUT AIR FILTER (REMOVE DURING SHIPPING) 86.4 mm (3.40 in) BACK BOTTOM VIEW LOOKING UP FRONT MKV-A2202-91 Figure 2–3 Bottom View, 60 and 80 kVA Models For UPS equipment installed on a raised computer room floor, two floor through-holes should be provided beneath the enclosure. One is for cabling and the other serves as an air inlet for the cooling air required by the

  • Digital Equipment Corporation HA3000, B–2 SPECIFICATIONS Inverter AC Output Ratings Refer to Table B–1 for nominal voltage (Vac) values available. Voltage: Nominal value ±1% for all conditions of line, load, and temperature Frequency: Normally synchronized to the bypass ac input source (when available); otherwise, the output frequency is the nominal value ±0.1% Phases: Three-phase, phase rotation A, B, C Wires: Three or four. The UPS inverter output is normally a Wye configuration with the neutral grounded. A three-wire delta load can be connected to the UPS inverter output, but the phase connections cannot b

  • Digital Equipment Corporation HA3000, 4–40 INSTALLATION 4.10 HA320-B1 SMOKE DETECTOR The Smoke Detector is mounted on the rear frame of the UPS Battery Cabinet. The Smoke Detector requires four (4) control wires if it has been installed in the UPS Battery Cabinet. Use the following procedure to connect the Smoke Detector control wires between the UPS Battery Cabinet and the UPS cabinet control wiring interface: 1. Connect a control wire from TB1-9 in the UPS Battery Cabinet to TB1-9 in the UPS cabinet. 2. Connect a control wire from TB1-10 in the UPS Battery Cabinet to TB1-10 in the UPS c

  • Digital Equipment Corporation HA3000, SPECIFICATIONS B–11 Table B–10 UPS Distribution Cabinet Specifications Model Number UPS Output Rating (kVA) Input Voltage (Vac) Maximum Input Current (Amps) Output Voltage (Vac) Maximum Output Current (Amps) Weight (kg/lbs) HA32J-AT 1 20 - 40 208/220 222 208/220 222 225/495 HA32K-AT 1 60 - 80 208/220 222 208/220 222 239/525 HA32J-AH 20 208 55.5 208 55.5 352/775 HA32J-BH 20 480 24.1 208 55.5 352/775 HA32J-DH 20 220 55.5 220 55.5 352/775 HA32J-AK 40 208 111 208 111 389/855 HA32J-BK 40 480 48.1 208 111 389/855 HA32

  • Digital Equipment Corporation HA3000, SITE PREPARATION 2–9 Table 2–3 UPS Auxiliary Cabinet Weights and Dimensions Output Rating (kVA) HA32D-XX Isolation Transformer Only (kg/lbs) HA32E-PX Input Current Filter Only (kg/lbs) HA32C-XX Isolation Transformer and Input Current Filter (kg/lbs) 20 204/450 154/341 268/591 40 249/550 169/374 328/724 60 327/720 214/473 450/993 80 386/850 260/573 556/1,255 Height of all models: 1,402 mm/55.18 in. Width of all models: 477 mm/18.78 in. Depth of all models: 817 mm/32.18 in.

  • Digital Equipment Corporation HA3000, 4–16 INSTALLATION FRONT BACK TOP RIGHT SIDE VIEW OF UPS AUXILIARY CABINET TERMINAL BLOCK TB1 (LEFT SIDE) TB2 (RIGHT SIDE) GROUND BUSBAR INPUT CIRCUIT BREAKER CB1 ON HA32C/D CABLE TRAYS ISOLATION TRANSFORMER CAPACITOR ASSEMBLY MKV-A2213-91 (RIGHT SIDE) Figure 4–7 UPS Auxiliary Cabinet Cable Trays 4.4.1 Power Cable Connections The UPS Auxiliary Cabinet can accommodate two separate options: the isolation transformer and the input harmonic current filter. Each of these options has its own connection procedure. 4.4.1.1 AC Input Connecti

  • Digital Equipment Corporation HA3000, 4–30 INSTALLATION 4.6 HA32J/K UPS DISTRIBUTION CABINET The HA32J/K UPS Distribution Cabinet is designed to attach to the right side of the HA32A UPS cabinet (Figure 2–7), or to the right side of the HA32C/D/E UPS Auxiliary Cabinet or HA33D/F UPS CSA Cabinet (Figure 2–8), if one or both of these options have been purchased. NOTE The side panels are not provided with the UPS Distribution Cabinet. The right side panel from the UPS cabinet, the UPS Auxiliary Cabinet, or the UPS CSA Cabinet must be removed and attached to the right side of the UPS Distribution Cabinet after in

  • INSTALLATION 4–9 4.3 HA32B UPS BATTERY CABINET The UPS Battery Cabinet is shipped with the lower front and lower rear panels removed. The hardware needed to install these panels is in place. 4.3.1 General Installation The UPS Battery Cabinet is designed for use with the HA32A UPS equipment only. Generally, the UPS equipment is installed as close as possible to the UPS Battery Ca

  • HA3000 UPS RECEIVING AND HANDLING 3–5 3.3.5 Moving Unit to Final Position Digital recommends that the HA3000 series cabinets be left on the rolla-lifts for moving them to the final position. If the trucker/mover/rigger desires, the following procedure can be used to move the HA3000 series cabinet to the final position on the cabinet casters. 1. Ensure that the four caster lift

  • Digital Equipment Corporation HA3000, iv Contents 3 HA3000 UPS RECEIVING AND HANDLING 3.1 GENERAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1 3.2 RECEIVING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–1 3.3 HANDLING . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–2 3.3.1 Removing Unit from Truck . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3–3 3.3.2 Removing Shipping Carton . . . . . . . . . . . . . . . . . . . . . . . . .

  • Digital Equipment Corporation HA3000, INSTALLATION 4–7 4.2.6 Contact Closure Control Wire Connections (TB2) Refer to Figure 4–1 for the location of the control wiring interface in the UPS cabinet, and to Figure 4–3 for detailed connection information. Form "C" dry contacts (rated at 1 A, 24 Vdc, or 120 Vac) are provided. These may be used to remotely annunciate the conditions (1 and 2) below, used to interface with the REPO option signal (3) below, used to interface with customer installed external contacts (4) below, or detect faults in the UPS Auxiliary Cabinet (5) if it is installed: 1. UPS on battery operation 2. Major/minor fault alarm has o

  • Digital Equipment Corporation HA3000, 4–38 INSTALLATION 4.8 HA320-A3 REMOTE ALARM PANEL The Remote Alarm Panel allows the UPS system status to be monitored from a remote location. The unit is mounted on a wall using the four mounting holes located on the back of the unit. For the installation of the Remote Alarm Panel option, six (6) control wires and two (2) power wires must be provided and installed by the customer’s electrician. Use the following procedure to connect the six control wires from TB3 in the Remote Alarm Panel to TB2 and TB3 in the UPS cabinet, and to connect the two p

  • Digital Equipment Corporation HA3000, INSTALLATION 4–17 Table 4–4 HA32C/D/E UPS Auxiliary Cabinet Electrical Specifications Model Number Output Rating (kVA) Input Voltage (Vac) Input Current (Amps) Output Voltage (Vac) Output Current (Amps) Input CB Rating (Amps) With Input Isolation Transformer and Harmonic Current Filter HA32C-AH 20 208 62 208 62 90 HA32C-BH 20 480 30 208 62 40 HA32C-CH 20 480 30 480 30 40 HA32C-DH 20 220 59 220 59 90 HA32C-EH 20 600 24 208 62 40 HA32C-AK 40 208 122 208 122 175 HA32C-BK 40 480 53 208 122 90 HA32C-CK 40 480 53 480 53 90 HA32C-DK 40 220 115 220 115 175 HA32C-EK 40 600 43 208 122 60 HA32C-AM 60 208 181 208 181 250 HA32C-BM 60 480 79 208 181 100 HA32C-CM 60 480 79 480 79 100 HA32C-DM 60 22

  • Digital Equipment Corporation HA3000, 4 INSTALLATION 4.1 GENERAL This chapter contains the installation procedures for the HA32A UPS cabinet, the HA32B UPS Battery Cabinet, the HA32C/D/E UPS Auxiliary Cabinet, the HA33D/F UPS CSA Cabinet, the HA32J/K UPS Distribution Cabinet, the HA320-AA/AB Remote Status Panel, the HA320-A3 Remote Alarm Panel, the HA320-C2 DC Ground Fault Detector, and the HA320-B1 Smoke Detector. 4.2 HA32A UPS Cabinet Before making any electrical connections, check that all ac input feeder circuit breakers or fused switches that will interface with the UPS cabinet are in the off position. In addition, make certain that the UPS cabinet ac input (MAINS1) circuit

  • Digital Equipment Corporation HA3000, INSTALLATION REFERENCE CHECKLISTS 1–9 1.4 DIGITAL SERVICES RESPONSIBILITIES The following sections contain the responsibilities of Digital Services during site preparation, delivery/handling, and initial startup of the HA3000 series UPS. 1.4.1 Site Preparation Digital Services responsibilities during site preparation are listed below. Check Off Function Task Physical Size and Weight Aid the customer in obtaining the size and weight information on the HA3000 series cabinets that are to be installed. Refer to the HA3000 20-80 kVA Uninterruptible Power System Instal

Related Products and Documents (UPS):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Plantronics WO201 Operation & user’s manual plantronics/wo201-5B3.pdf 11 Jul 2022 28
2 Jenn-Air JMC3215 Use & care manual jenn-air/jmc3215-8V6.pdf 20 Jan 2023 20
3 Asus Eee PC X101 Operation & user’s manual asus/eee-pc-x101-I5N.pdf 18 Feb 2023 46 4.45 Mb
4 Pioneer AVM-P505R Service manual pioneer/avm-p505r-29C.pdf 28 Sep 2023 47
5 Craftsman 917.385391 Owner's manual craftsman/917-385391-O51.pdf 29 Aug 2022 40
6 Dyson DC04 Operation & user’s manual dyson/dc04-MB3.pdf 09 Nov 2022 6 2.21 Mb

Similar Resources:

  • Tripp Lite

    SmartPro Series

    (17 pages)
    Owner’s Manual1111 W. 35th Street Chicago, IL 60609 USACustomer Support: (773) 869-1234 • www.tripplite.comImportant Safety Instructions2Quick Installation3Basic Operation5Storage & Service8Warranty Registration9Copyright © 2007 Tripp Lite. All rights reserved. SmartPro®is a registered trademark of Tripp Lite.Español10Français20SmartPro®& …
  • Rockwell Automation

    1606-XLS240-UPS

    (4 pages)
    Read first ! English 1 Before operating this unit please read this manual thoroughly. Retain this manual for future reference! This device may only installed and put into operation by qualified personnel. Intended Use: This device is designed for installation in an enclosure and is intended for the general use such as in industrial control, office, co …
  • Emerson

    Liebert itON BX

    (2 pages)
    The UPS has six battery backup outlets that provide powerwhen the UPS operates on battery. (See Figure 2 on next page)Step 5 Connect the LoadsStep 6 Connect Modem/Phone/Network for Surge Protection The UPS has two RJ-45 jacks for modem/phone/network.(See Figure 2 on next page)Connect a single modem/phone line intosurge-protected “IN” outlet on the back p …
  • Borri

    INGENIO COMPACT

    (134 pages)
    l�un I Jet , ИБП Borri Ingenio Compact - руководство по эксплуатации. ЮниджетПостоянная ссылка на страницу: https://www.uni-jet.com/catalog/istochniki-besperebojnogo-pitaniya/on-line-ibp-10-100-kva/borri-ingenio-compact.html …
  • Vertiv

    Liebert GXT5-6000IRT5UXLN

    (56 pages)
    LIEBERT® GXT5™ UPS 230‑V5,000–6,000VAQuick Installation Guide590-1929-664A/SL-70305_REV0 1IMPORTANT: Before installing, connecting to supply or operating your Liebert GXT5 UPS, please review the Safety and Regulatory Statements sheet. For detailed installation, operating, maintenance and troubleshooting information refer to the GXT5 …
  • Tripp Lite

    TE1200

    (5 pages)
    Tripp Lite1111 West 35th StreetChicago, IL 60609 USATelephone: +(773) 869 1234E-mail: [email protected] #: TE1200TE Series 1200VA Tower Line-Interactive 120V UPS with serial port Highlights6 outletsAutomatic Voltage Regulation (AVR) corrects brownouts and overvoltagesLarger scale battery produces significantly longer runtimesSerial port works wit …

Comments, Questions and Opinions: