Text of eta PE-K User Guide:

  • 61 User Manual PE-K 35-90 kW 2012-03 Store with switch unit Overview, buttons, functions Ready The switching unit has reached the position for conveying from a suction head. Filling up will now begin. Drive The switching unit is switching between suction heads. Fill up Filling up has started and pellets are being conveyed. Rinse The switching unit has switched to rinse mode. The conveying

  • eta PE-K, 64 www.eta.co.at Subject to change due to technical improvements Requirements Remote operation Using remote control With remote control, you can control your ETA boiler over long distances via the Internet with a PC, smartphone or tablet (pad), just as if your were standing in front of the boiler's touch screen. For example, if you are away from home for a long time, you can verify that the heating is switched off. You can also switch it back on before you return. The ETA boiler's touch screen is connected to the Internet. Once you have registered your touch screen, you can log in t

  • eta PE-K, 75 User Manual PE-K 35-90 kW 2012-03 Efficient and low-emission operation Dear customer, Your new boiler is labelled with the "Blue Angel" to indicate its environmental friendliness. With this in mind, please note the following for effi cient and low-emission operation of your heating system: 1. The installation and adjustment of the heating system must be performed only by qualifi ed and trained personnel. 2. Use only the fuels specifi ed by us in the user manual (in the warranty conditions). Only in this way can low-emission, economical and fault-free operation of your heating system be ensured. 3. Perform the maintenance and cleaning procedures recommended

  • eta PE-K, 76 www.eta.co.at Subject to change due to technical improvements Safety instructions PE-K_Bedienung_2012-03_EN, subject to technical alterations Prevent moisture from damaging pellets! Danger! Moving parts may cause injuries! Open door to pellet store, filling and venting nozzles for minimum 60 minutes ventilation prior to entering storeage area! Ensure that the ETA pellet boiler is in automatic mode while store is being filled! Switch main power supply to OFF before entering the pellet storage area! Smoking, naked flame or any other ignition sources are prohibited! No entry for un

  • eta PE-K, 16 www.eta.co.at Subject to change due to technical improvements Adjusting ash removal idletime When fuel causes slag formation Adjusting the ash removal idletime The "Start idletime" parameter is used to select the time from which the boiler ceases to de-ash. The time for which ash removal is locked can be altered using the "Duration idletime" parameter. The "Start idletime" time applies for every day of the week. The factory setting for this is 21:00. Press the buttons

  • 38 www.eta.co.at Subject to change due to technical improvements Changing names of function blocks User interface Changing the name using the keyboard cancel save Use the keyboard to enter the new name for heating circuit 1, in this example: FLOOR. Then press the button to save the new name. The button cancels the renaming process and changes back to the

  • eta PE-K, 48 www.eta.co.at Subject to change due to technical improvements Operating modes Heating circuit On Night The heating circuit is outside of the timer's time slots and in "Night" mode. The fl ow temperature of the heating circuit is regulated using the "Heating curve night". If the unit has a built-in room sensor, the temperature is regulated to the stored "set-back temperature". The switch can be in either the "Auto" or the "Night" po

  • eta PE-K, 63 User Manual PE-K 35-90 kW 2012-03 Store with switch unit Entering stock Entering new stock quantity after a delivery of pellets After the store has been fi lled with pellets, the new stock quantity should be entered. This way, the control system is always able to calculate the approximate pellet stock level. In the overview screen, tap the button. A screen opens: Enter the new stock quantity and press to save. The display returns to the overview. The "Switching at" parameter This parameter is used

  • eta PE-K, 22 www.eta.co.at Subject to change due to technical improvements Every 2,500 h or yearly Maintenance Maintenance every 2,500 hours or yearly, for miscanthus after 1,250 h When this maintenance is due, a message appears on the screen. Boiler TUE 4/4/2011 11:25:45 Cleaning after 2500 hours Reminder for periodic cleaning of the heating system as per user manual Check grate if ash has slag If there are large and very hard, glassy pieces of slag in the ash, the combustion chamber and grate must be inspected. Individual small

  • 3 User Manual PE-K 35-90 kW 2012-03 Preface Dear customer, We are delighted to count you among our customers. To ensure satisfactory operation of your new boiler, you need to know how to operate, clean and maintain it. This manual contains information and advice on much more than just the boiler itself. Warranty and guarantee You should also read the "Conditions for warra

  • 20 www.eta.co.at Subject to change due to technical improvements "Empty ash box" reminder Maintenance "Empty ash box" reminder The ash box should be emptied regularly. As such, the factory settings contain a pellet consumption level of 2000 kg, at which a reminder to empty the ash box appears. If the ash box is only part full after this

  • eta PE-K, 30 www.eta.co.at Subject to change due to technical improvements Approval, antifreeze, pressure equalisation, venting Approval Every heating system must be approved. Inquire at you building authority and ask your chimney sweep. Operation only by trained personnel The system may be operated only by trained personnel. Instruction can be given by the heating installer or our customer service. Please read this user manual to be assured of avoiding errors in operation and maintenance of the boiler. Fire extinguisher In Austria at least a powder extinguisher

  • 52 www.eta.co.at Subject to change due to technical improvements The heating curve Heating circuit The heating curve The heating curve controls the fl ow temperature for the "Day" and "Night" modes of the heating circuit in question. During a set time slot, the heating circuit is in "Day" mode. Outside the time slots, the heatin

  • eta PE-K, 4 www.eta.co.at Subject to change due to technical improvements Conditions for warranty, guarantee, liability We can only guarantee and accept liability for the function of our boiler if it is properly installed and operated. Requirement for warranty, guarantee and liability is that this boiler be used in accordance with its intended purpose, only for heating and hot water supply with no more than 2,000 full- load hours annually, and, in particular, that the following general conditions be observed during install

  • eta PE-K, 9 User Manual PE-K 35-90 kW 2012-03 Before starting Everything closed and airtight? Before starting the system Before starting the system, check the following to ensure smooth and problem-free operation. No leak air Verify that all doors and maintenance covers are tightly closed, especially before initial start-up and after any maintenance. Leak air can reduce boiler output, but above all it shifts the lambda measurement to lower air supply, which makes the combustion chamber become hotter. Th

  • eta PE-K, 36 www.eta.co.at Subject to change due to technical improvements Adjusting date and time User interface Overview of the selected function block. Text menu for adjusting the parameters of the selected function block I/O list allowing experts to assign inputs and outputs Toolbox for experts INFO Help Error messages for the selected function block Use the horizontal buttons to select the individual function blocks (FUBs) of the heating system. The vertical buttons are used to open the different views for the selected function block (F

  • eta PE-K, 68 www.eta.co.at Subject to change due to technical improvements Logging out Remote operation Logging out of remote control Once you have fi nished using remote control, press the [Logout] button on the homepage. The display returns to the start page. Logging out minimises the data fl ow from the touch screen to the homepage, thus signifi cantly reducing the download volume. This is especially important for reducing the download volume for Internet connections without a fl atrate tariff. The touch screen remains connected to the meinETA server via the Internet. Automatic logout after 10 minutes of inactivity If the remote control remains unused for longer than 10 minute

  • eta PE-K, 50 www.eta.co.at Subject to change due to technical improvements Setting heating time slots Heating circuit Setting the heating time slots The heating circuit timer can be used to set 3 different time slots for the heating for each day of the week. If the unit has a room sensor, a target room temperature can also be set for each time slot. Likewise, the reduced room temperature (set-back temperature) between the heating time slots can also be adjusted for each day of the week. "Day"

  • eta PE-K, 60 www.eta.co.at Subject to change due to technical improvements Overview, buttons, functions Store with switch unit "Pellet store" overview Press and to open the "Store with switching unit" overview screen. In this function block, a pellet conveying system is controlled using a switching unit and 2 or 3 suction heads. The individual suction heads can be manually selected, locked and enabled. The conveying and rinse modes are indicated by a green line between the suction head and the switch

  • eta PE-K, 62 www.eta.co.at Subject to change due to technical improvements Locking and changing heads Store with switch unit Locking/enabling a suction head If the store above a suction head is empty or if a suction head is damaged, it can be locked. The switching unit will then no longer select this suction head. Tap the corresponding suction head to enable or lock it. Manually switching between suction heads Pressing manually switches between the enabled suction heads. Depending on the position of the switching unit, the following icons are displayed in the overview: Switching unit switching suction

  • eta PE-K, 12 www.eta.co.at Subject to change due to technical improvements Overtemperature protection Protection against boiler overheating The boiler is factory-equipped with safety features to prevent it from overheating. During installation, additional equipment such as thermal emergency cooling valve and safety valve must be installed. Safety valve Thermally actuated drain valve The following safety chain takes effect if the boiler exceeds the operating temperature for any reason: t over 90 °C -> pump safety run t over 95 °C -> thermal emergency cooling valve t over 105 °C -> safety temperature limiter t over

  • eta PE-K, 44 www.eta.co.at Subject to change due to technical improvements Adjusting ash removal idletime Boiler Adjusting the ash removal idletime The "Start idletime" parameter is used to select the time from which the boiler ceases to de-ash. The time for which ash removal is locked can be altered using the "Duration idletime" parameter. The "Start idletime" time applies for every day of the week. The factory setting for this is 21:00. Press the buttons and to go to the text menu. Tap the [Boiler] line and, in the submenu, tap the [Ash removal] line. Double-tap the [Start

  • eta PE-K, 49 User Manual PE-K 35-90 kW 2012-03 Heating circuit Operating modes On Screed The heating circuit is in operation; the screed drying program is being run. Off Enable temp. The heating circuit is still switched off because the boiler is not yet able to supply suffi cient heat. The enable temperature for the heating circuit has not yet been exceeded. Off Target day The heating circuit is switched off. The target fl ow temperature calculated from the heating curve "Day" is below the room temperature as measured by the room sensor. If the unit does not have a room sensor, the calculated target fl ow temperature is below 18°C. Off Target night The heating circuit is

  • eta PE-K, 42 www.eta.co.at Subject to change due to technical improvements Overview, buttons, functions Boiler Heating Current operating mode This line shows the current operating mode of the boiler. Below is a list of the possible modes: Switched off The boiler is switched off. The on/off button is lit up red. Standby fi ll up Pellets are sucked into the storage tank so that the boiler can attempt to ignite. It is not possible for the unit to heat whilst in this mode. Stop fi ll-up The suction process used to fi ll the boiler storage tank is interrupted in order to ignite pellets and start up the boiler.

  • eta PE-K, 69 User Manual PE-K 35-90 kW 2012-03 Remote operation Changing personal details You can now change your password and core details. Press the [Change password] or [Change data] button to save your changes. If a touch screen is added at a later date, the current login data (username and current password) are always required. Personal login data Once you have registered, you will be sent your personal login data (username and password). For the login at <www.meinETA.at>, it is only possible to change the password. Your username will always stay the same, even if you change the e-mail address in your personal details. I

More Instructions:

DOWNLOAD
DOWNLOAD

Related Products and Documents (Boiler):

Comparable Devices:

# Manufacturer Model Document Type File Updated Pages Size
1 Electro-Voice TL 15-1XSX Service data electro-voice/tl-15-1xsx-CNV.pdf 23 Aug 2022 2 0.26 Mb
2 Rosen AV7500 Quick reference card rosen/av7500-718.pdf 30 Jan 2024 2 2.83 Mb
3 THOMSON DTH600 Operation & user’s manual thomson/dth600-F2T.pdf 23 May 2023 27 2.27 Mb
4 FUTABA FP-3FN Instruction manual futaba/fp-3fn-8TI.pdf 09 Aug 2022 20 1.25 Mb
5 Swann DIY Security Cams SW216-2DS Specification swann/diy-security-cams-sw216-2ds-764.pdf 15 Mar 2024 2
6 Samsung CT-1488BL Owner's instructions manual samsung/ct-1488bl-477.pdf 22 Dec 2022 38 1.83 Mb

Similar Resources:

  • Beretta

    12 R.S.I.

    (29 pages)
    MYNUTEGREENC.S.I.-R.S.I.EN INSTALLER AND USER MANUALES MANUAL DE INSTALACIÓN Y USOPT MANUAL PARA INSTALAÇÃO E USOHUTELEPÍTŐI ÉS FELHASZNÁLÓI KÉZIKÖNYVROMANUAL DE INSTALARE SI UTILIZAREDE HANDBUCH FÜR DIE MONTAGE UND BENUTZUNGDK INSTALLATIONS- OG BRUGERVEJLEDNINGSINAVODILA ZA VGRADITEV, PRIKLJUČITEV IN UPORABOHRPRIRUČNIK ZA MONTAŽU I KORIŠTEN …
  • IDEAL

    Vogue System Gen 2 S15

    (80 pages)
    When replacing any part on this appliance, use only spare parts that you can beassured conform to the safety and performance specification that we require. Do not use reconditioned or copy parts that have not been clearly authorised by Ideal.For the very latest copy of literature for specification and maintenance practices visit our website www.idealboile …
  • Worcester

    Highflow 3.5 OF

    (28 pages)
    ......-~..; ~ORCESTER___.. Bighflow 3.5 OF OPEN FLUED MODEL FLOOR STANDING COMBINATION BOILER FOR CENTRAL HEATING AND MAINS FED DOMESTIC HOT WATER INSTALLATION AND SERVICING INSTRUCTIONS GC NUMBER 41 311 38 BOILER OUTPUT To Hot Water Maximum 22.9 kW (78,000 Btu/h) To Central Heating Minimum 8.8 kW (30,000 Btu/h) Maximum 22.9 kW (78,000 Btu/h) IMPORTANT: THIS …
  • Raypak

    503A

    (60 pages)
    INSTALLATION & OPERATING INSTRUCTIONSCATALOG NO. 3400.531A Effective: 10-03-13 Replaces: 04-09-13 P/N 241511 Rev. 2WARNING: Improper installation, adjustment, alteration, service or maintenance cancause property damage, personal injury, exposure to hazardous materials* or loss oflife. Review the information in this manual carefully. *This u …
  • Froling

    FHG

    (54 pages)
    Froling GmbH, Industriestraße 12, 4710 Grieskirchen, AUSTRIA www.froling.com A French language manual may be obtained from Tarm Biomass by calling 800-782-9927 or by email request to: [email protected]. Operation and Service Manual Wood-Fired Central Heating Boiler FHG Read and follow the operating instructions and safety information! Subject t …
  • Bosch

    BENCHMARK 14/19

    (4 pages)
    9/14, 14/19 & 19/24CBiUSER INSTRUCTIONS & CUSTOMER CARE GUIDE134Central Heating When a demand is made for heating by the system controls(i.e. a programmer or room thermostat). A pump will energisecirculating primary water around the heating system and the burner,after a few seconds, will light. The heat output from the appliance inthis mode has been …

Comments, Questions and Opinions: