  • Cleanburn Skagen , JINHCE08 revB 03/10/11 Installation & Operating Instructions  TechnicalSpecification Appliance Mass 125 kg Total Efficiency 79.0 % Nominal Heat Output 6.0 kW Mean CO Emission (@13% O 2 ) 0.16 % Mean Flue Gas Temperature 280 °C Flue Gas Mass Flow 5.0 g/s This appliance is not for use in shared flue This appliance is suitable for intermittent burning        

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 TableofContents General Guidance ............................................................................................................ 2 Competent Persons Scheme ........................................................................ 2 CO Alarms .................................................................................................. 2 Health & Safety Precautions ....................................................................... 2 Handling ..................................................................................

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 Lighting the Stove ..................................................................................... 13 Reduced Combustion ................................................................................ 13 Recommended Fuels ................................................................................. 14 General Maintenance..................................................................................................... 15 Baffle ......................................................................................................... 15 Stove Body ...................

  • JINHCE08 revB 03/10/11 2  GeneralGuidance It is important that your stove is correctly installed as Cleanburn cannot accept responsibility for any fault arising through incorrect use or installation. Theseinstructionscoverthebasicprinciplestoensuresatisfactoryinstallationofthestove,althoughdetail mayneedslightmodific

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 3 Asbestos This stove contains no asbestos. If there is a possibility of disturbing any asbestos in the course of installationthenpleaseseekspecialistguidanceanduseappropriateprotectiveequipment. MetalParts Wheninstallingorservicingthisstove,careshouldbetakentoavoidthepossibilityofpersonalinjury. Modification Nounauthorizedmodificationofthisapplianceshouldbecarriedout. Safety WARNING – This appliance will be hot when

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 4 Adverse weather – In a small number of installations, occasional local weather conditions (e.g. wind from a particular direction) may cause downdraught in the flue and cause the stove to emit fumes. In these circumstances, the stove should not be used. A professional flue installer will be able to advise on solutions to this problem (e.g. anti-downdraught cowl). COAlarm Your installer should have fitted a CO alarm in the same room as the appliance. If the alarm so

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 Assembly Instructions   RemovalofHeatShield Toremovetheheatshield,removethebutton flextheheatshieldbypullingtheheatshieldtowardsyouuntil right handedgeclearsthestovebody handedgeclearofthestovebody andremove.       FlueCollar WindtheeightM6studssuppliedintothefixingholesinthefluecollarand blankingplateuntilfingertight. Place the gasket�

  • Cleanburn Skagen , JINHCE08 revB 03/10/11    BlankingPlate FittheFlueGasketandBlankingPlateontheremainingfreeoutlet Secureit,usingtheM6nutsand studs. RearFluePipeInstallation Forrearflueinstallations, theknock removed. Removethe heatshieldasinstructed holdingtheknock outsectionintheheatshieldandremove. anysharpedgesontheheatshield leftbehindbythe FittingofHeatShield Tofittheheatshield,positiontheleft shield until the ri

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 RemovalofInternalComponents The Fire Bricks, in thisappliance, are factory fit sequencethatyouwillneedtoemploywhenservicingyour SideBricks   2. RemovealloftheGrateBars.Takecaretonoticewhichare theupperandwhicharethelowerbars.Thiswillallowcorrect replacement.      4. SlidethebottomedgeoftheSideBrickstowardsthecentreof t

  • JINHCE08 revB 03/10/11 RearBrick   Pullthetopedgeof Stove.     Baffle/ThroatPlateFitting 8 Pullthetopedgeof each RearBrickforwardandliftthebrickoutofthe Stove.  ToinstalltheBaffle,slidetheleft handendoftheBaffleup, and over�

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 9  InstallationInstructions Chimney ThechimneyheightandthepositionofthechimneyterminalshouldconformtoBuildingRegulations. Checkthatthechimneyisingoodcondition,dry,freefromcracksandobstructions. Thediameteroftheflueshouldnotbelessthan150mmandnotmorethan200mm. Ifanyoftheserequirementsarenotmet,thechimneyshouldbelinedbyasuitablemethod. Ifthereis no existing�

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 10 FlueDraught Ifthedraughtexceedstherecommendedmaximum,adraughtstabilisermustbefittedsothattherateof burning can be controlled and to prevent over firing.  If the reading is less than the recommended minimum then the performance of the appliance will be compromised.  The flue draught should be checkedunderfireathighoutput. MinimumDraug

  • JINHCE08 revB 03/10/11 RecessedAppliance Thestovecanberecessedintoasuitablysizedfireplace we recommendthatafreeairgap of150mm isleftaroundthesidesandtopofthe stoveand atleast 50mmatthebackofthestovetoobtainmaximumheat�

  • JINHCE08 revB 03/10/11 12  OperatingInstructions Thisapplianceisnotsuitableforuseinasharedflue Thisapplianceshouldnotbeoperatedwiththedoorsopen AerosolSprays Donotuseanaerosolsprayonornearthestovewhenitisalight. AirControls T

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 13 RiddlingGrate YourCleanburnstoveisfittedwithalocomotivetypegrate.Sothatdeashingcanbecarriedoutcleanly andeasily,itisriddledfromtheoutsideofthestovewiththedoorsclosed. Toburnwood,pushtheoperatingtoolupandawayfromyou. Whenleftinthisposition,airisrestrictedthroughthebedofthefire

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 14 RecommendedFuels Cleanburnrecommendthatwoodlogsareburntinthisappliance. Burnonlydry,wellseasonedwood,whichshouldhavebeencut,splitandstackedforatleast12months, withfreeairmovementaroundthesidesofthestacktoenableittodryout. Burningwetorunseasonedwoodwillcreatetardepositsinthestoveandchimneyandwillnotproducea satisfactoryheatoutput. Onlyauthorisedsmokelessfuelsmaybe�

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 15  GeneralMaintenance ThisAppliancerequiresregularmaintenancebyacompetentengineer. Baffle Thisshouldberemovedandcleanedatleastonceamonthtopreventanybuildupofsootorflyashthat couldleadtoblockedfluewaysanddangerousfumeemission. Ifthebaffleisremovedthechimney/fluewaycanbesweptthroughtheappliance. StoveBody Th

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 16  Rope Checktheropearoundthedoor.Ifropeisbecomingdetached,useCleanburnropegluetoreattachit.If theropeisinapoorcondition,areplacementropekitmaybeorderedfromtheCleanburnstovesspares range. ChimneyandFlueways Itisimportantthatthechimney,fluewaysandanyconnectingfluepipearesweptregularly.Thismeans a

  • Cleanburn Skagen , JINHCE08 revB 03/10/11 17  Fireblazingoutofcontrol Checkthat:  Thedoorsaretightlyclosed.  Theaircontrolsareallintheclosedposition.  Asuitablefuelisbeingused.  Theglassretainingclipsarenotloose.  Thedoorropesealsareingoodcondition  Fluedraughtisbelowmaximumlevel(seeinstallationinstructions).

Related Products and Documents (Cooktop):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 HP EliteBook 8530p Maintenance and service manual hp/elitebook-8530p-62M.pdf 11 Feb 2024 167 5.82 Mb
2 Extron electronics DP DA2 Operation & user’s manual extron-electronics/dp-da2-QVS.pdf 07 Jan 2023 31
3 Custom Audio Electronics Plus II Operation & user’s manual custom-audio-electronics/plus-ii-35H.pdf 02 Sep 2023 64
4 Nortel Call Pilot A0789401 Quick reference manual nortel/call-pilot-a0789401-15P.pdf 19 Oct 2022 36
5 Medion Smartphone Instruction manual medion/smartphone-SO3.pdf 27 Mar 2023 70
6 Avenview SW-HDSDI-8X1 Operation & user’s manual avenview/sw-hdsdi-8x1-ZS4.pdf 03 Jan 2023 9 1.95 Mb

Similar Resources:

  • Jenn-Air

    JGC7530B

    (16 pages)
    LP GAS AND HIGH ALTITUDE CONVERSION INSTRUCTIONS FOR JGC7530B, JGC7636B, JGC1530B, AND JGC1536B MODEL SERIESINSTRUCTIONS DE CONVERSION - GAZ PROPANE ET ALTITUDE ÉLEVÉEPOUR SÉRIES DE MODÈLES JGC7530B, JGC7636B, JGC1530B, ET JGC1536BCOOKTOP SAFETYTable of Contents/Table des matièresCOOKTOP SAFETY............................................................ …
  • Wolf

    CT30EU

    (5 pages)
    Planning InformationNew 30" (762) Unframed Electric Cooktop— Available November 2007MODEL CT30EU1Dimensions in parentheses are inmillimeters unless otherwise specified.8/08Model CT30EUThe Wolf Model CT30EU 30" (762)unframed electric cooktop with blackceramic glass surface, can be mountedflush with the top of the countertop or asa frameless instal …
  • Smeg

    APC61BVG

    (24 pages)
    Contents 3 1 INSTRUCTIONS FOR SAFE AND PROPER USE________________________________4 2 INSTALLATION OF THE APPLIANCE__________________________________________6 3 ADAPTATION TO DIFFERENT TYPES OF GAS _________________________________8 4 FINAL OPERATIONS______________________________________________________11 5 DESCRIPTION OF FRONT PANEL CONTROLS ______ …
  • Electrolux

    Libero Line 601595

    (2 pages)
    Approval: ____________________________________________601595 (EDILU) Infrared Cooktop - 208 V/1p/60HzItem No. ____________________________________Unit shall be Electrolux freestanding tabletop design Two-Zone Infrared Cooktop. One-piece, seamless 304 stainless steel con-struction and heavy duty, high impact Ceran® glass cooking surface. Unit shall have t …
  • Coleman

    5453A Series

    (24 pages)
    IMPORTANTRead this manual carefully before assembling, using or servicing these stoves. Keepthis manual for future reference. If you have questions about assembly, operation,servicing or repair of these stoves, please call Coleman at 1-800-835-3278 or TDD:316-832-8707. In Canada call 1-800-387-6161.Propane StovesRéchauds à propaneEstufas de gas PropanoInst …
  • Dacor

    Epicure ER30DSCH

    (36 pages)
    Use and Care ManualEpicure® RangePart No. 102188 Rev. DTa b l e o f C o n t e n t sImportant Safety Instructions ............................................. 1-4Getting To Know Your Range ............................................ 4-6Setting Up Your Range ..................................................... 7-9Operating the Cooktop ............ …

Comments, Questions and Opinions: