  • Diva RDW 9RN, 21 · CAREFULLY FOLLOW THE INSTRUCTIONS BELOW TO ENSURE THE IDEAL OPERATION OF THE AIR CONDITIONER. · HANDLE THE UNIT WITH CARE AND NEVER TURN THE AIR CONDITIONER UPSIDE- DOWN DURING INSTALLATION. · NEVER REMOVE THE UNIT'S REAR PANEL FOR ANY REASON IN ORDER TO AVOID COMPROMISING OPERATION. · AT THE END OF INSTALLATION, EXPLAIN THE UNIT'S OPERATION TO THE CLIENT USING THE OPERATION AND MAINTENANCE MANUAL. · GIVE THE OPERATION AND MAINTENANCE MANUAL TO THE CUSTOMER. The position of the air conditioner is extremely important for both correct operation and the comfort of the room or area. Choose the unit's position to

  • Diva RDW 9RN, 22 D. We recommend installing the unit at least 200 cm above the floor in order to permit complete and correct air distribution in the room. A distance of at least 15 cm must be kept from the ceiling (see Figure 1) in order to permit correct wall or built-in installation. E.The rear ventilation grills must be free from obstacles to permit a free flow of air. F. Make sure that the flow of air expulsed from the rear grills does not disturb the neighbours and is not directed to an area with a continuous passing of pedestrians. G.The flow of air from the rear grills must not be sent into a closed room because if this expulsed air is injected into an area without free circulation the

  • Diva RDW 9RN, 23 We provide an installation diagram below that summarises all the information found in the respective chapters that explain the various types of installation possible: Wall installation (Page. 4) Built-in installation (Page 7) Ceiling installation (Page 12)

  • 24 ASSEMBLY PROCEDURE 1. Position the supplied paper template on the wall and using a pencil mark the positions of the two holes to be drilled and the posi- tion of the support bracket at a height of around 200 cm from the floor and 15 cm from the ceiling. Unusual installation positions must be worked out case by case. Whenever the paper template has not been provide

  • Diva RDW 9RN, 25 7. Condensate drain preparation Whenever the unit must be removed, make sure to first drain the condensate collection tray to avoid annoying water spills. During transport, always leave the air conditioner positioned upright on a flat surface and never rest it on its front plastic part or on its rear part. N.B.:Whenever it is impossible to send all the condensate created outside the room, see the paragraph "Auxiliary condensate drai- nage" on Page 18. fig. 2 electric heating element pipe fig. 3 Assemble the condensate drainage pipe by firmly pushing and twisting it towards the air conditioner as shown in Fig

  • Diva RDW 9RN, 26 8. Installation of the unit IMPORTANT: Handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will remain in view. Hang the air conditioner to the bracket provided by passing the condensate drainage pipe correctly along the air expulsion pipe and then checking the unit's stability. Rear grills Electric heating element Air pipe Insulated air pipe Fastening bracket Air conditioner Condensate drain Internal conden- sate drainage pipe The pipe protection grills must be applied outside the wall w

  • Diva RDW 9RN, 27 ASSEMBLY PROCEDURE 1. Position the paper template supplied on the wall and using a pencil mark the position of the opening to be made in the wall at a height of around 200 cm from the floor and 15 cm from the ceiling (see the recess outline on the reference template). Unusual installation positions must be worked out case by case. Whenever the paper template has not been provided, see the dimensions shown in the drawing on Page 11. 2 Make an opening of adequate depth in the wall bearing in mind that the unit'

  • Diva RDW 9RN, 28 7. condensate drain preparation Whenever the unit must be removed, make sure to first drain the condensate collection tray to avoid annoying water spills. During transport, always leave the air conditioner positioned upright on a flat surface and never rest it on its front plastic part or on its rear part. N.B.:Whenever it is impossible to send all the condensate created outside the room, see the paragraph "Auxiliary condensate drai- nage" on Page 18.. fig. 6 fig. 7 Assemble the condensate drainage pipe by firmly pushing and twisting it towards the air conditioner as shown in Figures 6 and 7, bea- ring in mind that inco

  • Diva RDW 9RN, 29 8. Installation of the unit IMPORTANT: Handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will remain in view. IMPORTANT: whenever the opening in the wall made for the unit is not equipped for the connection to the electrical power sup- ply, remember to make an adequate opening in the wall for the exit of the air conditioner's power supply cable. The creation of this space is essential because at the end of installation a plate in ABS will be inserted in front of the unit to mas

  • Diva RDW 9RN, 30 The pipe protection grills must be applied outside the wall where the unit is installed. Cut part of the right grill (looking at the unit from the rear) in order to permit the con- densate drainage pipe to exit correctly (see Figure). 10. Rear grills At the end of installation operations, the grills must be applied to the air circulation pipes. As above, this particular measure will ensure better unit operation because not only will the air be filtered and therefore the heat exchange system will remain cleaner (and maintain yield over a longer period of time), but will also prevent the deposit of leaves or other clogging material in the pipes and in

  • Diva RDW 9RN, INSTALLATION DIMENSIONS (SEEN FROM INSIDE) N.B.: DIMENSIONS FOR THE CONDENSATE DRAINAGE AND VENTILATION HOLES! THE OUTLINE REGARDS THE UNIT'S REAL PERIMETER AND NOT THE OPE- NING TO BE MADE IN THE WALL, WHICH MUST CONSEQUENTLY BE INCREASED BY 10 MM ON EACH SIDE AND 20 MM IN HEIGHT. IMPORTANT: THESE DIMENSIONS ARE IN MILLIMETERS 31

  • 32 CEILING INSTALLATION This type of installation is used when the unit cannot be adequately fastened or recessed into a wall or whenever the wall is made of glass (for example display windows, etc.). In this case, the unit is anchored to the ceiling by chain or threaded bars and the strength and construction of the ceiling must be carefully checked in order to employ e

  • Diva RDW 9RN, 33 fig. 3 fig. 4 Remove the eyelets and replace them with threaded bars whenever necessary. N.B. Correct installation requires that the unit must be fastened at all four anchor points provided. For threaded bar suspension, remove the eyelets and then lock the threaded bars adequately using washers and bolts. The unit must never be installed too far from the wall or pane of glass because the air expulsion pipes must reach the outdoors. Apply the two brackets (as described in Figures 3 and 4) with threaded holes for the application of the M8 eyelets for the fastening of the chains. Insert all the extra-long screws supplied with the cei

  • Diva RDW 9RN, 34 CEILING INSTALLATION ASSEMBLY PROCEDURE - WALL 1. Position the supplied paper template on the wall and using a pencil mark the position of the two holes to be drilled at a height of around 200 cm from the floor and 15 cm from the ceiling. Unusual installation positions must be worked out case by case. Whenever the paper template has not been provided, see the dimensions shown in the drawing on Page 11. 2. Drill adequate holes for the suction and expulsion of the air using drill bits. These holes must slope slightly downward by appro

  • Diva RDW 9RN, CEILING INSTALLATION ASSEMBLY PROCEDURE - GLASS 1. Position the paper template supplied on the glass and with a pencil mark the positions of the two holes at a height of approxima- tely 200 cm above the floor and 15 cm from the ceiling. N.B.:Avoid to make pipes’ holes too close to the edge of the glass because that could cause structural sigging of the pane. Particular situations must be worked out case by case. Whenever the paper template is not present, take the dimensions shown in the drawing on Page 11 as reference. 2. Have adequate air suction and expulsion holes

  • Diva RDW 9RN, 36 1a. Condensate drainage preparation Whenever the unit must be removed, make sure to first drain the condensate collection tray to avoid annoying water spills. During transport, always leave the air conditioner positioned upright on a flat surface and never rest it on its front plastic part or on its rear part. N.B.:Whenever it is impossible to send all the condensate created outside the room, see the paragraph "Auxiliary condensate drai- nage" on Page 18.. fig. 9 fig. 10 Assemble the condensate drainage pipe by firmly pushing and twisting it towards the air conditioner as shown in Figures 9 and 10, bea- ring in mind that

  • AIR SUCTION AIR EXPULSION CONDENSATE DRAINAGE 2a. Installation of the unit IMPORTANT: Handle the unit with care paying extra attention to avoid damaging or scratching the parts of the unit that will remain in view. Hang the air conditioner on the bracket provided on the ceiling by passing the condensate drainage pipe correctly along the air expulsion pipe and then checki

  • Diva RDW 9RN, 38 AUXILIARY CONDENSATE DRAINAGE Remove the plug from the condensate drainage nozzle positioned at the lower right as shown in Figure 1, making sure to avoid cutting your hands and damaging the heat exchanger. Whenever crushed or damaged wings are observed, straighten them before switching the unit on. Pull the electric heating element completely inside the unit. N.B. NEVER CUT THE ELECTRIC HEATING ELEMENT. Make the hole for the passage of the auxiliary condensate drainage pipe in the rear panel; it is masked by insulation material that covers the plate (Figure 2); cut away the covering w

  • Diva RDW 9RN, 6. POWER SUPPLY 9. OPTIONAL KITS CEILING INSTALLATION KIT (Code: 231065) Containing 2 brackets with eyelets and screws for the fastening of threaded bars or chains to the unit.. 8. STANDARD KITS Containing 2 air expulsion pipes (max. 40 cm length), flanges for the connection of the pipes to the machine, external closing grills, the ABS plate to slide the unit into the opening in the wall, the installation frame, a stiff standard condensate drainage pipe and a flexible rubber auxiliary condensate drainage pipe.. 7. LIMITS TO OPERATION the unit automatically evaporates the water that has condensed inside.At relative humidity values of more than 60%, the excess condensate is

Related Products and Documents (Air Conditioner):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Kenwood KR-V7070 Instruction manual kenwood/kr-v7070-X87.pdf 17 Aug 2022 28
2 Samsung SNP-5300 Specifications samsung/snp-5300-3K4.pdf 20 Apr 2023 2 1.36 Mb
3 ClearSounds PHONE A1600 Quick start manual clearsounds/phone-a1600-R66.pdf 17 Jul 2023 18 0.54 Mb
4 LG LFX31995ST Energy manual lg/lfx31995st-X91.pdf 07 Mar 2024 1
5 Yamaha YSP-3300 Owner's manual yamaha/ysp-3300-N9H.pdf 12 Jul 2023 80 4.02 Mb
6 Omega Altise APC12 Operation & user’s manual omega-altise/apc12-865.pdf 08 Oct 2022 14

Similar Resources:

  • LG

    MULTI V ARNU05GL4G4

    (11 pages)
    ARNU05GL4G4 ARNU07GL4G4 ARNU09GL4G4 ARNU12GL5G4ARNU15GL5G4 ARNU18GL5G4 ARNU24GL6G4P/NO.:MFL67088416REV.00_081820Copyright © 2020 LG Electronics Inc.All Rights Reserved. …
  • Julabo

    F12-MC

    (56 pages)
    Artisan Technology Group is your source for quality new and certied-used/pre-owned equipment• FAST SHIPPING AND DELIVERY• TENS OF THOUSANDS OF IN-STOCK ITEMS• EQUIPMENT DEMOS• HUNDREDS OF MANUFACTURERS SUPPORTED• LEASING/MONTHLY RENTALS• ITAR CERTIFIED SECURE ASSET SOLUTIONSSERVICE CENTER REPAIRSExperienced engineers and techni …
  • Johnson Controls

    (H,Y,C)IDM030B21E

    (40 pages)
    PMGB0400B-rev.2InstallationandMaintenanceManualINVERTER-DRIVENMULTI-SPLIT SYSTEMHEAT PUMPAIR CONDITIONERSIMPORTANT: READ AND UNDERSTAND THIS MANUAL BEFORE USING THIS HEAT PUMP AIR CONDITIONER. KEEP THIS MANUAL FOR FUTURE REFERENCE.Type ModelDucted(Medium Static)withEconoFresh Kit(H,Y,C)IDM030B21E(H,Y,C)IDM036B21E(H,Y,C)IDM048B21EwithEF-456NE …
  • Ferroli

    ASTER 9

    (32 pages)
    A++A+USE AND MAINTENANCE MANUALENASTER 3.2 eClimatizzatore per ambienti Indoor air conditionerMANUALE INSTALLAZIONE E MANUTENZIONEIO-FRIENREFRIGERANT GASR32DLYEC …
  • Mitsubishi Electric

    PKA-A12HA

    (36 pages)
    SERVICE MANUALSPLIT-TYPE, HEAT PUMP AIR CONDITIONERSSPLIT-TYPE, AIR CONDITIONERSNOTE:• This manual describes only service data of the indoor units.• RoHS compliant products have <G> mark on the spec name plate. CONTENTS 1. REFERENCE MANUAL................................... 2 2. SAFETY PRECAUTION................................... 3 3. PART NAM …
  • teca

    AHP-401

    (8 pages)
    ProductInformationPacketModelAHP-401120VACSolidStateAirConditionerWithoutTemperatureControlPart#0-F090-0-000Thankyouforyourpurchase.Informationhasbeenenclosedregardingtheinstallation,specifications,andwiringofyoursolid-stateassembly.Pleasereadandfollowallinstructionscarefullybeforeinstallation.Onlyqualifiedtechniciansshouldinstallthisequipment.Ifyouhaveanyqu …

Comments, Questions and Opinions: