Text of Digital Monitoring Products XTL Series User Guide:

  • Digital Monitoring Products XTL Series, System Setup XTL Series User’s Guide 31 User # User Name Level* Temp Code Temp Days Areas Arm Only HOW TO FILL IN THIS TABLE User # - TheUserNumberof the person authorized to use the system. Level* - Master or Standard authority. Temp Code-Isthiscodeset to expire? Temp Days - The number of days a temporary user has authority to use the system. Areas-Whatareasdoesthis user have the authority to arm and disarm? Arm Only - Is this user restricted to just arming? Refer to the User Codes section of this User’s Guide for additional information. Y N 1 2 3 4 5 6 Y N Y N 1

  • Digital Monitoring Products XTL Series, Arming and Disarming XTL Series User’s Guide 13 Arming a Home/Away System 1. Enter your user code. The keypad displays HOME AWAY or HOME SLEEP AWAY(youmayhavethreeareas). 2. Select HOME to arm the Perimeter only. 3. Select SLEEP to arm the Perimeter and Interior. 4. Select AWAY toarmthePerimeter,Interior,andBedroom. 5. The system displays any faulted and bypassed zones in the following order: faulted burglary zones, bypassed burglary zones,faulted24-hourzones,andbypassed24-hourzones. 6. At this point you can force arm or bypass any faulted burglary zones. A zone that is force armed is res

  • © 2013 Digital Monitoring Products, Inc. Information furnished by DMP is believed to be accurate and reliable. This information is subject to change without notice. Silencing an Alarm When the alarm siren is sounding, enter your user code or present your card to a keypad during the Status List display. All/Perimeter or Home/Sleep/Away System IS THIS A FALSE

  • Digital Monitoring Products XTL Series, 22 XTL Series User’s Guide User Menu Using the Zone Monitor Function 1. Access the User Menu. 2. PresstheCOMMANDkeyuntilZONE MONITOR? displays. 3. Press any Select key. The keypad displays PERIM ALL NBR. 4. Select PERIM to place all disarmed perimeter zones into Zone Monitor. 4a. The keypad displays PERIM? ADD RMV. 4b. Select ADD to add all perimeter zones to Zone Monitor. 4c. Select RMV to remove all perimeter zones. 5. Select ALL to place all disarmed zones into Zone Monitor. 5a. The keypad displays ALL? ADD RMV. 5b. Select ADD to add all disarmed zones to Zone

  • User Menu XTL Series User’s Guide 19 User Check-in User Code Level: Master or Standard. Function: This feature allows you to monitor the arrival of children from school or employees to work by having a special Check-in Report sent to your email address or cell phone if programmed. Appendix D describes the Email/Cell Phone option. Sending a Chec

  • Arming and Disarming XTL Series User’s Guide 15 6. The system displays any faulted and bypassed zones in the following order: faulted burglary zones, bypassed burglary zones,faulted24-hourzones,andbypassed24-hourzones. 7. At this point you can force arm or bypass any faulted burglary zones. A zone that is force armed is restored into the system if it later returns

  • Digital Monitoring Products XTL Series, Arming and Disarming XTL Series User’s Guide 17 Arming Function System Operation: Home/Sleep/Away, or All/Perimeter. You can use theArming shortcut keys, 1, 3, 6, and 7 when the systemisdisarmed.Youmaybepromptedtoenteryourusercode. If any zones are faulted, select force arm or bypass. Refer to the Arming Section for detailed arming operation. Home/Sleep/Away Arming Arm Home — Press 3 for 2 seconds to arm the perimeter. Arm Sleep — Press 7 for 2 seconds to arm the perimeter and interior areas and leave the bedroom area off. This shortcut key is ava

  • Digital Monitoring Products XTL Series, 6 XTL Series User’s Guide Introduction ALARM CANCELLED An Alarm signal just sent to the central station was cancelled because a user code was entered after the alarm was sent. Also, an Alarm Cancel signal is sent to the Central Station. ALARM VERIFIED Avalidburglaralarmhasoccurredandhasbeenmanuallyveried bytheuser.ThealarmsystemalsotransmitsaVERIFYmessageto the Central Station. ENTER CODE The system requires you to enter a personal user code. User codes can be used for turning your system

  • Digital Monitoring Products XTL Series, 8 XTL Series User’s Guide Introduction Instant Zone Exterior windows and non-entry doors, or interior protection devices, are typically not programmed with delay times. If these zones fault while the system is armed, an alarm occurs instantly. 24-Hour Zone A24-hourzoneisnotturnedonoroffbyarmingordisarmingyour system. Some examples of 24-hour zones are re zones, panic zones, and temperature control zones. Areas An area is made up of burglary zones that can be armed or disarmed together. The Perimeter area, for exa

  • Digital Monitoring Products XTL Series, Appendix C XTL Series User’s Guide 37 ARMING AND DISARMING AN AREA SYSTEM PressCOMMAND,thekeypaddisplaysARM DISARM?. Press the Select key under either option. The keypad displays ENTER CODE: -. Present your card to the keypad logo. Once the system validates the card, all areas accessible by you arm or disarm automatically. ENTRY DELAY All Systems - Once the protected door is opened and the entry delay starts, the keypad displays ENTER CODE:

  • Digital Monitoring Products XTL Series, 26 XTL Series User’s Guide User Menu Permanent Schedules User Code Level: Master only. 1. Access the User Menu. 2. PresstheCOMMANDkeyuntilSCHEDULES? displays. Press any Select key. The keypad displays PRM EXT. Select PRM. 3. The keypad next displays the day of the week you want the schedule to start as SUN MON TUE WED. Press the COMMANDkeytoshowtheremainingdaysoftheweekand then Select the start day. 4. The keypad displays OPENING TIME?.Press

  • Digital Monitoring Products XTL Series, Cut along dotted lines. Cut along dotted lines. Text For this action OFF(Outputnameor#) TurnstheOutputspeciedtoOFF MOMENTARY(Outputnameor#) TurnstheOutputspeciedtoMOMENTARY Z-WAVEHELP ListofZ-Wavecompatibletextcommands STAUS LIGHTS To receive a status update for all light devices TURNON(Lightname) TurnsthespeciedlighttoON TURNON(Lightname)(Dimmerlevel) Turnsdimmerlightontoaspecictemp TURNOFF(Lightname) Turnsthespecie

  • User Menu XTL Series User’s Guide 21 Bypass Zones User Code Level: Master or Standard. Function: Allows you to bypass a zone prior to arming the system. Bypassingisusuallydonewhenazonecannotberestoredtonormal andyouwanttoarmthesystem.Oncebypassed,thesystemdoes not respond to any activity on the zone

  • Cut along dotted lines. MyAccess™ Text Messaging Quick Commands PanelPhoneNumber:________________________ AreaNames: 1. ________________________ 2. _________________________ 3. ________________________ 4. _________________________ 5. ________________________ 6. _________________________ OutputNames: 1. ________________________ 2. __________

  • Digital Monitoring Products XTL Series, 40 XTL Series User’s Guide Appendix D MyAccess™ Text Messaging Commands For use with the XTL and XTLC only Yoursystemmaybeprogrammedtoallowsimpletextmessagesto be sent to the security system and perform basic user operations. Bytextingamessagefromyourcellphone,thefollowingactions can be performed:Arm/Disarm, CancelAlarm, turn Outputs On/ Off,checkArmedStatus,Turnonandofflights,Lock andunlock doors, and Set the thermostat. The user that is texting commands to the system must have the authority t

  • Digital Monitoring Products XTL Series, Appendix D XTL Series User’s Guide 39 Appendix D Email/Cell Phone Message User’s Guide YourXTLSeriessecuritysystem’sreportingcapabilitycanbeused tosendreportstoanemailaddressorcellphonenumber(XTLand XTLConly)inmuchthesamewayassomeonesendingyouanemail woulddo.You canreceive reportsofalarms,troubles,orsystem armings and disarmings and know at a glance your

  • Digital Monitoring Products XTL Series, 32 XTL Series User’s Guide Appendix A Appendix A About the Display Events Section User Code Level: Master or Standard. WhileintheDisplayEventsfunction,usetheCOMMANDandBack Arrow keys to move forward or backward through the list of events. To view more information about each display, press the Select key as directed in the explanations below. Using the Display Events Function 1. Access the User Menu. 2. Press the COMMAND key until DISPLAY

  • Digital Monitoring Products XTL Series, 34 XTL Series User’s Guide Appendix A Supervisory Event Displays This displays the automatic test report date and time. Description MSG 11:58P 10/17 AUTO RECALL The test report was sent to the central station at the date and time shown. System Monitor Event Displays This displays any problems with the system AC power or battery. Description TBL 11:41A 10/17 AC POWER An AC failure occurred at 11:41 AM onOctober17. SystemMonitorEventTypes-Therearetwoeventtypes: TBL - Trouble RST - Restore SystemMonitorEventNames

  • 16 XTL Series User’s Guide Arming and Disarming Disarming an Area System 1. PresstheCOMMANDkeyuntilARM DISARM displays. During entry delay this process starts at step 3 below. 2. Select DISARM to disarm areas. 3. The keypad displays ENTER CODE: . Enter your user code andpressCOMMAND.ThekeypaddisplaysALL? NO YES. 4.

  • Digital Monitoring Products XTL Series, Arming and Disarming XTL Series User’s Guide 9 Arming and Disarming How Your System Operates Your system has been programmed to operate in one of three modes: Area, All/Perimeter or Home/Sleep/Away. • All/Perimeter — Your burglary protection is divided into two areas: Interior and Perimeter. Perimeter arming is for when you are staying inside but want the comfort of knowing the exterior doors and windows are armed. Perimeter arming allows you to move freely about inside

  • Digital Monitoring Products XTL Series, Appendix D XTL Series User’s Guide 43 Common Keypad Displays Listed below are several keypad messages you may see on the display. Follow the instructions in the Possible Solutions column to correct the problem. In many cases, you need to call a service person to correct the problem. Displays not discussed here indicate your service representative should be called. Message Tone at Keypad Meaning Possible Solutions INVALID CODE No The user code you entered is not recognized by the system. Check the user code and try again. CLOSING TIME Yes The schedule has expired but the system has not been armed. Users still on the premises are

  • Digital Monitoring Products XTL Series, 20 XTL Series User’s Guide User Menu Sensor Reset User Code Level: Master or Standard. Function: Clears Fire and Supervisory zone alarms and trouble keypad displays. Sensor Reset also clears low battery displays from wireless sensors that have restored. Make sure all smoke is cleared from around the area of the smoke detectors before performing a Sensor Reset to prevent the alarm from occurring again. Resetting the Sensors 1. Access the User Menu. 2. When SENSOR RESET? displays, press any Select key. The keypad displays SENSORS OFFforvesecondsfollowedby SENSORS ON. 3. The ke

  • Digital Monitoring Products XTL Series, 2 XTL Series User’s Guide Practice your escape plans Devising an escape plan is only the beginning. For the plan to be effective everyone should practice escape routes from each room. Second Floor Building Front Building Back First Floor Fire Escape Window Ladder Figure 1: Sample Escape Route Map Early detection The best way to survive a re or other emergency isto get out early. A re alarm system installation, with smoke and carbon monoxide detectors in each room, can greatly decrease your risk of loss or injury. Emergency Evacuation Plans Overview The National Fire

  • Digital Monitoring Products XTL Series, XTL Series User’s Guide i XTL Series User’s Guide Table of Contents Section Page Section Page Introduction ..............................................................1 XTL, XTLN, XTLN-WiFi, and XTLC Systems ........................1 About Your Security System .............................................1 Emergency Evacuation Plans ............................................ 2 Keypads .........................................................................3 Special Keypad Tones ......................

  • Digital Monitoring Products XTL Series, 42 XTL Series User’s Guide Appendix D Check Armed Status Text Command Allows you to check the system armed status. If armed, the system will send a message stating the type of system you have followed by ON,suchasALLSYSTEMONorHOMESYSTEMON.Ifdisarmedandno openzones,thesystemwillsendSYSTEMREADY.Ifdisarmedwith openzones,itwillsendSYSTEMNOTREADYfollowedbyanyopen zones.AmessageofACPOWERTROUBLEwillindicatewhenapower failureoccurs.I

  • Digital Monitoring Products XTL Series, 12 XTL Series User’s Guide Arming and Disarming installation to send a report of the system disarming to the central sta tion. Z-Wave Lock Disarming:IfyoursystemisinstalledwithaZ-Wave compatible lock, a valid user code entered at the lock will unlock the door and disarm the system. Disarming an All/Perimeter System 1. During the entry delay time, the keypad displays ENTER CODE:. Enter your user code. 2. The keypad displays any zones that went into alarm and any communication

  • Digital Monitoring Products XTL Series, 24 XTL Series User’s Guide User Menu Select YES to restrict this user to arming only.  TheArmOnlyusercodecanbypasszonesnotinanormal condition at the time of arming. 10. After you complete your selections, the keypad displays USER # ADDED. 11.PresstheBackArrowkeyoncetoaddanotheruserortwice to exit the User Menu. Changing User codes User Code Level: Master only. 1. Access the User Menu. 2. PresstheCOMMANDkeyuntilUSER CODES? displays. 3. Press any Select key. The

  • Digital Monitoring Products XTL Series, 10 XTL Series User’s Guide Arming and Disarming Exit Delay: The keypad then displays the exit delay time as it counts down. If the entire system has been armed, your system beeps the exitdelaytoneateight-secondintervalsuntilthelast10seconds whenthekeypadbeepsatthree-secondintervals.Afterexitingthe building,ifyoure-enterduringthecountdowntheexitcountdown restarts, allowing additional time to then disarm or again exit the building during the countdown. This restart can occur only one time. When the exit delay time ex pires,

Related Products and Documents (Security System):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP 995C Series Function manual hp/995c-series-Z4K.pdf 24 Sep 2023 82
2 CDA PC870 Installation, use and maintenance manual cda/pc870-787.pdf 27 Dec 2023 32
3 Philips EasyStar FC8802 Operation & user’s manual philips/easystar-fc8802-D67.pdf 04 Jun 2023 8
4 Niles IntelliControl ICS DMS4 Operation & user’s manual niles/intellicontrol-ics-dms4-6PZ.pdf 05 Aug 2022 50
5 Tripp Lite SU1500XLCD Owner's manual tripp-lite/su1500xlcd-R54.pdf 08 Nov 2023 96 35.1 Mb
6 Sharp R-3A53 Service manual sharp/r-3a53-3RJ.pdf 05 Dec 2023 47 5.38 Mb

Similar Resources:

  • Potter

    RA-6075R

    (2 pages)
    MFG. #5406080 - REV B9/11PRINTED IN USA PAGE 1 OF 2RA-6075RLCD ANNUNCIATOR INSTALLATIONPotter Electric Signal Company, LLC • St. Louis, MO • Cust Service: 866-956-1211 • Tech Support: 866-240-1870 • Canada: 888-882-1833 • www.pottersignal.comInstall in accordance with installation manual, #5403594.DescriptionThe RA-6075R is a LCD remote annunciator …
  • MOFLASH SIGNALLING

    X450 Series

    (2 pages)
    7.0 Cable GlandThe X450 and LED450 beacons are supplied as standard with 1 x M20 threaded side cable entry with provision for up to 4 supplied to special order.SAFETY WARNINGIf the X450 and LED450 are used at high ambient temperatures, ie over +400C then the cable entry temperature may exceed +700C and therefore suitable heat resisting cable glands must be u …
  • Bosch

    DVR1A

    (2 pages)
    Bosch Digital Video Recorders DVR1A DVR1C DVR4C Divar Divar MR Divar XF DiBos Micro DiBos RackmountSystemOperating System Embedded Embedded Embedded Embedded Embedded Embedded Windows XP Embedded Windows XP EmbeddedRack Mountable No No No Yes Yes Yes Yes YesSDK Available No No No Yes No Yes Yes YesWarranty 3 Years 3 Years 3 Years 3 Years 3 Years 3 Years 3 Ye …
  • Viking

    K-1700-3

    (4 pages)
    • Vandal Resistant Features: 14 gauge, louvered, stainless steel faceplate with stainless steel speaker/mic screen, heavy duty metal keypad and “Call” button• Optional EnhancedWeather Protection (EWP) • Yellow “in use” LED• Volume adjustments for microphone and speaker• Advanced call progress detection: disconnects on busy signal, ret …
  • Digimerge

    DH200

    (2 pages)
    PACKAGE CONTENTS:ATTENTION: • * Channel/ Port configuration and HDD (hard disk drive) capacity may vary by model. Check your package for specific content information.• Monitor and Cameras are not included.• Ethernet Cable, Broadband Router and Computer are required for local and remote monitoring (not included).• For detailed setup and software …
  • Philio Technology Corporation

    PSR07

    (6 pages)
    PSR07 Smart Color ButtonThis device is a multiple functions button switch. It is able toswitch the appliances on/off or adjust the percentage of dimmer.It can also work as a timer. The well designed wall bracket andmagnetic back let the switch can be fixed on the wall. This productcan be included and operated in any Z-WaveTM network wit …