  • Smoke Detector - 2 - Smoke Detector This makes an important addition to security and safety. These smoke detectors are easy to install and configure. The smoke detector must be mounted on the ceiling for maximum smoke detection. These photoelectric type smoke detectors are generally more effective at detecting smoldering fires which smolder for hours

  • AKCP SK00, Smoke Detector - 3 - o The unit auto detects the presence of the Smoke Detector (as Dry Contact sensor) o Disconnect alarm (Note that the smoke detector will be detected as a Dry Contact sensor. See more on this in the configuration of the sensor). Specifications: o Sensor type - open/closed contact switch o Detection type: Photoelectric Chamber o Power Source: 9 VDC o Standby Current: 15 uA max o Alarm Current: 30 mA max o Alarm Sound Level: 85 dB at 3 m o Operating Temp: 5° C - 45° C o Ambient Humidity: 10% - 90% o Sensitivity to Smoke: 3 - 6% Obs/m o Size: 110 mm Ø o Ambient Humidity: 10% to 90% o Maximum CAT5/6 Extensio

  • AKCP SK00, Smoke Detector - 4 - Smoke Detector Placement It is recommended that you install one detector in each room and in separate hallways. If the hallway is over 12 meters long, install a detector at each end. They should be located at the top levels of first-to-second floor stairwells. Install the smoke detectors as close to the center of the ceiling as possible. If this is not possible, mount no closer than 4 inches from a wall or corner. DO NOT install the smoke detectors; Near appliances or areas where normal combustion regularly occurs (cooking areas, furnaces, hot water heaters, florescen

  • Smoke Detector - 5 - HUSH Feature This button on the smoke detector is a combined Test/Hush button to silence false alarms. 1. To cancel a false alarm, press the Test/Hush button located on the cover. The alarm will automatically switch to a reduced sensitivity condition. This reduced sensitivity will last for 10 minutes. The unit will flash the

  • AKCP SK00, Smoke Detector - 6 - Configuration of the Smoke Detector (sensorProbe) The Smoke Detector when first connected to the sensorProbe’s RJ-45 sensor port will be auto sensed as a Dry Contact Sensor. So you would first click on the Dry Contacts & Drivers link, then click on the port that it is connected to as shown in the screen shot above. In the Smoke Sensors settings page you will rename your Smoke Sensor as you wish in the Description field. We can also rename our sensors descriptions in the Descriptions fields then turn the sensor Online by choosing the Online setting for the sensor in the Go Online/Offline field and also make sure that the Normal State for

  • Smoke Detector - 7 - Now we can see that our Smoke Sensor is Online and shows the status of No Smoke. Now if we navigate back to the Summery page we can see the sensor is present there showing the correct status. Note: Please see the Siren / Strobe Sensor User Manual for the step-by-step instructions for using the Smoke Detector to tri

  • AKCP SK00, Smoke Detector - 8 - Configuration of the Smoke Detector (securityProbe) When you first connect the Smoke Detector to the RJ45 port is will be auto sensed online as a Dry contact I/O type sensor. Click the Auto Sense button as shown in the screen shot above. Confirm the popup warning by clicking on the OK button as shown in the screen shot above.

  • AKCP SK00, Smoke Detector - 10 - Now you will click on the down arrow button which will display the list of sensors to choose from. Choose the Smoke Detector as shown in the screen shot above. Now click the Save button.

  • AKCP SK00, Smoke Detector - 11 - As we can now see the Smoke Sensor is Online and is in the Normal state. If the Smoke Sensor still remains in a critical state please check the extension cable and check the LED on the sensor. If you continue having a problem with the sensor being connected contact AKCP Support a [email protected] for more assistance and please include the details of the problem and serial # of the sensor in your email.

  • AKCP SK00, Smoke Detector - 12 - Again, as we mentioned before at the end of the sensorProbe configuration, when we tested the smoke sensors, we found that if these are positioned too close to the florescent lighting, these lights can cause false alerts. You can add time to the “Continuous Time Settings” as shown in the screen shot above to eliminate these false alerts. Additional Information on the Smoke Detectors Test Button & Testing As noted earlier do keep in mind that when testing the Smoke Detectors using real or canned smoke do not press the "Test/Hush" button at least 10 minutes prior to this testing or the detector wi

  • AKCP SK00, Smoke Detector - 13 - Cleaning and Problems with Smoke Detectors As also mentioned earlier these sensors are not designed to be used in dusty or dirty environments. If they must be, then they will need to be cleaned regularly. The picture above clearly shows the dust build up inside the detectors optical chamber. You can see the clear black plastic where we have wiped the dust off compared to the dusty surface. This picture above also shows the dust inside the cover of the Smoke Detect

  • AKCP SK00, Smoke Detector - 14 - This picture above shows the optical chamber of the Smoke Detector after cleaning This concludes the Smoke Detector User manual. Please contact [email protected] if you have any further technical questions or problems setting up your modem or your alerts. Thanks for Choosing AKCess Pro!

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Sencor SPG 3100WH Operation & user’s manual sencor/spg-3100wh-61R.pdf 07 Jan 2024 10
2 Aastra 9216e Installation and user manual astra/9216e-4R4.pdf 11 Jan 2023 28
3 Dreamer Design Exec Instruction manual dreamer-design/exec-N98.pdf 31 Mar 2023 4 1.53 Mb
4 JVC LPT0679-001B Instructions manual jvc/lpt0679-001b-719.pdf 06 Dec 2022 92
5 TomTom GO Operation & user’s manual tomtom/go-7Q7.pdf 29 Feb 2024 84 5.58 Mb
6 Whirlpool WFW87HEDW Use & care manual whirlpool/wfw87hedw-4Q3.pdf 27 Feb 2023 48

Similar Resources:

  • System Sensor

    BEAM200

    (14 pages)
    1 I56-2289-007R 06-10INSTALLATION AND MAINTENANCE INSTRUCTIONSBEAM200, BEAM200SSingle-ended Reected Type Projected Beam Smoke DetectorSPECIFICATIONSGENERALRange: 16 to 230 Feet (5 to 70m); 230 to 328 Feet (70 to 100m) using optional accessory BEAMLRKSensitivity: 25% to 50% Total Obscuration in 6 levels Level 1 = 25% Level 2 = 30% L …
  • Panasonic

    4301

    (2 pages)
    Panasonic Electric Works Fire & Security Technology Europe AB Jungmansgatan 12, SE-211 19 Malmö, Sweden Tel: +46 (0)40 697 70 00 • Fax: +46 (0)40 697 70 99 [email protected] • www.panasonic-fire-security.com Fire alarm systems Analog photoelectric smoke detector 4301 • Constant sensitivity / Service signal at a fixed level of c …
  • System Sensor

    DH400ACDCIHT

    (12 pages)
    D400-64-00 1 I56-991-08RDH400ACDCIHT Air Duct Smoke DetectorINSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 601741-800-SENSOR2, FAX: 630- …
  • Tyco

    MR601TEx

    (7 pages)
    © 2010 Tyco Safety Products PAGE 1 of 7M600 SERIES01B-04-D1255/10Registered Company: Thorn Security Ltd. Registered Office: Dunhams Lane Letchworth Garden City Hertfordshire SG6 1BEEQUIPMENT:PUBLICATION:ISSUE No. & DATE:MR601TEx INTRINSICALLY SAFE ENHANCED OPTICAL SMOKE DETECTORPRODUCT APPLICATION AND DESIGN INFORMATION1. INTRODUCTIONThe MR601TEx Intrin …
  • Nittan

    EVA-PYH

    (26 pages)
    DW1401831 Rev.K1 Sep 18, 2015 1 Instruction Manual EVA-PYH Analog Photoelectric Smoke/Heat Detector Before Installation Please read these instructions carefully and keep for future reference. The information in this document is subject to change without notice. For updates please refer to our website. Do not use the products outside the rated power …
  • Ei Electronics

    Ei 220E

    (6 pages)
    What to do when the Alarm sounds:(1) Open the doors and windows to ventilate.(2) Turn off the appliance where possible and stop usingthe appliance. (The alarm can be silenced immediately bypushing the test/hush button if the level is below 150ppmCO).(3) Evacuate the property leaving the doors and windowsopen.(4)Telephone your gas or other fuel supplier on th …

Comments, Questions and Opinions: